HomeMy WebLinkAboutCLAY CORNER 15 - CC015 (AS DESIGNED)IECC 2009 Performance Compliance Property 1504 JENSEN DR CARMEL, IN 46032 CCO15 (AS DESIGNED) CLAY CORNER 15 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,731 $271 $386 $2,388 $907 SO $3,295 Requirements C4405.3 Performance -based compliance passes by 32% 402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct. Testing C4 Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation CTSI Energy Solutions As Designed 51,691 5235 5386 $2,311 S907 SO $3,218 Air sealing is 5.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 3.2%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 217119 at 8:37 AM Ekotrope RATER - Version 3.1.0.2105 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 1504 JENSEN DR CARMEL, IN 46032 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor NIA Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.31, SHGC: 0.32 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 255.0 CFM @ 25Pa Total Duct Leakage 408.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 217119 at 8:37 AM Ekotrope RATER - Version 3.1.0.2105 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 1504 JENSEN DR CARMEL, IN 46032 CC015 (AS DESIGNED) CLAY CORNER 15 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 5,121 46,922 9,961 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT (2,093 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall ] Name: CONDIAMB (Exterior Perimeter [ft]: 192, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 ] Name: CONDIGAR (Exterior Perimeter [ft]: 20, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Alcove Grade Wall El Name: COND/AMB 2X4 (2,312 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (440 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I ]l Name: CONDIGAR (180 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 1504 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons CC015 (AS DESIGNED) Builder CLAY CORNER 15 LENNAR HOMES Name: CONDIATTIC (463 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist El Name: CONDIAMB (241 s.f.) R: 13.575 Name: CONDIGAR (20 s.f.) R: 10.876 El Name: CONDIATTIC (82 s.f.) R: 13.575 Roof Name: SECOND (1,853 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I El Name: SLOPED (369 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (145 s.f.), U: 0.310, SHGC: 0.29, Orientation: SOUTH El Name: FRONT GD (24 s.f.), U: 0.290, SHGC: 0.33, Orientation: SOUTH C", Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization 1504 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status Results are projected CCO15 (AS DESIGNED) Builder CLAY CORNER 15 LENNAR HOMES E] Name: BACK 2X6 (90 s.f.), U: 0.310, SHGC: 0.32, Orientation: NORTH E] Name: LEFT SIDE (48 s.f.), U: 0.310, SHGC: 0.32, Orientation: WEST El Name: LEFT SIDE 2X6 (45 s.f.), U: 0.310, SHGC: 0.32, Orientation: WEST El Name: LEFT SIDE GD (18 s.f.), U: 0.290, SHGC: 0.33, Orientation: WEST El Name: RIGHT SIDE (93 s.f.), U: 0.310, SHGC: 0.32, Orientation: EAST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment M Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE El Air conditioner • Electric • 100% Cooling Load @ 13 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 3,910 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 1504 JENSEN DR CARMEL, IN 46032 CCO15 (AS DESIGNED) CLAY CORNER 15 Duct Leakage Duct System 1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 255.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 408.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary 7'SI Energy Solutions Property Organization 1504 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CC015 [AS DESIGNED] Builder Results are projected CLAY CORNER 15 LENNAR HOMES General Building Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 5:121 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 46;922 Total Units in Building 1 Residence Type Single family detached Model PENNINGTON (A) Community CLAY CORNER 15 Climate Zone 5A Basement Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, Oft 1 8 192 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, Oft 1 8 20 Exposed Exterior Conditioned Space Basement Wall Library List Name Feet From Wall Tap To Insulation Feet From Wall Top Tb Insulation Is Fully Insulated R-value Top Bottom R-11 Draped, Oft 0 4 No 11.00 Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 212 Below Grade ❑ 0 2,093.0 sq. R. Exposed Exterior Conditioned Space Slab Library List Name Wall C Uninsulated Wood Frame / Other No ❑ 0 D 0.00 1 Building Summary Property Organization 1504 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons CC015 [AS DESIGNED] Builder CLAY CORNER 15 LENNAR HOMES Framed Floor Framed Floor Library List Rim Joist Name CONDIAMB CONDIATTIC C O N DIGAR Rim Joist Library List Name G1 R-13, OSB G1 R-13, R-3.0 Library 7yp( G1 R-13, R-3.0 Inspection Status Results are projected urface Area 241.0 sq.ft. 7'SI Energy Solutions Locatior Exposed Exterior G1 R-13, R-3.0 82.0 sq. ft. Attic G1 R-13, OSB 20.0 sq. ft. Exposed Exterior 2-Value 10.876 13.575 Name Library Type Surface Color Surface Area Location CONDIAMB 2X4 G1 R-13 BATT, R-3.0 Medium 2,312.0 sq. ft. Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 440.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-13 BATT, R-3.0 Medium 463.0 sq. ft. Attic CONDIGAR G1 R-13 Gar Walls Medium 180.0 sq. ft. Unconditioned, attached garage 2 Building Summary Property 1504 JENSEN DR CARMEL, IN 46032 CC015 [AS DESIGNED] CLAY CORNER 15 brary List AA Name G1 R-13 BATT, R-3.0 G1 R-13 Gar Walls G1 R-19, R-3.0 2X6 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 20217 Inspection Status Results are projected C-M, Energy Solutions Glazing Name Library type Wall Assignment Basement Wall Overhang Depth Assignment Overhang Ft To Top Overhang Ft To Bottom Orientation Surface Area BACK 2X6 11-.31, SHGG.32 CONDIAMB 2X6 0 0 0 North 90.0 sq. R FRONT 11-.31, SHGG29 CONDIAMB 2X4 0 0 0 South 145.0 sq. ft. FRONT GD 11-29, SHGG.33 CONDIAMB 2X4 0 0 0 South 24.0 sq. R LEFT SIDE U-.31, SHGG.32 CONDIAMB 2X4 0 0 0 West 48.0 sq. R LEFT SIDE 2X6 U-.31, SHGG.32 CONDIAMB 2X4 0 0 0 West 45.0 sq. R LEFT SIDE GD U-29, SHGG.33 CONDIAMB 2X4 0 0 0 West 18.0 sq. R RIGHT SIDE 11-.31, SHGG.32 CONDIAMB 2X4 0 0 0 East 93.0 sq. R Glazing Library List Name U-29, SHGC-.33 U-.31, SHGC-29 U-.31, SHGC-.32 Skylight 0.33 0290 0.29 0.310 D.32 0.310 None Present 9 Building Summary Property 1504 JENSEN DR CARMEL, IN 46032 CC015 [AS DESIGNED] CLAY CORNER 15 Skylight Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Opaque Door Name Library Type Wall Assignmen, FRONT Steel Door CONDIAMB 2X4 GARAGE Steel Door CONDIGAR Opaque Door Library List Name Roof Insulation Assign ment U -factor 0.182 C-M, Energy Solutions Inspection Status Results are projected r su dace Area Location Absorptance 0.9 0.75 Medium 20.0 sq. ft Exposed Exterior 0.9 0.75 Medium 18.0 sq. ft Exposed Exterior Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location Vt.] Tiles SECOND R-38 Blown, GR1 1,853 No Medium 1,853.0 sq. Tt Attic SLOPED R-30 Vaulted. GR1 369 No Medium 369.0 sa. tL Attic Roof Insulation Library List Name Has Radiant Barrier R-value R-30 Vaulted, GR1 No 27.186 R-38 Blown, GR1 No 38268 M Building Summary Property 1504 JENSEN DR CARMEL, IN 46032 CC015 [AS DESIGNED] CLAY CORNER 15 Whole House Infiltration Infiltration I5 ACH at 50 Pa 1 Mechanical Ventilation Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Blower -door tested 4 None Present C-M, Energy Solutions Lighting % Interior Fluorescent % Interior LED Lighting I Exterior Fluorescent % Exterior LED Lighting I Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting C 100 0 100 0 100 Gnsite Generation W IL None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present A Building Summary Property Organization 1504 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CC015 [AS DESIGNED] Builder Results are projected CLAY CORNER 15 LENNAR HOMES Conditioning Equipment Name Library Type Heating Percent Load C Air conditioner CA13NA042 0% I Fuel -fired air 915SA42060S17 100% distribution IWater Heating RE350" 0% Equipment Type: 915SA4206OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 58 Use default EAE No EAE [kWh] 636 Equipment Type: CA13NA042 Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 Equipment Type: RE350* M Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 C-M, Energy Solutions g Percent LOW Hot water icc% 0% °0 100% Building Summary Property Organization 1504 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CC015 [AS DESIGNED] Builder Results are projected CLAY CORNER 15 LENNAR HOMES Distribution System Distribution Type Forced Air Heating Equipment Fuel-f red air distribution Cooling Equipment Air conditioner Sq. Feet Served 5121 # Return Grilles 4 Supply Duct R Value 30 Return Duct R Value 20 Supply Duct Area [sq. ft.] 1382.67 Return Duct Area [sq. ft_] 1024.2 Duct Leakage to Outdoors (CFM25) 2.55 Total Leakage 408 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Ceiling Fan ' Has Ceiling Fan No Cfm Per Watt 101 Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 75 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 34 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 1504 JENSEN DR CARMEL, IN 46032 CC015 [AS DESIGNED] CLAY CORNER 15 Fuel Type Cef Field Utilization lothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption "M Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Electric Timer Controls 704 kWh/Year 0.0nWh $23.00 $0.581Therm 2.874 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year C-M, Energy Solutions ,�