2`-
1� 22 14 -j
24A4 T
DUCTWORK BETWEEN
EXHAUST RISER ON HOOD
AND FAN (BY OTHERS)
L 19
DUCTWORK BETWEEN
EXHAUST RISER ON HOOD
AND FAN (BY OTHERS)
FEATURES:
- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS)
- ROOF MOUNTED FANS
- RESTAURANT MODEL
- UL705 AND UL762 AND ULC-S645
- VARIABLE SPEED CONTROL
- INTERNAL WIRING
- WEATHERPROOF DISCONNECT
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE)
- HIGH HEAT OPERATION 300-F (149•0
- GREASE CLASSIFICATION TESTING
NORMAL TEMPERATURE TEST
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING AIR AT 300•F (149-C)
UNTIL ALL FAN PARTS HAVE REACHED
THERMAL EQUILIBRIUM, AND WITHOUT ANY
DETERIORATING EFFECTS TO THE FAN WHICH
WOULD CAUSE UNSAFE OPERATION.
ABNORMAL FLARE-UP TEST
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING BURNING GREASE VAPORS
AT 600•F (316•C) FOR A PERIOD OF
15 MINUTES WITHOUT THE FAN BECOMING
DAMAGED TO ANY EXTENT THAT COULD CAUSE
AN UNSAFE CONDITION.
OPTIONS
GREASE BOX.
ECM WIRING PACKAGE -EXHAUST - MANUAL
OR 0-10VDC REFERENCE SPEED CONTROL
(NIDEC MOTOR).
FEATURES:
- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS)
- ROOF MOUNTED FANS
- RESTAURANT MODEL
- UL705 AND UL762 AND ULC-S645
- VARIABLE SPEED CONTROL
- INTERNAL WIRING
- WEATHERPROOF DISCONNECT
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE)
- HIGH HEAT OPERATION 300-F (149'G
- GREASE CLASSIFICATION TESTING
NORMAL TEMPERATURE TEST
r2 EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING AIR AT 300-F (149•C)
UNTIL ALL FAN PARTS HAVE REACHED
THERMAL EOUILIBRIIIM, AND WITHOUT ANY
DETERIORATING EFFECTS TO THE FAN WHICH
WOULD CAUSE UNSAFE OPERATION.
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING BURNING GREASE VAPORS
AT 600-F (316'0 FOR A PERIOD OF
15 MINUTES WITHOUT THE FAN BECOMING
DAMAGED TO ANY EXTENT THAT COULD CAUSE
AN UNSAFE CONDITION.
OPTIONS
GREASE BOX.
20'
22'
23'
VENTED
CURB
20 GAUGE
STEEL
CONSTRUCTION
3' FLANGE
` ` ROOF OPENING
J 22 1/2
22 1/2 DIMENSIONS
19
20 GAUGE
STEEL
CONSTRUCTION
�3' FLANGE
` ROOF OPENING
\ 19 DIMENSIONS
19 �
FAN #7 DU30HFA - EXHAUST FAN #7 DU30HFA - EXHAUST FAN (DISHWASXERC)
FEATURES:
- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS)
25 1/2 - ROOF MOUNTED FANS
- UL705
- VARIABLE SPEED CONTROL
- INTERNAL WIRING / 119 1/2•
- WEATHERPROOF DISCONNECT 19 1/2'
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE)
OPTIONS I VENTED
25 1/4' 115-BDD DAMPER. CURB
IB v2• 22'
DACKDRAFT DAMPER INSTALLATION
AIR FLOW
4 BACKDRAFT DAMPER 20 GAUGE
STEEL
L CONSTRUCTION
--16'
2r
(ROOF OPENING)
m
q
EO�
E�
4�
Np^i
X
~
rn
W
J
J
N�
-
m
prjN
U
�.No
u
N
(Y
UM
Q
J
of
u
m
�
a
% V U
Q
}
Uho
3
UCU
REVISIONS
U
a
�j3T
SCRIPLON
DATE'
O y
Z
U
3'
FLANGE
M
ROOF OPENING
U
\
/ 16'
DIMENSIONS
Nt
16'
J
(y)
z CU
H \ 1
CD
J lD
LLJ
� z
Q H
1) J
LLJ
Q
U U
DATE: 10/19/2018
DWG.S:
3343711
DRAWN
BY:
SCALE:
3/411 = 1'-011
MASTER DRAWING
SHEET NO,
7
Carmel
(Zionsville), IN
10325 N. Michigan RD.
Carmel, IN 46032
Owner:
Chuyrs OPCO
1623 Tommy Road
Austin, TX. 78704
Ph: (512) 473-2783
Contact: Michael Hatcher
Architect:
Parkway CBA, LP
1000 Civic Circle
Lewisville, TX. 75067
Ph: (469) 322-3714
Project Contact: Bill Pounds, AIA
MEP Enaineer
Diaelectic Engineering
310 W. 20th Street
Suite 200
Kansas City, MO 64108
Ph: (816) 997-9627
Contact: Joe Hillebrenner, P.E.
Stmctural Enalneer:
Armstrong -Douglas
6060 N. Central Expressway
Suite 800
Dallas, TX 76206
Ph- (214) 237-7022
Contact: Scoff Armstrong, P.E.
Landscape Architect:
Belle Firma, Inc.
4245 North Central Expy.
Suite 501
Dallas, Texas 75205
Ph: (214) 865-7192
Contact: Kon Haug, ASLA, CLARB
Architect: Greg KlimW
N.S.
S J.
04-97221
Hood Drawings
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City
offCamlel (\��
' N"1000091DJV.�
DATE: 11.1.5/Lo/-1U
HD7