Loading...
HomeMy WebLinkAboutLEGACY RIDGE 146 - LR146 (AS DESIGNED)IECC 2009 Performance Compliance Property 14093 LARSON DR CARMEL, IN 46033 LR146 (AS DESIGNED) LEGACY RIDGE 146 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,658 $255 $41 0 $2,324 $922 S0 $3,246 Requirements C4405.3 Performance -based compliance passes by 3.5% 402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct. Testing C4 Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation CTSI Energy Solutions As Designed 51,591 5242 5410 $2,243 5922 S0 $3,165 Air sealing is 6.OD ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 3.5%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 214119 at 11:47 AM Ekotrope RATER -Version 3.1.0.2101 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 14093 CARBON DR CARMEL, IN 46033 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor NIA Slab R-0.0 Perimeter, R-0.0 Under Infiltration 6 ACH50 Window U-Value: 0.32, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 308.0 CFM @ 25Pa Total Duct Leakage 411.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 2A 19 at 11:47 AM Ekotrope RATER - Version 3.1.0.2101 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 14093 LARSON DR CARMEL, IN 46033 LR146 (AS DESIGNED) LEGACY RIDGE 146 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 5,144 45,306 8,815 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT (1,812 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall ] Name: CONDIAMB (Exterior Perimeter [ft]: 161, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 ]l Name: CONDIGAR (Exterior Perimeter [ft]: 32, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Alcove Grade Wall El Name: COND/AMB (2,274 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (468 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I ]l Name: CONDIGAR (288 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property organization 14093 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LR146 (AS DESIGNED) Builder LEGACY RIDGE 146 LENNAR HOMES Name: CONDIATTIC (256 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist El Name: CONDIAMB (296 s.f.) R: 13.575 Name: CONDIGAR (32 s.f.) R: 10.876 El Name: CONDIATTIC (32 s.f.) R: 13.575 Roof Name: MAIN (1,813 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected Name: FRONT (123 s.f.), U: 0.320, SHGC: 0.28, Orientation: EAST El Name: BACK(210 s.f.), U: 0.320, SHGC: 0.31, Orientation: WEST El Name: BACK BSMT (11 s.f.), U: 0.320, SHGC: 0.31, Orientation: WEST El Name: SLIDER (40 s.f.), U: 0.280, SHGC: 0.32, Orientation: WEST C", Energy Solutions 2 Energy Code Inspection Checklist TSI Energy Solutions Property Organization 14093 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status Results are projected LR146 (AS DESIGNED) Builder LEGACY RIDGE 146 LENNAR HOMES E] Name: RIGHT SIDE (50 s.f.), U: 0.320, SHGC: 0.31, Orientation: NORTH E] Name: LEFT SIDE (94 s.f.), U: 0.320, SHGC: 0.31, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 4,531 CFM50 (6.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC. Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 308.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 411.0 CFM @ 25Pa 3 Energy Code Inspection Checklist Property 14093 LARSON DR CARMEL, IN 46033 LR146 (AS DESIGNED) LEGACY RIDGE 146 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary C-M Energy Solutions Property Organization 14093 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status LR146 (AS DESIGNED) Builder Results are projected LEGACY RIDGE 146 LENNAR HOMES General Building Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 5:144 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 45;366 Total Units in Building 1 Residence Type Single family detached Model SOUTHILL (A) Community LEGACY RIDGE 146 Climate Zone 5A Basement Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, Oft 1 7 161 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, Oft 1 7 32 Exposed Exterior Conditioned Space Basement Wall Library List Name Feet From Wall Tap To Insulation Feet From Wall Top Tb Insulation Is Fully Insulated R-value Tap Bottom R-11 Draped, Oft 0 4 No 11.00 Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 1 Below Grade ❑ ❑ 1.812.0 sq. R. Exposed Exterior Conditioned Space Slab Library List Name Wall C Uninsulated Wood Frame / Other No ❑ 0 D 0.00 1 Building Summary Property Organization 14093 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LR146 (AS DESIGNED) Builder LEGACY RIDGE 146 LENNAR HOMES Framed Floor Framed Floor Library List Rim Joist Name CONDIAMB CONDIATTIC C O N DIGAR Rim Joist Library List Name G1 R-13, OSB G1 R-13, R-3.0 Library 7yp( G1 R-13, R-3.0 Inspection Status Results are projected urface Area 296.0 sq. ft. 7'SI Energy Solutions Locatior Exposed Exterior G1 R-13, R-3.0 32.0 sq. ft. Attic G1 R-13, OSB 2-Value 10.876 13.575 32.0 sq. ft. Unconditioned, attached garage Name Library Type Surface Color Surface Area Location CONDIAMB G1 R-13 BATT, R-3.0 Medium 2.274.0 sq. ft. Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 468.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-13 BATT, R-3.0 Medium 256.0 sq. ft. Attic CONDIGAR G1 R-13 Gar Walls Medium 288.0 sq. ft. Unconditioned, attached garage 2 Building Summary Property 14093 LARSON DR CARMEL, IN 46033 LR146 (AS DESIGNED) LEGACY RIDGE 146 brary List AA Name G1 R-13 BATT, R-3.0 G1 R-13 Gar Walls G1 R-19, R-3.0 2X6 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 20217 Inspection Status Results are projected C-M, Energy Solutions Glazing Name Library type Wall Assignment Basement Wall Overhang Depth Assignment Overhang Ft To Top Overhang Ft To Bottom Orientation Surface Area BACK 11-.32, SHGG.31 CONDIAMB 0 0 0 West 210.0 sq. ft. BACK BSMT 11-.32, SHGG.31 CONDIAMB 0 0 0 West 11.0 sq. ft. FRONT 11-.32, SHGG28 CONDIAMB 0 0 0 East 123.0 sq. ft. LEFT SIDE U-.32, SHGG.31 CONDIAMB 0 0 0 South 94.0 sq. tt RIGHT SIDE U-.32, SHGG.31 CONDIAMB 0 0 0 North 50.0 sq. 1 SLIDER U-28, SHGG.32 CONDIAMB 0 0 0 West 40.0 sq. R Glazing Library Li Name U-28, SHGC-.32 U-.32, SHGC-28 U-.32, SHGC-.31 Skylight 0.32 0280 028 0.320 0.31 0.320 9 Building Summary Property 14093 LARSON DR CARMEL, IN 46033 LR146 (AS DESIGNED) LEGACY RIDGE 146 Skylight Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Opaque Door Name Library Type Wall Assignmen, FRONT Steel Door CONDIAMB GARAGE Steel Door CONDIGAR Opaque Door Library List Name Assign ment U -factor 0.182 C-M, Energy Solutions Inspection Status Results are projected r su dace Area Location Absorptance 0.9 0.75 Medium 20.0 sq. ft Exposed Exterior 0.9 0.75 Medium 18.0 sq. ft Exposed Exterior Roof Insulation MUIEW I = Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location P.f.] Tiles MAIN R-79 FLI— r,P 1 7 R1 13 M, Madw— i .97R n — ft ❑ttir Roof Insulation Library List A��hl Name Has Radiant Barrier R-value '•0 :aI l No 38268 Whole House Infiltration Infiltration 6 ACH at 50 Pa Blower -door tested 4 M Building Summary Property 14093 LARSON DR CARMEL, IN 46033 LR146 (AS DESIGNED) LEGACY RIDGE 146 Mechanical Ventilation Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Lighting o Interior Fluorescent % Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting ILighting Lighting Lighting 100 100 0 100 Onsite Generation None Present Gnsite Generation Library List None Present Solar Generation None Present Solar Generation Library List A None Present Conditioning Equipment Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load Air conditioner (2) CA13NA042 0% 100% 0% Fuel -fired air 9155A4808OS17 100% ❑ % 0% distribution (1) Water Heating (3) RE350" 0% ❑ % 100% Building Summary Property Organization 14093 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status LR146 (AS DESIGNED) Builder Results are projected LEGACY RIDGE 146 LENNAR HOMES Equipment Type: 9155A4808OSi Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 rributi nt Type: CA13NA042 ypeiencycity [kBtulh] quipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity {gal.] Hot Water Capacity [kBtulh] Recovery Efficiency Electric Forced Air PSG (Single Speed) 13 SEER 40 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 C-M, Energy Solutions Building Summary Property Organization 14093 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status LR146 (AS DESIGNED) Builder Results are projected LEGACY RIDGE 146 LENNAR HOMES Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution [1) Cooling Equipment Air conditioner (2) Sq. Feet Served 5144 # Return Grilles 6 Supply Duct R Value 30 Return Duct R Value 30 Supply Duct Area [sq. ft.] 1041.7 Return Duct Area [sq. ft_] 964.5 Duct Leakage to Outdoors (CFM25) 308 Total Leakage 411 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 70 Percent Return Area 70 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 30 Percent Return Area 30 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Ceiling Fan ' Has Ceiling Fan No Cfm Per Watt 101 Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 121 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 20 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 14093 LARSON DR CARMEL, IN 46033 LR146 (AS DESIGNED) LEGACY RIDGE 146 Fuel Type Cef Field Utilization lothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption "M Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Electric Timer Controls 704 kWh/Year 0.0nWh $23.00 $0.581Therm 2.847 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year C-M, Energy Solutions ,�