Loading...
HomeMy WebLinkAboutSANCT 73 PLOT PLANSTOEPPELWERTH ALWAYS ON N 7965 East 106th Street, Fishers, IN 46038-2505 phone:317.849.5935 fox:317.849.5942 LOT 73 THE SANCTUARY AT 116TH STREET SECTION 213 INST #2018052833 P.C. #5 SLIDE #899 4402 EAGLERIDGE LANE ZIONSMLLE, IN 46077 1 of = 30' LOT AREA:8,584 Sq. Ft. M.F.P.G.=908.4 M.L.A.G.=908.4 M.F.F F LOT 110 EXIST. HSE 05.7 BLOCK "A" D.&U.E.,S.S.E. 74.00 iC, o W � o MORNING 08.6 ROOM 08. 20.80' b o o COVERED ftool 0 Sri 16.0' 0 PATIO o 1 0 O 20.00' O O MODEL= CAROLINA PLACE K o F.F.ELEV,= 910.47 0 T.O.W.= 909.27 0 )6.8 BSMT.- 901.6o (RH) (VERSION 02) 32.0' o �6.00 GAR. 0 11.29' SOD LINE 12.71' N o 08.6 POR o JOB ID SANCT26.73 CONTROL# 8.0' 86072 RYAN APPROX. 12.9' FROM TAP TO HOUSE T.C.= 906.83 � 16' SOD LINE MH SNM858 AS BUILT o v m ° DRIVE o20 D.&U.E.,S.S.E. SNT840 ul O� 0. T.C.= 907.11 T.C.= 906.85 AS BUILT 06.3 74.00 5'SW AS BUILT LEGEND: XX.X PROPOSED GRADE PER PLAN XX.XAB AS BUILT GRADE S.S.D. _ _ SUB -SURFACE DRAIN SANITARY SEWER STORM SEWER W WATER MAIN W 3/4" WATER CONNECTION ° ° ° < SWALE • SANITARY MANHOLE /•J STORM MANHOLE ■ CURB INLET FIRE HYDRANT EMERGENCY FLOOD ROUTE D.&U.E., S.S.E. DRAINAGE & UTILITY EASEMENT SANITARY SEWER EASEMENT D.&U.E. DRAINAGE & UTILITY EASEMENT B.L. BUILDING LINE M.F.F. MINIMUM FINISHED FLOOR ELEVATION M.L. A.G. MINIMUM LOWEST ADJACENT GRADE M.F.PG MINIMUM FLOOD PROTECTION GRADE T.O.W. TOP OF WALL T.C.= 905.91 01 (J� AS BUILT � ERIDGE o00 05.98 a LANE o6.39 T.C.= 905.92 AS BUILT EPp ALL UNDERGROUND SEWERS AND UTILITIES ���� , • ,.•• ""' •.. �� '�i, '. SHOWN ARE PLOTTED BY SCALE FROM "RECORD DRAWINGS" FURNISHED BY ENGINEER. �` Q ;: �G\STEgF •.11i Q N0. :—A: BENCHMARK =_ 80040474 TOP OF CASTING = 905.92 STATE OF SOD: 254 t Sq. Yd. ���,�� SUR�..y SEEDING: 3,874 t Sq. Ft. .,�. CONC. DRIVEWAY: 432 f Sq. Ft. ���nnnnn��•� PRIVATE WALK: 32 f Sq. Ft. PUBLIC WALK: 290 t Sq. Ft. APRON: 232t Sq. Ft. ZONING: S-1 /RESIDENCE — ROSO III WITH WAIVERS NOTE: THIS DRAWING IS NOT INTENDED TO BE 25' MINIMUM FRONT YARD (GARAGE) REPRESENTED AS A RETRACEMENT OR ORIGINAL 0' MINIMUM SIDE YARD BOUNDARY SURVEY, A ROUTE SURVEY OR A 6' MINIMUM BETWEEN STRUCTURE SURVEYOR LOCATION REPORT. 0' MINIMUM REAR YARD NOTE: SIDE/REAR SETBACKS & MINIMUM BUILDING SEPARATION SHALL BE INCREASED 03/07/19 CEJ BY ONE (1) FOOT FOR EACH ADDITIONAL (1) FOOT ` A STRUCTURE IS RAISED ABOVE THE TWENTY—FIVE (25) FOOT HEIGHT STANDARD— WITH NO STRUCTURE0 EXCEEDING THIRTY—FIVE (35) FEET IN HEIGHT KFwwwneisbelow. Call before you dig.