HomeMy WebLinkAboutA005 Accessibility Standard03.4 Floor and Ground Surfaces. Vehicle pull-up spaces and access aisles
5 00 o p p p
sewingthem shall Com with 302. Access aisles shall be at the same level as
comply
with
vehicle pull-up space the serve. Changes in level are not rtnitted.
P P P Y 9
EXCEPTION: Slopes not steeper than 1:48 shall be permitted..
5035 Vertical Clearance. Vehicle pull-up spaces, access aisles serving them,
and a vehicular route from an entrance to the passenger loading zone, and from
the passenger loading zone to a vehicular exit shall provide a vertical clearance
of 114 inches (2895 mm) minimum.
504 Stairways
504.1 General. Stairs shall comply with 504.
5042 Treads and Risers. All steps on a flight of stairs shall have uniform riser
heights and uniform tread depths. Risers shall be 4 inches (100 mm) high
minimum and 7 inches (180 mm) high maximum. Treads shall be 11 inches (280
mm) deep minimum.
504.3 Open Risers. Open risers are not permitted.
504.4 Tread Surface. Stair treads shall comply with 302. Changes in level are
not permitted.
EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48.
504S Nosings. The radius of curvature at the leading edge of the tread shall be
1/2 inch (13 mm)maximum. Itosings that project beyond risers shall have the
underside of the leading edge curved or beveled. Risers shall be permitted to
sloe under the tread al an angle of 30 degrees maximum from
P 9 9
vertical. The ermined projection of the nosing shall extend 1 1/2 inches 38
P P 1 9
mm) maximum oWi)jye tread below.
1/2
max 30° max
(a) (b)
radius of tread edge angled riser
(typical for all profiles)
1'/2 max 1'/2 Max
(c) (d)
curved nosing
beveled nosing
Figure s 504.5 Stair Nosin
9 9
504.6 Handrails. Stairs shall have handrails complying with 505.
504.7 Wet Conditions. Stair treads and landings subject to wet condifions shall
be designed to prevent the accumulation of water.
505 Handrails
505.1 General. Handrails provided along walking surfaces complying with 403,
required at ramps Complying with 405, and required at stairs Complying with 504
shall comply with 505.
5052 Where Required. Handrails shall be provided on both sides of stairs and
q
ramps.
EXCEPTION: In assembly areas, handrails shall not be required on both sides
of aisle ramps where a handrail is provided at either side or within the aisle width.
P
505.3 Continuity. Handrails shall be Continuous within the full length of each
stair flight or ramp run. Inside handrails on switchback or dogleg stairs and
ramps shall be Continuous between flights or runs.
EXCEPTION: In assembly areas, handrails on ramps shall not be required to be
Continuous in aisles serving seating.
505A Height. Top of gripping surfaces of handrails shall be 34 inches (865 mm)
minimum and 38 inches (965 mm) maximum vertically above walking surfaces,
stair nosings, and ramp surfaces. Handrails shall be at a consistent height above
walking surfaces, stair nosings, and ramp surfaces.
M8
4177
a) (b) (c)
stairs ramps walking
Figure 505.4 Handrail Height surfaces
505.5 Clearance. Clearance between handrail gripping surfaces and adjacent
surfaces shall be 1 1/2 inches (38 mm) minimum.
1'/a min
38
Figure 505.5 Handrail Clearance
505.E Gripping Surface. Handrail gripping surfaces shall beconfin o s
505.6 Gripping Surface. Handrail gripping surfaces shall be Continuous along
their length and shall not be obstructed along their tops or sides. The bottoms of
handrail gripping surfaces shall not be obstructed for more than 20 percent of
their length. Where provided, horizontal projections shall occur 1 1/2 inches (38
mm) minimum below the bottom of the handrail gripping surface.
EXCEPTIONS:
1. Where handrails are provided along walking surfaces with slopes not steeper
than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be
obstructed along their enfire length where they are integral to crash rails or
bumper guards.
2. The distance between horizontal projections and the bottom of the gripping
surface shall be permitted to be reduced by 1/8 inch (3.2 mm) for each 1/2 inch
(13 mm) of additional handrail
perimeter dimension that exceeds 4 inches (100 mm).
�m
Figure 505.6 Horizontal Projections Below Gripping Surface
505.7 Cross Section. Handrail gripping surfaces shall have a cross section
complying with 505.7. 1 or 505.7.2.
505.7.1 Circular Cross Section. Handrail gripping surfaces with a circular
cross section shall have an outside diameter of 1 1/4 inches (32 mm) minimum
and 2 inches (51 mm) maximum.
505.7.2 Non -Circular Cross Sections. Handrail gripping surfaces with a
non -circular cross section shall have a perimeter dimension of 4 inches (100
mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section
dimension of 2 1/4 inches (57 mm) maximum.
(a) (b)
Figure 505.72 Handrail Non -Circular Cross Section
5059 Surfaces. Handrail gripping surfaces and any surfaces adjacent to them
shall be free of sharp or abrasive elements and shall have rounded edges.
505.9 Fittings. Handrails shall not rotate within their fittings.
505.10 Handrail Extensions. Handrail gripping surfaces shall extend beyond
and in the same direction of stair flights and ramp runs in accordance with
505.10.
EXCEPTIONS:
1. Extensions shall not be required for confinuous handrails at the inside turn of
switchback or dogleg stairs and ramps.
2. In assembly areas, extensions shall not be required for ramp handrails in
aisles serving seating where the handrails are discontinuous to provide access
to seating and to permit crossovers within aisles.
3. In alterations, full extensions of handrails shall not be required where such
extensions would be hazardous due to plan configuration.
505.10.1 Top and Bottom Extension at Ramps. Ramp handrails shall extend
horizontally above thelanding for 12 inches (305 mm) minimum beyond the top
and bottom of ramp runs. Extensions shall return to a wall, guard, or the landing
surface or shall be continuous to the handrail of an adjacent ram run.
• 1 P
12 min
12 min
Figure 505.10.1 Top and Bottom Handrail Extension at Ramps
.102 T Extension a S irs. At the to of a stair flight, handrails shall
505 ot Stairs. P
extend horizontallyabove the landing for 12 inches 305 ram minimum
9
beginning direct) above the first riser nosin .Extensions shall return to a wall
9 9 Y nosing
.Extensions
or the landing surface, or shall be continuous to the handrail of an
adjacent stain n9ghh
305
Figure 505.10.2 Top Handrail Extension at Stairs
505.10.3 Bottom Extension at Stairs. At the bottom of a stair flight, handrails
shall extend at the slope of the stair flight for a horizontal distance at least equal
P 9 q
to one tread depth beyond the last user nosing.Extension Shall return to a wall
P Y
guard, or the landing surface, or shall be Continuous to the handrail of an
adjacent stair flight.
F4
Note: x=tread neigh
q
Figure 505.10.3 Bottom Handrail Extension at Stairs
601 General
601.1 Scope. The provisions of Chapter 6 shall applywhere required by
Chapter 2 or where referenced lo a requirement in this document.
P Y q
602 DrinkingFountains
602.1 Generl. Drinking fountains shall complywith 307 and 602.
602.2 Clear Floor Space. Units shall have a clearfloor or ground space
complying with 305 positioned for a forward approach and centered on the unit.
Knee and toe clearance complying with 306 shall be provided.
EXCEPTION: A parallel approach complying with 305 shall be permitted at units
for children's use where the spout is 30 inches (760 mm) maximum above the
finish floor or ground and is 3 1/2 inches (90 mm) maximum from the front edge
of the unit, including bumpers.
602.3 Operable Parts. Operable parts shall comply with 309.
602.4 Spout Height Spout outlets shall be 36 inches (915 mm) maximum
above the finish floor or ground.
shall be located 15 inches (380 mm)
and 5 inches (125 mm) maximum from the
15 min
Sag
5m
X„v$
125
mro�
sd ➢$
Figure 602.5 Drinking Fountain Spout Location �8
602.6 Water Flow. The
spout shall provide a flow of water 4 inches 100 mm
P
high minimum and shall be located 5 inches (125 ram) maximum from the front
of the unit. The angle of the water stream shall be measured horizontally relative
to the front face of the unit. Where spouts are located less than 3 inches (75
mm) of the front of the unit, the angle of the water stream shall be 30 degrees
maximum. Where spouts are located between 3 inches (75 mm) and 5 inches
(125 mm) maximum from the front of the unit the angle of the water stream shall
be 15 degrees maximum.
602.7 Drinking Fountains for Standing Persons. Spout outlets of drinking
fountains for standing persons shall be 38 inches (965 mm) minimum and 43
inches (1090 mm) max. above the finish floor or ground.
603 Toilet and Bathing Rooms
603.1 General. Toilet and bathing rooms shall comply with 603.
603.2 Clearances. Clearances shall comply with 603.2.
603.2.1 Turning Space. Turning space complying with 304 shall be provided
within the room.
6032.2 Overlap. Required dear floor spaces, clearance at fixtures, and fuming
space shall be permitted to overlap.
6032.3 Door Swing. Doors shall not swing into the dear floor space or
clearance required for any fixture. Doors shall be permitted to swing into the
required turning space.
EXCEPTIONS:
1. Doors to a toilet room or bathing room for a single occupant accessed only
through a private office and not for common use or public use shall be permitted
to swing into the clear floor space or clearance provided the swing of the door
can be reversed to comply with 603.2.3.
2. Where the toilet room or bathing room is for individual use and a clear floor
space complying with 305.3 is provided within the room beyond the are of the
door swing, doors shall be permitted to swing into the clear floor space or
clearance required for anyfxlure.
603.3 Mirrors. Mirrors located above lavatories or countertops shall be installed
With the bottom edge of the reflecting surface 40 inches (1015 mm) maximum
above the finish floor or ground. Mirrors not located above lavatories or
Countertops shall be installed with the bottom edge of the reflecting
surface 35 inches (890 mm) maximum above the finish floor or ground.
603.4 Coat Hooks and Shelves. Coat hooks shall be located within one of the
reach ranges specified in 308. Shelves shall be located 40 inches (1015 mm)
minimum and 48 inches (1220 mm) maximum above the finish floor.
603.5 Diaper Changing Tables. Diaper changing tables shall comply with
Sections 309 and 902.
603.6 Operable Parts. Operable parts on towel dispensers and hand dryers
serving accessible lavatories shall comply with Table 603.6.
Table 603.6
Maximum Reach Depth and Height
aximum
.5 inch
inches
inches
inches
inches
11 inches
Reach Depth
13 ram)
51 mm)
125 ram)
150 ram)
30 ram)
280 mm)
aximum
Bunches
6 inches
2 inches
0 inches
6 inches
inches
Reach Heigh
1220 ram)
1170 mm)
1065 mm)
10 15mm)
915 mm)
865 mm)
604 Water Closets and Toilet Compartments
604.1 General. Water closets and toilet compartments shall comply with 604.2
through 604.8.
EXCEPTION: Water closets and toilet compartments for children's use shall be
permitted to comply with 604.9.
6042 Location. The water closet shall be positioned with a wall or partition to
the rear and to one side. The centerline of the water closet shall be 16 inches
405 mm minimum to 18 inches
(455 ram) maximum from the side wall or partition, except that the water closet
shall be 17 inches (430 ram) minimum and 19 inches (485 ram) maximum from
the side wall or partition in the ambulatory accessible toilet compartment
specified in 604.8.2. Water closets shall be arranged for a left-hand or right-hand
approach.
t
16-18 17-19
4
05
4
55 (a) , (b)
wheelchair ambulatory
accessible accessible water
water closets closets
Figure 6042 Water Closet Location
604.3 Clearance. Clearances around water closets and in toilet compartments
shall comply with604.3.
604.3.1 Clearance width. Clearance around a water closet shall be 60 inches
(1525 mm) minimum measured perpendicular from the side wall
604.3.2 Clearance Depth. Cl earance around the water closet shall be 56
inches (1420 mm) minimum measured perpendicular from the rear wall.
Other fixtures
not allowed
within this area
O
�g
60 min
Figure 604.3.1 Size of Clearance for Water Closets
604.3.3 Clearance Overlap. The required clearance around the water closet
shall be ermined to overlap the water closed, associated grab bars dispensers,
P P 9 Pe
sanitary napkin disposal units, coat hooks, shelves, accessible routes, Gear floor
space and clearances required at other fixtures, and the turning space. No other
fixtures or obstructions shall be located within the required water closet
clearance.
604.4 Height. The height of a water closet seat shall be 17 inches (430 mm)
minimum and 19 inches (485 mm) maximum above the floor, measured to the
top of the seat. Seats shall not be spmng to return to a lifted position.
EXCEPTIONS: A water closet in a toilet room for a occu single ant accessed
9 P
onlythrough a private office and not for common use or public use shall not be
9 P
required to comply with 604.4.
II
17-19
3aas5
t �
a
Note: For Mildraisdimensuns sas Fig. 604.11.4
Figure 604.4 Water Closet Seat Height
604.5 Grab Bars. Grab bars for water closets shall Comply with 609 and shall
be provided in accordance with Sections 604.5.1 and 604.5.2. Grab bars shall
be provided on the rear wall and on the side wall closest to the water closet..
EXCEPTIONS:
1. Grab bars shall not be required to be installed in a toilet room for a single
occupant accessed only through a private office and not for common use or
public use provided that reinforcement has been installed in walls and located
so as to permit the installation of grab bars complying with 604.5.
2. In detention or Correction facilities, grab bars shall not be required to be
installed in housing or holding cells that are specially designed without
protrusions for purposes of suicide prevention.
604.5.1 Fixed Side Wall Grab Bars. Fixed side -wall grab bars shall be 42
inches (1065 mm) minimum in length, located 12 inches (305mm) maximum
from the rear wall and extending 54 inches (1370 mm) minimum from the rear
wall. In addition, a vertical grab bar 18 inches (455 mm) minimum in length shall
be mounted with the bottom of the bar located 39 inches (990mm) minimum and
41 inches (1040 mm) maximum above the floor, and with the center line of the
bar located 39 inches (990mm) minimum and 41 inches (1040 mm) maximum
from the rear wall.
EXCEPTION: The vertical grab bar at water closets primarily for children's use
shall cornPY with Section 609.4.2.
Figure 604.5.1 Side Wall Grab Bar for Water Closets
604.5.2 Rear Wall. The rear wall grab bar shall be 36 inches (915 mm) long
minimum and extend from the centerline of the water closet 12 inches (305 mm)
minimum on one side and 24 inches (610mm) minimum on the other side.
EXCEPTIONS:
1. The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum,
centered on the water closet, where wall space does not permit a length of 36
inches (915 mm) minimum due to the location of a recessed fixture adjacent to
the water closet.
2. Where an administrative authority requires flush controls for flush valves to be
located in a position that Conflicts with the location of the rear grab bar, then the
rear grab bar shall be permitted to be split or shifted to the open side of the toilet
area.
Figure 604.5.2 Rear Wall Grab Bar at Water Closets
604.6 Flush Controls. Flush controls shall be hand operated or automatic.
Hand operated flush Controls shall comply with Section 309. Flush controls shall
be located on the open side of the water closet.
EXCEPTION: In ambulatory accessible compartments complying with Section
604.10, flush Controls shall be permitted to be located on either side of the water
closet.
604.7 Dispensers. Toilet paper dispensers shall comply with 309.4 and shall be
7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the
water closet measured to the centedine of the dispenser. The ouflet of the
dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm)
maximum above the finish floor and shall not be located behind grab bars.
Dispensers shall not be of a type that controls delivery or that does not allow
Continuous paper flow.
Figure 604.7 Dispenser Outlet Location
604.8 Coat Hooks and Shelves. Coat hooks provided within toilet
compartments shall be 48 inches (1220 mm) maximum above the floor. shelves
shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum
above the floor.
604.9 Wheelchair Accessible Compartments. Wheelchair accessible
compartments shall comply with 604.9.
604.9.2 Size. Toilet compartments shall comply with Section 604.9.2.1 or
604.9.2.2 as applicable.
604.9.2.1 Minimum area. The minimum area of a wheelchair accessible
compartments shall be 60 inches (1525 mm) wide minimum measured
to the side wall and 6 inches 1420 mm deep minimum for wall
perpendicular 5 ( )d p u
hung water closets and 59 inches (1500 mm) deep minimum for floor mounted
water closets measured perpendicular to the rear wall.
604.92.2 Compartment for children's use. The minimum area of a wheelchair
accessible compartment primarily for children's use shall be 60 inches (1525
mm) minimum in width measured perpendicular to the side well, and 59 inches
(1500 mm) deep minimum for wall hung and floor mounted Water closets
measured pi ll.
E O E� O
- N
60 min 60 min
11
(a) (b)
adult wall hung adult floor mounted water closet
water closet and children's water closet
Figure604.9.2 Wheelchair Accessible Toilet Compartment
604.9.3 Doors. Toilet Compartment doors, including door hardware, shall
corn with Section 404 except that if the approach is to the latch side of the
PYPP
Compartment door, clearance between the door side of the Compartment and
any m obstruction shall be 42 inches 1065 mminimum.The door shall be
self -dosing. A door pull complyingwith 404.2.E shall be laced on both sides of
9 P P
the door near the latch. Toilet compartment doors shall not swing into the
minimum required compartment.
604.9.3.1 Door Opening Location. The farthest edge of toilet Compartment
door opening shall be located in the front wall or partition or in the side wall or
Pe 9
partition as required by Table 604.9.3.1.
Table 604.9.3.1 - Door Opening location
Door Opening Location
jileasured Frown
imension
Front Wall or Partition
rom the side wall or partition
losest ro the water closet
6 inches (1420 ram) minimum
r
rom the side wall or partition
tlhest from the water closet
inches (100 ram) maximum
Side Wall or Partition
all -Hung Water Closet
:mm the mar wall
152 iinches(1320 mm) minimum
r
:mm the hoot wall or partition
H inches (100 ram) maximum
ide Wall or Partition
loon -mounted Water
loset
rom the rear wall
5 inches 395 mm) minimum
r
rom the hont wall or partition
el inches (100 mm) maximum
E
N�
V
(a) Front partition
Doorenarnm
t eg nw me
rsuren
MINIMUM two ar
are orri armem.
(c) Alternate Door Opening
Figure 604.9.3.1 Wheelchair Accessible Toilet Compartment Door Openings
604.9.4 Approach. Wheelchair accessible compartments shall be arranged for
left-hand or right-hand approach to the water closet.
604.9.5 Toe Clearance. Toe clearance for compartments primarily for children's
use shall comply with Section 604.9.5.2. Toe clearance for other wheel chair
accessible compartments shall comply with Section 604.9.5.1.
604.95.1. Toe Clearance at Compartments. The front partition and at least
one side partition shall provide a toe clearance of 9 inches (230 mm) min. above
the floor and extending 6 inches (150 mm) beyond the Compartment side face of
the partition, exclusive of partition support members.
EXCEPTIONS:
1. Toe clearance at the front partition is not required in a compartment greater
than 62 inches (1575 mm) in depth with a wall -hung water closet, or greater than
65 inches (1650 mm) in depth with a floor -mounted water closet. Toe clearance
at the side partition is not required in a compartment greater than 66 inches
(1675 mm) wide.
2. Toe clearance at the side partition is not required in a compartment greater
than 66 inches (1675 mm) in width.
artition
partition
6 min
sa10
11m,,n
min
2 0
12 min
30.
6 min
150
(a) (b) v (c)
elevation elevation plan
adult children
Figure 604.9.5 Wheelchair Accessible Toilet Compartment Tce Clearance
604.9.52 Toes Clearance at Compartments for Children's Use. Thefronl
partition and at least one side partition of compartments primarily for children's
use shall provide a toe clearance of 12 inches (305 mm) minimum above the
floor and extending 6 inches (150 mm) beyond compartment side face of the
partition, exclusive of partition support members.
EXCEPTIONS:
1. Toe clearance at the front partition is not required in a compartment greater
than 65 inches (1650 mm) in depth.
2. Toe clearance at the side partition is not required in a compartment greater
than 66 inches 1675 mm in width.
604.9.6 Grab Bars. Grab bars shall corn with Section 609. Side -wall grab
PY
bars complying with 604.5.1 located on the wall closest to the water closed, and
a rear wall grab bar complying with 604.5.2 shall be provided.
604.10 Ambulatory Accessible Compartments.
En
o
m 71 '
x 36
915 C
E
N �
V
Figure 604.8.2 Ambulatory Accessible Compartment
604.10.1 General. Ambulatory accessible compartments shall comply with
Section 604.10.
604.10.2 Size. The minimum area of an ambulatory accessible compartments
shall have a depth of 60 inches (1525 mm) minimum and 36 inches (915 mm) in
width.
604.10.3 Doors. Toilet compartment doors, including door hardware, shall
comply with Section 404, except that if the approach is to the latch side of the
compartment door, the clearance between the door side of the compartment and
any obstruction shall be 42 inches (1065 mm) minimum. The door shall be
self -dosing. A door pull complying with 404.2.6 shall be placed on both sides of
the door near the latch. Toilet compartment doors shall not swing into the
minimum required compartment area.
q
604.10A. Grab Bars. Grab bars shall corn with 609. A side -wall grab bar
PY
complying with 604.5.1 shall be provided on both sides of the Compartment.
605 Urinals
605.1 General. Urinals shall comply with 605
605.2 Height and Depth. Urinals shall be the stall -type or the wall -hung type
with the rim 17 inches (430 mm) maximum above the finish floor or ground.
Urinals shall be 13 1/2 inches (345 mm) deep minimum measured from the outer
face of the urinal rim to thei 131/2min
5
7 max
aan LI
(a) (b)
wall hung type stall type
Figure 605.2 Height and Depth of Urinals
605.3 Clear Floor Space. A dear floor or ground space Complying with 305
positioned for forwardapproach shall be provided.
605.4 Flush Controls. Flush controls shall be hand operated or automatic. Hand
operated flush controls shall comply with 309.
606 Lavatories and Sinks
606.1 General. Lavatories and sinks shall comply with 606.
606.2 Clear Floor Space. A dear floor space complying with 305.3, positioned
for a forward approach, and knee and toe clearance complying with 306 shall be
provided. The dip of the overflow shall no be Considered in determining knee and
toe clearance.
EXCEPTIONS:
1. A parallel approach complying with 305 shall be permitted to a kitchen sink in
a space where a Cook top or Conventional range is not provided and to wait bars.
2. A lavatory in a toilet room or bathing facility for a single occupant accessed
only through a private office and not for Common use or public use shall not be
required to provide knee and toe clearance.
3. A knee clearance of 24 inches (610 mm) minimum above the finish floor shall
be permitted at lavatories and sinks used primarily by children 6 through 12
years where the rim or Counter surface is 31 inches (785 mm) maximum above
the finish floor.
4. A parallel approach complying with 305 and centered on the sink shall be
P PP P 17 9
permitted at lavatories and sinks used primarily by children 5 years and younger.
S. The requirement for knee and too clearance shall not apply to more than one
bowl of a multi -bowl sink.
6. A parallel approach complying with Section 305 and centered on the sink,
shall be permitted at wet bars.
606.3 Height. The front of lavatories and sinks shall be 34 inches (865 mm)
maximum above the finish floor, measured to the higher of the rim or Counter
surface.
EXCEPTIONS: A lavatory in a toilet or bathing facility for a single occupant
accessed only through a private office and not for common use or public use
shall not be required to comply with 606.3.
606.4 Faucets. Controls for faucets shall comply with 309. Hand -operated
metering faucets shall remain open for 10 seconds minimum.
606.5 Lavatories with Enhanced Reach Range. Where enhanced reach
range is required at lavatories, faucets and soap dispenser controls shall have a
reach depth of 11 inches (280 mm) maximum or, if automatic shall be activated
within a reach depth of 11 inches (280 mm) maximum. Water and soap flow
shall be provided with a reach depth of 11 inches (280 mm) maximum.
606.5 Exposed Pipes and Surfaces. Water supply and drain pipes under
lavatories and sinks shall be insulated or otherwise Configured to protect against
contact. There shall be no sharp or abrasive surfaces under lavatories and sinks
609 Grab Bars
609.1 General. Grab bars in toilet facilities and bathing facilifies shall comply
with 609.
609.2 Cross Section. Grab bars shall have a cross section complying with
609.2.1 or 609.2.2.
609.2.1 Circular Cross Section. Grab bars with circular cross sections shall
have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51
mm) maximum.
609.22 Non- Circular Cross Section. Grab bars with non -circular cross
sections shall have a cross section dimension of 2 inches (51 mm) max. and a
perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)
maximum. 4-4.8 Denmeter
(a) (b)
Figure 60922 Grab Bar Non- Circular Cross Section
609.3 Spacing. The space between the wall and the grab bar shall be 1 1/2
inches (38 mm). The space between the grab bar and projecting objects below
and at the ends shall be 1 1/2 inches (38 mm) minimum. The space between the
grab bar and projecting objects above shall be 12 inches (305 mm) minimum.
EXCEPTION: The space between the grab bars and shower centrals, shower
fittings, and other grab bars above shall be permitted to be 1 1/2 inches (38 mm)
minimum.
W
F
S
Ea
R
Q
t/ran
�
O
F
(a) do)
U
projecting objects recessed objects
Figure 609.3 Spacing of Grab Bars N
609.4 Position of Grab Bars. Grab bars shall be installed in a horizontal Z
position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximumo
above the finish floor measured to the top of the gripping surface, except tiffs)
at water closets for children's use complying with 604.9, grab bars shall be
installed in a horizontal position 18 inches (455 mm) minimum and 27 inches
(685 mm) maximum above the finish floor measured to the top of the grippinc
surface. The height of the lower grab bar on the back wall of a bathtub shall
cornPY with 607.4.1.1 or 607.4.2.1.
609.5 Surface Hazards. Grab bars and any wall or other surfaces adjacent I
grab bars shall be free of sharp or abrasive elements and shall have roundec
edges.
609.6 Fittin s. Grab bars shall not rotate within their fittings.
9 9
609.7 Installation. Grab bars shall be installed in any manner that provides
gripping surface at the specified locations and that does not obstruct the
required clear floor space.
609.8 Structural Strength. Allowable stresses shall not be exceeded for
materials used when a vertical or horizontal force of 250 pounds (1112 N) is
applied at any point on the grab bar, fastener, mounfing device, or support ric
structure.
rn
w
Eo�
E�
N '
yCI
wN
U
H X Novi
�.�
corn
-
19
>
>
m E"
N
0
U
d
_
N Upn
L
C `.
0 of
am
U () U
L)
3
U coo
U - C
Y
>
LL
()
0 3
o
do
a
_
U
Carmel
(Zionsville), IN
10325 N. Michigan RD.
Carmel, IN 46032
Owner:
Chuys OPCO
1623 Tommy Road
Austin, TX. 78704
Ph: (512) 473-2783
Contact: Michael Hatcher
Architect:
Parkway CBA, LP
1000 Civic Circle
Lewisville, TX. 75067
Ph: (469) 322-3714
Project Contact: Bill Pounds, AIA
MEP Engineer
Diaelectic Engineering
310 W. 20th Street
Suite 200
Kansas City, MO 64108
Ph: (816) 997-9627
Contact: Joe Hillebrenner, P.E.
Structural Engineer:
Armstrong -Douglas
6060 N. Central Expressway
Suite 800
Dallas, TX 76206
Ph- (214) 237-7022
Contact: Scott Armstrong, P.E.
Landscape Architect:
Belle Fine, Inc.
4245 North Central Ex
toy.
Suite 501
Texas
Dallas14)865 75205
Contact: on Haug,
Contact: Kod Haug, ASLA, CLARB
Architect: Greg Klimko
Author
Checker
04-97221
p
Accessibility Standard
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
at State and local Codes
City of Central ((}}
lVgxrGfowwllgldtL
DATE: V.5/Lo/-1`J
A005