Loading...
HomeMy WebLinkAboutLEGACY RIDGE 139 - LR139 (AS DESIGNED)IECC 2009 Performance Compliance Property 14056 LARSON DR CARMEL, IN 46033 LR139 (AS DESIGNED) LEGACY RIDGE 139 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,905 $290 $411 $2,607 $959 $0 $3,565 Requirements C4405.3 Performance -based compliance passes by 0.8% 402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct. Testing C4 Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation CTSI Energy Solutions As Designed 51,906 5269 5411 $2,586 S959 SO $3,545 Air sealing is 6.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50Pa. Design exceeds requirements for IECC 2009 Performance compliance by 0.8%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 214119 at 11:38 AM Ekotrope RATER -Version 3.1.0.2101 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 14056 CARBON DR CARMEL, IN 46033 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 6 ACH50 Window U-Value: 0.32, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 328.0 CFM @ 25Pa Total Duct Leakage 437.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 2A 19 at 11:38 AM Ekotrope RATER - Version 3.1.0.2101 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 14056 LARSON DR CARMEL, IN 46033 LR139 (AS DESIGNED) LEGACY RIDGE 139 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 5,469 48,294 10,186 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT (1,951 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: AMBIENT (15 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 178, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 [ Name: CONDIGAR (Exterior Perimeter [ft]: 31, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (3,204 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (468 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 14056 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LR139 (AS DESIGNED) Builder LEGACY RIDGE 139 LENNAR HOMES Name: CONDIGAR (279 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIATTIC (255 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (314 s.f.) R: 13.575 El Name: CONDIGAR (31 s.f.) R: 10.876 Name: CONDIATTIC (31 s.f.) R: 13.575 Roof El Name: MAIN (1,966 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (138 s.f.), U: 0.320, SHGC: 0.28, Orientation: EAST El Name: BACK(210 s.f.), U: 0.320, SHGC: 0.31, Orientation: WEST C", Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization 14056 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status Results are projected LR139 (AS DESIGNED) Builder LEGACY RIDGE 139 LENNAR HOMES E] Name: BACK BSMT (11 s.f.), U: 0.320, SHGC: 0.31, Orientation: WEST E] Name: SLIDER (40 s.f.), U: 0.280, SHGC: 0.32, Orientation: WEST E] Name: RIGHT SIDE (82 s.f.), U: 0.320, SHGC: 0.31, Orientation: NORTH El Name: LEFT SIDE (121 s.f.), U: 0.320, SHGC: 0.31, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 92.1 AFUE Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 4,829 CFM50 (6.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC. in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 14056 LARSON DR CARMEL, IN 46033 LR139 (AS DESIGNED) LEGACY RIDGE 139 Duct Leakage Duct System 1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 328.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 437.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary C-M Energy Solutions Property Organization 14056 LARSON DR TSI Energy Solutions CARMEL- IN 46033 Matthew Timmons Inspection Status LR139 (AS DESIGNED) Builder Results are projected LEGACY RIDGE 139 LENNAR HOMES General Building Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 5,469 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 48;294 Total Units in Building 1 Residence Type Single family detached Model SOUTHILL (C) Community LEGACY RIDGE 139 Climate Zone 5A Basement Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, Oft 1 7 178 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, Oft 1 7 31 Exposed Exterior Conditioned Space Basement Wall Library List Name Feet From Wall Tap To Insulation Feet From Wall Top Tb Insulation Is Fully Insulated R-value Tap Bottom R-11 Draped, Oft 0 4 No 11.00 Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 1 Below Grade ❑ ❑ 1.951.0 sq. R. Exposed Exterior Conditioned Space Slab Library List Name Wall C Uninsulated Wood Frame / Other No ❑ 0 D 0.00 1 Building Summary Property Organization 14056 LARSON DR TSI Energy Solutions CARMEL- IN 46033 Matthew Timmons LR139 (AS DESIGNED) Builder LEGACY RIDGE 139 LENNAR HOMES ramed Floor Name Library Type Ca AMBIENT R-38, GR1 Framed Floor Library List Name Rvalue R-38, GR1 33.825 CTS,Eneergy Solutions Inspection Status Results are projected Floor Grade Surface Area Location 1.23 Above Grade 15.0 sq. ft Exposed Exterior Rim Joist Name Library Type Surface Area Location CONDIAMB G1 R-13, R-3.0 314.0 sq.ft. Exposed Exterior CONDIATTIC G1 R-13, R-3.0 31.0 sq. ft. Attic CONDIGAR G1 R-13, OSB 31.0 sq. ft. Unconditioned, attached garage Rim Joist Library List Name R value G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 li Name Library Type Surface Color Surface Area Location CONDIAMB G1 R-13 BATT, R-3.0 Medium 3.204.0 sq. fl. Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 468.0 sq. fl. Exposed Exterior CONDIATTIC G1 R-13 BATT, R-3.0 Medium 255.0 sq. fl. Attic 2 Building Summary C-M Energy Solutions Property Organization 14056 LARSON DR TSI Energy Solutions CARMEL- IN 46033 Matthew Timmons Inspection Status LR139 (AS DESIGNED) Builder Results are projected LEGACY RIDGE 139 LENNAR HOMES Name Library Type Surface Color Surface Area Location CONDIGAR G1 R-13 Gar Walls Medium 279.0 sq. fI. Unconditioned, attached garage Wall Library List Name R-value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, R-3.0 2X6 20217 Glazing Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft Te Overhang Ft Te Orientation Surface Area Assignment Top Bottom BACK 111-.32, SHGG.31 CONDIAMB ❑ ❑ ❑ West 210.0 sq. ft. BACK BSMT 11-.32, SHGG.31 CONDIAMB 0 0 ❑ West 11.0 sq. ft. FRONT 11-.32, SHGG28 CONDIAMB 0 0 ❑ East 138.0 sq. ft. LEFT SIDE 111-.32, 8HGG.31 CONDIAMB 0 0 0 South 121.0 sq. ft. RIGHT SIDE 111-.32, SHGG.31 CONDIAMB 0 0 0 North 82.0 sq. 1 SLIDER U-28, 3HGG.32 CONDIAMB 0 0 0 West 40.0 sq. 1 Glazing Library List Name Shgc U fiactnr U-28, SHGC-.32 0.32 0280 U-.32, SHGC-28 028 0.320 U-.32, SHGC-.31 0.31 0320 Building Summary Property 14056 LARSON DR CARMEL- IN 46033 LR139 (AS DESIGNED) LEGACY RIDGE 139 kylight Skylight Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Opaque Door Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta n ce FRONT Steel Door CONDIAMB 09 0.75 Medium 20.0 sq. ft Exposed Exterior GARAGE Steel Door CONDIGAR 09 0.75 Medium 18.0 sq. ft Exposed Exterior Opaque Door Library List Name Steel Door U -factor 0.182 Roof Insulation Name Library Type Attic Exterior Area Cray or Concrete Roof Surface Color Surface Area Location Vf.] Tiles MAIN R-38 Blown, GR1 °G No Medium 1.966.0 sq. fL Attic Roof Insulation Library List Name Has R-38 Blown, GR1 No 38263 4 Building Summary Property 14056 LARSON DR CARMEL- IN 46033 LR139 (AS DESIGNED) LEGACY RIDGE 139 hole House Infiltration Infiltration I6 ACH at 50 Pa 1 Mechanical Ventilation Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Blower -door tested 4 None Present C-M, Energy Solutions Lighting % Interior Fluorescent % Interior LED Lighting I Exterior Fluorescent % Exterior LED Lighting I Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting C 100 Gnsite Generation W IL None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present 0 100 0 100 A Building Summary Property Organization 14056 LARSON DR TSI Energy Solutions CARMEL- IN 46033 Matthew Timmons LR139 (AS DESIGNED) Builder LEGACY RIDGE 139 LENNAR HOMES Inspection Status Results are projected conditioning Equipment Name Library Type Heating Percent Load Air conditioner (2) CA13NA042 0% C-M, Energy Solutions g Percent LOW Hot water icc% I Fuel -fired air 912SA4808OS17 100% G°o distribution (1) IWater Heating (3) RE350" 0% D% 1 Equipment Type: 912SA4808OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 977 Equipment Type: CA13NA042 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Electric Forced Air PSG (Single Speed) 13 SEER 40 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 0% 0% 100% Building Summary Property Organization 14056 LARSON DR TSI Energy Solutions CARMEL- IN 46033 Matthew Timmons Inspection Status LR139 (AS DESIGNED) Builder Results are projected LEGACY RIDGE 139 LENNAR HOMES istributivn System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution [1) Cooling Equipment Air conditioner (2) Sq. Feet Served 5469 # Return Grilles 6 Supply Duct R Value 30 Return Duct R Value 30 Supply Duct Area [sq. ft.] 1107.5 Return Duct Area [sq. ft_] 1025.4 Duct Leakage to Outdoors (CFM25) 328 Total Leakage 437 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct t Duct Location Conditioned Space Percent Supply Area 70 Percent Return Area 70 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 30 Percent Return Area 30 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Ceiling Fan ' Has Ceiling Fan No Cfm Per Watt 101 Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 125 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 24 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 14056 LARSON DR CARMEL- IN 46033 LR139 (AS DESIGNED) LEGACY RIDGE 139 Fuel Type Cef Field Utilization lothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption "M Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Electric Timer Controls 704 kWh/Year 0.0nWh $23.00 $0.581Therm 2.847 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year C-M, Energy Solutions ,�