Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S 100 0
Layout Name 10 Woodside West Clay-5820 B Description 10 Woodside West Clay 5820-B Created March 06, 2019 Revised March 14, 2019 Builder David Weekley Homes Sales Rep Freddie Clapper Designer Paul Cavote Contract Lumber 200 Schofield Drive Columbus , OH 43213 614.751.1109 Main I Joist (Flush) Label Description Width Depth Qty Plies Pcs Length J1 LPI 18 2.5 11.875 1 7-0-0 J2 LPI 18 2.5 11.875 4 11-0-0 J3 LPI 18 2.5 11.875 4 13-0-0 J4 LPI 18 2.5 11.875 2 18-0-0 J5 LPI 18 2.5 11.875 10 30-0-0 J6 LPI 18 2.5 11.875 8 27-0-0 J7 LPI 18 2.5 11.875 8 28-0-0 J8 LPI 18 2.5 11.875 6 19-0-0 J9 LPI 18 2.5 11.875 19 32-0-0 LVL/LSL (Flush) Label Description Width Depth Qty Plies Pcs Length F1 LP-LSL 1.55E 1.75 11.875 1 4-0-0 F2 LP-LSL 1.55E 1.75 11.875 1 5-0-0 LVL/LSL (Dropped) Label Description Width Depth Qty Plies Pcs Length DB1 LP-LSL 1.55E 1.75 11.875 1 2 2 8-0-0 DB2 LP-LVL 2900Fb-2.0E 1.75 11.875 2 3 6 27-0-0 Rim Board Label Description Width Depth Qty Plies Pcs Length R1 LP APA Rated OSB 1.125 X 11.875 1.125 11.875 22 12 Lumber (Dropped) Label Description Width Depth Qty Plies Pcs Length DB3 SP #2 1.5 11.25 1 4 4 18-0-0 Main Design Method ASD Building CodeIBC/IRC 2015 Floor Loads Live 40 Dead 10 Deflection Joist LL Span L/ 480 TL Span L/ 240 LL Cant 2L/ 480 TL Cant 2L/ 240 Deflection Girder LL Span L/ 480 TL Span L/ 240 LL Cant 2L/ 480 TL Cant 2L/ 240 Decking Deck OSB 23/32 APA Rated Sturd- I-Floor Fastener Nailed & Glued 13'5" 13'4" 13'4"15' 8'4"12' SHIFT JOIST 4" TO AVOID PLBG 19.2" O.C.START LAYOUTSE EMPIEZA AQUI30"x30" 36"x36" 36"x36" 36"x36" 3 -2x6 5 -2x6 5 -2x6 5 -2x6 5 -2x6 A3 A3 A3 A3 A3 A3 A3 A7 A7 A7 A7 A7 B5-0 B5-0 EXTRA JOISTS UNDER KITCHEN ISLAND ABOVE 19.2" 9.6" 9.6"J1 J2 @ 19.2"J8 @ 19.2"J3 @ 19.2"2 X J42 X J5J5 @ 19.2"2 X J6 J6J6 @ 19.2"J9 @ 19.2"J9 J7 @ 19.2"J9J9 @ 19.2"DB1 ( 2 ply )F2 ( 1 ply ) F1 ( 1 ply )DB3 ( 4 ply )DB2 ( 3 ply )DB2 ( 3 ply ) PS PS PS PS PS PS General Notes - It is the sole responsibility of the builder/installer to follow this layout exactly. Notify Contract Lumber of any discrepancies between this layout and field conditions. Contract Lumber is not liable for any field changes without prior approval. - Refer to details in the installation guide prior to construction Version 18.80.219 Powered by iStruct® This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them 03/22/19 Mike Sheeks Layout Name 10 Woodside West Clay-5820 B Description 10 Woodside West Clay 5820-B Created March 06, 2019 Revised March 14, 2019 Builder David Weekley Homes Sales Rep Freddie Clapper Designer Paul Cavote Contract Lumber 200 Schofield Drive Columbus , OH 43213 614.751.1109 Roof LVL/LSL (Dropped) Label Description Width Depth Qty Plies Pcs Length DB5 LP-LVL 2900Fb-2.0E 1.75 9.5 1 2 2 18-0-0 DB6 LP-LVL 2900Fb-2.0E 1.75 9.5 1 3 3 31-0-0 DB7 LP-LVL 2900Fb-2.0E 1.75 9.5 2 2 4 11-0-0 D3 LP-LVL 2900Fb-2.0E 1.75 11.875 1 3 3 13-0-0 D4 LP-LVL 2900Fb-2.0E 1.75 11.875 1 2 2 20-0-0 Lumber (Dropped) Label Description Width Depth Qty Plies Pcs Length D5 SP #2 1.5 5.5 9 4-0-0 D7 SP #2 1.5 7.25 3 4-0-0 D1 SP #2 1.5 9.25 1 2 2 4-0-0 D6 SP #2 1.5 9.25 4 4-0-0 D2 SP #2 1.5 11.25 1 2 2 6-0-0 Roof Design Method ASD Building CodeIBC/IRC 2015 Floor Loads Live 0 Dead 20 Snow 20 Deflection Joist LL Span L/ 360 TL Span L/ 240 LL Cant 2L/ 360 TL Cant 2L/ 240 Deflection Girder LL Span L/ 360 TL Span L/ 240 LL Cant 2L/ 360 TL Cant 2L/ 240 Decking Deck OSB 5/8 APA Rated Sturd- I-Floor Fastener Nailed Only 2 JACKS REQ. 2 JACKS REQ. 2 JACKS REQ. 2 JACKS REQ. 2 JACKS REQUIRED GIRDER TRUSS GIRDER TRUSS GIRDER GIRDER GIRDERHIP T R U S S HIP TRUSSHIP TRUSSH IP TR U S S DB7 ( 2 ply ) DB7 ( 2 ply )DB5 ( 2 ply )GIRDER TRUSS GIRDER TRUSS DB6 ( 3 ply )D5 ( 1 ply ) D5 ( 1 ply ) D5 ( 1 ply )D5 ( 1 ply )D5 ( 1 ply ) D5 ( 1 ply ) D5 ( 1 ply )D5 ( 1 ply ) D5 ( 1 ply )D3 ( 3 ply ) D4 ( 2 ply )D2 ( 2 ply ) D1 ( 2 ply ) D6 ( 1 ply ) D6 ( 1 ply )D6 ( 1 ply ) D6 ( 1 ply )D7 ( 1 ply )D7 ( 1 ply ) D7 ( 1 ply ) General Notes - It is the sole responsibility of the builder/installer to follow this layout exactly. Notify Contract Lumber of any discrepancies between this layout and field conditions. Contract Lumber is not liable for any field changes without prior approval. - Refer to details in the installation guide prior to construction Version 18.80.219 Powered by iStruct® This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them 03/22/19 Mike Sheeks