Loading...
HomeMy WebLinkAboutCLAY CORNER 5 - CC005 (AS DESIGNED)IECC 2009 Performance Compliance Property 1565 LASH ST CARMEL, IN 46032 CCO05 (AS DESIGNED) CLAY CORNER 5 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,383 $200 $372 $1,955 $801 so $2,756 Requirements C4405.3 Performance -based compliance passes by 3.7% 402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct. Testing C4 Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation CTSI Energy Solutions As Designed $1,327 $184 $372 $1,883 $801 $0 $2,684 Air sealing is 5.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 3.7%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 2f 8119 at 11: 23 AM Ekotrope RATER - Version 3.1.0.2106 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 1565 LASH ST CARMEL, IN 46032 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor NIA Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.33, SHGC: 0.28 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 252.0 CFM @ 25Pa Total Duct Leakage 336.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 218119 at 11:23 AM Ekotrope RATER - Version 3.1.0.2106 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 1565 LASH ST CARMEL, IN 46032 CC005 (AS DESIGNED) CLAY CORNER 5 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 4,246 38,214 8,312 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT (2,123 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall ] Name: CONDIAMB (Exterior Perimeter [ft]: 194, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 ]l Name: CONDIGAR (Exterior Perimeter [ft]: 20, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Alcove Grade Wall El Name: COND/AMB 2X4 (1,746 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIGAR (180 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Energy Code Inspection Checklist Property Organization 1565 LASH ST TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons CCO05 (AS DESIGNED) Builder CLAY CORNER 5 LENNAR HOMES El Name: RIM CONDIAMB (194 s.f.) R: 13.575 Name: CONDIGAR (20 s.f.) R: 10.876 Roof El Name: SECOND (2,123 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (72 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH 11 Name: BACK (90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH 11 Name: LEFT SIDE (63 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST El Name: LEFT SIDE GD (18 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST E] Name: BSMT (32 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST E] Name: RIGHT SIDE (53 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST E] Name: BSMT (16 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST Skylight None Present C-M, Energy Solutions 2 Energy Code Inspection Checklist Property 1565 LASH ST CARMEL, IN 46032 CCO05 (AS DESIGNED) CLAY CORNER 5 Mechanical Ventilation None Present Mechanical Equipment Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE El Air conditioner • Electric • 100% Cooling Load @ 13 SEER El Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 3,185 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 252.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 336.0 CFM @ 25Pa C", Energy Solutions 3 Energy Code Inspection Checklist Property 1565 LASH ST CARMEL, IN 46032 CCO05 (AS DESIGNED) CLAY CORNER 5 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary C-M Energy Solutions Property Organization 1565 LASH ST TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CCO05 [AS DESIGNED] Builder Results are projected CLAY CORNER 5 LENNAR HOMES General Building Information Number Of Bedrooms 4 Number Of Floors 1 Conditioned Floor Area [sq. ft.] 4:246 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 38;214 Total Units in Building 1 Residence Type Single family detached Model CHARTWELL (A) Community CLAY CORNER 5 Climate Zone 5A Basement Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, Oft 1 8 194 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, Oft 1 8 20 Exposed Exterior Conditioned Space Basement Wall Library List Name Feet From Wall Tap To Insulation Feet From Wall Top Tb Insulation Is Fully Insulated R-value Tap Bottom R-11 Draped, Oft 0 4 No 11.00 Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 214 Below Grade ❑ ❑ 2.123.0 sq. R. Exposed Exterior Conditioned Space Slab Library List Name Wall C Uninsulated Wood Frame / Other No ❑ 0 D 0.00 1 Building Summary Property Organization 1565 LASH ST TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons CC005 [AS DESIGNED] Builder CLAY CORNER 5 LENNAR HOMES Framed Floor Framed Floor Library List Rim Joist i Name CON DIGAR RIM CONDIAMB Rim Joist Library List Name G1 R-13, OSB G1 R-13, R-3.0 CONDIAMB 2X4 CON DIGAR .saAi G1 R-13, OSB G1 R-13, R-3.0 R-value 10.876 13.575 G1 R-13 BATT, R-3-0 Inspection Status Results are projected 20.0 sq.ft. 194.0 sq. ft. Medium 1,746.0 sq. ft. G1 R-13 Gar Walls Medium 7'SI Energy Solutions Exposed Exterior Exposed Exterior Exposed Exterior 180.0 sq. ft. Unconditioned, attached garage 2 Building Summary C-M Energy Solutions Property Organization 1565 LASH ST TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CCO05 [AS DESIGNED] Builder Results are projected CLAY CORNER 5 LENNAR HOMES brary List Name R-value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 Glazing Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft Te Overhang Ft Te Orientation Surface Area Assignment Top Bottom BACK 11-.33, SHGG28 CONDIAMB 2X4 ❑ 0 ❑ North 90.0 sq. R BSMT 11-.33, SHGG28 CONDIAMB 0 0 ❑ West 32.0 sq. R BSMT 11-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ East 16.0 sq. R FRONT 11-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ South 72.0 sq. R LEFT SIDE U-.33, SHGG28 CONDIAMB 2X4 0 0 0 West 63.0 sq. R LEFT SIDE GD U-.33, SHGG28 CONDIAMB 2X4 0 0 0 West 18.0 sq. R RIGHT SIDE U-.33, SHGG28 CONDIAMB 2X4 0 0 0 East 53.0 sq. R Glazing Library Li Name Shgc U factor I1-33, SHGC-28 028 0.330 Skylight None Present Skylight Library List None Present 3 Building Summary Property Organization 1565 LASH ST TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons CCO05 [AS DESIGNED] Builder CLAY CORNER 5 LENNAR HOMES Opaque Door Name FRONT Fiberglass Door CONDIAMB 2X4 GARAGE Fiberglass Door CONDIGAR Opaque Door Library List i Name LI -factor IFiberglass Door 0.182 C-M, Energy Solutions Inspection Status Results are projected 0.9 0.75 Medium 20.0 sq. ft Exposed Exterior 0.9 0.75 Medium 18.0 sq. fL Exposed Exterior Roof Insulation Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color P.f.] Tiles SECOND R-3S Blown_ GR1 2.123 No Medium Roof Insulation Library List Name Has Radiant Barrier '•0 .a l No Whole House Infiltratio Infiltration Measurement Type 5 ACH at 50 Pa Blower -door tested t: Mechanical Ventilation None Present RAalue 38268 4 SurfaceArea Location 2,123.0 sq. ft Attic M Building Summary Property 1565 LASH ST CARMEL, IN 46032 CCO05 [AS DESIGNED] CLAY CORNER 5 Lighting I % Interior Fluorescent Lighting Gnsite Generation Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions 100 0 100 0 100 Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Name Library Type Heating Percent Load Air conditioner CA13NA042 0% Fuel -fired air 9155A4808OS17 100% distribution Water Heating RE350" 0% Cooling Percent Load Hot Water Percent Load 100% ❑% 0% 0% ❑% 100% Building Summary Property Organization 1565 LASH ST TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CCO05 [AS DESIGNED] Builder Results are projected CLAY CORNER 5 LENNAR HOMES Equipment Type: 9155A4808OSi Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 rributi nt Type: CA13NA042 ypeiencycity [kBtulh] quipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity {gal.] Hot Water Capacity [kBtulh] Recovery Efficiency Electric Forced Air PSG (Single Speed) 13 SEER 40 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 C-M, Energy Solutions Building Summary Property Organization 1565 LASH ST TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CCO05 [AS DESIGNED] Builder Results are projected CLAY CORNER 5 LENNAR HOMES Distribution System Distribution Type Forced Air Heating Equipment Fuel-f red air distribution Cooling Equipment Air conditioner Sq. Feet Served 4246 # Return Grilles 5 Supply Duct R Value 10 Return Duct R Value 10 Supply Duct Area [sq. ft.] 1146.42 Return Duct Area [sq. ft_] 1061.5 Duct Leakage to Outdoors (CFM25) 252 Total Leakage 336 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Ceiling Fan ' Has Ceiling Fan No Cfm Per Watt 101 Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 50 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 34 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 1565 LASH ST CARMEL, IN 46032 CCO05 [AS DESIGNED] CLAY CORNER 5 Fuel Type Cef Field Utilization lothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption "M Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Electric Timer Controls 704 kWh/Year 0.0nWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year C-M, Energy Solutions ,�