HomeMy WebLinkAboutA100.7A
A507
A
A507
B
A507
B
A507
C
A507
C
A507
D
A507
D
A507
E
A507
E
A507
8'-5" 1 0'-7"
4'-8"
1 9'-0"10'-5"5'-7 1/2"9'-1 " 1 '-7" 6'-1 0"
7'-2" 4'-1 1 "
3'-6 1 /2"
2'-4"6'-6 1/2" 3'-7"10'-5"MASTER CLOSET
MASTER
BATHROOM
CLO.
#7
NMASTER BATH NOTES:
- FRAME NEW 2X4 WALLS PER PLANS
- FRAME FOR NEW 2X4 HALF WALL PER PLANS
- FRAME FOR NICHE IN SHOWER WALL PER PLANS
- FRAME FOR SHOWER BENCH PER PLANS
- CORETEC FLOORING; GOLD COAST ACACIA (BY HOMEOWNER)
- F/I NEW BASE, SHOE, WINDOW & DOOR CASINGS
- F/I NEW BATHROOM CABINETS; WELLBORN/HENLOW SQUARE/OYSTER WHITE;
HARDWARE TBD
- F/I NEW SEA OATS CULTURED MARBLE COUNTERTOP WITH INTEGRATED SINK
BOWLS
- F/I NEW SEA OATS CULTURED MARBLE SHOWER BENCH
- F/I (2) NEW SINK FAUCETS & DRAINS
- F/I NEW 42x48 WHITE SHOWER BASE W/ CENTER DRAIN
- F/I NEW TOILET
- F/I 1 2x24 OLIMPIA MIELE SHOWER WALL TILE ON 1 /3 HORIZONTAL BRICK LAY &
TRIM OUTSIDE EDGES & NICHE WITH BRUSHED NICKEL "L" CHANNEL; TEC ANTIQUE
WHITE GROUT
- F/I NEW SHOWER SUPPLY LINES & PLUMBING FIXTURES; SHOWER HEAD, VALVE, &
TRIM
- F/I FRAMELESS GLASS SHOWER DOORS WITH BRUSHED NICKEL HARDWARE
- F/I NEW DOORS; SEE DOOR SCHEDULE FOR FURTHER DETAILS
- F/I (2) NEW WALL MOUNTED MEDICINE CABINETS
- F/I (2) NEW VANITY LIGHT FIXTURES; NUVO EMPIRE 3 LIGHT IN DOWN FACING
DIRECTION
- F/I NEW BATHROOM ACCESSORIES; (1 ) 24" DOUBLE TOWEL BAR, (1 ) TISSUE
HOLDER, & (1 ) TANK LEVER; SITE VERIFY LOCATIONS WITH HOMEOWNERS
- PREP, PRIME, & PAINT WALLS, CEILING, BASE, SHOE, & CASINGS (BY
HOMEOWNER)
**ALL DIMENSIONS SHOWN ARE FROM FACE OF STUD
TO FACE OF STUD UNLESS NOTED OTHERWISE**
**ALL DIMENSIONS FOR DOOR & WINDOWS ARE TO
CENTERLINE OF ROUGH OPENING UNLESS NOTED
OTHERWISE**
PERMIT
#1
ISSUE DATE:
2019-01-30
REV:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been prepared
by Case Design & Remodeling solely
for its use and should not be
reproduced or relied upon by any
other parties. Dimensions shown or
scaled are subject to change per
actual job condition and must be
verified. Materials are to be supplied
as specified as equal or standard
when not uniquely specified. Installed
materials may vary in appearance
from drawings. Reference
manufacturer's product data for actual
appearance and specifications.HENTZ RESIDENCEHOUSE ADDITION &RENOVATION
PETER & MARGARET HENTZ13919 SHELBOURNE ROADCARMEL, INDIANA 46074Approved By:
Date:
A403
Craig Dice
Designer
cdice@caseindy.com
Dave Null
Lead Designer
dnull@caseindy.com
Katie Kramer
Designer
kkramer@caseindy.com
232160199
JOB NUMBER:
ENLARGED MASTER BATHROOM & MASTER CLOSET PLAN
SCALE: 3/8" = 1'
#2 2019-02-27
#3 2019-03-11
03/22/19
Adam Schriner