Loading...
HomeMy WebLinkAboutLEGACY PRAIRIE 1402 - LP1402 (AS DESIGNED)IECC 2009 Performance Compliance Property 7244 ZANESVILLE RD CARM EL, IN 46033 LP1402 (AS DESIGNED) LEGACY PRAIRIE 1402 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $844 $109 $350 $1,303 $583 $0 $1,886 Requirements C-M, Energy Solutions As Designed $610 $128 $350 $1,089 $583 $0 $1,672 405.3 Performance -based compliance passes by 16 5% 402.4.1.2 Air Leakage Testing Air sealing is 5.01) ACH at 50 Pa. It must not exceed 7.013 ACH at 50 Pa 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor C4 403.2.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R405.2 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 16.5%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 2127119 at 2:23 PM Ekotrope RATER - Version 3.1.0.2118 IECC 2Q1)9 Performance compliance results calculated using Ekotrope's energy algorithm, which is a RESINET Accredited HERS Rating Tool. 7244 ZANESVILLE RD CARMEL, IN 46033 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls NIA Framed Floor R-38 Slab R-10.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.32, SHGC: 0.34 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 118.0 CFM @ 25Pa Total Duct Leakage 189.0 CFM @ 25Pa Heating Furnace - Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 2127/19 at 2:23 PM Ekotrope RATER - Version 3.1.0.2118 No version of this software has been reviewed or approved by ICC or its affiliates_ The 20N International Energy Conservation Code is a registered trademark oft he International Code Council, Inc. ('ICC'). This software is a RESNETAccredited HERS Rating Tool. Energy Cade Inspection Checklist Property 7244 ZANESVILLE RD CARM EL, IN 46033 LP1402 (AS DESIGNED) LEGACY PRAIRIE 1402 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 2,364 19,776 5,382 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab j Name: SLAB 1 (536 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Name: SLAB 2 (66 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: OVER GARAGE (411 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall None Present Above Grade Wall Name: CON DIAM B (950 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIAMB 2X6 (85 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CON DIGAR (364 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Energy Cade Inspection Checklist Property Organization 7244 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LP1402 (AS DESIGNED) Builder LEGACY PRAIRIE 1402 LENNAR HOMES El Name: CONDlGAR 2X6 (112 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDICOND (1,664 s.f.) R-0 continuous insulation, R-22 cavity insulation Insulation Grade: I Rim Joist El Name: CONDIAMB (71 s.f.) R: 13.575 1� Name: CON DIGAR (59 s.f.) 1--1 R:10.876 Name: CON DICOND (118 s.f.) R: 10.876 Roof 1� Name: MAIN (946 s.f.) 1--1 R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door 1� Name: FRONT (20 s.f.) 1--1 U:0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected j] Name: FRONT (99 s.f.), U: 0.320, SHGC: 0.34, Orientation: EAST E] Name: BACK (114 s.f.), U: 0.320, SHGC: 0.34, Orientation: WEST C-M, Energy Solutions 2 Energy Cade Inspection Checklist C-M Energy Solutions Property Organization 7244 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status Results are projected LP1402 (AS DESIGNED) Builder LEGACY PRAIRIE 1402 LENNAR HOMES E] Name: SLIDER (33 s.f.), U: 0.320, SHGC: 0.34, Orientation: WEST E] Name: GD (20 s.f.), U: 0.320, SHGC: 0.34, Orientation: WEST Skyl ig ht None Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER [] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 1,648 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 118.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 189.0 CFM @ 25Pa 3 Energy Cade Inspection Checklist Property 7244 ZANESVILLE RD CARM EL, IN 46033 LP1402 (AS DESIGNED) LEGACY PRAIRIE 1402 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage e= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage -�= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C-M, Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property) Organization 7244 7ANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status LP1402 (AS DESIGNED) Builder Results are projected LEGACY PRAIRIE 1402 LENNAR HOMES General Building Information Number Of Bedrooms 3 Number Of Floors 3 Conditioned Floor Area [sq. ft.] 2,364 Unconditioned; attached garage? Yes Conditioned Volume [cu. ft.] 19,776 Total Units in Building 1 Residence Type Townhouse; inside unit Model Community LEGACY PRAIRIE 1402 Climate Zone 5A Basement Wall ' None Present Basement Wall Library List None Present SIa C-M, Energy Solutions Name Library type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area SLAB 1 R-10, 2'down 53 On Grade '.23 0 536.0 sq. ft. Exposed Exterior Conditioned Space SLAB 2 R-10, 2'down 35 On Grade '.23 0 66.0 sq. ft. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction type Slab Ccmpletely Underslab Insulation Perimeter Insulation Perimeter Insulation R R-value Insulated. Width [tj Depth [ftj Value R-10. 2'down Wood Frame / Other No 0 2 10 0.00 1 Building Summary Property) Organization 7244 7ANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LP1402 (AS D ESI GNED) Builder LEGACY PRAIRIE 1402 LENNAR HOMES Framed Floor Name Library type Car OVER GARAGE R-38, GR1 Framed Floor Library List Name R-value R-38, GR1 33.625 Rim Joist Name CONDIAMB CONDICOND CON DI GAR Rim Joist Library List Name G1 R-13, OSB G1 R-13, R-3.0 Inspection Status Results are projected 1.23 Above Grade C-M, Energy Solutions 411.0 sq. ft. Unconditioned, attached garage uorary type surrace Area Locaiwr G1 R-13, R-3.0 71.0 sq. R. Exposed Exterior G1 R-13, OSB G1 R-13, OSB Name Library Type CONDIAMB G1 R-13 BATT, R3A CONDIAMB 2X6 G1 R-19, R3.0 2x6 CONDICOND G1 R-22Dbl Wall ;t•vame 10.676 13.575 Surface Colo Medium Medium Medium 118.0 sq. ft. Conditioned Space (Adiabatic) 59.0 sq. ft. Unconditioned, attached garage Surface Area Location 950.0 sq. ft. Exposed Exterior 85.0 sq. ft. Exposed Exterior 1,664.0 sq. ft. Conditioned Space (Adiabatic) 2 Building Summary Property Organization Energy Solutions C-M 7244 7ANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status LP1402 (AS DESIGNED) Builder Results are projected LEGACY PRAIRIE 1402 LENNAR HOMES Name Library type Surface Color Surface Area Location CONDIGAR G1 R-13 Gar Wall& Medium 364.0 sq. ft. Unconditioned. attached garage CONDIGAR 2X6 G1 R-1 % 2x6 GAR Medium 112.0 sq. ft. Unconditioned, attached garage ■ Wall Library List Name R-value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, 2x6 GAR 16.218 G1 R-19, R-3.0 2X6 20.217 G1 R-22 Dbl Wall 18.407 Glazing Name Library 'TV pe Wall Assignment Basement Wall Overhang Assignment Depth Overhang Ft To Overhang Top Ft To Isottom Orientation Surface Area BACK U-.32, SHGC-.34 CONDIAMB 0 0 0 West 114.0 sq. ft. FRONT U-.32, SHGC-.34 CONDIAMB 0 0 0 East 99.0 sq. ft. GD U-.32, SHGC-.34 CON DIAMB 2X6 0 0 0 West 20.0 sq. ft. SLIDER U-.32, SHGC-.34 CONDIAMB ❑ 0 0 West 33-ID sq. ft. Glazing Library List Name Shgc U-factor U-.32, SHGG.34 0.34 0.320 Skylight None Present 3 Building Summary Property 7244 7ANESVILLE RB CARMEL, IN 46033 LP1402 (AS D ESI GNED) LEGACY PRAIRIE 1402 Skylight Library List Organization TSI Energy Solutions Ma tthew Ti m mon s Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Opaque Door Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab so rp to n ce FRONT Steel Door CONDIAMB 2X6 0.9 0.75 Medium 20.Q sq. ft. Exposed Exterior GARAGE Steel Door CONDIGAR 2X6 0.9 0.75 Medium 18.Q sq. ft. Exposed Exterior Opaque Door Library List Name U-factor Steel Door 0.182 Roof Insulation Name Library lype Attic Exterior Area Clay or Concrete Roof P.f.] Tiles IMAIN R-38 Blown, GR1 946 No Roof Insulation Library List Name Has Radiant Barrier R-38 Blown, GR1 No Whole House Infiltration Infiltration Measurement Type 5 ACH at 50 Pa Blower -door tested Surface Color Surface Area R-value 38268 4 Medium 946.0 sq. ft. Location Attic 4 Building Summary Property 7244 7ANESVILLE RD CARMEL, IN 46033 LP1402 (AS D ESI GNED) LEGACY PRAIRIE 1402 Mechanical Ventilation Lighting °I Interior Fluorescent Lighting 100 Organization TSI Energy Solutions Ma tthew Ti m mon s Builder LENNAR HOMES Gnsite Generation None Present Gnsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present 9 Inspection Status Results are projected 100 C-M, Energy Solutions 0 100 ,:I Building Summary Property) Organization 7244 7ANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LP1402 (AS D ESI GNED) Builder LEGACY PRAIRIE 1402 LENNAR HOMES o�tioning Equipment Name Library type H Air conditioner (2) CA13MA036 Fuel -fired air 915SA48080S17 distribution (1) Water Heating (3) RE350" Equipment Type: 915SA4808OS17 ME= Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 Equipment Type: CA13NAO36 a Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 34.2 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 Inspection Status Results are projected 100% 0% C-M, Energy Solutions 0% 100% A Building Summary Property) Organization 7244 7ANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LP1402 (AS D ESI GNED) Builder LEGACY PRAIRIE 1402 LENNAR HOMES Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution (1) Cooling Equipment Air conditioner (2) Sq. Feet Served 2364 # Return Grilles 2 Supply Duct R Value 30 Return Duct R Value 30 Supply Duct Area [sq. ft.] 478.7 Return Duct Area [sq. ft] 177.3 Duct Leakage to Outdoors (CFM25) 118 Total Leakage 189 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Water Distribution __.]& V" Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 86 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 30 Drain Water Heat Recovery? No Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 7244 7ANESVILLE RD CARMEL, IN 46033 LP1402 (AS D ESI GNED) LEGACY PRAIRIE 1402 r lothes Dryer elType f ld Utilization Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization TSI Energy Solutions Ma tthew Ti m coon s Builder LENNAR HOMES Electric 2.32 Timer Controls irw 704 kWh/Year $0. d8lkWh $23.00 $0.58frherm 2.874 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year Inspection Status Results are projected W C-M, Energy Solutions