HomeMy WebLinkAboutLEGACY PRAIRIE 1402 - LP1402 (AS DESIGNED)IECC 2009 Performance Compliance
Property
7244 ZANESVILLE RD
CARM EL, IN 46033
LP1402 (AS DESIGNED)
LEGACY PRAIRIE 1402
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$844
$109
$350
$1,303
$583
$0
$1,886
Requirements
C-M,
Energy Solutions
As Designed
$610
$128
$350
$1,089
$583
$0
$1,672
405.3 Performance -based compliance passes by 16 5%
402.4.1.2 Air Leakage Testing Air sealing is 5.01) ACH at 50 Pa. It must not exceed 7.013 ACH at 50 Pa
402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration U-Factor
C4 403.2.2 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R405.2 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 16.5%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
2127119 at 2:23 PM
Ekotrope RATER - Version 3.1.0.2118
IECC 2Q1)9 Performance compliance results calculated using Ekotrope's energy algorithm, which is a RESINET Accredited HERS Rating Tool.
7244 ZANESVILLE RD
CARMEL, IN 46033
LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor R-38
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 5 ACH50
Window U-Value: 0.32, SHGC: 0.34
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 118.0 CFM @ 25Pa
Total Duct Leakage 189.0 CFM @ 25Pa
Heating Furnace - Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
2127/19 at 2:23 PM
Ekotrope RATER - Version 3.1.0.2118
No version of this software has been reviewed or approved by ICC or its affiliates_
The 20N International Energy Conservation Code is a registered trademark oft he International Code Council, Inc. ('ICC').
This software is a RESNETAccredited HERS Rating Tool.
Energy Cade Inspection Checklist
Property
7244 ZANESVILLE RD
CARM EL, IN 46033
LP1402 (AS DESIGNED)
LEGACY PRAIRIE 1402
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
2,364
19,776
5,382
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
j Name: SLAB 1 (536 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Name: SLAB 2 (66 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: OVER GARAGE (411 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
None Present
Above Grade Wall
Name: CON DIAM B (950 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIAMB 2X6 (85 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CON DIGAR (364 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Energy Cade Inspection Checklist
Property Organization
7244 ZANESVILLE RD TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
LP1402 (AS DESIGNED) Builder
LEGACY PRAIRIE 1402 LENNAR HOMES
El Name: CONDlGAR 2X6 (112 s.f.)
R-0 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDICOND (1,664 s.f.)
R-0 continuous insulation, R-22 cavity insulation
Insulation Grade: I
Rim Joist
El Name: CONDIAMB (71 s.f.)
R: 13.575
1� Name: CON DIGAR (59 s.f.)
1--1 R:10.876
Name: CON DICOND (118 s.f.)
R: 10.876
Roof
1� Name: MAIN (946 s.f.)
1--1 R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
1� Name: FRONT (20 s.f.)
1--1 U:0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
j] Name: FRONT (99 s.f.), U: 0.320, SHGC: 0.34, Orientation: EAST
E] Name: BACK (114 s.f.), U: 0.320, SHGC: 0.34, Orientation: WEST
C-M,
Energy Solutions
2
Energy Cade Inspection Checklist
C-M
Energy Solutions
Property Organization
7244 ZANESVILLE RD TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons Inspection Status
Results are projected
LP1402 (AS DESIGNED) Builder
LEGACY PRAIRIE 1402 LENNAR HOMES
E] Name: SLIDER (33 s.f.), U: 0.320, SHGC: 0.34, Orientation: WEST
E] Name: GD (20 s.f.), U: 0.320, SHGC: 0.34, Orientation: WEST
Skyl ig ht
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
El Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE
E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
[] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
Test Status: Blower -door tested
House is air -sealed as to achieve 1,648 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 118.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 189.0 CFM @ 25Pa 3
Energy Cade Inspection Checklist
Property
7244 ZANESVILLE RD
CARM EL, IN 46033
LP1402 (AS DESIGNED)
LEGACY PRAIRIE 1402
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage e= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage -�= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C-M,
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property)
Organization
7244 7ANESVILLE RD
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Inspection Status
LP1402 (AS DESIGNED)
Builder Results are projected
LEGACY PRAIRIE 1402
LENNAR HOMES
General Building Information
Number Of Bedrooms
3
Number Of Floors
3
Conditioned Floor Area [sq. ft.]
2,364
Unconditioned; attached garage?
Yes
Conditioned Volume [cu. ft.]
19,776
Total Units in Building
1
Residence Type
Townhouse; inside unit
Model
Community
LEGACY PRAIRIE 1402
Climate Zone
5A
Basement Wall
'
None Present
Basement Wall Library List
None Present
SIa
C-M,
Energy Solutions
Name Library type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
SLAB 1 R-10, 2'down 53 On Grade '.23 0 536.0 sq. ft. Exposed Exterior Conditioned
Space
SLAB 2 R-10, 2'down 35 On Grade '.23 0 66.0 sq. ft. Exposed Exterior Conditioned
Space
Slab Library List
Name Wall Construction type Slab Ccmpletely Underslab Insulation Perimeter Insulation Perimeter Insulation R R-value
Insulated. Width [tj Depth [ftj Value
R-10. 2'down Wood Frame / Other No 0
2 10 0.00
1
Building Summary
Property)
Organization
7244 7ANESVILLE RD
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
LP1402 (AS D ESI GNED)
Builder
LEGACY PRAIRIE 1402
LENNAR HOMES
Framed Floor
Name Library type
Car
OVER GARAGE R-38, GR1
Framed Floor Library List
Name
R-value
R-38, GR1
33.625
Rim Joist
Name
CONDIAMB
CONDICOND
CON DI GAR
Rim Joist Library List
Name
G1 R-13, OSB
G1 R-13, R-3.0
Inspection Status
Results are projected
1.23 Above Grade
C-M,
Energy Solutions
411.0 sq. ft. Unconditioned, attached
garage
uorary type surrace Area Locaiwr
G1 R-13, R-3.0 71.0 sq. R. Exposed Exterior
G1 R-13, OSB
G1 R-13, OSB
Name Library Type
CONDIAMB G1 R-13 BATT, R3A
CONDIAMB 2X6 G1 R-19, R3.0 2x6
CONDICOND G1 R-22Dbl Wall
;t•vame
10.676
13.575
Surface Colo
Medium
Medium
Medium
118.0 sq. ft. Conditioned Space (Adiabatic)
59.0 sq. ft. Unconditioned, attached garage
Surface Area Location
950.0 sq. ft. Exposed Exterior
85.0 sq. ft. Exposed Exterior
1,664.0 sq. ft. Conditioned Space (Adiabatic)
2
Building Summary
Property
Organization
Energy Solutions
C-M
7244 7ANESVILLE RD
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Inspection Status
LP1402 (AS DESIGNED)
Builder
Results are projected
LEGACY PRAIRIE 1402
LENNAR HOMES
Name
Library type
Surface Color
Surface Area Location
CONDIGAR G1 R-13 Gar Wall&
Medium
364.0 sq. ft. Unconditioned. attached garage
CONDIGAR 2X6 G1 R-1 % 2x6 GAR
Medium
112.0 sq. ft. Unconditioned, attached garage
■
Wall Library List
Name
R-value
G1 R-13 BATT, R-3.0
15.12
G1 R-13 Gar Walls
11.141
G1 R-19, 2x6 GAR
16.218
G1 R-19, R-3.0 2X6
20.217
G1 R-22 Dbl Wall
18.407
Glazing
Name Library 'TV pe
Wall Assignment Basement Wall Overhang
Assignment
Depth
Overhang Ft To Overhang
Top
Ft To
Isottom
Orientation
Surface Area
BACK U-.32, SHGC-.34
CONDIAMB
0
0
0
West
114.0 sq. ft.
FRONT U-.32, SHGC-.34
CONDIAMB
0
0
0
East
99.0 sq. ft.
GD U-.32, SHGC-.34
CON DIAMB 2X6
0
0
0
West
20.0 sq. ft.
SLIDER U-.32, SHGC-.34
CONDIAMB
❑
0
0
West
33-ID sq. ft.
Glazing Library List
Name
Shgc
U-factor
U-.32, SHGG.34
0.34
0.320
Skylight
None Present
3
Building Summary
Property
7244 7ANESVILLE RB
CARMEL, IN 46033
LP1402 (AS D ESI GNED)
LEGACY PRAIRIE 1402
Skylight Library List
Organization
TSI Energy Solutions
Ma tthew Ti m mon s
Builder
LENNAR HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Opaque Door
Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location
Assignment Ab so rp to n ce
FRONT Steel Door CONDIAMB 2X6 0.9 0.75 Medium 20.Q sq. ft. Exposed Exterior
GARAGE
Steel Door CONDIGAR 2X6 0.9 0.75 Medium 18.Q sq. ft. Exposed Exterior
Opaque Door Library List
Name U-factor
Steel Door 0.182
Roof Insulation
Name Library lype Attic Exterior Area Clay or Concrete Roof
P.f.] Tiles
IMAIN R-38 Blown, GR1 946 No
Roof Insulation Library List
Name Has Radiant Barrier
R-38 Blown, GR1 No
Whole House Infiltration
Infiltration Measurement Type
5 ACH at 50 Pa Blower -door tested
Surface Color Surface Area
R-value
38268
4
Medium 946.0 sq. ft.
Location
Attic
4
Building Summary
Property
7244 7ANESVILLE RD
CARMEL, IN 46033
LP1402 (AS D ESI GNED)
LEGACY PRAIRIE 1402
Mechanical Ventilation
Lighting
°I Interior Fluorescent
Lighting
100
Organization
TSI Energy Solutions
Ma tthew Ti m mon s
Builder
LENNAR HOMES
Gnsite Generation
None Present
Gnsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
9
Inspection Status
Results are projected
100
C-M,
Energy Solutions
0
100
,:I
Building Summary
Property)
Organization
7244 7ANESVILLE RD
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
LP1402 (AS D ESI GNED)
Builder
LEGACY PRAIRIE 1402
LENNAR HOMES
o�tioning Equipment
Name
Library type H
Air conditioner (2)
CA13MA036
Fuel -fired air
915SA48080S17
distribution (1)
Water Heating (3)
RE350"
Equipment Type: 915SA4808OS17
ME=
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95.5 AFUE
Heating Capacity [kBtulh]
78
Use default EAE
No
EAE [kWh]
946
Equipment Type: CA13NAO36 a
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 34.2
Equipment Type: RE350*
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
Inspection Status
Results are projected
100%
0%
C-M,
Energy Solutions
0%
100%
A
Building Summary
Property)
Organization
7244 7ANESVILLE RD
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
LP1402 (AS D ESI GNED)
Builder
LEGACY PRAIRIE 1402
LENNAR HOMES
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution (1)
Cooling Equipment
Air conditioner (2)
Sq. Feet Served
2364
# Return Grilles
2
Supply Duct R Value
30
Return Duct R Value
30
Supply Duct Area [sq. ft.]
478.7
Return Duct Area [sq. ft]
177.3
Duct Leakage to Outdoors (CFM25)
118
Total Leakage
189
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
50
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Water Distribution
__.]& V"
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
86
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
30
Drain Water Heat Recovery?
No
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
7244 7ANESVILLE RD
CARMEL, IN 46033
LP1402 (AS D ESI GNED)
LEGACY PRAIRIE 1402
r
lothes Dryer
elType
f
ld Utilization
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization
TSI Energy Solutions
Ma tthew Ti m coon s
Builder
LENNAR HOMES
Electric
2.32
Timer Controls
irw
704 kWh/Year
$0. d8lkWh
$23.00
$0.58frherm
2.874
❑.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
Inspection Status
Results are projected
W
C-M,
Energy Solutions