Loading...
HomeMy WebLinkAboutA141 Roof PlanBase bottom Packaged unit Fiberglass insulation Nailer strip Coutinuous flashing Cant strip Rigid insulation Roof curb f anchored to top of ro structure Cant strip Field room 2' above tc Roof insole Roofing material v Field of roofing n Roof curb /cl Roof Curb Isometric RELEASED FOR CONSTRUCTION Subject to compliance with all regulations )ofF at State and Local Codes '4"= City of Carmel Roof curb with 2x wood nailer top Flashing cement Corners wrap with fiber tape and flashing cement. Do not out off flaps TPO flashing membrane Extend 6' on to field of roofing 1'� Lead flashing at vent stack set in mastic and extend 4' min. on to field of roof. Roll lead flashing 1' min. down into pipe. Prime metal before stripping Plumbing vent stack TPO flashing membrane extend 12' min. from vent pipe TPO roofing Roof insulation Roof deck n LJ A141 Vent Stack Detail 1" = 1'-0" n A141 Scupper Isometric 1 1 /2" - 1'-0" Mechanics fasteners Base sheet TPO Wall covering - TPO membrane Scupper set in mastic and nailed at 3' o.c. Base ply - TPO flashing membrane Balance of roof membrane Base ply - TPO C----------------------------------------------------------------------------------------- General Notes - Roof Plan All work 0 be performed in strict accordance with the roofing manufacturer's recommendations. Reference specifications. 1 2 Verify that all areas am provided with positive drainage at 1/4' per foot minimum. 3 All cricketsdlashing to have a slope of 1/2' per fool minimum. 4 Provide crickets/flashing around curbed roof openings. 5 All cap flashing corner shall be welded. 6 Refer to mechanical, plumbing and electrical for locations of piping, curbs, vents, ducts, fans and other items on the roof surface. 7 All plumbing, mechanical and electrical lines to receive pillow blocks at 4'-0' apart maximum unless noted otherwise. For details refer to Plumbing. 8 Provide a secondary grease roof protection similar to Rooftop Solutions - G2 Grease Guard Rooftop Defense System for EF 41 through 45. Reference mechanical drawings. 9 Verify sins and locations of all openings, platforms, at. with respective contractors. 10 Do not penetrate paparet wall caps. 11 Provide roof jacks at all exposed roof penetrations. 12 All wall mounted and rooftop mechanical equipment will need to be screened from the public right-of-way/street view. Legend = Roof Plan Class 'A' TPO Membrane Roofing System to -Refer specification Bad Cricket- Rigid Tapered Insulation PAM Roof Walk Pad Slope Slope for 1/4' per foot minimum flaw to drain unless noted otherwise O OD Roof Crain and Overflow Crain -Referto detail on sheet A310 TD-X Mechanical Equipment -Ref. Mechanical / Roof Hatch Existing Roof Schedule ji Mark Manufacturer Senes/Descr. I Model Color RF-1 GAF EverGuardSingle Ply TPO TP060mil Membranc R-30 White Rigid Insulation RF-E Existingto remain Roof Deck rn V z odic aM> E _ g 'CEon Roof Deck Hurricane straps typ. at (4) corners (If required by code) Condenser equipment bolted to curb 1 1/2'x6' 10 Ga. gall straps each corners with (4) #12 self tapping screws (2) 2x8 wood (Treated) L2 1/2x2 1/2X3/16 coot #12 screws @ 12' o.c. 2xsupports Line bane rable Sealer urft elation Carmel (Zionsville), IN 10325 N. Michigan RD. Carmel, IN 46032 Owner: Chuys OPCO 1623 Toomy Road Austin, TX. 78704 Ph: (512) 473-2783 Contact: Michael Hatcher Architect: Parkway CBA, LP 1000 Civic Circle Lewisville, TX. 75067 Ph: (469) 322-3714 Project Contact: Bill Pounds, AIA MEP Engineer: Diaelectic Engineering 310 W. 20th Street Suite 200 Kansas City, MO 64108 Ph: (816) 997-9627 Contact: Joe Hillebrenner, P.E. Structural Engineer: Armstrong -Douglas 6060 N. Central Expressway Suite 800 Dallas, TX 76206 Ph' (214) 237-7022 Contact: Scoff Armstrong, P.E. Landscape Architect: Belle Firma, Inc. 4245 North Control Expy. Suite 501 Dallas, Texas 75205 Ph: (214) 865-7192 Contact: Kon Haug, ASLA, CLARB Architect: Greg Klimko 'ermlt 10.23.18 Description Date Author Checker 04-97221 Ira m Roof Plan DATE: V.5/LD/-1`J �M-Cu b 3• - 1'-0, A141