HomeMy WebLinkAboutCLAY CORNER 37 - CC037 (AS DESIGNED)IECC 2009 Performance Compliance
Property
1568 MAIRN AVE
CARMEL, IN 46032
CC037 (AS DESIGNED)
CLAY CORNER 37
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,330
$222
$392
$1,943
$673
$0
$2,617
Requirements
C4405.3
Performance -based compliance passes by 5.4%
402.4.1.2
Air Leakage Testing
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U-Factor
40322
Duct. Testing
C4
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
CTSI
Energy Solutions
As Designed
51,254
5192
S392
$1,838
S573
SO
$2,511
Air sealing is 6.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 5.4%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
217119 at 8:39 AM
Ekotrope RATER - Version 3.1.0.2105
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
1568 MAIRN AVE
CARMEL, IN 46032
LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 6 ACH50
Window U-Value: 0.31, SHGC: 0.32
Building Features
Duct Supply R-30.0, Return R-20.0
Duct Leakage to Outside 180.0 CFM @ 25Pa
Total Duct Leakage 240.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 217119 at 8:39 AM
Ekotrope RATER - Version 3.1.0.2105
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
1568 MAIRN AVE
CARMEL, IN 46032
CC037 (AS DESIGNED)
CLAY CORNER 37
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
3,028
28,085
7,841
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identity any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (2,093 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB 2X4 (2,312 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIAMB 2X6 (440 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDIGAR (180 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIATTIC (463 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Energy Code Inspection Checklist
Property
1568 MAI RN AVE
CARMEL, IN 46032
CC037 (AS DESIGNED)
CLAY CORNER 37
Name: CONDIAMB (49 s.f.)
R: 13.575
Name: CONDIATTIC (82 s.f.)
R: 13.575
Roof
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
El Name: SECOND (1,853 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Name: SLOPED (369 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
El Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
El Name: FRONT (145 s.f.), U: 0.310, SHGC: 0.29, Orientation: SOUTH
Name: FRONT GD (24 s.f.), U: 0.290, SHGC: 0.33, Orientation: SOUTH
E] Name: BACK2X6 (90 s.f.), U: 0.310, SHGC: 0.32, Orientation: NORTH
E] Name: LEFT SIDE (48 s.f.), U: 0.310, SHGC: 0.32, Orientation: WEST
El Name: LEFT SIDE 2X6 (45 s.f.), U: 0.310, SHGC: 0.32, Orientation: WEST
El Name: LEFT SIDE GD (18 s.f.), U: 0.290, SHGC: 0.33, Orientation: WEST
C",
Energy Solutions
2
Energy Code Inspection Checklist
TSI Energy Solutions
Property Organization
1568 MAIRN AVE TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons Inspection Status
Results are projected
CCO37 (AS DESIGNED) Builder
CLAY CORNER 37 LENNAR HOMES
E] Name: RIGHT SIDE (93 s.f.), U: 0.310, SHGC: 0.32, Orientation: EAST
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE
El Air conditioner • Electric • 100% Cooling Load @ 13 SEER
Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 2,809 CFM50 (6.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 180.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 240.0 CFM @ 25Pa
3
Energy Code Inspection Checklist
Property
1568 MAI RN AVE
CARMEL, IN 46032
CCO37 (AS DESIGNED)
CLAY CORNER 37
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
1568 MAIRN AVE
CARMEL, IN 46032
CC037 (AS DESIGNED)
CLAY CORNER 37
General Building Information
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq. ft.]
Unconditioned, attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Model
Community
Climate Zone
Basement Wall
Basement Wall Library List
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
4
2
3:028
Yes
28;085
1
Single family detached
PENNINGTON (A)
CLAY CORNER 37
5A
None Present
None Present
Inspection Status
Results are projected
C-M,
Energy Solutions
Slab Am
Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
SLAB R-10, 2'down
212 On Grade 0
0 2,093.0 sq. ft. Exposed Exterior
Conditioned
Space
Slab Library LisOEM"
0
Name Wall Construction Type
Slab Completer Llnderslab Insulation
Perimeterinsu}ation Perfineterinsu}ation R
R-value
Insulated . Width [ft]
Depth r] Value
IR-10, 2'down Wood Frame / Other
No 0
2 10
0.00
Framed Floor E
None Present
1
Building Summary
Property
Organization
1568 MAIRN AVE
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
CC037 [AS DESIGNED]
Builder
CLAY CORNER 37
LENNAR HOMES
Framed Floor Library List
Rim Joist
i
Name
CONDIAMB
CONDIATTIC
Rim Joist Library List
Name
G1 R-13. R-3.0
C-M,
Energy Solutions
Inspection Status
Results are projected
G1 R-13, R-3.0 49.0 sq.ft. Exposed Exteror
G1 R-13, R-3.0 82.0 sq. ft. Attic
■
R-value
13.575
Name
Library Type
Surface Color
Surface Area
Location
CONDIAMB 2X4
Exposed Exterior
G1 R-13 BATT, R-3.0
Medium
2,312.0 sq. ft.
CONDIAMB 2X6
Exposed Exterior
G1 R-19, R-3.0 2X6
Medium
440.0 sq. ft.
CONDIATTIC
Attic
G1 R-13 BATT, R-3.0
Medium
463.0 sq. ft.
CONDIGAR
Unconditioned, attached garage
G1 R-13 Gar Walls
Medium
180.0 sq. ft.
Wall Library List
Name
R-value
G1 R-13 BATT, R-3.0
15.12
G1 R-13 Gar Walls
11.141
G1 R-19, R-3.0 2X6
20217
2
Building Summary
Energy Solutions
C-M
Property
Organization
1568 MAIRN AVE
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Inspection Status
CC037 [AS DESIGNED]
Builder
Results
are projected
CLAY CORNER 37
LENNAR HOMES
Glazin
Name Library Type
Wall Assignment Basement Wall Overhang
Assignment
Depth
Overhang Ft
7bp
To Overhang Ft Ta
Bottom
Orientation
Surface Area
BACK 2X6 U-.31, SHGC-.32
CONDIAMB 2X6
❑
❑ ❑
North
90.0 sq. fL
FRONT U-.31, SHGG29
CONDIAMB 2X4
0
0 0
South
145.0 sq. ft.
FRONT GD U-29, SHGG.33
CONDIAMB 2X4
0
0 0
South
24.0 sq. 1
LEFT SIDE U-.31, SHGC-.32
CONDIAMB 2X4
0
0 ❑
West
48.0 sq. R
LEFT SIDE 2X6 U-.31, SHGG.32
CONDIAMB 2X4
0
0 ❑
West
45.0 sq. ft
LEFT SIDE GD U-29, SHGG.33
CONDIAMB 2X4
0
0 ❑
West
18.0 sq. fL
RIGHT SIDE U-.31, SHGG.32
CONDIAMB 2X4
0
0 ❑
East
93.0 sq. fL
Glazing Library List
Name
Shg c
U factor
U-29, SHGC-.33
0.33
0290
U-.31, SHGC-29
029
0.310
U-.31, SHGC-.32
0.32
0.310
Skylight
Skylight Library List
3
Building Summary
Property
Organization
1568 MAIRN AVE
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
CC037 [AS DESIGNED]
Builder
CLAY CORNER 37
LENNAR HOMES
Opaque Door
Name
FRONT Steel Door CONDIAMB 2X4
GARAGE Steel Door CONDIGAR
Opaque Door Library List
i
Name LI -factor
Steel Door 0.182
C-M,
Energy Solutions
Inspection Status
Results are projected
0.9 0.75 Medium 20.0 sq. ft Exposed Exterior
0.9 0.75 Medium 18.0 sq. fL Exposed Exterior
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area
D.f.] Tiles
Location
SECOND R-38 Blown, GR1 1,B53 No Medium 1,853.0 sq. ft Attic
SLOPED R-30 Vaulted, GR1 369 No Medium 369.0 sq. ft Attic
Roof Insulation Library List
Name Has Radiant Barrier
R-value
R-30 Vaulted. GR l No
27.186
R-38 Blown. GR1 No
38268
Whale House Infiltration
Infiltration Measurement Type
Shelter Glass
6 ACH at 50 Pa Blower -door tested
4
M
Building Summary
Property
1568 MAIRN AVE
CARMEL, IN 46032
CC037 (AS DESIGNED)
CLAY CORNER 37
Mechanical Ventilation
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Lighting
o Interior Fluorescent % Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting
ILighting Lighting Lighting
100 100 0 100
Onsite Generation
None Present
Gnsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List A
None Present
Conditioning Equipment
Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load
Air conditioner CA13NA042 0% 100% 0%
Fuel4red air 9155A42060S17 100% ❑ % 0%
distribution
Water Heating RE350" 0% ❑ % 100%
Building Summary
Property Organization
1568 MAIRN AVE TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Inspection Status
CC037 (AS DESIGNED)
Builder Results are projected
CLAY CORNER 37
LENNAR HOMES
Equipment Type: 9155A42060SI
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95.5 AFUE
Heating Capacity [kBtulh]
58
Use default EAE
No
EAE [kWh]
636
rributi
nt Type: CA13NA042
ypeiencycity [kBtulh]
quipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity {gal.]
Hot Water Capacity [kBtulh]
Recovery Efficiency
Electric
Forced Air
PSG (Single Speed)
13 SEER
40
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
C-M,
Energy Solutions
Building Summary
Property
Organization
1568 MAIRN AVE
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Inspection Status
CC037 (AS DESIGNED)
Builder Results are projected
CLAY CORNER 37
LENNAR HOMES
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel-f red air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
3028
# Return Grilles
4
Supply Duct R Value
30
Return Duct R Value
20
Supply Duct Area [sq. ft.]
782.46
Return Duct Area [sq. ft_]
579.6
Duct Leakage to Outdoors (CFM25)
180
Total Leakage
240
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct t
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
50
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Ceiling Fan
'
Has Ceiling Fan
No
Cfm Per Watt
101
Water Distribution
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
75
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
34
Drain Water Heat Recovery?
No
C-M,
Energy Solutions
Building Summary
Property
1568 MAIRN AVE
CARMEL, IN 46032
CC037 [AS DESIGNED]
CLAY CORNER 37
Fuel Type
Cef
Field Utilization
lothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
"M
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
Electric
Timer Controls
704 kWh/Year
0.0nWh
$23.00
$0.581Therm
2.874
❑.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
C-M,
Energy Solutions
,�