Loading...
HomeMy WebLinkAboutSY 73 sewerSlab Foundation Crawl Space Basement 10701 N. College Avenue Suite A Indianapolis, Indiana 46280 phone 317-844-9200 fax 317-844-9203 www.trico.eco Residential SANITARY SEWER PERMIT 9999/3/92 Permit Type Final Subdivision Sanctuary at 116th St Project WO 2018-1367 Section Number 2B Project Name Sanctuary at 116th Street Section 2B Lot Number 73 Project Developer CESO Inc. Address Number 4402 Lift Station 17 Zion Hills Station Address 2 Treatment Plant Parcel Acreage EDU in Gallons Local Sewer Charge - District Contribution Plan Review and Inspection Application Fee EDU Fee Interceptor Fee Other Fees Fees Due Invoice Number CTRWD WWTP Street 0.20 City 310 Zip Code County 0.00 Builder 0.00 150.00 Phone Number 1908.00 Owner 0.00 phone Number 0.00 2058.00 Occupant Phone Number Eagleridge Lane Zionsville 46077 Hamilton Ryan Homes 317-371-6577 PLEASE NOTE: Installation of building sewer shall be per the specifications of the TriCo Regional Sewer Utility (see reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench" phase and before backfilling with stone to twelve inches above the pipe, NO footing or foundation drains, or other sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TriCo will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and the like; caused by construction activity on the building site which is the subject of this permit. Inspections by ThCo are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in advance. All new construction will be placed on billing two months after connection has been made or when water is connected, whichever comes first. The building has: Grease Trap Grease Interceptor Grit Interceptor Grinder Station Main ID: Manhole IDs uSMH SNT840-SNT858 SNT-840 SNT-858 DSMH 906.85 f 906.93 910.47 J/ 910.47 -1 Water Service City of Carmel Basement Elevation 901.61 f 901.61 Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor 3.62 3.54 Ft. Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only TriCo currently requires that an I&I ins T1t,z7 i.-„ pt­r`(-,(;au and a CE;rtificato of Compliance is issued prior.to occupancy/ sale of a properrty. Please review attae sci /l Pe;�,i Manholes shall remain accessible at a'l tin ins. Fur'ier : will be corrected by the Developer/Owner. — The proper class of cleanout must be inst�?ie.d :vver; lateral pipe measured from sewer main to structure - The terms of the conditional permit, if any, are: listec. f.c r7w. Plans have been submitted. All fees have been paid_ No certificate of insurance required. No additional permits required. No manhole core permit required. The facility is not classified as a FOG facility. YES!Lid Elevation 1=irst Floor Elevation (Notes) By signing below, I attest that I am fa War with the Di dct' pacification and agree to accept responsibility for all work done under this permit. Builder / Owner Signature Phone Number S-27 Printed Name 6, God r Approved By -t Ryan an, !strict � r + s Permit is valid f r 0 E-YEAR from the date issued. Permit valid only with Tri V m ?