HomeMy WebLinkAboutCLAY CORNER 25 - CC025 (AS DESIGNED)IECC 2009 Performance Compliance
Property
1564 JENSEN DR
CARMEL, IN 46032
CCO25 (AS DESIGNED)
CLAY CORNER 25
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,178
$194
$375
$1,747
$564
$0
$2,311
Requirements
C4405.3
Performance -based compliance passes by 15.8%
402.4.1.2
Air Leakage Testing
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U-Factor
40322
Duct. Testing
C4
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
CTSI
Energy Solutions
As Designed
5948
5149
5375
$1,471
5564
SO
$2,036
Air sealing is 5.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 15.8%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
1/30119 at 9:19 AM
Ekotrope RATER - Version 3.1.0.2098
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
1564 JENSEN DR
CARMEL, IN 46032
LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 5 ACH50
Window U-Value: 0.33, SHGC: 0.28
Building Features
Duct Supply R-10.0, Return R-10.0
Duct Leakage to Outside 105.0 CFM @ 25Pa
Total Duct Leakage 168.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 1130/19 at 9:19 AM
Ekotrope RATER - Version 3.1.0.2098
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
1564 JENSEN DR
CARMEL, IN 46032
CCO25 (AS DESIGNED)
CLAY CORNER 25
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
2,123
19,107
6,172
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (2,123 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB 2X4 (1,746 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIGAR (180 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
None Present
Roof
El Name: SECOND (2,123 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property
1564 JENSEN DR
CARMEL, IN 46032
CCO25 (AS DESIGNED)
CLAY CORNER 25
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
El Name: FRONT (72 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH
El Name: BACK (90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH
El Name: LEFT SIDE (63 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST
El Name: LEFT SIDE GD (18 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST
11 Name: RIGHT SIDE (53 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE
El Air conditioner • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
C",
Energy Solutions
Air Leakage Control 2
Energy Code Inspection Checklist
Property
1564 JENSEN DR
CARMEL, IN 46032
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Results are projected
CCO25 (AS DESIGNED) Builder
CLAY CORNER 25 LENNAR HOMES
ElTest Status: Blower -door tested
House is air -sealed as to achieve 1,592 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 105.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 168.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM251100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 J 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 J 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
5N5
3
Building Summary
Property
Organization
1564 JENSEN DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
CCO25 [AS DESIGNED]
Builder
CLAY CORNER 25
LENNAR HOMES
General Building Information
Number Of Bedrooms
4
Number Of Floors
1
Conditioned Floor Area [sq. ft.]
2:123
Unconditioned, attached garage?
Yes
Conditioned Volume [cu. ft.]
19;167
Total Units in Building
1
Residence Type
Single family detached
Model
CHARTWELL (A)
Community
CLAY CORNER 25
Climate Zone
5A
Basement Wall
MEW
None Present
Basement Wall Library List
None Present
Inspection Status
Results are projected
C-M,
Energy Solutions
Slab Am
Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
SLAB R-10, 2'down
214 On Grade 0
0 2,123.0 sq. ft. Exposed Exterior
Conditioned
Space
Slab Library LisOEM"
0
Name Wall Construction Type
Slab Completer Llnderslab Insulation
Perimeterinsu}ation Perfineterinsu}ation R
R-value
Insulated . Width [ft]
Depth r] Value
IR-10, 2'down Woad Frame / Other
No 0
2 10
0.00
Framed Floor E
None Present
1
Building Summary
C-M
Energy Solutions
Property Organization
1564 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Inspection Status
CCO25 [AS DESIGNED] Builder Results are projected
CLAY CORNER 25 LENNAR HOMES
Framed Floor Library L'
Rim Joist
Rim Joist Library List
one
Library Type Surface Color Surface Area Location
CONDIAMB 2X4 G1 R-13 BATT, R-3.0
Medium
1.746.0 sq. P[.
Exposed Exterior
CONDIGAR G1 R-13 Gar Walls
Medium
180.0 sq. P[.
Unconditioned, attached garage
Wall Library List
Name
R-value
G1 R-13 BATT, R-3.0
15.12
G1 R-13 Gar Walls
11.141
Glazing
Name Library Type Wall Assignment
Basement Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
BACK 111-.33, SHGC-28 CONDIAMB 2X4
0
0
❑
North
90.0 sq. 1
FRONT 11-.33, SHGC-28 CONDIAMB 2X4
❑
0
❑
South
72.0 sq. R
LEFT SIDE 11-.33, SHGC-28 CONDIAMB 2X4
❑
0
❑
West
63.0 sq. R
OA
Building Summary
C-M
Energy Solutions
Property Organization
1564 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Inspection Status
CCO25 [AS DESIGNED] Builder Results are projected
CLAY CORNER 25 LENNAR HOMES
Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhand.Ft To Orientation Surface Area
Assignment Top Hottom
LEFT SIDE GD 11-.33, SHGG28 CONDIAMB 2X4 0 0 0 West 18.0 sq. ft.
RIGHT SIDE 11-.33, SHGG28 CONDIAMB 2X4 0 0 0 East 53.0 sq. ft.
Glazing Library List
Name
11-.33, SHGC-28
Skylight
Skylight Library List
Opaque Door
0.26
None Present
None Present
Name Library Type Wall Assignment Basement Wall
Assignment
FRONT Fiberglass Door CONDIAMB 2X4
GARAGE Fiberglass Door CONDIGAR
Opaque Door Library List
Name U-factor
Fiberglass Door 0.182
0.330
Emittance Solar Surface Color Surface Area Location
Absorptance
0.9 0.75 Medium 20.0 sq. ft Exposed Exterior
0.9 0.75 Medium 18.0 sq. fL Exposed Exterior
9
Building Summary
Property
1564 JENSEN DR
CARMEL, IN 46032
CCO25 [AS DESIGNED]
CLAY CORNER 25
Roof Insulation
Name Lib
SECOND R-3.9 Rlnwn C'R1
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
M
Surface Area Location
2,123 No Medium 2:123.0 sq. fL Attic
Roof Insulation Library List
Name Has Radiant Barrier
'•0 . -I .a l No
Whale House Infiltration
Infiltration Measurement Type
5 ACH at 50 Pa Blower -door tested
1111
Mechanical Ventilation
None Present
38268
4
Lighting
% Interior Fluorescent % Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting
Lighting Lighting Lighting
0 100 0 100 0 100
Gnsite Generation
None Present
4
Building Summary
Property
Organization
1564 JENSEN DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
CCO25 [AS DESIGNED]
Builder
CLAY CORNER 25
LENNAR HOMES
Onsite Generation Library
List
None Present
Solar Generation
Solar Generation Library List A
None
Conditioning Equipment
Inspection Status
Results are projected
C-M,
Energy Solutions
Name
Library Type
Heating Percent Load
Cooling Percent Lead
Hot Water Percent Laad
Air conditioner
CA13NA042
0%
1OD%
0%
Fuel -fired air
915SA48080917
100%
0%
0%
distribution
Water Heating
RE350"
0%
0%
100%
Equipment Type: 915SA48080S17
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95.5 AFUE
Heating Capacity [kBtulh]
78
Use default EAE
No
EAE [kWh]
946
rEquipmentnt Type: CA13NA042
Electric
ype Forced Air
PSG (Single Speed)
ency 13 SEER
city [kBtulh] 40
:j
Building Summary
Property
1564 JENSEN DR
CARMEL, IN 46032
CCO25 [AS DESIGNED]
CLAY CORNER 25
Equipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Distribution System
Distribution Type
Heating Equipment
Cooling Equipment
Sq. Feet Served
# Return Grilles
Supply Duct R Value
Return Duct R Value
Supply Duct Area [sq. ft.]
Return Duct Area [sq. ft_]
Duct Leakage to Outdoors (CFM25)
Total Leakage
Total Leakage Duct Test Conditions
Use Default Flow Rate
Duct 1
Duct Location
Percent Supply Area
Percent Return Area
Duct 2
Duct Location
Percent Supply Area
Percent Return Area
Duct 3
Duct Location
Percent Supply Area
Percent Return Area
Duct 4
Duct Location
Percent Supply Area
Percent Return Area
Duct 5
Duct Location
Percent Supply Area
Percent Return Area
Duct 6
Duct Location
Percent Supply Area
Percent Return Area
Ceiling Fan
Has Ceiling Fan
Cfm Per Watt
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
❑.98
Forced Air
Fuel-f red air distribution
Air conditioner
2123
5
10
10
1146.42
1061.5
105
168
Post -Construction
Yes
Conditioned Space
5
5
Attic (well vented; under insulation)
95
95
Conditioned Space
0
Conditioned Space
Conditioned Space
0
0
Conditioned Space
No
C-M,
Energy Solutions
A
Building Summary
Property
1564 JENSEN DR
CARMEL, IN 46032
CCO25 [AS DESIGNED]
CLAY CORNER 25
Water Distribution
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
N❑
Hot Water Pipe Length [ft]
50
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
30
Drain Water Heat Recovery?
No
Clothes Dryer
Fuel Type Electric
Cef 2.617
Field Utilization Timer Controls
Clothes Washer
Label Energy Rating
704 kWhlYear
Electric Rate
0.081kWh
Annual Gas Cost
$23.00
Gas Rate
$0.581Therm
Capacity
2.874
1 met
0.33053
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
5N5
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh/Year
C-M,
Energy Solutions
7