HomeMy WebLinkAboutE203 Floor Plan - Fire Alarm && SecurityCOMMUNICATION GENERAL NOTES Lu om BIG 1 TELEPHONE, DATA AND CATV CABLING SHALL BE PROVIDED BY OTHERS. 2 PROVIDED NYLON BUSHINGS ON ALL CONDUITS V � _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ �_ - yN _ ❑a ® o Q a FIRE ALARM GENERAL NOTES a r N Up, of uJ m 1 FIRE ALARM DEVICES ARE SHOWN FOR INTENT PURPOSES ONLY CONTRACTOR Z a is jU 2 SHALL PROVIDE A COMPLETE FIRE ALARM SYSTEM, COMPLYING WITH LOCAL ) (.1 I, CODES AND NFPA. WHERE REQUIRED, CONTRACTOR SHALL PROVIDE STAMPED O U CU - DRAWINGS SHCAMING DEVICE LOCATIONS AND CALCUTATgNS. U 2 FIRE ALARM CABLING SHALL BE INSTALLED IN CONDUIT FACTORY PAINTED RED. = O 35Cn 3 DUCT TYPE SMOKE DETECTORS SHALL BE FURNISHED AND WIRED BY FIRE O ALARM CONTRACTOR. INSTALLED IN DUCT BY MECHANICAL CONTRACTOR 4 PROVIDE DUCT OR AREA SMOKE DETECTOR (AS SHOWN ON PLANS( WITHIN S O U OF SMOKE DAMPERS, COMBINATION FIRE SMOKE DAMPERS AND FIRE ALARM CONTROL PANEL. U / I B HVAC SHUT DOWN RELAYS AT �L HVAC EQUIPMENT. I I AND CONTROL WIRING CONDUIT G FROM RELAY TO HVAC 6 EXISTING FIRE- ALARM EQUIPMENT MAINTAIN EXISTING EQUIPMENT FULLY OPERATIONAL UNTIL NEW EQUIPMENT HAS BEEN TESTED AND ACCEPTED. AS NEW EQUIPMENT IS INSTALLED, LABEL IT 'NOT IN SERVICE' UNTIL IT IS ACCEPTED. ONCE THE NEW SYSTEM IS INSTALLED, TESTED, AND ACCEPTED BY m THE OWNER OR THEIR REPRESENTATIVE, REMOVE LIBELS FROM NEW O EQUIPMENT AND LABEL EXISTING FIREALARM EQUIPMENT 'NOT IN SERVICE' UNTIL REMOVED FROM THE BUILDING. O O O O 0 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel (} �PINGIG kMWA� III II III III F� L� _ L I I I I j N) 0.1 FIRE ALARM AND SECURITY TRUE 00 00 ,01 de A m m 8 CONNECTING TO EXISTING EQUIPMENT VERIFYTHATEWSTING FIREALARM SYSTEM IS OPERATIONAL BEFORE MAKING CHANGES OR CONNECTIONS. 8A CONNECT NEW EQUIPMENT TO EXISTING CONTROL PANEL. BE PROVIDE ALL EQUIPMENT REQUIRED TO ALLOW NEW DEVICES TO BE INSTALLED AND OPERATIONAL. BC LANDLOARD APPROVED FIRE ALARM CONTRACTOR SHALL BE CONTRACTED TO MAKE ALL CHANGES TO LANDLORD FIRE ALARM SYSTEM, BD COORDINATE CONNECTION PONT AND TYPE WITH LANDLORD'S FIRE ALARM CONTRACTOR AND PROVIDE A COMPLETE SYSTEM AS REQUIRED BY CODES ANDLANDLORD. 9 MAINTAN A CLEAN,PROPER, SAFE WORK ENVIRONMENT PER OSHA AND LOCAL AW REQUIREMENTS. 10 AS NEW EQUIPMENT IS INSTALLED, LABEL IT 'NOT IN SERVICE UNTIL R IS ACCEPTED. 11 PROTECTIVE DUST CONVERS SHALL REMAIN ON ALL NEW DETECTORS UNTIL FINAL CONSTRUCTION CLEANUP IS COMPLETED. 12 EXPAND, MODIFY, AND SUPPLEMENT EXISTING EQUIPMENT AS NECESSARY TO EXTEND EXISTING FUNCTIONS TO THE NEW POINTS. NEW COMPONENTS SHALL BE CAPABLE OF MERGING WITH EXISTING CONFIGURATION WITHOUT DEGRADING THE PERFORMANCE OF EITHER SYSTEM. 13 PERFORM REACCEPTANCE TESTING TO VERIFY THE PROPER OPERATION OF ADDED OR REPLACED DEVICES AND APPLIANCES. IIIIIIIIIIIIIIIII III SPECIFICATIONS APPLY. THAT SHOWN HERON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWINGS; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENTAND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL Dialectic No. 113OD274 STATEOF Carmel (Zionsville), IN 10325 N. Michigan RD. Carmel, IN 46032 Owner: Chuy's DECO 1623 Tommy Road Ausgn,TX.78704 Ph: (512) 473-2783 Contact: Michael Hatcher Architect: Parkway C&A, LP 1000 Civic Circle Lewisville, TX. 75067 Ph: (469) 322-3714 Project Contact: Bill Pounds, AA MEP Enaineer: Dialecdc, Inc 210 W. 20th St. Suite 200 Kansas City, MO 64108 Ph: (816) 997-9627 Project Contact: Joe Hillebrenner, P.E. Structural Enalneer Armstrong -Douglas 6060 N. Central Expressway Suite 800 Dallas, TX 76206 Ph' (214) 237-7022 Contact: Scott Amistrong, P.E. Landscape Architect Belle Firma, Inc. 4246 Norh Control Expy. Suite 501 Dallas, Texas 75205 Ph: (214) 966-7192 Contact: Kon Haug, ASLA, CLARB BAPS 04-97221 FLOOR PLAN - FIRE ALARM & SECURITY DATE: V.5/LD/-1U Dialectic, Inc. T 816-997-9601 310 W 20th Street, Suite 200 F 816-997-9602 Kansas City, MO 64108 DialecticEng.com E203