Loading...
HomeMy WebLinkAboutL3.01 - Irrigation Plan (2018 12 22 City Comment)IN THE EVENT THAT NO EXISTING BUBBLER ZONES EXISTING IRRIGATION ARE AVAILABLE, INSTALL TO REMAIN, REPAIR AND NEW BUBBLER VALVES REPLACE AS NECESSARY DUE TO CONSTRUCTION, TYP. ' LOCATE AND CONNECT TO ' EXISTING BUBBLER ZONE ® _ FOR NEW TREES 4111 ADD 4 NEW EXISTING IRRIGATION HEAD TO REMAIN, REPAIR AND • REPLACE AS NECESSARY DUE TO CONSTRUCTION, TYP. 1• Q 1 rat EXISTING 3/4.i IX SLEEVE 1/2• f _ 1 1/ • i . 19 3/4• 1 2 \ RAINBIRD ESP NIX MODULAR CONTROLLER _J N1TH RAIN AND FREEZE SENSORS 1• VERIFY LOCATION AND POWER SUPPLY DRIP < 00 RUN EXISTING ZONE PARING TO IF NEW CONTROLLER 1a EXISTING DRIP 3" SLEEVE 1 1 /A• f3 ® LOCATE AND CONNECT TO _ _ _BORE E i & 0 0 0 EXISTING MAINLINE AND WIRING INNINNININ.J.3 EXISTING IRRIGATION IN THE EVENT THAT NO LOCATE AND CONNECT TO TO REMAIN, REPAIR AND EXISTING BUBBLER ZONES EXISTING BUBBLER ZONE REPLACE AS NECESSARY ARE AVAILABLE, INSTALL FOR NEW TREES DUE TO CONSTRUCTION, TYP. NEW BUBBLER VALVES IN THE EVENT THjNOLOCATE AND CONNECT TO EXISTING BUBBLEEXISTING BUBBLER ZONE iARE AVAILABLE, FOR NEW TREENEW BUBBLER V 0 O LOCATE AND CONNECT TO EXISTING MAINUNE AND WIRING EXISTING IRRIGATION TO REMAIN, REPAIR AND REPLACE AS NECESSARY DUE TO CONSTRUCTION, TYP. n FOR LOCATE AND CC EXISTING BUBBL I IN THE EVENT N to AVAN ea c ZONE NEW PLANTS L.I.C. TO MAINTAIN OPERATION OF EXISTING SYSTEM DURING NEW CONSTRUCTION AND RENOVATION OF PAD SITE. AS BUILT DRAWINGS WERE NOT PROVIDED. USE EXISTING SLEEVES WHERE POSSIBLE TO AVOID BORING 13 #2 IN THE EVENT THAT NO LOCATE AND CONNECT TO EXISTING BUBBLER ZONES EXISTING BUBBLER ZONE ® 0 19 ARE AVAILABLE, INSTALL FOR NEW TREES — NEW BUBBLER VALVES EXISTING IRRIGATION TO REMAIN, REPAIR AND REPLACE AS NECESSARY DUE TO CONSTRUCTION, TYP. 1 1/4• NO i-0 CONTRACTOR SHALL PROVIDE LABOR AND MATERIALS TO .YV REMOVE THE ABANDONED IRRIGATION SYSTEM AT THE BUILDING PAD, INCLUDING HEADS, VALVE BOXES, AND VISIBLE LINES / CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS OF THE EXISTING IRRIGATION ALONG PERIMErER PARKING 02 WNER n IF D AND ED OR MIS NG. N. MICHIGAN ROAD SLEEVING NOTES 1. SLEEVES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. 2. SLEEVE MATERIAL SHALL BE SCHEDULE 40 PIPE, SIZE AS INDICATED ON PLAN. 3. CONTRACTOR SHALL LAY SLEEVES AND CONDUITS AT TWENTY-FOUR (24") INCHES BELOW FINISH GRADE OF THE TOP OF PAVEMENT. 4. CONTRACTOR SHALL EXTEND SLEEVES ONE (1') FOOT BEYOND EDGE OF ALL PAVEMENT. 5. CONTRACTOR SHALL CAP PIPE ENDS USING PVC CAPS. 6. CONTRACTOR SHALL FURNISH OWNER AND IRRIGATION CONTRACTOR WITH AN 'AS -BUILT' DRAWING SHOWING ALL SLEEVE LOCATIONS. IRRIGATION NOTES 1. THE IRRIGATION CONTRACTOR SHALL COORDINATE INSTALLATION OF THE IRRIGATION SYSTEM WITH THE LANDSCAPE CONTRACTOR SO THAT ALL PLANT MATERIAL WILL BE WATERED IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. 2. ALL SPRINKLER EQUIPMENT NUMBERS REFERENCE THE RAINBIRD EQUIPMENT CATALOG UNLESS OTHERWISE INDICATED. 3. TEN DAYS PRIOR TO START OF CONSTRUCTION, IRRIGATION CONTRACTOR SHALL VERIFY STATIC WATER PRESSURE. IF STATIC PRESSURE IS LESS THAN 65 P.S.I., NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY. DO NOT WORK UNTIL NOTIFIED TO DO SO BY OWNER. 4. SLEEVES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. SLEEVE MATERIAL SHALL BE SCHEDULE 40, SIZE AS INDICATED ON PLAN. REFER TO SLEEVING NOTES. 5. ALL MAIN LINE AND LATERAL LINE PIPING IN PLANTING AND LAWN AREAS SHALL HAVE A MINIMUM OF 12 INCHES OF COVER. ALL PIPING UNDER PAVING SHALL HAVE A MINIMUM OF 18 INCHES OF COVER. CONTRACTOR TO VERIFY LOCAL FREEZE DEPTHS AND ADJUST DEPTH OF COVER ACCORDINGLY. 6. LAWN SPRAY HEADS SHALL BE RAINBIRD 1804 INSTALLED PER DETAIL SHOWN. 7. ROTOR HEADS SHALL BE RAINBIRD 5000 INSTALLED PER DETAIL SHOWN. (WITH BUILT-IN CHECK VALVE) 8. NOZZLES SHALL BE RAINBIRD PLASTIC, UNLESS OTHERWISE NOTED. IRRIGATION CONTRACTOR SHALL SELECT THE PROPER ARC AND RADIUS FOR EACH NOZZLE TO ENSURE 100% AND PROPER COVERAGE OF ALL LAWN AREAS AND PLANT MATERIAL. NO WATER SHALL SPRAY ON BUILDING. 9. ALL NOZZLES IN PARKING LOT ISLANDS AND PLANTING BEDS SHALL BE LOW ANGLE NOZZLES TO MINIMIZE OVER SPRAY ON PAVEMENT SURFACES. 10. ELECTRIC CONTROL VALVES SHALL BE RAINBIRD PEB INSTALLED PER DETAIL SHOWN. SIZE OF VALVES AS SHOWN ON PLAN. VALVES SHALL BE INSTALLED IN VALVE BOXES LARGE ENOUGH TO PERMIT MANUAL OPERATION, REMOVAL OF SOLENOID AND / OR VALVE COVER WITHOUT ANY EARTH EXCAVATION. 11. ALL 24 VOLT VALVE WIRING TO BE OF 14 GAUGE SINGLE CONDUCTOR. ALL WIRE SPLICES ARE TO BE PERMANENT AND WATERPROOF. 12. AUTOMATIC CONTROLLER SHALL BE INSTALLED AT LOCATION SHOWN, POWER L20V) SHALL BE LOCATED IN A JUNCTION BOX WITHIN FIVE (5') FEET OF CONTROLLER, LOCATION BY OTHER TRADES. RAIN AND FREEZE SENSORS SHALL BE INSTALLED WITH EACH CONTROLLER. \ IN THE EVENT THAT NO \ EXISTING BUBBLER ZONES ARE AVAILABLE, INSTALL NEW BUBBLER VALVES \ LOCATE AND CONNECT TO E%ISTING BUBBLER ZONE \ FOR NEW TREES \ TO \ 16 ZONE ® \ \ \ 0 IRRIGATION LEGEND 0 RAINBIRD 1804 POP-UP LAWN HEAD •MP HUNTER MP ROTATOR NOZZLE C RAINBIRD 5000 ROTARY FC • RAINBIRD 5000 ROTARY PC ® RAINBIRD BUBBLER (2 PER TREE, TYP.) RAINBIRD FEB SERIES ELECTRIC VALVE CONTROLLER, SIZE AS INDICATED .N ,W WATER METER, SIZE AS INDICATED WITH D.G.A., SIZE AS INDICATED PVC SCHEDULE 40 SLEEVING —' PVC CLASS 200 MAINLINE PVC CLASS 200 LATERAL LINE XXX VALVE SIZE XXX GPM NETAFIM TECHLINE#TLDL6-1210 (18" LATERAL SPACING, 12" EMITTER SPACING) PVC LATERAL PIPING SIZED REQUIRE INSTALL ALL EQUIPMENT ACCORDING D 10 MANUFACTURERS SPECIFICATIONS NETAFIM TECHLINE#TLDL6-1210 (18" LATERAL SPACING, 12" EMITTER SPACING) PVC LATERAL PIPING SIZED AS REQUIRED INSTALL ALL EQUIPMENT ACCORDING TO MANUFACTURERS SPECIFICATIONS NETAFIM DISC FILTER #DF100-080 XXX NETAFIM PRESSURE REGULATOR #PRV15025 DRIP INSTALL ALL EQUIPMENT ACCORDING TO MANUFACTURERS SPECIFICATIONS BUBBLER PIPING CHART NUMBER OF BUBBLERS SIZE OF PIPE 1 5 '/u" 6 10 3/f' 11-20 1" 21 -30 1Y4" 31 - 40 1 A" LU n grn E G_ W I h� Yry INN. - IN U � J NN Ti D' : m • a` �� Z U O U a Ux o n � a U O U Carmel (Zionsville), IN 10325 N. Michigan RD. Carmel, IN 46032 Owner: Chugs OPCO 1623 Toomy Roatl Austin, TX. 78704 Ph: (512) 473-2783 Contact: Michael Hatcher Architect Parkway CBA, LP 1000 Civic Circle Lewisville, TX. 75067 Ph: (469) 322-3714 Project Contact: Bill Pounds, AIA MEP Engineer: Diaelectic Engineering 310 W. 201h Street Suite 200 Kansas City, MO 64108 Ph: (816) 997-9627 Contact: Joe Hillebrenner. P.E. structural Engineer Armstrong -Douglas 6060 N. Central Expressway Suite 800 Dallas, TX 76206 Ph' (214) 237-7022 Contact: Scott Armstrong, P.E. Landscape Architect: Belle Firma, Inc. 4245 North Central Expy. Suite 501 Dallas, Texas 75205 Ph: (214) 865-7192 Contact: Kori Haug, ASLA, CLARB 8 Permd 10.23.18 Description Date JJW JJW 04-97221 NINE IRRIGATION PLAN RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Carmel '"It, DATE: V3/LD/-1`J SCALE: 1 = 20-0- o N 0 10 20 40 SR BELLE FIRMA 4245 North Central Expy Suite 501 Dallas, Texas 75205 214.865.7192 office L3.01