Loading...
HomeMy WebLinkAboutM202 Roof Plan HVAC[ O N) .1ROOF PLAN - HVAC TRUE 1 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City ofCarried �} �Nt1�i L rn ? �m r NM L J ~ NM ro N U y °Urn_ .U°1. a3i Q J u roof U 3 UCU a i J 7 cO mn Y C3 2 U PROVIDE PHENOLIC LABEL WITH UNIT NUMBER, UNIT SIZE, MODEL NUMBER, SERIAL NUMBER, AND DATE OF INSTALLATION ON ALL ROOFTOP UNITS. MECHANICAL PLAN NOTES 1 PROVIDE NEW ROOFTOP UNIT AND CURB. REUSE EXISTING TRUSS OPENING FOR DUCT DRCPAS FOSSIBLE. COORDINATE UNIT WITH STRUCTURE AM SHIM UNIT AND CURB LE FOR PROPER CONDENSATE DRAINAGE. PROVIDE FLEXIBLE CONNECTORS ON SUPPLYAI RETURN AIR DUCT CONNECTIONS. TRANSITION TO DUCT SIZES SHOWN ON SHEET M201, 2 PROVIDE EDGE MOUNTED EQUIPMENT RAILS AND INSTALL OWNER FURNISHED REMOTE CONDENSING UNIT FOR WALK-IN COOLER, WALK-IN FREEZER OR ICE MACHINE. INSTALL REFRIGERANT LINE SET, THERMOSTATIC EXPANSION VALVE, SOLENOID VALVE, TEMPERATURE CONTROL. SIGHT GIASS, FILTER DRIER, PRESSURE CONTROL. CRANKCASE HEATER, LOW AMBIENT CONTROLS, AND WEATHERPRWF HOUSING, AS APPLICABLE, PER MANUFACTURER'S INSTRUCTIONS. TRAP AND SLOPE REFRIGERANT LINES PER MANUFACTURER'S INSTRUCTIONS. PROVIDE PIPE CURB ASSEMBLY FOR EDGE PENETRATIONS. SEAL PIPING PENETRATIONS THROUGH COOLER1FREFMR ROOF AS REQUIRED. 3 INSTALL QWNER FURNISHED ROOF MOUNTED EXHAUST FAN AND CURB. REFER TO SCHEDULE ON SHEET M331 FORADDITIONAL INFORMATION. 4 PROVIDE ROOF MOUNTED EXHAUST FAN AND CURB. 5 INSTALL OWNER NRNISHED ROOF MOUNTED MAKE4JP MR UNIT AND CURB. PROVIDE FLEXIBLE CONNECTOR ON SUPPLY DUCT CONNECTION. MNNTNN ALL MANUFACTURER'S RECOMMENDED SERVICE CLEARANCES COORDINATE INSTALLATION WITH OTHER TRADES TO MNNTAIN MINIMUM 10'-0" CLEARANCE BETWEEN MY EXHAUST OR VENT TERMINATION AND MAKE-UP NR UNIT INTAKE. REFER TO SCHEDULE ON SHEET M301 FOR ADDTIONAL INFORMATION, 6 RELOCATE EXISTING GCCLER CONDENSING UNITS. EXTEND PIPING AMID RECONNECT TO EXISTING UNITS PROVIDE ROOF MOUNTED EQUIPMENT RAILS. CLEAN AND RBAUR UNITS AS REQUIRED. FIELD VERIFY EXACT CONDITIONS PRIOR TO BID, THIS SHEET IS PART OF THE CONSTRUCTION DOCUMENTS, OTHER SHEETS INCLUDING SPECIFICATIONS APPLY. THAT SHOWN HERON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWINGS; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENTAND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL Dialectic `JpaP(A,u/Na�g�aN: J� 00�'� A-E' P.yprb Na 1t180g9B1 ` "_ t e� STATE OF �C� ' 9 ••• Dialectic, 310 W 20th Street, Suite 200 F 816 997-9602 Kansas City, MO 64108 DialecticEng.com i a/"N jIIILRI`Ip 22113 Copyright 2018 Carmel (Zionsville), IN 10325 N. Michigan RD. Carmel, IN 46032 Owner: Cray's OPCO 1623 Toomy Road Austin, TX. 78704 Ph.(512)473-2783 Contact: Michael Hatcher Architect: Parkway CBA, LP 1000 Civic Circle Lewisville, TX. 75067 Ph: (469) 322-3714 Project Contact: Bill Pounds, ALA MEP Engineer: Dialecitc, Inc 210 W. 20th St. Suite 200 Kansas City, MO 64108 Ph: (816) 997-9627 Project Contact: Joe Hillebrenner, P.E. Structural Empires Armstrong -Douglas 6060 N. Central Expressway Suite 800 Dallas, TX 76206 Ph' (214) 237-7022 Contact: Scott Armstrong, P.E. Landscape Architect Belle Firma, Inc. 4246 North Central Expy. Suite 501 Dallas, Texas 75205 Ph: (214) 866-7192 Contact: Kon Haug, ASLA, CIARB FAVIk BY EKE CLK -- 04-97221 H 1:16161M�1100O:U,T. M202 DATE: V,5/LD/-1`J