HomeMy WebLinkAboutLEGACY RIDGE 139 - LR139 (AS DESIGNED)IECC 2009 Performance Compliance
Property
14056 LARSON DR
CARMEL, IN 46033
LR139 (AS DESIGNED)
LEGACY RIDGE 139
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,905
$290
$411
$2,607
$959
$0
$3,565
Requirements
C4405.3
Performance -based compliance passes by 0.8%
402.4.1.2
Air Leakage Testing
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U-Factor
40322
Duct. Testing
C4
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
CTSI
Energy Solutions
As Designed
51,906
5269
5411
$2,586
S959
SO
$3,545
Air sealing is 6.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 0.8%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
214119 at 11:38 AM
Ekotrope RATER -Version 3.1.0.2101
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
14056 CARBON DR
CARMEL, IN 46033
LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls R-11
Framed Floor R-38
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 6 ACH50
Window U-Value: 0.32, SHGC: 0.31
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 328.0 CFM @ 25Pa
Total Duct Leakage 437.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 2A 19 at 11:38 AM
Ekotrope RATER - Version 3.1.0.2101
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
14056 LARSON DR
CARMEL, IN 46033
LR139 (AS DESIGNED)
LEGACY RIDGE 139
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
5,469
48,294
10,186
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT (1,951 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: AMBIENT (15 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
[ Name: CONDIAMB (Exterior Perimeter [ft]: 178, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
[ Name: CONDIGAR (Exterior Perimeter [ft]: 31, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CONDIAMB (3,204 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIAMB 2X6 (468 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property Organization
14056 LARSON DR TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
LR139 (AS DESIGNED) Builder
LEGACY RIDGE 139 LENNAR HOMES
Name: CONDIGAR (279 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (255 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Name: CONDIAMB (314 s.f.)
R: 13.575
El Name: CONDIGAR (31 s.f.)
R: 10.876
Name: CONDIATTIC (31 s.f.)
R: 13.575
Roof
El Name: MAIN (1,966 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
El Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
El Name: FRONT (138 s.f.), U: 0.320, SHGC: 0.28, Orientation: EAST
El Name: BACK(210 s.f.), U: 0.320, SHGC: 0.31, Orientation: WEST
C",
Energy Solutions
2
Energy Code Inspection Checklist
C-M
Energy Solutions
Property Organization
14056 LARSON DR TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons Inspection Status
Results are projected
LR139 (AS DESIGNED) Builder
LEGACY RIDGE 139 LENNAR HOMES
E] Name: BACK BSMT (11 s.f.), U: 0.320, SHGC: 0.31, Orientation: WEST
E] Name: SLIDER (40 s.f.), U: 0.280, SHGC: 0.32, Orientation: WEST
E] Name: RIGHT SIDE (82 s.f.), U: 0.320, SHGC: 0.31, Orientation: NORTH
El Name: LEFT SIDE (121 s.f.), U: 0.320, SHGC: 0.31, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 92.1 AFUE
Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 4,829 CFM50 (6.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC. in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
3
Energy Code Inspection Checklist
Property
14056 LARSON DR
CARMEL, IN 46033
LR139 (AS DESIGNED)
LEGACY RIDGE 139
Duct Leakage
Duct System 1
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 328.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 437.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
C-M
Energy Solutions
Property Organization
14056 LARSON DR TSI Energy Solutions
CARMEL- IN 46033 Matthew Timmons
Inspection Status
LR139 (AS DESIGNED) Builder Results are projected
LEGACY RIDGE 139 LENNAR HOMES
General Building Information
Number Of Bedrooms 4
Number Of Floors 2
Conditioned Floor Area [sq. ft.] 5,469
Unconditioned, attached garage? Yes
Conditioned Volume [cu. ft.] 48;294
Total Units in Building 1
Residence Type Single family detached
Model SOUTHILL (C)
Community LEGACY RIDGE 139
Climate Zone 5A
Basement Wall
Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing
CONDIAMB R-11 Draped, Oft 1 7 178 Exposed Exterior Conditioned Space
CONDIGAR R-11 Draped, Oft 1 7 31 Exposed Exterior Conditioned Space
Basement Wall Library List
Name Feet From Wall Tap To Insulation Feet From Wall Top Tb Insulation Is Fully Insulated R-value
Tap Bottom
R-11 Draped, Oft 0 4 No 11.00
Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated 1 Below Grade ❑ ❑ 1.951.0 sq. R. Exposed Exterior Conditioned
Space
Slab Library List
Name Wall C
Uninsulated Wood Frame / Other No ❑ 0 D 0.00
1
Building Summary
Property
Organization
14056 LARSON DR
TSI Energy Solutions
CARMEL- IN 46033
Matthew Timmons
LR139 (AS DESIGNED)
Builder
LEGACY RIDGE 139
LENNAR HOMES
ramed Floor
Name Library Type
Ca
AMBIENT R-38, GR1
Framed Floor Library List
Name
Rvalue
R-38, GR1
33.825
CTS,Eneergy Solutions
Inspection Status
Results are projected
Floor Grade Surface Area Location
1.23 Above Grade 15.0 sq. ft Exposed Exterior
Rim Joist
Name
Library Type
Surface Area
Location
CONDIAMB
G1 R-13, R-3.0
314.0 sq.ft.
Exposed Exterior
CONDIATTIC
G1 R-13, R-3.0
31.0 sq. ft.
Attic
CONDIGAR
G1 R-13, OSB
31.0 sq. ft.
Unconditioned, attached garage
Rim Joist Library List
Name
R value
G1 R-13, OSB
10.876
G1 R-13, R-3.0
13.575
li
Name
Library Type
Surface Color
Surface Area
Location
CONDIAMB
G1 R-13 BATT, R-3.0
Medium
3.204.0 sq. fl.
Exposed Exterior
CONDIAMB 2X6
G1 R-19, R-3.0 2X6
Medium
468.0 sq. fl.
Exposed Exterior
CONDIATTIC
G1 R-13 BATT, R-3.0
Medium
255.0 sq. fl.
Attic
2
Building Summary
C-M
Energy Solutions
Property Organization
14056 LARSON DR TSI Energy Solutions
CARMEL- IN 46033 Matthew Timmons
Inspection Status
LR139 (AS DESIGNED) Builder Results are projected
LEGACY RIDGE 139 LENNAR HOMES
Name Library Type Surface Color Surface Area Location
CONDIGAR G1 R-13 Gar Walls Medium 279.0 sq. fI. Unconditioned, attached garage
Wall Library List
Name R-value
G1 R-13 BATT, R-3.0 15.12
G1 R-13 Gar Walls 11.141
G1 R-19, R-3.0 2X6 20217
Glazing
Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft Te Overhang Ft Te Orientation Surface Area
Assignment Top Bottom
BACK 111-.32, SHGG.31 CONDIAMB ❑ ❑ ❑ West 210.0 sq. ft.
BACK BSMT 11-.32, SHGG.31 CONDIAMB 0 0 ❑ West 11.0 sq. ft.
FRONT 11-.32, SHGG28 CONDIAMB 0 0 ❑ East 138.0 sq. ft.
LEFT SIDE 111-.32, 8HGG.31 CONDIAMB 0 0 0 South 121.0 sq. ft.
RIGHT SIDE 111-.32, SHGG.31 CONDIAMB 0 0 0 North 82.0 sq. 1
SLIDER U-28, 3HGG.32 CONDIAMB 0 0 0 West 40.0 sq. 1
Glazing Library List
Name Shgc U fiactnr
U-28, SHGC-.32 0.32 0280
U-.32, SHGC-28 028 0.320
U-.32, SHGC-.31 0.31 0320
Building Summary
Property
14056 LARSON DR
CARMEL- IN 46033
LR139 (AS DESIGNED)
LEGACY RIDGE 139
kylight
Skylight Library List
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Opaque Door
Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location
Assignment Ab sorpta n ce
FRONT Steel Door CONDIAMB 09 0.75 Medium 20.0 sq. ft Exposed Exterior
GARAGE
Steel Door CONDIGAR 09 0.75 Medium 18.0 sq. ft Exposed Exterior
Opaque Door Library List
Name
Steel Door
U -factor
0.182
Roof Insulation
Name Library Type Attic Exterior Area Cray or Concrete Roof Surface Color Surface Area Location
Vf.] Tiles
MAIN R-38 Blown, GR1 °G No Medium 1.966.0 sq. fL Attic
Roof Insulation Library List
Name Has
R-38 Blown, GR1 No 38263
4
Building Summary
Property
14056 LARSON DR
CARMEL- IN 46033
LR139 (AS DESIGNED)
LEGACY RIDGE 139
hole House Infiltration
Infiltration
I6 ACH at 50 Pa
1
Mechanical Ventilation
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
Blower -door tested 4
None Present
C-M,
Energy Solutions
Lighting
% Interior Fluorescent % Interior LED Lighting I Exterior Fluorescent % Exterior LED Lighting I Garage Fluorescent % Garage LED Lighting
Lighting Lighting Lighting
C
100
Gnsite Generation W IL
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
0
100
0
100
A
Building Summary
Property
Organization
14056 LARSON DR
TSI Energy Solutions
CARMEL- IN 46033
Matthew Timmons
LR139 (AS DESIGNED)
Builder
LEGACY RIDGE 139
LENNAR HOMES
Inspection Status
Results are projected
conditioning Equipment
Name Library Type Heating Percent Load
Air conditioner (2) CA13NA042 0%
C-M,
Energy Solutions
g Percent LOW Hot water
icc%
I Fuel -fired air 912SA4808OS17 100% G°o
distribution (1)
IWater Heating (3) RE350" 0% D%
1
Equipment Type: 912SA4808OS17
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
92.1 AFUE
Heating Capacity [kBtulh]
78
Use default EAE
No
EAE [kWh]
977
Equipment Type: CA13NA042
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Equipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Electric
Forced Air
PSG (Single Speed)
13 SEER
40
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
0%
0%
100%
Building Summary
Property Organization
14056 LARSON DR TSI Energy Solutions
CARMEL- IN 46033 Matthew Timmons
Inspection Status
LR139 (AS DESIGNED) Builder Results are projected
LEGACY RIDGE 139 LENNAR HOMES
istributivn System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution [1)
Cooling Equipment
Air conditioner (2)
Sq. Feet Served
5469
# Return Grilles
6
Supply Duct R Value
30
Return Duct R Value
30
Supply Duct Area [sq. ft.]
1107.5
Return Duct Area [sq. ft_]
1025.4
Duct Leakage to Outdoors (CFM25)
328
Total Leakage
437
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct t
Duct Location
Conditioned Space
Percent Supply Area
70
Percent Return Area
70
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
30
Percent Return Area
30
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Ceiling Fan
'
Has Ceiling Fan
No
Cfm Per Watt
101
Water Distribution
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
125
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
24
Drain Water Heat Recovery?
No
C-M,
Energy Solutions
Building Summary
Property
14056 LARSON DR
CARMEL- IN 46033
LR139 (AS DESIGNED)
LEGACY RIDGE 139
Fuel Type
Cef
Field Utilization
lothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
"M
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
Electric
Timer Controls
704 kWh/Year
0.0nWh
$23.00
$0.581Therm
2.847
❑.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
C-M,
Energy Solutions
,�