Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E401 Electrical Schedules
=11:10190 160I&y'/IT, I 101WS4X0:1121 f 5 3 I HOME RUN TO PANEL. CIRCUIT NUMBERS, PHASE, NEUTRAL, AND GROUND CONDUCTORS INDICATED ALONG WITH ISOLATED GROUND CONDUCTOR IF APPLICABLE. PARTIALCIRCUIT. CONDUIT INSTALLED CONCEALED ABOVE CEILING OR IN WALL. — — — — CONDUIT INSTALLED CCNCEALED BELOW FLOOR SLAB OR UNDERGROUND. GROUND CONNECTION. ba y SINGLE POLE SWITCH, +3'-ID"OR AS NOTED. s3 THREE -WAYS WITCH,+3'-10'OR AS NOTED. 48.. yK KEY OPERATED SWITCH, +3'-l0'OR AS NOTED. WEATHERPROOF TOGGLE SWITCH, +3'-l0'OR AS NOTED. ♦sWP yP SINGLE POLE SWITCH WITH PILOT LIGHT, +3'-ID'OR AS NOTED. BE WALL MOUNTED OCCUPANCEY SENSOR, +3'-10"OR AS NOTED. ® CEILING MOUNTED OCCUPANCY SENSOR P$ CEILING MOUNTED INTERN OR DAYLIGHT HARVESTING PHOTOCELLSENSOR. © POWER PACK, INSTALLED ABOVE ACCESSIBLE CEILING. -e SIMPLEX RECEPTACLE, +18" OR AS NOTED, IS ISOLATED GROUND SIMPLEX RECEPTACLE, N8" OR AS NOIEO, DUPLEX RECEPTACLE, +18"OR AS NOTED, ISOLATED GROUND DUPLEX RECEPTACLE,+18" OR AS NOTED, QUADRUPLEX RECEPTACLE +18" OR AS NOTED. 49 ISOLATED GROUND QUAORUPLEX RECEPTACLE, N8" OR AS NOTED. -e=@ =9 GROUND FAULT INTERRUPTING RECEPTACLE, NB"ORA$NOTED, WP WP WE -e =@-9 WEATHERPROOF GROUND FAULT INTERRUPTING RECEPTACLE, +18" OR AS NOTED, T T T -e=@ -tJ TAMPER RESISTANT RECEPTACLE, +18"CRASNOTED, -e=@-9 RECEPTACLE INSTALLED HORIZONTALLY AT+18"OR AS NOTED. -9-0-ffj RECEPTACLE INSTALLED HORIZONTALLY,BOTTOMAT+6"ABOVE COUNTERTOP. RECEPTACLE INSTALLED FLUSH IN CEILING. ISOLATED GROUND RECEPTACLE INSTALLED FLUSH IN CEILING. SPECIAL RECEPTACLE, NEW STYLE AS NOTED,+18' DRAB NOTED. QQA KUSH KOM MOUNTED RECEPTACLE, LETTER INDICATES TYPE. OA POKE -THROUGH FLUSH FLOOR MOUNTED RECEPTACLE, LETTER INDICATES TYPE. OJ JUNCTION BOX. Q DISCONNECT SWITCH, TOP AT W'4"OR AS NOTED, DISCONNECT SWITCH PRWIDED WITH EQUIPMENT. Ip�LL I01 COMBINATI ON MOTOR STARTERDISCONNECT SWITCH FURNISHED BY MECHANICAL CONTRACTOR, INSTALLED BY ELECTRICAL CONTRACTOR. © EXTERIOR PHOTOCELL, INSTALLED ON ROOF FACING NORTH. ® CONTROL OR POWER RELAY, INSTALLED AS NOTED, El PUSHBUTTON, TOP AT M'£" OR AS NOTED. © DOOR BELL CHIMEM, WB 'OR AS NOTED. ® CONTROL TRANSFORMER, INSTALLED AS NOTED, T S C H THER MOSTAT, TEMPERATURE SENSOR, CARBON DIOXIDE SENSOR AND HUMIOI$TAT PROV IDED BY CONTRACTOR, +3'-10" CR AS NOTED. EDMECHANICAL ME CTR ICALLY OPERATED DAMPER, PROVIDED BY MECHANICAL CONTRR. ACTO 2 120 VOLT DUCT TYPE SMOKE DETECTOR. PROVIDED BY MECHANIC& CONTRACTOR -SCP1 SECURITY SYSTEM CONTROL PANEL, TOP AT 6'-0'. ❑K KEPYAD, +4 ' OR AS NOTED, Ot SECURIIYCAMERA. O MOTION DETECTOR, CEILING MOUNrEI. © GLASS BREAK SENSOR, CEILING MOUNTED. ❑D DO RCONTACTS. M� POWER COMPANY METER, TOP AT AEG OR AS NOTED. TRANSFORMER FLOOR MOUNTED OR SUSPENDED FROM STRUCTURE AS NOTED. Ts BRANCH CIRCUIT PANELBCARD. TOP AT W-cr' OR AS NOTED. ® DISTRIBUTION PANEL, TOP AT+ -D"OR AS NOTED. PLYWOOD PHONEBOARO. INSTALLED AS NOTED, DATA OUTLET,+18" WITH V CONDUIT TO ABOVE CEILING. NUMBER INDICATES QUANTITY �) OF SIGNAL CABLE DROPS AND CONNECT OAS. y TELEPHONE CUTLET,+W WITH 1" CONDUIT TO ABOVE CEILING. NUMBER INDICATES QUANTITY OF SIGNAL CABLE DROPS AND CONNECT ONG TELEPHONEOATA OUTLET, +18" WITH T' CONDUIT TO ABOVE CEILING. NUMBER INDICATES QUANTITY OF SIGNAL CABLE DROPS AND CONNECTIONS. FCP FIRE ALARM CONTROL PANEL, FLUSH MOUNTED, TOP AT+6'-0 F$A FIRE ALARM SYSTEM REMOTE ANNUNCIATOR, TOP AT+6'-0'. O MANUPL FIREARM PULL STATION, +3'-10'DER ADA, 9<1 FIRE ALARM HORN AND 75cd STROBE. +W' TO BOTTOM OF DEVICE PER ADA, �$ STROBE ONLY(]5M UNO).+W' TO BOTTOM OF DEVICE PER ADA. ® FIRE ALARM HOW AND 11 SM STROBE, CEILING MOUNTED. ® FIRE ALARM 115W STROBE, CEILING MOUNTED. O AREA TYPE PHOTOELETRIC SMOKE DETECTOR, CEILING MOUNTED, OR AS NOTED. O DOOR PUSHBUTTON, EDWARDS 417M ® DOORTRANSFORMER EDWARDS 4592(I1NSTALL MOUNTING PLATE, EDWARDS4593,IN 2-GANG BOX ABOVE DOORBELL ® DOORBELL, EDWARDS p3404G5(LOCATED 6' BELOW CEILING) GENERAL REFERENCESMOTATONS AC MOUNT DEVICE ABOVE TOP OF COUNTER TO BOTTOM OF DEVICE. +48" MOUNTING HEIGHT ABOVE FINISHED FLOUR TO CEWERUNE OF DEVICE. 03IE5 DETAIL OR SECT ON REFERENCE. F CODSERVICE EQUIPMENT DESIGNATI ON. QREVI SION DESIGNATION. eEQUIPMENT DESIGNATION. ABBREVIATIONS: AFFIXES ABOVE FINISHED FLOORGRADE. NEC AHJ AUTHORITY HAVING JURISDICTION. NFPA BAS BUILDING AUTOMATION SYSTEM. NL DNR DEPARTMENT OF NATURAL RESOURCES. NF EC ELECTRICAL CONTRACTOR. PA EM EMERGENCY. PC ETR EXISTING TO REMAIN, SM FA FIRE ALARM TYP MC FIRE PROTECTION CONTRACTOR. UL FSEC FOOD SERVICE EQUIPMENT CONTRACTOR. UNO GC GENERAL CONTRACTOR. UPS O MECHANICAL CONTRACTOR WP RELEASED FOR CONSTRUCTION NATIONAL ELECTRICAL CODE. NATIONAL FIRE PROTECTION ASSOCIATION. NIGHTLIGHT NONfUSEO. PUBLIC ADDRESS, PLUMBING CONTRACTOR SURGE PROTECTION DEVICE, TYPICAL, UNDERWRITERS LABORATORIES. UNLESS NOTED OTHERWISE. UNINTERRUPTIBLE POWER SUPPLY WEATHERPROOF. KITCHEN EQUIPMENT SCHEDULE SYl KITCHEN WUIPIN DESCRIPTION VOLTAGE CIRCUIT NAME LOAG III CONNECTION FFEOFIi NOTES PANEL CIRCUIT K01 AIRCUMAIN 12W-1P A2 14 612 VA 20A HARDWIRED (2)#12&Bp#12 G, 1c" 7 KO3] WPLK-IN MILLER POWER 12W-1P Al 24 400 VA 20A HARDWIRED (2)#12&(U#12 G, 12" - KO3.1 WALK-IN COMER POWER 12N-1P Al 24 400 VA 20A HARDWIRED OR#129(U#1201Q" - K03.1 WALK-IN GOOIER POWER 120V-1P AGO VA NA HARDWIRED D)1112&H)1112 G, la" - K032 WALK-IN CWLFR EVAPORATOR iWV-1P B 28 NOVA NA HARDWIRED (2)1I12&(1)1I12 G, 12' 45 K032 WALK-IN COOLER EVAPORATOR 12N-1P B 26 NOVA 20A HARDWIRED OR#129 HIM G, 12 4.5 K032 WALK-IN COOLER EVAPORATOR IMV-1P B 24 NOVA 20A HARDWIRED D)1112&H)#12 G, 1W" AS K032 WALK-IN GOOIER EVAPORATOR 12W-1P 9GGVA 20A HARDWIRED (2)#12&Bp#12 G, 1c" 45 K06 1DOOR FREEZER 120V-1P B2 15 1116VA 20A NEMAS-20R DGM2&112 G, TO" - K07 CUTTERMIIXER 120208V-3P S2 10,12,14 7566 VA 30A NEMWL21-30R BROS&(1p10 G, 1/4" - K08 FOOD PROCESSOR 12W-IF 32 8 84OVA 20A NEWS-NR (2)1112&(1)1112 G, la" K12 FLCCRMIXER 12W-1P M ] 1800VA 20A NEWS-2OR GS#12&(1)#12 G, 1c" K13 DOUGH ROUNDER 2081 Al 31,33,35 14 VA 20A NEW 1S20R OG#12& H n12 G, TV" K14 BAG N BOX 12pV-1P 32 9 360 VA 20A NEMA5-26R (2)#12& H n12 G, 12" K15 COOK & HOLD CABINET 2081 B2 4S 3016VA 30A NEW 6-3OR DR#10&HKI10 G, TO" K16 ICE MAKER 2081 At 40,42 2413 VA 20A DISCONNECT (2)#12&(ip11E G, la" 4 K16 ICE MAKER 2081 32 1,3 2413 VA 20A DISCONNECT (2)ti12&(1)1112 G, la" 4 KEG WEIGHWRAPSCPLE 12W-1P B2 5 24G VA 20A NEWS-2OR (2)#12&Bp#12 G, 1c" CG BAG SEALER 12pV-1P 83 1 NOVA 20A NEMA5-26R (2)#12& H n12 G, 1P" K24 TILTSgLIET 2081 83 2,4,6 11529VA 40A DISCONNECT (3)"&(1)#10 G, TA, 8 K24 TILTSKILIET 2081 B3 14,16.18 11529VA 40A DISCONNECT Gins &H)Ric G, smr 8 K28 GAS FRYER 12W-IF 33 3 204VA 20A NEMAS-20R (2)#12&(ip112 G, la" - K29 MOBILE FRYER FILTER 120V-IF 33 23 1200 VA 20A NEMA5-2OR (2)I112&(1)I112 G, la" 6 K29 MOBILE FRYER FILTER 12W-1P B3 25 1200 VA 20A NEMA5-2OR (2)#12&Bp#12 G, 1c" 6 K37 ELECTWCBWSTER HEATER 2081 MDP A 54040 VA 200A HARDWIRED BG#3A&(1ple Q 2" 4 K38 DISHWASHER 2081 B WAO.42 10800 VA GOA HARDWIRED (3W6&H)#ic G, T' VERIFY4 K41 WARMING&HOLDING CABINET 12W-IF 33 13 1920 VA 20A NEMAS-20R (2)#12&(ip112 G, la" 5 K43 STEAMER 208V-3P B3 20,22,24 12105VA GO NEW 155DR BSM&(1)I10 G, 3/4" - K45 MICROWAVE OVEN 2081 83 19,21 2975VA 20A NEW 6-2OR (2)#12& H n12 G, 12" - K46 SWDWHICHISALAD PREP 12V-1P 83 ] 660 VA 20A NEMA5-2OR (2)#12&(1)#12Q VT' 8 K47 GAS FRYER 12W-IF S3 15 204VA 20A NEMA5-2OR (2)#12&(ip11E G, la" 6 K47 GAS FRYER 12W-IF B3 11 204VA 20A NEWS-NR D)1112&H)1112 G, la" 6 KSO FOOD WARMER 12W-1P B3 9 756 VA 20A NEWS-2GR (2)#12&Bp#12 G, 1c" 6 K51 REFRGERATOR 12pV-1P 83 5 1308 VA 20A NEMA5-2OR (2)#12& H n12 G, 12" 6 K56 NACHOCHIPWARMER 120V-1P 82 27 1362 VA 20A NEMA5-2OR (2)#12 & (1)#12 G. 1W K56 NACOCHIPWARMER 12V-1P B2 20 1362 VA 20A NEMA5-2OR OR412&H#12 G. 12 K55 NACHOCHIPWARMER 120V-1P 32 29 1362 VA 20A NEMAS-20R (2)#12&(1)012 G. 12" K58 SANDWHICHAI PREP INV-1P 33 17 660 VA 20A NEMA5-2OR (2)I112&(1)012 G, 1W" - K62 PUMA PREP REFRIGERATOR 12W-iP 32 P 10SOVA 20A NEMAS-2OR (2)#12& H)/I12 G. 1Q K63 DUAL HEAT LAIR 2081 S! 16.18 33N VA 25A HARDWIRED DR#10&(H410 G, TO" - K64S 3W'ELL HOT TABLE 2081 At 37,39 3000 VA 20A NEW 6-2OR (2)#12&(ip11E G, la" K645 3WELL HOT TABLE 2081 M 10,12 3000 VA 20A NEW 6-2OR D)ti12&H)#12 G, la" K66 IMPINGEREXHAUST HOOD CNTRLS 12W-1P B 16 1000VA 20A HARDWIRED (2)#12&Bp#12 G, 1c" 1,2,3 K86] IMPNGEREXHAOST HOOD LIGHTS 12pV-1P B i8 1000VA 20A HARDWIRED (2)#12& H n12 G, 12" 1,2,3 K67 CONVEYORONEN 120208V-3P S3 26,28,30 7566 VA 30A NEMWL21-30R BROS&(1p10 G, 1/4" Kfi] COMEYOROVEN 12OaO8V-3P B3 8,10,12 7566 VA 30A NEMAUI1 R (4)NIO&H)NIO G, 1/4" K68 SNNDWHICHISPLAD PREP 12W-1P M W 660 VA 20A NEWS-2OR GS#12&(1)#12 G, 1c" - KIM SWDWHICHISALAD PREP 12pV-1P B2 M BBOVA 20A NEMAS20R (2)#12& H n12 G, TV" - K68 SNNDWHICHISALAD FREP 12W-IF 32 30 660 VA 20A NEMA5-2OR (2)#12&(ip11E G, 12" - KW TEABR:WER 12W-IF M 23 1200 VA 20A NEWS-2OR GS#12&Hp#12 G, lc" Kan SCAADISPENSER 12pV-1P 32 28 1200 VA 20A NEMAS20R (2)#12& H n12 G, TV" 9 Ran SCAADISPENSER 12pV-1P W 24 1200 VA 20A NEMA5-2OR (2)#12&(H#12 G, 12" 9 K107 COFFEE BREWER 120V-1P B2 25 1200 VA 20A NEMAS-20R DR#12&(U#120 TO" K108 COMBI WEN 2081 32 11,13 5533 VA 30A HARDWIIED (2)#10&(1)#10 G, 12" K114 BACKLINE EXHAUST HOW CN 1MS 120V-IF B 16 t000VA 20A HARDWIRED (2)I112&(1)I112 G, la" 1,2,3 K114] BACIQINE EXHAUST HOOD LIGHTS 120V-1P B i8 1000VA 20A HAROWIED (2)#12& H n12 G, TV" 1,2,3 K115 MONT INE EXHAUST HOOD CRIME 120V-1P B 16 1000VA 20A HARDWIRED QG112&HG112 G, TO" 123 K115.1 MONT INE EXHAUST HOOD LIGHTS 120V-IF B 18 1000VA 20A HARDWIRED GS#12&BpH2 G, 1W" 1,2,3 K117 ITORHUGRIDDUE 12W-1P B3 27 1200 VA 20A NEMAS-2OR GS912&(1)912 G, 1Q" K119 TCRTIOAEXHAUST HOOD 12pV-1P Al 10 1000VA 20A HARDWIRED OR#12&(U#12 G, TV" - K121 NACHO CAR 12W-IF B 2 756 VA 20A HARDAGED (2)012&(H#1E G, la" - K127 U/C REFRIGERATOR 12W-IF B2 31 66OVA 20A NEWS-NR D)1112&H)1112 G, la" K130 FROIEN BEVERAGE DISPENSER 208V-1P P2 T,8 2812VA 30A NEM4L6J0R Dp#10&(to1e G, 1c" 6 K130 FIOIEN BEVERAGE DISPENSER 208V-iP P2 ii,i3 2912VA 30A NEVAU6J3R (2)I110&(1)I110 G. 1Q 6 K132 NACHOCHIP DISPENSER 12W-IF B2 32 840VA 20A NEMA5-2OR (2p12&(1p12 G, 1R" - K135 BLENDER 12W-IF B2 33 1020 VA 20A NEMA5-2OR (2p112&(1p112 G, 1W" - K138 GLASS FROSTIER 12W-1P B2 34 984VA 20A NEMAS-2OR GS#12&(1)#12 G, 1Q" - K141 BOTRE COOLER 12pV-1P B2 35 Sol VA 20A NEMA5-2OR OR#129(U#12 G, TV" KITCHEN EQUIPMENT GENERAL NOTES: 1. ALL WORK TO BE PERFORMED IN FULL ACCORDANCE WITH ALL APPLICABLE LOCAL CODES RELATING TO INSTALLATION WIRING AND CONNECTION OF KITCHEN EQUIPMENT. 2. VEIRFY WITH ARCHITECT AND FOOD EQUIPMENT PROVIDER THE FINAL EQUIPMENT REQUIREMENTS BEFORE ORDERING MATERIAL. POSSIBLE LAST MINUTE CHANGES IN EQUIPMENT OR PERFORMANCE MAY AFFECT THE SCOPE OF WORK, 3. ALL 1" RECEPTACLES FOR THE BAR, FOOD PROCESSING AND SERVICE AREAS SHALL SE GFCI PROTECTED AT THE CIRCUIT BREAKER. 4, ALL KITCHEN AND SERVING AREA CONDUIT SHALL BE RIGID STELL OR LIQUID TIGHT FLEXIBLE METAL CONDUIT KITCHEN EQUIPMENT KEYNOTES 1. TO MEAGRE 1BOX ON TOP OF VENTILATOR FOR LIGHTING SWITCHES TO LIGHTS AND FANS FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR AND CONNECTED TO CIRCUIT. FURNISH AND INSTALL FLUORESCENT LAMPS AS REQUIRED. 2. FURNISH AND INSTALL VENT HOW FIRE EXTINGUISHING AND OTHER CONTROL WIRING, CONTACTORS, RELAYS AND OTHER DEVICES PER MANUFACTURER'S REQUIRMENTS. 3, FURNISH, INSTALL AND CONNECT CONTROL CIRCUITRY AS REQUIRED FOR CONNECTION OF GAS SOLENOID AND SHUNT TRIPS TO HOOD FIRE PROTECTION SYSTEM FOR AUTOMATIC SHUT-OFF UPON ALARM. 4, PROVIDE AND INSTALL DISCONNECT SWITCH OR BREAKER AHEAD OF EQUIPMENT AT THE OF INSTALLATION. 5, PROVIDE Sit 2, 10-C, FOR DEFROST WIRING TO AUTO -DEFROST TIMER IN COMPRESSOR. 6. PRWIDE 84" CORD AND 90 DEGREE PLUG. 7, INSTALL MICROSW ITCH AT DOOR FOR ON -OFF CONTROL PER MANUFACTURERS REQUIREMENTS. 8. MOUNT ON 24" HIGH UTILITY CHASE BETWEEN COOK LINE, SEE ARCHITECTURAL DETAIL. 9. PRWIDE WITH 3' WHIP LIGHTING FIXTURE SCHEDULE RMIRE TYPE MANUFACTURER CATALOG NUMBER DESCRIPTION LAMPS WATTS REMARKS A3 INTENSE LIGHTING HOUSING PART NUMBER 6" LED RECESSED DOWNLIGHT, 270CK Wm10-10V DIMMING 26W LED -2500 LUMENS 26 0-10V SS6WDR142784100 DIMMING REFLECTORPAATNUMBER IC630SRHZSFW AS WLIGHTING HOUSING 4" RECESSED LED CAN WmH CIFhR REFLECTOR AND WHITE 1OW LED -NO LUMENS 10 aDIMING 8215HA FINISH LEDMODULE 8766 SP AB CONTECH LIGHTING CM-8072M7-0A 25W TRACKHEAD BLACK FINISH LED 25 B TEXAS ROURESCENTS CIT48L-RF51W5014L-0MV30K SURFACE RUORESCENTWMH GASSFTED FIBERGLASS 51W LED-50M LUMENS 51 ENCLOSURE CB FURNISHED BYOWNER CHANDELIER (6)5W 30 A CC FURNISHED BYOWNER CHANDELIER (6)SW 30 A D TEXAS PLOURESCEWS JSR-081-40W54GGL-0MV-001< 4' STRIP LED WITH WIRE GUAM 4GW LED -SAGO LUMENS 40 EM EXITRONIX EXITTRWBBL EMERGENCY WALL PACK WITH BLACK FlNISH. SUITABLE FOR LED 12 DA.PNJETLOCATONS F FURNISHED BY MINE POW300SC SUSPENDED INCANDESCENT WmH SILVER BOWL LAMP WmH H)25WA19SB 0 CORDANDPLUG G FLAB W'P2CH15OPSQ-GD1NP2W WALL MOUNTED HID WITH DIE-CAST HOUSING, PRISMATIC (1)15OW FEW ISO PROVIDE REFRACTORAND WIRE GUARD WITH INTEGRAL PHOTOCELL I AMERICAN LIGHTING TARE LIGHT LED BAR TAPE LIGHT, 27WK ULTRA WARM WHTE 7.8W MR FOOT 0 MAX RUN 13 SP1-41W W-13 CONNECTORKITT--CONKIT DRNERIUMTDR150-24 J RP LIGHTING HOGGING 4'RECESSEDWALLWASH 26W CR. W 8202HA TRIM 87U Li RESTORATION HARDWARE FURNISHED BY OWNER MODERN TAPER GLASS SCONCE LED 13 M DESIGN LIGHTS 131-A125 41-FS6W5050L-DMN30K 2X4 RECESSED LED TROFFER LED 55 MIX DESIGN LIGHTS 131-A125-24LR56WSO5GL-0MVJ3K£M SAMEASTYPEMW/EMBRGENCYBALLAST LEDW/EMERGENCY 58 BACK UP OS BIG ASS SOLUTIONS PATIO CEILING FAN BLACK FINISH - 0 Pi FURNISHED BY OWNER PENDANT (Him 10 A P2 FURNISHED BY OWNER PENDANT (HieW 10 A P3 FURNISHED BY OWNER PENDANT (HwW 40 01 RAB LIGHTING HBLED13YA EXTERIOR LED BULLET FLOW WITH UNIT 13 W RAB LIGHTING HBLED13YA EXTERIOR LED BULLET RCCD WITH UNIT 13 R1 STARLITE FURNISHHED WrP AWNING CANCPYPUCKLIGHT 40W LED 40 R2 DESTINATION LIGHTING 57879E Y' ROUND BRONZE LOW PROFILE LED FLUSHMOINT 14W LED 14 S2 A.ERICAN LIGHTING ETISMS24- BK EXTERIOR STRING LIGHTS Barte LLON I.4WLED 8917 CLEAR 1AW LED SYPiCPREEN 1AW LED S917GRED 1.4WLED X1 BEST LIGHTING PRODUCTS EZ U-2R43-EM ILLUMINATED EXITSIGN WITH BATTERY UNIT. UNIVERSAL LED 4 MOUWING WITH RED LETTES AND BLACK FINISH X2 BEST LIGHTING PRODUCTS CX7EU-2R5 SAME AS TYPE'XT WITH (2) LED HEADS LED 6 Z JUNOLIGHTING SP03MU-WKNS1N W/7W-12SL AND MONO POINT SATIN CHROME WITH BLACK BUTTONS AND IT LED 75 TWSL LOW VOLTAGE EXTENSION WANDAND MONO 0INTADAPTER LIGHT FIXTURE SCHEDULE GENERA NOTES: 1. COLORED LAMPS FOR TYPE'SZ STRING LIGHTS SHALL CONSIST OF 70% FROSTED, S% RED, S% AMER, 8%ORANGE, 2% BLUE AND M GREEN. LAMPS SHAD BE'AMERICAN LIGHTING PREMIUMLEDS14 DIMMABLE 2. PROVIDE 20% SPARE LAMPS FOR EACH TYPE USED. 3, ALL I W ERIOR FLUORESCENT AND LED LANDS SHALL BE 2700K. ALL LED AND CR LAMPS SHALL BE DIMMABLE. 4, SUPPORT TYPES'ST AND'SZ STRING LIGHTS WITH SUSPENDED AIRCRAFT CABLE TO MAINTAIN SAG IN WINDY CONIDTIONS. 5, ALL PAR LAMPS SHALL BE HEAT RESI STANT, HARD GLASS TYPE. 6 FURNISH AND INSTAL LAMPS IN ALL LI UNIT FIXTURES INCLUDING OWNER FURNISHED FIXTURES AND KITCHEN EXHAUST HOOD FIXTURES. 7, FURNISH 400E FOREACH OFTYPES'STAND 'SZ STRING LIGHTS FOR SEASONAL UGHTINGTO BE INSTALLED. FOOTAGE SHALL REIN MULTIPLE SECTIONS(LENGTI OF EACH PER OWNER). 8. ALL RECESSED DOWNUGHTS SHALL BE IC RATED. LIGHT FIXTURE SCHEDULE NOTES: A. PROVIDE FACTORY MAXIMUM WATTAGE LABEL ON EACH SOCKETTO BE 1OW MAX • SPECIFICATIONS APPLY. THAT SHOWN HERON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWINGS; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL Dialectic NX 1130D274 STATE OF m o� OD n Nn N� U F J 6 m — MIN w ON U y 3 on r N Up) a�4E T> U U r0 3 UCU ma � O y O O 6U NP rv. 1Ir Carmel (Zionsville), IN 10325 N. Michigan RD. Carmel, IN 46032 Owner: Chuy's OPCO 1623 Toomy Road Austin, TX. 78704 Ph: (512) 473-2783 Contact: Michael Hatcher Architect: Parkway C&A, LP 1000 Civic Circle Lewisville, TX. 75067 Ph: (469) 322-3714 Project Contact: Bill Pounds, ALA MEP Enaineer, Dlalecdc, Inc 210 W. 20th St. Suite 200 Kansas City, MO 64108 Ph: (816) 997-9627 Project Contact: Joe Hillebrenner, P.E. Structural Enalneer Armstrong -Douglas 6060 N. Central Expressway Suite 800 Dallas, TX 76206 Ph' (214) 237-7022 Contact Scott Armstrong, P.E. Landscape Architect Belle Firma, Inc. 4245 North Central Expy. Suite 501 Dallas, Texas 75205 Ph: (214) 866-7192 Contact: Kon Haug, ASLA, CLARB Date ]PAVI, BY BAPS CI{CKET BY. - -F: I Mc 04-97221 ff ;P °nPIPV r 'Y 1' ^In O ELECTRICAL SCHEDULES Subject to compliance RAh all regulations EGERD NOTES: of State and meal Codes TO LIGHT FIXTURE SCHEDULE FOR SPECIFICATION AND INFORMATION ON ALL LUMINAIRES. TO SPECIFICATIONS AND PLAN NOTES FOR DETAILED DESCRIPTION OF ALL DEVICES SHOWN IN THIS SCHEDULE, PROVIDED BY WE City yoof Car lI NG HEIGHTS INDICATED ARE MEASURED FROM FINISHED FLOOR TO THE CENTERLINE OF THE DEVICE UNLESS NOTED OTHERWISE. �VIgW \B.KC)T1DA� CARTE: V.5/LD/-1U Dialectic, Inc. T 816-997-9601 310 W 20th Street, Suite 200 F 816-997-9602 Kansas City, MO 64108 DialecicEng.com E401