HomeMy WebLinkAboutHD1 Hood DrawingsNnnn INFnRMATTOW — .InhJF.4.RdR71> MAX' EXHAUST PLENUM TOTAL HOOD CONFIG. SWITCHES TOTAL RISER(S) END TO HOOD TAG MODEL LENGTH COOKING SUPPLY HOOD WIDTH LENG. HEIGHT DIA. CFM VEL. S.P. N0. TEMP. EXH. CFM CFM CONSTRUCTION END ROW QUANTITY LOCATION HOCD 1 LEFT SIDE 126 300 430 SS 1 PSP MISC-PSP 5, 3, Deg. 0 750 Where Exposed ALONE ALONE 5424 600 430 2 charbroller side ND-2-PSP-F l00' Deg. 2250 10, 21' 4' 2250 1543 -0,716' 1098 Where Exposed xp osed LEFT FRONT 5424 600 430 SS 3 charbroller side ND-2-PSP-F 9' 0' Deg. 2340 10, 22, 4' 2340 1532 -0.747' 1100 Where Exposed RIGHT FRONT 126 300 430 SS0 4 HOOD 2 RIGHT PSP MISC-PSP 5' 3' Deg. 750 Where Exposed ALONE ALONE 5424 600 430 SS 5 range side 8' 0' Deg. 1800 10' 17' 4' 1800 1525 -0.654' 1530 LEFT BACK ND-2-PSP-F Where Exposed 6 range side 5424 10' 0' 600 2250 10' 21' 4' 2250 1343 -0.716' 1710 430 SS RIGHT BALK ND-2-PSP-F Deg. Where Exposed 4824 600 430 SS 7 K 67 impinger TYPE 1 6' 0' Deg. 1500 10' 14' 4' 1500 1543 -0.636' 0 ALONE ALONE ND-2 Where Exposed 4824 700 430 SS I FAN FRONT LEFT 8 K117 VHB-ND 4' 0' Deg. 675 10' ll' 4' 675 884 -0.086' 0 1007 ALONE ALONE 1 LIGHT FACE Unnn rh7rn P Ale Trn AT wnnn nPT7n N.Q HOOD NO. TAG OPTION 2 charbroller side FINISHED BACK - GROUND/POLISH 120.00' Long INSULATION FOR BACK OF HOOD 3 charbroller side FINISHED BACK - GROUND/POLISH 108.00- Long INSULATION FOR BACK OF HOOD 5 range side FINISHED BACK - GROUND/POLISH 96.00' Long INSULATION FOR BACK OF HOOD 6 range side FINISHED BACK - GROUND/POLISH 120.00' Long INSULATION FOR BACK OF HOOD 7 K 67 impinger TYPE 1 JINSULATION FOR BACK OF HOOD 6 I K117 IFINISHEE BACK - GROUND/POLISH 48.00' Long FILTER(S) LIGHTS) UTILITY CABINETS) FIRE HOOD HOOD TAG EFFICIENCY @ 7 WIRE FIRE SYSTEM ELECTRICAL SWITCHES SYSTEM ANGIN NO. TYPE OTY, HEIGHT LENGTH MICRONS QTY. TYPE GUARD LOCATION SIZE TYPE SIZE MODEL # QUANTITY PIPING WGHT L HOOD 1 LEFT SIDE 0 NO 53 PSP LDS 2 charbroller side Cnp{rote Solo Filter 7 20' 16" 85% See Filter 6 Screw In Compact NO YES 52L Spec LBS 3 charbroller side Captrate Solo Filter 6 20' 16' 857. See Filter 6 Screw In Compact NO Right 12'x54'x24' SC-E221022FP 2 Light YES 604 Spec 2 Fan LBS 4 HOOD 2 RIGHT PSP 0 NO 53 LBS 5 range side Captrate Solo Filter 5 20' 16' 85% See Filter 6 Screw In Compact NO Left 12'x54'x24' Ansul P102 30/3.0/3.0/3.0/3.0 YES 63l Spec LBS 6 range side Captrate Solo Filter 7 20' 16° 85% See Filter 6 Screw In Compact NO YES 54l Spec LBS 7 K 67 Impinger TYPE l Captrate Solo Filter 4 20' 16, B5Y. See Filter 4 Screw In Compact NO YES 291 Spec. LBS 8 K117 4 L55 Series E26 NO NO 198 LBS PFPh'nPATFn RTTPPr.v Pr.FNrIM/.QI HOOD NO TAG PDS. LENGTH WIDTH HEIGHT TYPE RISER(S) WIDTH LENG. DIA CFM S.P. 1 HOOD 1 LEFT SIDE PSP Front 63' 12' 6' MUA e' 24' 375 0.101' MUA e' 24' 375 0.101' 2 charbroller side Front 120, 9' 6' MUA 6' 28' 366 0.110' MUA 6' 28, 366 0.110' MUA 6' 28' 366 0.110' 3 charbroller side Front 120, 9' 6' MUA 6' 28, 366 0d10' MUA 6' 28' 366 0.1109 MUA 6' 28' 366 0.110' 4 HOOD 2 RIGHT PSP Front 63' 12' 6' MUA 8' 24' 375 0.101' 8' 24' 375 0.101' 5 range side Front 308' 14° 6' 12" 28°765 0.189' tMUA 12' 28' 765 0.189' 6 range side Front 120' 14' 6' 12' 20' 570 OA76' 12' 20' 570 0.176' MUA 12' 20' 570 0.176' System Design Verification (SDV) If ordered, CAS Service will perform a System Design Verification (SDV) once all equipment has had a complete start up per the Operation and Installation Manual, Typically, the SDV will be performed after all inspections are complete. Any field related discrepancies that are discovered during the SDV will be brought to the attention of the general contractor and corresponding trades on site. These issues will be documented and forwarded to the appropriate sales office, If CAS Service has to resolve a discrepancy that is a field issue, the general contractor will be notified and billed for the work. Should a return trip be required due to any field related discrepancy that carrot be resolved during the SDV, there will be additional trip charges. During the SDV, CAS Service will address any discrepancy that is the fault of the manufacturer. Should a return trip be required, the general contractor and appropriate sales office will be notified. There will be no additional charges for manufacturer discrepancies, 1/2' - l3 TPI MAN 5 MININ ND STEEL HEX NUTS I/e - n TPI MAX 5 ammuro STEEL FLL-THRM Vr - 13 1P1 STEEL HEX MIT 1/Y MADE 5 (HINDewa STEEL MT WASHER yr - GRADE STEEL yr MADE STEM - STEEL UV - MAN STEEL FULL LENGTH HANGING ANGLE (HARDWARE BY INSTALLER) STEEL NEX WT HOOD CORNER HANGING ANGLE (HARDWARE BY INSTALLER) HGoS CORNER HANGING ANGLE (WEIWT BEARING ANCHOR PRINT FOR Wm 1/a• rRALE S1EEL ASSEMBLY SCREW IN COMPACT FLUORESCENT BULB, L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE SUPPLY RISER WITH VOLUME DAMPER 1 23.5% OPEN STAINLESS L STEEL PERFORATED PANEL 3/V 6' HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4' OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. rZ1aLIEUA 12' 54' EQUIPMENT BY OTHERS SPFCIFICATION, CAPTRATF* GREASE-STOPwSOLO FILTER THE CAPTRATE GREASE -STOP SOLO FILTER IS A SINGLE -STAGE FILTER FEATURING A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD 2-INCH DEEP HOOD CHANNEL(S). UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO COMPONENTS WHEN ASSEMBLED. GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 35% GREASE PARTICLES SEVEN MICRONS IN SIZE AND LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. THE CAPTRATE GREASE -STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05 EFFICIENCY V5. PAR'rICL8 DNN015R PBESSUAEDROP VS PIAW RAM 9 IN g9 uo AID 6110 N� PdflT1CL8 DIAM6rPil guv) � CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH,. NFPA 496 NSF STANDARD #2 UL STANDARD #1046 INT. MECH. CODE CIMM ULC-S649 FLOW F1L15 (d'm) iw SCREW IN COMPACT FLUORESCENT BULB, L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL 54, AND SHOCK RESISTANT GLOBE SUPPLY RISER WITH VOLUME DAMPER 235% MEN STAINLESS 2 3/I' STEEL PERFORATED PANEL SEE HOOD T LE G. EOLTIPMENT BY OTHERS SECTION VIEW - MODEL 5424ND-2-PSP-FS HOOD - #3 & 4 (range side) HOOD - $1 & 2 (charbroiler side) 9' i {Iilllllp 3 81' REVISIONS 1 M� 1 M M z cu H (y) CD _J 0 LLI r z Q H DATE: 10/19/2018 DWCL#: 3343711 DRAWN BY: SCALE: 3/41, = 1'—o" MASTER DRAWING SHEET NO. m q sm USM E1 o� n �1 N r 2" U F �m J -rN m a n ER U y On 3 o r N cp uJ m of a i UU U0� Y5;a U o3a c) U Carmel (Zionsville), IN 10325 N. Michigan RD. Carmel, IN 46032 Owner: Chu)'s OPCO 1623 Tommy Road Austin, TX. 78704 Ph: (512) 473-2783 Contact: Michael Hatcher Architect: Parkway CBA, LP 1000 Civic Circle Lewisville, TX. 75067 Ph: (469) 322-3714 Project Contact: Bill Pounds, AIA MEP Enaineer Diaelectic Engineering 310 W. 20th Street Suite 200 Kansas City, MO 64108 Ph: (816) 997-9627 Contact: Joe Hillebrenner, P.E. structural Engineer: Armstrong -Douglas 6060 N. Central Expressway Suite 800 Dallas, TX 76206 Ph- (214) 237-7022 Contact: Scoff Armstrong, P.E. Landscape Architect: Belle Firma, Inc. 4245 North Central Expy. Suite 501 Dallas, Texas 75205 Ph: (214) 865-7192 Contact: Kon Haug, ASI A, CI.ARB Architect: Greg KlimW N.S. S J. 04-97221 Hood Drawings RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City ofCarmel (} �Nq�\axdllal� DATE: 11.1.5/Lo/-IU HD1