HomeMy WebLinkAboutCLAY CORNER 37 - CC037 (AS DESIGNED)IECC 2009 Performance Compliance Property 1568 MAIRN AVE CARMEL, IN 46032 CC037 (AS DESIGNED) CLAY CORNER 37 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,330 $222 $392 $1,943 $673 $0 $2,617 Requirements C4405.3 Performance -based compliance passes by 5.4% 402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct. Testing C4 Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation CTSI Energy Solutions As Designed 51,254 5192 S392 $1,838 S573 SO $2,511 Air sealing is 6.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50Pa. Design exceeds requirements for IECC 2009 Performance compliance by 5.4%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 217119 at 8:39 AM Ekotrope RATER - Version 3.1.0.2105 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 1568 MAIRN AVE CARMEL, IN 46032 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-0.0 Under Infiltration 6 ACH50 Window U-Value: 0.31, SHGC: 0.32 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 180.0 CFM @ 25Pa Total Duct Leakage 240.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 217119 at 8:39 AM Ekotrope RATER - Version 3.1.0.2105 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 1568 MAIRN AVE CARMEL, IN 46032 CC037 (AS DESIGNED) CLAY CORNER 37 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 3,028 28,085 7,841 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (2,093 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall El Name: CONDIAMB 2X4 (2,312 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (440 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDIGAR (180 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIATTIC (463 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Energy Code Inspection Checklist Property 1568 MAI RN AVE CARMEL, IN 46032 CC037 (AS DESIGNED) CLAY CORNER 37 Name: CONDIAMB (49 s.f.) R: 13.575 Name: CONDIATTIC (82 s.f.) R: 13.575 Roof Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES El Name: SECOND (1,853 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Name: SLOPED (369 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 El Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (145 s.f.), U: 0.310, SHGC: 0.29, Orientation: SOUTH Name: FRONT GD (24 s.f.), U: 0.290, SHGC: 0.33, Orientation: SOUTH E] Name: BACK2X6 (90 s.f.), U: 0.310, SHGC: 0.32, Orientation: NORTH E] Name: LEFT SIDE (48 s.f.), U: 0.310, SHGC: 0.32, Orientation: WEST El Name: LEFT SIDE 2X6 (45 s.f.), U: 0.310, SHGC: 0.32, Orientation: WEST El Name: LEFT SIDE GD (18 s.f.), U: 0.290, SHGC: 0.33, Orientation: WEST C", Energy Solutions 2 Energy Code Inspection Checklist TSI Energy Solutions Property Organization 1568 MAIRN AVE TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status Results are projected CCO37 (AS DESIGNED) Builder CLAY CORNER 37 LENNAR HOMES E] Name: RIGHT SIDE (93 s.f.), U: 0.310, SHGC: 0.32, Orientation: EAST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE El Air conditioner • Electric • 100% Cooling Load @ 13 SEER Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 2,809 CFM50 (6.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 180.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 240.0 CFM @ 25Pa 3 Energy Code Inspection Checklist Property 1568 MAI RN AVE CARMEL, IN 46032 CCO37 (AS DESIGNED) CLAY CORNER 37 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property 1568 MAIRN AVE CARMEL, IN 46032 CC037 (AS DESIGNED) CLAY CORNER 37 General Building Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq. ft.] Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Model Community Climate Zone Basement Wall Basement Wall Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 4 2 3:028 Yes 28;085 1 Single family detached PENNINGTON (A) CLAY CORNER 37 5A None Present None Present Inspection Status Results are projected C-M, Energy Solutions Slab Am Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area SLAB R-10, 2'down 212 On Grade 0 0 2,093.0 sq. ft. Exposed Exterior Conditioned Space Slab Library LisOEM" 0 Name Wall Construction Type Slab Completer Llnderslab Insulation Perimeterinsu}ation Perfineterinsu}ation R R-value Insulated . Width [ft] Depth r] Value IR-10, 2'down Wood Frame / Other No 0 2 10 0.00 Framed Floor E None Present 1 Building Summary Property Organization 1568 MAIRN AVE TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons CC037 [AS DESIGNED] Builder CLAY CORNER 37 LENNAR HOMES Framed Floor Library List Rim Joist i Name CONDIAMB CONDIATTIC Rim Joist Library List Name G1 R-13. R-3.0 C-M, Energy Solutions Inspection Status Results are projected G1 R-13, R-3.0 49.0 sq.ft. Exposed Exteror G1 R-13, R-3.0 82.0 sq. ft. Attic ■ R-value 13.575 Name Library Type Surface Color Surface Area Location CONDIAMB 2X4 Exposed Exterior G1 R-13 BATT, R-3.0 Medium 2,312.0 sq. ft. CONDIAMB 2X6 Exposed Exterior G1 R-19, R-3.0 2X6 Medium 440.0 sq. ft. CONDIATTIC Attic G1 R-13 BATT, R-3.0 Medium 463.0 sq. ft. CONDIGAR Unconditioned, attached garage G1 R-13 Gar Walls Medium 180.0 sq. ft. Wall Library List Name R-value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, R-3.0 2X6 20217 2 Building Summary Energy Solutions C-M Property Organization 1568 MAIRN AVE TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CC037 [AS DESIGNED] Builder Results are projected CLAY CORNER 37 LENNAR HOMES Glazin Name Library Type Wall Assignment Basement Wall Overhang Assignment Depth Overhang Ft 7bp To Overhang Ft Ta Bottom Orientation Surface Area BACK 2X6 U-.31, SHGC-.32 CONDIAMB 2X6 ❑ ❑ ❑ North 90.0 sq. fL FRONT U-.31, SHGG29 CONDIAMB 2X4 0 0 0 South 145.0 sq. ft. FRONT GD U-29, SHGG.33 CONDIAMB 2X4 0 0 0 South 24.0 sq. 1 LEFT SIDE U-.31, SHGC-.32 CONDIAMB 2X4 0 0 ❑ West 48.0 sq. R LEFT SIDE 2X6 U-.31, SHGG.32 CONDIAMB 2X4 0 0 ❑ West 45.0 sq. ft LEFT SIDE GD U-29, SHGG.33 CONDIAMB 2X4 0 0 ❑ West 18.0 sq. fL RIGHT SIDE U-.31, SHGG.32 CONDIAMB 2X4 0 0 ❑ East 93.0 sq. fL Glazing Library List Name Shg c U factor U-29, SHGC-.33 0.33 0290 U-.31, SHGC-29 029 0.310 U-.31, SHGC-.32 0.32 0.310 Skylight Skylight Library List 3 Building Summary Property Organization 1568 MAIRN AVE TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons CC037 [AS DESIGNED] Builder CLAY CORNER 37 LENNAR HOMES Opaque Door Name FRONT Steel Door CONDIAMB 2X4 GARAGE Steel Door CONDIGAR Opaque Door Library List i Name LI -factor Steel Door 0.182 C-M, Energy Solutions Inspection Status Results are projected 0.9 0.75 Medium 20.0 sq. ft Exposed Exterior 0.9 0.75 Medium 18.0 sq. fL Exposed Exterior Roof Insulation Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area D.f.] Tiles Location SECOND R-38 Blown, GR1 1,B53 No Medium 1,853.0 sq. ft Attic SLOPED R-30 Vaulted, GR1 369 No Medium 369.0 sq. ft Attic Roof Insulation Library List Name Has Radiant Barrier R-value R-30 Vaulted. GR l No 27.186 R-38 Blown. GR1 No 38268 Whale House Infiltration Infiltration Measurement Type Shelter Glass 6 ACH at 50 Pa Blower -door tested 4 M Building Summary Property 1568 MAIRN AVE CARMEL, IN 46032 CC037 (AS DESIGNED) CLAY CORNER 37 Mechanical Ventilation Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Lighting o Interior Fluorescent % Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting ILighting Lighting Lighting 100 100 0 100 Onsite Generation None Present Gnsite Generation Library List None Present Solar Generation None Present Solar Generation Library List A None Present Conditioning Equipment Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load Air conditioner CA13NA042 0% 100% 0% Fuel4red air 9155A42060S17 100% ❑ % 0% distribution Water Heating RE350" 0% ❑ % 100% Building Summary Property Organization 1568 MAIRN AVE TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CC037 (AS DESIGNED) Builder Results are projected CLAY CORNER 37 LENNAR HOMES Equipment Type: 9155A42060SI Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 58 Use default EAE No EAE [kWh] 636 rributi nt Type: CA13NA042 ypeiencycity [kBtulh] quipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity {gal.] Hot Water Capacity [kBtulh] Recovery Efficiency Electric Forced Air PSG (Single Speed) 13 SEER 40 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 C-M, Energy Solutions Building Summary Property Organization 1568 MAIRN AVE TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CC037 (AS DESIGNED) Builder Results are projected CLAY CORNER 37 LENNAR HOMES Distribution System Distribution Type Forced Air Heating Equipment Fuel-f red air distribution Cooling Equipment Air conditioner Sq. Feet Served 3028 # Return Grilles 4 Supply Duct R Value 30 Return Duct R Value 20 Supply Duct Area [sq. ft.] 782.46 Return Duct Area [sq. ft_] 579.6 Duct Leakage to Outdoors (CFM25) 180 Total Leakage 240 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct t Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Ceiling Fan ' Has Ceiling Fan No Cfm Per Watt 101 Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 75 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 34 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 1568 MAIRN AVE CARMEL, IN 46032 CC037 [AS DESIGNED] CLAY CORNER 37 Fuel Type Cef Field Utilization lothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption "M Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Electric Timer Controls 704 kWh/Year 0.0nWh $23.00 $0.581Therm 2.874 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year C-M, Energy Solutions ,�