Loading...
HomeMy WebLinkAboutCLAY CORNER 25 - CC025 (AS DESIGNED)IECC 2009 Performance Compliance Property 1564 JENSEN DR CARMEL, IN 46032 CCO25 (AS DESIGNED) CLAY CORNER 25 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,178 $194 $375 $1,747 $564 $0 $2,311 Requirements C4405.3 Performance -based compliance passes by 15.8% 402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct. Testing C4 Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation CTSI Energy Solutions As Designed 5948 5149 5375 $1,471 5564 SO $2,036 Air sealing is 5.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 15.8%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 1/30119 at 9:19 AM Ekotrope RATER - Version 3.1.0.2098 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 1564 JENSEN DR CARMEL, IN 46032 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.33, SHGC: 0.28 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 105.0 CFM @ 25Pa Total Duct Leakage 168.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 1130/19 at 9:19 AM Ekotrope RATER - Version 3.1.0.2098 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 1564 JENSEN DR CARMEL, IN 46032 CCO25 (AS DESIGNED) CLAY CORNER 25 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 2,123 19,107 6,172 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (2,123 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall El Name: CONDIAMB 2X4 (1,746 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIGAR (180 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist None Present Roof El Name: SECOND (2,123 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property 1564 JENSEN DR CARMEL, IN 46032 CCO25 (AS DESIGNED) CLAY CORNER 25 Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected El Name: FRONT (72 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH El Name: BACK (90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH El Name: LEFT SIDE (63 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST El Name: LEFT SIDE GD (18 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST 11 Name: RIGHT SIDE (53 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE El Air conditioner • Electric • 100% Cooling Load @ 13 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor C", Energy Solutions Air Leakage Control 2 Energy Code Inspection Checklist Property 1564 JENSEN DR CARMEL, IN 46032 Organization TSI Energy Solutions Matthew Timmons Inspection Status Results are projected CCO25 (AS DESIGNED) Builder CLAY CORNER 25 LENNAR HOMES ElTest Status: Blower -door tested House is air -sealed as to achieve 1,592 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 105.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 168.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM251100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 J 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 J 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 5N5 3 Building Summary Property Organization 1564 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons CCO25 [AS DESIGNED] Builder CLAY CORNER 25 LENNAR HOMES General Building Information Number Of Bedrooms 4 Number Of Floors 1 Conditioned Floor Area [sq. ft.] 2:123 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 19;167 Total Units in Building 1 Residence Type Single family detached Model CHARTWELL (A) Community CLAY CORNER 25 Climate Zone 5A Basement Wall MEW None Present Basement Wall Library List None Present Inspection Status Results are projected C-M, Energy Solutions Slab Am Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area SLAB R-10, 2'down 214 On Grade 0 0 2,123.0 sq. ft. Exposed Exterior Conditioned Space Slab Library LisOEM" 0 Name Wall Construction Type Slab Completer Llnderslab Insulation Perimeterinsu}ation Perfineterinsu}ation R R-value Insulated . Width [ft] Depth r] Value IR-10, 2'down Woad Frame / Other No 0 2 10 0.00 Framed Floor E None Present 1 Building Summary C-M Energy Solutions Property Organization 1564 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CCO25 [AS DESIGNED] Builder Results are projected CLAY CORNER 25 LENNAR HOMES Framed Floor Library L' Rim Joist Rim Joist Library List one Library Type Surface Color Surface Area Location CONDIAMB 2X4 G1 R-13 BATT, R-3.0 Medium 1.746.0 sq. P[. Exposed Exterior CONDIGAR G1 R-13 Gar Walls Medium 180.0 sq. P[. Unconditioned, attached garage Wall Library List Name R-value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 Glazing Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK 111-.33, SHGC-28 CONDIAMB 2X4 0 0 ❑ North 90.0 sq. 1 FRONT 11-.33, SHGC-28 CONDIAMB 2X4 ❑ 0 ❑ South 72.0 sq. R LEFT SIDE 11-.33, SHGC-28 CONDIAMB 2X4 ❑ 0 ❑ West 63.0 sq. R OA Building Summary C-M Energy Solutions Property Organization 1564 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CCO25 [AS DESIGNED] Builder Results are projected CLAY CORNER 25 LENNAR HOMES Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhand.Ft To Orientation Surface Area Assignment Top Hottom LEFT SIDE GD 11-.33, SHGG28 CONDIAMB 2X4 0 0 0 West 18.0 sq. ft. RIGHT SIDE 11-.33, SHGG28 CONDIAMB 2X4 0 0 0 East 53.0 sq. ft. Glazing Library List Name 11-.33, SHGC-28 Skylight Skylight Library List Opaque Door 0.26 None Present None Present Name Library Type Wall Assignment Basement Wall Assignment FRONT Fiberglass Door CONDIAMB 2X4 GARAGE Fiberglass Door CONDIGAR Opaque Door Library List Name U-factor Fiberglass Door 0.182 0.330 Emittance Solar Surface Color Surface Area Location Absorptance 0.9 0.75 Medium 20.0 sq. ft Exposed Exterior 0.9 0.75 Medium 18.0 sq. fL Exposed Exterior 9 Building Summary Property 1564 JENSEN DR CARMEL, IN 46032 CCO25 [AS DESIGNED] CLAY CORNER 25 Roof Insulation Name Lib SECOND R-3.9 Rlnwn C'R1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions M Surface Area Location 2,123 No Medium 2:123.0 sq. fL Attic Roof Insulation Library List Name Has Radiant Barrier '•0 . -I .a l No Whale House Infiltration Infiltration Measurement Type 5 ACH at 50 Pa Blower -door tested 1111 Mechanical Ventilation None Present 38268 4 Lighting % Interior Fluorescent % Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting 0 100 0 100 0 100 Gnsite Generation None Present 4 Building Summary Property Organization 1564 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons CCO25 [AS DESIGNED] Builder CLAY CORNER 25 LENNAR HOMES Onsite Generation Library List None Present Solar Generation Solar Generation Library List A None Conditioning Equipment Inspection Status Results are projected C-M, Energy Solutions Name Library Type Heating Percent Load Cooling Percent Lead Hot Water Percent Laad Air conditioner CA13NA042 0% 1OD% 0% Fuel -fired air 915SA48080917 100% 0% 0% distribution Water Heating RE350" 0% 0% 100% Equipment Type: 915SA48080S17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 rEquipmentnt Type: CA13NA042 Electric ype Forced Air PSG (Single Speed) ency 13 SEER city [kBtulh] 40 :j Building Summary Property 1564 JENSEN DR CARMEL, IN 46032 CCO25 [AS DESIGNED] CLAY CORNER 25 Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Distribution System Distribution Type Heating Equipment Cooling Equipment Sq. Feet Served # Return Grilles Supply Duct R Value Return Duct R Value Supply Duct Area [sq. ft.] Return Duct Area [sq. ft_] Duct Leakage to Outdoors (CFM25) Total Leakage Total Leakage Duct Test Conditions Use Default Flow Rate Duct 1 Duct Location Percent Supply Area Percent Return Area Duct 2 Duct Location Percent Supply Area Percent Return Area Duct 3 Duct Location Percent Supply Area Percent Return Area Duct 4 Duct Location Percent Supply Area Percent Return Area Duct 5 Duct Location Percent Supply Area Percent Return Area Duct 6 Duct Location Percent Supply Area Percent Return Area Ceiling Fan Has Ceiling Fan Cfm Per Watt Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 ❑.98 Forced Air Fuel-f red air distribution Air conditioner 2123 5 10 10 1146.42 1061.5 105 168 Post -Construction Yes Conditioned Space 5 5 Attic (well vented; under insulation) 95 95 Conditioned Space 0 Conditioned Space Conditioned Space 0 0 Conditioned Space No C-M, Energy Solutions A Building Summary Property 1564 JENSEN DR CARMEL, IN 46032 CCO25 [AS DESIGNED] CLAY CORNER 25 Water Distribution Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Water Fixture Type Standard Use Default Hot Water Pipe Length N❑ Hot Water Pipe Length [ft] 50 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 30 Drain Water Heat Recovery? No Clothes Dryer Fuel Type Electric Cef 2.617 Field Utilization Timer Controls Clothes Washer Label Energy Rating 704 kWhlYear Electric Rate 0.081kWh Annual Gas Cost $23.00 Gas Rate $0.581Therm Capacity 2.874 1 met 0.33053 Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption 5N5 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year C-M, Energy Solutions 7