Loading...
HomeMy WebLinkAboutP202 Plumbing Plan Water and GasPROVIDE TWO (2) 314ECW LINES WITH VISIBLE SHUT- OFFS AT 9'-W AFF FOR CARBONATORS. RELEASED FOR CONSTRUCTION (E) GAS METER l N l in will PLUMBING PLAN -WATER AND GAS ii V 1 114•=T-T TRUE LU rn j Nrn �m r U J ~ N� F J - prjN m w N 0 U � 3 or PLUMBING PLAN NOTES a of a U V U 1 PLUMBING FIXTURE/EQUIPMENT EXISTING TO REMAIN. THORWGHLYCLEPN, Z 0 ) O 2 REPAIR, AND ADJUST AS NEEDED FOR LIKE NEW CONDITION. Y > 0BUT 2 PROVIDE NEW PLUMBING MIXTURE EQUIPMENT AND ACCESSORIES IN SIMILAR 4 U > NOT NECESSARY �RERWTE, ITO PIPING = CORE ERIIL, AND CONNECT EXISTING AS REQUIRED C3n 3 CONNECTTO EXISTING DOMESTIC WATER LINE. FIELDVRFYEXACTLWATION H ug O. AND MAKE NECESSARYCONNECTIONS AS REQUIRED. U 7 4 CONNECTTO EXISTING GAS METER. COORDINATEWITILOCALGASCOMPANY TO VERIFY EXISTING METER CAPACITY IS ADEQUATE FCR ATOTAL CAPACITYAS INDICATED IN THE GASSCHEDULE. GAS PIPING SIZED FORA TOTAL DEVELOPED LENGTHOF1WAT7'WC. 5 ROUTE COLD WATER LINE DOWN TO FOOD SERVICE EQUIPMENT PROVIDE WATTS M-P BACKFLOW DEVICE PRIOR TO EQUIPMENT. 6 ROUT DWATERLINETOBEVERAGEDISPENSINGEQUIPMENT.PROVIDE WATTS #SD-3 BACKRTCW DEVICE PRIOR TO EQUIPMENT. 7 ROUTE FILTERED COLD WATER LINE DOWN TO FOOD SERVICE EQUIPMENT. PROVIDE WATTSM F7BPCKFLOW DEVICE PRIORTOTHE EQUIPMENT. GENERAL NOTES - WATER AND GAS A REFER TO SCHEDULES ON SHEET P402 FOR FIXTURE BRANCH CONNECTION SIZES. B PROVIDE ACCESS PANELS FOR SHUT-OFF VALVES LOCATED ABOVE HARD CEILINGS. C PROVIDE PRECISION PLUMBING PRODUCTS I'-500 TRAP PRIMER OR APPROVED EQUIVALENT FOR FLOOR GRANS LOCATED IN RESTROOMS AND THE KITCHEN SERVICE AISLE. D ROUTE GAS LINE TO GAS FRED CCORNG APPLIANCES PER-CCORNG APPLIANCE GAS" DETAIL. I FIRE PROTECTION NOTES I GENERAL: THIS SPACE IS CURRENTLY SERVED BY AN AUTOMATIC WET PIPE FIRE SPRINKLER SYSTEM. CONTRACTOR IS RESPONSIBLE FOR THE MODIFICATION OF THE EXISTING FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH RHEA REQUIREMENTS. PROVIDE ALL MATERIALS AND LABOR REWIRED FOR COMPLETE INSTALLATION. SYSTEM MODIFICATIONS SHALL BE DESIGNED UNDER THE SUPERVISION OF A LICENSED PROFESSIONAL ENGINEER, AND CONTRACTOR SHALL PREPARE ALL REQUIRED SIGNEDBEALED DRAWINGS, CALCULATIONS, AND SHALL OBTAIN APPROVAL Ot ALL STATE, LOCAL, AND INSURANCE UNDERWRITING AUTHORITIES. THE SPRINKLER SYSTEM SHALL BE TESTED UNDER PRESSURE BY CONTRACTOR, AND INSPECTED AND APPROVED BY LOCAL FIRE MARSHALL, PRIOR TO ACCEPTANCE BY OWNER, FIRE SPRINKLER CONTRACTOR SHALL ROUTE FIRE PROTECTION PIPING AS REQUIRED TO AVOID NE WIEXI SING PLUMBING, HVAQ AND ELECTRICAL. MAINTAIN ALL SPRINKLER PIPING AS HIGH AS POSSIBLE, ESPECIALLY IN WEN AREAS. R i PROVIDE COVERAGE OF ORDINARY HAZARD OCCUPANCY FOR THIS AREA, OPROVIDE SHIELDS, TRAYS, AND OTHER PROTECTION IN ACCORDANCE WITH NFPA REQUIREMENTS FOR THIS AREA. PROVIDE A FREEZE PROOF SPRINKLER SYSTEM IN THIS AREA. OPTIONS ARE AN AUXILIARY DRY PIPE SYSTE, DRY PIPE SPRINKLER HEADS, OR OTHER MEANS FOR A FREEZE PROOF SYSTEM ALLOWED BY NFPA 13, IF AN AUXILIARY SYSTEM IS PROVIDED, LOCATE THE DRY PIPE VALVE AND COMPRESSOR. COORDINATE LOCATION WITH OWNER AND POWER REQUIREMENTS WITH ELECTRICAL SUBLIXNTRACTOR ' 4\ PROVIDE HORIZONTAL SIDE WALL SPRINKLER HEAD IN ACCORDANCE WITH NFPA REQUIREMENTS FOR THIS AREA. PLUMBING REMODEL NOTE THIS DRAWING IS BASED ON THE BEST AVAILABLE INFORMATION AT THE TIME OF DF IGN AND MAYNOT RERECTASBUILT CONDITIONS. ALL PLUMBING INSTALLATIONS INDICATED ON THIS SHEET SHALL BE FIELD VERIFIED PRIOR TO BID AND DEMOLRION. PROVIDE ALL SAWCIIITING AND SACKFUL AS NECESSARY, REMOVE ALL EXISTING FIXTURES NOT TO REMAIN AND CAP ALL LINES BACK TO MAINS. SPECIFICATIONS APPLY. THAT SHOWN HERON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWINGS; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL Dialectic Carmel (Zionsville), IN 10325 N. Michigan RD. Carmel, IN 46032 Owner: Chuy's OPCO 1623 Toomy Road Ausbn,TX.78704 Ph: (512) 473-2783 Contact: Michael Hatcher Architect: Parkway CBA, LP 1000 Civic Circle Lewisville, TX. 75067 Ph: (469) 322-3714 Project Contact: Bill Pounds, AIR MEP Engineer: Dialecdc, Inc 210 W. 20th St. Suite 200 Kansas City, MO 64108 Ph: (816) 997-9627 Project Contact: Joe Hillebrenner, P.E. Structural Engineer Armstrong -Douglas 6060 N. Central Expressway Suite 800 Dallas, TX 76206 Ph' (214) 237-7022 Contact: Scott Armstrong, P.E. Landscape Architect Belle Firma, Inc. 4246 North Central Expy. Suite 501 Dallas, Texas 75205 Ph: (214) 866-7192 Contact: Kon Haug, ASIA, CLARB No. j Description Date MDB JMB 04-97221 PLUMBING PLAN - WATER AND GAS Subject to compliance with all regulations of State and Local Codes City ofCarmel ��}} ' V"IDwTc7H1pML DATE: V,5/LD/-1U Dialectic, Inc. T 816-997-9601 310 W 20th Street, Suite 200 F 816-997-9602 Kansas City, MO 64108 OialecticEng.com Na 10809901 STATE OF 9 P202