Loading...
HomeMy WebLinkAboutA001 Site PlanReflective aluminum sign Van accessible reflective aluminum sign where occurs 2" Dia. galvanized steel pipe Sloped for drainage 1/2" premolded expansion joint filler w/ bulking top Concrete slab orasphalt paving as occurs Concrete Footing Note: Verify location of underground utilities before drilling for concrete foundation. n Detail - Accessible Parking 112 = 1'-0" ® e a n Detail - Bollard 1/2" = 1'i Rounded concrete cap Standard 6" D steel pipe filled w/ concrete. Paint 2 coats '7raRic yellow" Sloped for drainage 1/2" premoltletl expansion joint filler w/sealant top Concrete slab or asphalt Paving as occurs Concrete Footing Note: Verify location of underground utilities before drilling for concrete foundation. /T Detail - To -Go Sign 1/2" = 1'-0" Chuys To -Go parking signage by owner 2" Dia. galvanized steel pipe Sloped for drainage 1/2" premoltletl expansion joint filler w/ cu lking top Concrete slab or asphalt Paving as occurs Concrete Footing more: Verify location of underground utilities before drilling for concrete foundation. General Notes = Site Plan 1 Protect area is limited to scope of work boundary line. All other site items shown are NIC and shown for reference only unless noted otherwise. 2 For utility tie-in information, reference MEP and civil drawings. 3 Lantlscepe shown for reference only. Refer to the landscape plan. LOI Uitility Requirements 1 Landlord re provide ELECTRICAL SERVICE 2 Landlord to provide WATER SERVICE 3 Landlord to provide GAS SERVICE 4 Landlord to provide SANITARY SERVICE 5 Landlord to provide STORM SERVICE AND RETENTION 6 Landlord to provide FIRE SUPRESSION WATER MAIN 7 Landlord to provide TELEPHONE SERVICE 8 Landlord to provide GREASE WASTE 9 Landlord to provide FIRE HYDRANTS Legend - Site Plan Property Line Integral Colored Concrete •- - (Solomon - CLAY 413) Property Setback Line — - - Landscape Easement ------. Scope of Work III--------------- Accessible Path of Travel ® Accessible Parking(NIC) Landscape Area - Reference landscape drawings Plan note W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W J W W J W W W W W W W W W W W W W W W W W W W W W W W W W J W W W W W W W W W W W W W W W W W W US 421 (Michigan RD) m r- �E7 rNh vN U H �.7 � m m y oN U N c pcb L C -- o a�°E U V U 3 UCU 0 3 o C 5 U Carmel (Zionsville), IN 10325 N. Michigan RD. Carmel, IN 46032 Owner: Chuys OPCO 1623 Tommy Road Austin, TX. 78704 Ph: (512) 473-2783 Contact: Michael Hatcher Architect: Parkway CBA, LP 1000 Civic Circle Lewisville, TX. 75067 Ph: (469) 322-3714 Project Contact: Bill Pounds, AIA MEP Engineer: Diaelectic Engineering 310 W. 20th Street Suite 200 Kansas City, MO 64108 Ph: (816) 997-9627 Contact: Joe Hillebrenner, P.E. Structural Engineer: Armstrong -Douglas 6060 N. Central Expressway Suite 800 Dallas, TX 76206 Ph- (214) 237-7022 Contact: Scott Armstrong, P.E. Landscape Architect: Belle Firma, Inc. 4245 North Central Expy. Suite 501 Dallas, Texas 75205 Ph: (214) 865-7192 Contact: Kon Haug, ASLA, CLARB Architect Greg Klini Date Author Checker 04-97221 t C4'. - "1-..1- B Site Plan RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel '�"lgi DATE: V,5/LD/-1U A001