Hood
ock
-r
9
1v
—
g
24.001F_
12L
L--J
Hood
It 7 (K 67 InPinger
TYPE
D Jab w
3343711
�I, Nodetl
ND-2 Size,
4gth 6' V
NOTES
- FIELD PIPE DROPS AS SHOWN
SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS
- RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING,
SALAMANDERS, ETC.
- MAXIMUM 9 ELBOWS IN SUPPLY LINE,
- MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE.
- IF APPLICABLE, PRE -PIPED CHARBROILER DROPS ARE SHIPPED LOOSE.
- FACTORY PIPING EXTENDS A MAXIMUM OF 6' ABOVE THE TOP OF THE HOOD,
- APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE
SIZE, NGT THE OVERALL APPLIANCE SIZE,
- THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS
Job #I 3343711
Job Name, CHUY'S CARMEL IN #3343711
Drawn ByyI
System Sizes ANSUL-3,0/3.0/3,0/3.0/3,0 Total FP required 47
Hood # 2 10' 0.00' Long x 54' Wide x 24' High
Riser # 1 Size, 10' x 21'
Hood # 2 Metal Blow -Off Caps Included,
Hood # 3 9' 0,00' Lon? x 54' Wide x 24' High
Riser # 1 SIzeI 10' x 22'
Hood # 3 Metal Blow -Off Caps Included,
Hood # 5 8' 0,00' Longg x 54' Wide x 24' High
Riser # 1 SIzeI 10' x 1 0
Hood # 5 Metal Blow -Off Caps Included,
Hood # 6 10' 0.00' Longg x 54' Wide x 244 High
Riser # 1 SIzeI 10' x 21'
Hood # 6 Metal Blow -Off Caps Included,
Hood # 7 6' 0,00' Lon? x 48' Wide x 24' High
Riser # 1 SIzeI IV x 14'
Hood # 7 Metal B(ow-Off Caps Included,
LEGEND - FIRE CABINET ANSUL SYSTEM
1A 1.5 GALLON TANK
1
LU
m
q
sm
oom
O �
47
Np^i
X
F
rn
W
J
J
N�
-
m
nrjN
U
S.No
u
N
UM
Q
J
of
u
o
a
% V U
Q
}
Uho
a
'3T
U
REVISIONS
SORIPLION
DALE:
�
O y
Z
U
1B
3 GALLON TANK
2
OEM AUTOMAN RELEASE
rI
3
OEM REGULATED RELEASE
I\
4
OEM REGULATED ACTUATOR
CY)
5
ANSULEX LIQUID AGENT (3 GAL.)
6
ANSULEX LIQUID AGENT (1.5 GAL.)
7
CARTRIDGE (101-20)
8
CARTRIDGE (101-10)
M
9
CARTRIDGE (101-30)
�$
9A
CARTRIDGE (LT-A-101-30)
93
DOUBLE TANK CARTRIDGECu
10
TEST LINK
Z Cu
11
DOUBLE MICROSWITCH
12
HOSE ASSEMBLY
CD
1100
DUCT NOZZLE C430913)
_J kD
2W
DUCT NOZZLE C419337)
J V
1W
NOZZLE ASSEMBLY (419336)
1F
NOZZLE ASSEMBLY (419333)
1N
NOZZLE ASSEMBLY (419335)
z
1/2N
NOZZLE ASSEMBLY (419334)
3N
NOZZLE ASSEMBLY (419338)
L)
245
NOZZLE ASSEMBLY (419340)
230
NOZZLE ASSEMBLY (419339)
2120
NOZZLE ASSEMBLY (419343)
LL1
290
NOZZLE ASSEMBLY (419342)
5
260
NOZZLE ASSEMBLY (419341)
00f
28
DETECTOR BRACKET
= Q
29
LOW TEMP FUSIBLE LINK
30
HIGH TEMP FUSIBLE LINK
MGV
MECHANICAL GAS VALVE
EGV
ELECTRICAL GAS VALVE
DATE 10/19,
34
REMOTE MANUAL PULL STATION
S
SWIVEL ADAPTOR
DWG #:
3343711
DRAWN
BYI
SCALE:
3/411 = 1'-011
F:7
MASTER DRAWING
SHEET NO.
4
Carmel
(Zionsville), IN
10325 N. Michigan RD.
Carmel, IN 46032
Owner:
Chuys OPCO
1623 Tommy Road
Austin, TX. 78704
Ph: (512) 473-2783
Contact: Michael Hatcher
Architect:
Parkway CBA, LP
1000 Civic Circle
Lewisville, TX. 75067
Ph: (469) 322-3714
Project Contact: Bill Pounds, AIA
MEP Enaineer
Diaelectic Engineering
310 W. 20th Street
Suite 200
Kansas City, MO 64108
Ph: (816) 997-9627
Contact: Joe Hillebrenner, P.E.
Structural Engineer:
Armstrong -Douglas
6060 N. Central Expressway
Suite 800
Dallas, TX 76206
Ph- (214) 237-7022
Contact: Scoff Armstrong, P.E.
Landscape Architect:
Belle Firma, Inc.
4245 North Central Expy.
Suite 501
Dallas, Texas 75205
Ph: (214) 865-7192
Contact: Kon Haug, ASLA, CLARB
Architect: Greg KlimW
N.S.
S J.
04-97221
Hood Drawings
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City offCamlel (}
�Nq�\axc�lall�
DATE: Vi-1`J
HD4