HomeMy WebLinkAbout64859-W1 SEALED 1903478-12TAll Hangers connections are LUS24's. The
T03 to G03 hangers are upset 1-11/16".
12" knee wall required to get 5" sidewall at the room.
12" knee wall required to get 5" sidewall at the room.
BBO1BBO2 BBO3BBO4
BBO5
BBO6BBO7GE01GE02G01G04T01G02
G03
G03
G02 T02T02T03 T03 T02 T02 GE02T01(20)
P01(22) P01(3)4' 9 3/4" 17' 5" 4' 9 3/4"27' 0 1/2"49' 6 1/2"
2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"1' 5"2' 0 3/4"4' 0" 4' 8 1/2" 4' 0"2' 0 3/4"
2' 11"4' 0"2' 11"
1317 N. Owen Street
Rensselaer, IN 47978
1-800-866-7658
Designer: mbbraddock
JOBNAME:
CUSTOMERNAME:
Old Town Design Group
14
Blackwell Park
Contract Lumber
Brownsburg, IN
JOB#: 1903478-12T
DATE: 3/20/2019
JOBNOTES:
All Hangers connections are
LUS24's. The T03 to G03
hangers are upset 1-11/16".
Trusses are 24" on center
except as shown on this
drawing.
Please note that a 12" knee
wall is required for the wall
to be 5' tall at the room.
General Notes:
THIS IS A TRUSS PLACEMENT DIAGRAM ONLY.
These trusses are designed as individual building components
to be incorporated into the building design at the specification
of the Building Designer whose responsibilities include; the
design and bracing of the overall structure, any supporting
structure including the walls, headers, beams and columns and
the permanent bracing of the roof and floor system. The
General Contractor and/or their agents are responsible for; the
verification of all dimensions, assuring that any conventional
framing shall uniformly transfer the loads to the trusses below,
the temporary bracing of the truss system as well as the
permanent web bracing shown on the individual truss drawing
sheets for the truss designs identified on this placement plan.
For general guidance regarding bracing, consult "Bracing of
Wood Trusses" available from the Truss Plate Institute 583
D'Onofrio Drive, Madison, WI 53179.
COMPANY, INC.
STARK
TRUSS
Dansco Engineering, LLC
P.O. Box 3400
Apollo Beach, FL 33572
This truss placement diagram (TPD) has been prepared by component manufacturer
technician(s) and reviewed by DANSCO Engineering, LLC for the design criteria shown
on this TPD. DE accepts responsibility for specifying truss-to-truss connections within
the truss system only. DE is not responsible for the design of this structure, for
specifying permanent truss bracing, for specifying the attachment of the trusses and
bracing to the structure, nor for specifying the diaphragm or sheathing (including
attachment to the trusses) - these items are the responsibility of the design professional
of record (engineer or architect of record). Review and approval of the design criteria
shown is the responsibility of the design professional of record. The contractor shall be
responsible for field verification of all dimensions, for means and methods of
construction, for temporary bracing of the trusses, and for coordination of the work of all
trades. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected
Wood Truss Construction and TPI/WTCA BCSI-06, Building Component Safety
Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of
Metal Plate Connected Wood Trusses for additional information.
Dansco Engineering, LLC
P.O. Box 3400
Apollo Beach, FL 33572
Date: 3/21/19
DE Job# 64859-W1
04/08/19
Mike Sheeks
DE
DANSCO ENGINEERING, LLC
P.O. Box 3400
Apollo Beach, FL 33572
Telephone (813) 645-0166
Facsimile (813) 645-9698
The truss drawing(s) attached have been prepared by Dansco Engineering, LLC under
my direct supervision and control based on the parameters provided by Stark Truss Inc.
Job: 1903478-12T
9 truss design(s)
64859-W1
3/20/19
Samuel A. Greenberg, P.E.
Indiana Reg. #19700485
Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural
gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length
is the distance from the top chord to bottom chord.
The seal on these drawings indicate acceptance of professional engineering
responsibility solely for the truss components shown. The suitability and use of this
component for any particular building is the responsibility of the building designer, per
ANSI/TPI 1-2014 Chapter 2.
Warning !—Verify design parameters and read notes before use.
These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of
design parameters and proper incorporation of component is responsibility of building designer not truss designer or truss engineer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication,
quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss
Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate
Institute, 583 DOnofrio Drive, Madison, WI 53719
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
G04
Truss Type
Piggyback Base Girder
Qty
1
Ply
2 Job Reference (optional)
8.200 s Apr 7 2018 MiTek Industries, Inc. Wed Mar 20 17:13:44 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-EmF9H0ujaSa6WnoppsHFgT6KoEyh2Hao_EPSivzZ_jr
Scale = 1:81.9
T1
T2
T3
B1 B2
W1
W2
W3
W4
W5
W6 W7
W8
W9
W10
W11
W12
EV1
WCL2
EV2
WCR2
T4 T5
B3
1
2
3
4
5
6 7
8
9
10
11
12
23
22
21
20
19
18
17
16
15
14
13
24 25
4x6
6x16 MT18H 6x16 MT18H
4x6
4x6
8x8
4x6
3x6
3x10
4x10
4x12
3x8 3x8
4x12
4x10
3x6
3x10
2x4
4x6
2x4
4x6
3-8-4
3-8-4
7-1-0
3-4-12
11-0-0
3-11-0
13-6-4
2-6-4
16-0-8
2-6-4
19-11-8
3-11-0
23-4-4
3-4-12
27-0-8
3-8-4
-0-10-8
0-10-8
3-8-4
3-8-4
7-1-0
3-4-12
11-0-0
3-11-0
16-0-8
5-0-8
19-11-8
3-11-0
23-4-4
3-4-12
27-0-8
3-8-4
27-11-0
0-10-8
2-0-013-0-02-0-011-0-5
12.0012
10.0012
Plate Offsets (X,Y)-- [6:1-1-8,0-3-0], [7:1-1-8,0-3-0], [18:0-4-0,0-5-4]
LOADING (psf)
TCLL (roof)
Snow (Pf/Pg)
TCDL
BCLL
BCDL
20.0
23.1/30.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-S
0.21
0.33
0.74
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.26
-0.47
0.85
0.18
(loc)
18
18
13
18
l/defl
>999
>680
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT18H
Weight: 480 lb FT = 20%
GRIP
197/144
197/144
LUMBER-
TOP CHORD2x6 SP 2400F 2.0E
BOT CHORD2x6 SP 2400F 2.0E
WEBS 2x4 SPF Stud *Except*
W3,W10: 2x8 SP 2400F 2.0E, W5,W8: 2x6 SPF No.2
W6,W7: 2x4 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-7.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size)23=2375/0-3-8 (min. 0-1-8), 13=2375/0-3-8 (min. 0-1-8)
Max Horz23=254(LC 31)
Max Uplift23=-309(LC 10), 13=-309(LC 10)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4771/591, 3-4=-6960/922, 4-5=-7127/867, 5-6=-7054/881, 6-24=-11907/1374,
24-25=-11907/1374, 7-25=-11907/1374, 7-8=-7054/796, 8-9=-7127/782,
9-10=-6960/762, 10-11=-4771/538, 2-23=-2339/312, 11-13=-2339/312
BOT CHORD 22-23=-336/369, 21-22=-671/4391, 20-21=-924/6455, 19-20=-901/6503,
18-19=-781/6312, 17-18=-666/6303, 16-17=-616/6455, 15-16=-638/6407,
14-15=-352/4261
WEBS 3-22=-1442/208, 3-21=-188/1655, 4-21=-404/8, 4-19=-47/265, 6-19=-248/909,
6-18=-825/7887, 7-18=-925/7887, 7-17=-248/926, 9-17=-199/265, 9-15=-417/30,
10-15=-223/1655, 10-14=-1442/173, 2-22=-374/3426, 11-14=-292/3426
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=27ft; eave=4ft; Cat. II;
Exp B; enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
5) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=30.0 psf (ground snow); Pf=23.1 psf (flat roof
snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0
6) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 23.1 psf on overhangs
non-concurrent with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) All plates are MT20 plates unless otherwise indicated.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
Continued on page 2
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
G04
Truss Type
Piggyback Base Girder
Qty
1
Ply
2 Job Reference (optional)
8.200 s Apr 7 2018 MiTek Industries, Inc. Wed Mar 20 17:13:44 2019 Page 2Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-EmF9H0ujaSa6WnoppsHFgT6KoEyh2Hao_EPSivzZ_jr
NOTES-
11) Bearing at joint(s) 23, 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 309 lb uplift at joint 23 and 309 lb uplift at joint 13.
13) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
15) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 686 lb down and 181 lb up at 7-1-4, 468 lb down and 141 lb up at 11-2-12
, and 468 lb down and 141 lb up at 15-9-12, and 686 lb down and 181 lb up at 19-11-4 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
16) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-66, 2-6=-66, 6-7=-66, 7-11=-66, 11-12=-66, 18-23=-20, 13-18=-20
Concentrated Loads (lb)
Vert: 21=-686(B) 19=-468(B) 17=-468(B) 15=-686(B)
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
G02
Truss Type
Flat Girder
Qty
2
Ply
1
Job Reference (optional)
Run: 81.200 s 20 Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Tue Mar 19 10:55:37 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-mDHmJNjHjTmHlRq9s8hyyDY8HbkyHqB8TxuYSGzZPMK
Scale = 1:19.5
EV1
T1
EV2
B1
W1
1 2
4
35
2x4
4x4
2x4
4x4
0-3-8
0-3-8
3-10-8
3-7-0
4-2-0
0-3-8
0-3-8
0-3-8
3-10-8
3-7-0
4-2-0
0-3-8
3-3-12LOADING (psf)
TCLL (roof)
Snow (Pf/Pg)
TCDL
BCLL
BCDL
20.0
23.1/30.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.22
0.30
0.02
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.02
-0.00
0.01
(loc)
3-4
3-4
3
3-4
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 25 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD2x6 SPF No.2
BOT CHORD2x6 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size)4=404/Mechanical, 3=640/Mechanical
Max Horz4=-72(LC 6)
Max Uplift4=-105(LC 6), 3=-195(LC 7)
Max Grav4=416(LC 33), 3=666(LC 32)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II;
Exp B; enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=30.0 psf (ground snow); Pf=23.1 psf (flat roof
snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=105,
3=195.
8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 281 lb down and 118 lb up at
1-9-12, and 289 lb down and 110 lb up at 4-0-4 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-110(F=-44), 3-4=-20
Concentrated Loads (lb)
Vert: 3=-274(B) 5=-266(B)
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
G03
Truss Type
Flat Girder
Qty
2
Ply
1
Job Reference (optional)
Run: 81.200 s 20 Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Tue Mar 19 10:55:38 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-EPr9WjkvUnu8MbPMQrCBUR5I1?4q0HEIhbe5_izZPMJ
Scale = 1:23.0
EV1
T1
EV2
B1
W1
1 2
4
35
2x4
4x4
2x4
4x4
0-3-8
0-3-8
3-10-8
3-7-0
4-2-0
0-3-8
0-3-8
0-3-8
3-10-8
3-7-0
4-2-0
0-3-8
4-0-0LOADING (psf)
TCLL (roof)
Snow (Pf/Pg)
TCDL
BCLL
BCDL
20.0
23.1/30.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.22
0.20
0.03
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.01
-0.00
0.01
(loc)
3-4
3-4
3
3-4
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 27 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD2x6 SPF No.2
BOT CHORD2x6 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size)4=343/Mechanical, 3=488/Mechanical
Max Horz4=-90(LC 8)
Max Uplift4=-84(LC 6), 3=-121(LC 7)
Max Grav4=366(LC 33), 3=526(LC 32)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II;
Exp B; enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=30.0 psf (ground snow); Pf=23.1 psf (flat roof
snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 3=121.
8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 176 lb down and 56 lb up at
1-9-12, and 184 lb down and 48 lb up at 4-0-4 on bottom chord. The design/selection of such connection device(s) is the responsibility
of others.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-110(F=-44), 3-4=-20
Concentrated Loads (lb)
Vert: 3=-168(F) 5=-160(F)
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
GE01
Truss Type
Common Supported Gable
Qty
1
Ply
1
Job Reference (optional)
Run: 81.200 s 20 Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Tue Mar 19 10:55:38 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-EPr9WjkvUnu8MbPMQrCBUR5Em?4Q0EdIhbe5_izZPMJ
Scale = 1:65.5
EV1
T1 T2
EV2
B1
ST1
ST2
ST3
ST4
ST5
ST6
ST7
1
2
3
4
5
6
7
8
9
10
11
20 19 18 17 16 15 14 13 12
4x4
3x5
4x4
3x5
4x4
0-3-8
0-3-8
14-2-8
13-11-0
14-6-0
0-3-8
-0-10-8
0-10-8
0-3-8
0-3-8
7-3-0
6-11-8
14-2-8
6-11-8
14-6-0
0-3-8
15-4-8
0-10-8
3-4-410-7-43-4-412.0012
Plate Offsets (X,Y)-- [12:Edge,0-3-8]
LOADING (psf)
TCLL (roof)
Snow (Pf/Pg)
TCDL
BCLL
BCDL
20.0
23.1/30.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-R
0.49
0.22
0.20
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.01
-0.00
(loc)
11
11
12
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 104 lb FT = 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud *Except*
ST1,ST2,ST5: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 6-16, 5-17, 7-15
with 2x4 SPF Stud with 2 - 10d (0.131"x3") nails and cross brace
spacing of 20-0-0 oc.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 14-6-0.
(lb) - Max Horz20=-223(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 15, 14 except 20=-299(LC
12), 12=-295(LC 13), 19=-284(LC 13), 13=-280(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 17, 18, 15, 14 except
20=386(LC 13), 12=382(LC 12), 16=372(LC 14), 19=421(LC 12), 13=417(LC 13)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-6=-219/311, 6-7=-219/311
WEBS 6-16=-384/198
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II;
Exp B; enclosed; MWFRS (directional) and C-C Corner(3) -0-10-8 to 2-1-8, Exterior(2) 2-1-8 to 7-3-0, Corner(3) 7-3-0 to 10-3-0 zone;
cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=30.0 psf (ground snow); Pf=23.1 psf (flat roof
snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 23.1 psf on overhangs
non-concurrent with other live loads.
6) All plates are 1.5x4 MT20 unless otherwise indicated.
7) Gable requires continuous bottom chord bearing.
8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
9) Gable studs spaced at 2-0-0 oc.
10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
Continued on page 2
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
GE01
Truss Type
Common Supported Gable
Qty
1
Ply
1
Job Reference (optional)
Run: 81.200 s 20 Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Tue Mar 19 10:55:39 2019 Page 2Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-ibPXj3lXF40?_l_Y_ZjQ1eePWPQflhtRwFNeW8zZPMI
NOTES-
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 15, 14 except (jt=lb) 20=299, 12=295, 19=284,
13=280.
13) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
14) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
GE02
Truss Type
GABLE
Qty
2
Ply
1
Job Reference (optional)
Run: 81.200 s 20 Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Tue Mar 19 10:55:40 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-AozvxPl9?O8scvZkYGEfasAc_ploUz1b9v7C2azZPMH
Scale = 1:76.4
T1
T2
T3
B1 B2
W1
W2
W3
W4 W5
W6
W7
W8
EV1
WCL2
EV2
WCR2
T4 T5B3B4
ST1
ST2
ST3 ST4
ST5ST6
ST7
ST8
ST9
ST10
ST11
ST12
ST13
1 2
3
4
5 6
7
8
9
10
19
18
17
16
15
14
13
12
11
41
42
43 44
45
46
6x8 6x8
4x4
8x8 4x4
3x6
6x6
3x5
3x5
3x6
6x6
3x4
5x8
3x4
5x8
2x4
5x6 5x6
0-3-8
0-3-8
5-6-4
5-2-12
11-0-0
5-5-12
13-6-4
2-6-4
16-0-8
2-6-4
21-6-4
5-5-12
26-9-0
5-2-12
27-0-8
0-3-8
-0-10-8
0-10-8
0-3-8
0-3-8
5-6-4
5-2-12
11-0-0
5-5-12
16-0-8
5-0-8
21-6-4
5-5-12
26-9-0
5-2-12
27-0-8
0-3-8
27-11-0
0-10-8
2-0-013-0-02-0-011-0-5
12.0012
10.0012
Plate Offsets (X,Y)-- [2:0-3-4,0-1-8], [4:0-3-0,0-3-0], [5:0-6-1,0-3-0], [6:0-6-1,0-3-0], [7:0-3-0,0-3-0], [9:0-3-4,0-1-8], [25:0-1-12,0-0-12], [36:0-1-12,0-0-12]
LOADING (psf)
TCLL (roof)
Snow (Pf/Pg)
TCDL
BCLL
BCDL
20.0
23.1/30.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-S
0.38
0.29
0.84
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.28
-0.53
0.96
0.10
(loc)
15
15
11
15
l/defl
>999
>607
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 188 lb FT = 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 SP 2400F 2.0E *Except*
T2: 2x6 SPF No.2
BOT CHORD2x4 SP 2400F 2.0E
WEBS 2x4 SPF Stud *Except*
W4,W5: 2x4 HF/SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-6-8 oc purlins, except
end verticals, and 2-0-0 oc purlins (3-1-11 max.): 5-6.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size)19=1221/0-3-8 (min. 0-1-8), 11=1221/0-3-8 (min. 0-1-8)
Max Horz19=259(LC 13)
Max Uplift19=-3(LC 14), 11=-3(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-41=-2722/9, 3-41=-2609/38, 3-42=-3030/0, 4-42=-2937/0, 4-5=-2888/0,
5-43=-4776/0, 43-44=-4776/0, 6-44=-4776/0, 6-7=-2888/0, 7-45=-2937/0,
8-45=-3030/0, 8-46=-2600/10, 9-46=-2722/0, 2-19=-1226/91, 9-11=-1222/115
BOT CHORD 18-19=-330/411, 17-18=-46/2625, 16-17=0/2743, 15-16=0/2774, 14-15=0/2651,
13-14=0/2620, 12-13=0/2431
WEBS 3-18=-519/37, 3-17=-212/341, 5-15=0/3197, 6-15=0/3322, 8-13=-228/353,
8-12=-519/32, 2-18=0/1962, 9-12=0/1962
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=27ft; eave=4ft; Cat. II;
Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 11-0-0, Exterior(2) 11-0-0 to 20-3-7,
Interior(1) 20-3-7 to 27-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=30.0 psf (ground snow); Pf=23.1 psf (flat roof
snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0
5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 23.1 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are 1.5x4 MT20 unless otherwise indicated.
8) Gable studs spaced at 2-0-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
11) Bearing at joint(s) 19, 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 11.
Continued on page 2
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
GE02
Truss Type
GABLE
Qty
2
Ply
1
Job Reference (optional)
Run: 81.200 s 20 Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Tue Mar 19 10:55:40 2019 Page 2Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-AozvxPl9?O8scvZkYGEfasAc_ploUz1b9v7C2azZPMH
NOTES-
13) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
15) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
P01
Truss Type
GABLE
Qty
25
Ply
1
Job Reference (optional)
Run: 81.200 s 20 Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Tue Mar 19 10:55:41 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-e_XH8lmomiGjD38x5zlu63jsjD90DdTkOZslb1zZPMG
Scale = 1:17.2
T1 T2
B1
ST1
1 2
3
45
6
4x4
2x4 2x41.5x4
5-0-8
5-0-8
2-6-4
2-6-4
5-0-8
2-6-4
0-5-32-4-100-1-10
2-6-00-5-30-1-10
12.0012
Plate Offsets (X,Y)-- [2:0-2-6,0-1-0], [4:0-2-6,0-1-0]
LOADING (psf)
TCLL (roof)
Snow (Pf/Pg)
TCDL
BCLL
BCDL
20.0
23.1/30.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.06
0.04
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.00
0.00
0.00
(loc)
4
5
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 15 lb FT = 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-0-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size)2=166/3-10-14 (min. 0-1-8), 4=166/3-10-14 (min. 0-1-8), 6=49/3-10-14 (min. 0-1-8)
Max Horz2=-40(LC 12)
Max Uplift2=-19(LC 14), 4=-19(LC 14)
Max Grav2=166(LC 1), 4=166(LC 1), 6=98(LC 5)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II;
Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=30.0 psf (ground snow); Pf=23.1 psf (flat roof
snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 23.1 psf on overhangs
non-concurrent with other live loads.
6)Gable requires continuous bottom chord bearing.
7)Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
11) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
13) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
T01
Truss Type
Piggyback Base
Qty
21
Ply
1
Job Reference (optional)
Run: 81.200 s 20 Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Tue Mar 19 10:55:42 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-6A5fM5nQX?OarCi7fhG7fHGyUcRGytXtcDcJ7TzZPMF
Scale = 1:76.4
T1
T2
T3
B1 B2
W1
W2
W3
W4 W5
W6
W7
W8
EV1
WCL2
EV2
WCR2
T4 T5B3B4
1 2
3
4
5 6
7
8
9
10
19
18
17
16
15
14
13
12
11
20
21
22 23
24
25
3x4
6x8 6x8
3x4
4x4
8x8 4x4
3x6
6x6
3x5
3x5
3x6
6x6
3x4
5x8
3x4
5x8
0-3-8
0-3-8
5-6-4
5-2-12
11-0-0
5-5-12
13-6-4
2-6-4
16-0-8
2-6-4
21-6-4
5-5-12
26-9-0
5-2-12
27-0-8
0-3-8
-0-10-8
0-10-8
0-3-8
0-3-8
5-6-4
5-2-12
11-0-0
5-5-12
16-0-8
5-0-8
21-6-4
5-5-12
26-9-0
5-2-12
27-0-8
0-3-8
27-11-0
0-10-8
2-0-013-0-02-0-011-0-5
12.0012
10.0012
Plate Offsets (X,Y)-- [2:0-3-4,0-1-8], [5:0-6-1,0-3-0], [6:0-6-1,0-3-0], [9:0-3-4,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf/Pg)
TCDL
BCLL
BCDL
20.0
23.1/30.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-S
0.38
0.29
0.84
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.28
-0.53
0.96
0.10
(loc)
15
15
11
15
l/defl
>999
>607
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 163 lb FT = 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 SP 2400F 2.0E *Except*
T2: 2x6 SPF No.2
BOT CHORD2x4 SP 2400F 2.0E
WEBS 2x4 SPF Stud *Except*
W4,W5: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-6-8 oc purlins, except
end verticals, and 2-0-0 oc purlins (3-1-11 max.): 5-6.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size)19=1221/0-3-8 (min. 0-1-8), 11=1221/0-3-8 (min. 0-1-8)
Max Horz19=259(LC 13)
Max Uplift19=-3(LC 14), 11=-3(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-20=-2722/9, 3-20=-2609/38, 3-21=-3030/0, 4-21=-2937/0, 4-5=-2888/0,
5-22=-4776/0, 22-23=-4776/0, 6-23=-4776/0, 6-7=-2888/0, 7-24=-2937/0,
8-24=-3030/0, 8-25=-2600/10, 9-25=-2722/0, 2-19=-1226/91, 9-11=-1222/115
BOT CHORD 18-19=-330/411, 17-18=-46/2625, 16-17=0/2743, 15-16=0/2774, 14-15=0/2651,
13-14=0/2620, 12-13=0/2431
WEBS 3-18=-519/37, 3-17=-212/341, 5-15=0/3197, 6-15=0/3322, 8-13=-228/353,
8-12=-519/32, 2-18=0/1962, 9-12=0/1962
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=27ft; eave=4ft; Cat. II;
Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 11-0-0, Exterior(2) 11-0-0 to 20-3-7,
Interior(1) 20-3-7 to 27-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=30.0 psf (ground snow); Pf=23.1 psf (flat roof
snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0
4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 23.1 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Bearing at joint(s) 19, 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 11.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
12) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
T02
Truss Type
Monopitch
Qty
4
Ply
1
Job Reference (optional)
Run: 81.200 s 20 Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Tue Mar 19 10:55:43 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-aMf1ZQo2IJWRTMHJDOoMBUoAg0lihWb1rtLsfvzZPME
Scale = 1:55.1
T1
EV2
B1
EV1
WCL2
B2
1
2
3
4
6
5
7
1.5x4
1.5x4
4x10
3x6
2x4
0-3-8
0-3-8
6-9-0
6-5-8
7-0-8
0-3-8
-0-10-8
0-10-8
0-3-8
0-3-8
6-9-0
6-5-8
7-0-8
0-3-8
2-0-09-0-83-5-05-7-812.0012
10.0012
Plate Offsets (X,Y)-- [5:0-4-8,0-1-12]
LOADING (psf)
TCLL (roof)
Snow (Pf/Pg)
TCDL
BCLL
BCDL
20.0
23.1/30.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.16
0.41
0.09
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.15
-0.29
-0.00
-0.00
(loc)
5-6
5-6
5
3
l/defl
>549
>275
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 41 lb FT = 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 SPF 1650F 1.5E
WEBS 2x4 SPF Stud *Except*
WCL2: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size)6=372/0-3-8 (min. 0-1-8), 5=332/Mechanical
Max Horz6=178(LC 11)
Max Uplift5=-74(LC 11)
Max Grav6=372(LC 1), 5=377(LC 20)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-7=-496/89, 3-7=-404/107, 2-6=-305/149
BOT CHORD 5-6=-424/406, 3-5=-338/176
WEBS 2-5=0/340
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II;
Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 6-10-12 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=30.0 psf (ground snow); Pf=23.1 psf (flat roof
snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 23.1 psf on overhangs
non-concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
04/08/19
Mike Sheeks
DE Job # 64859-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, National Design Standard for Metal Plate Connected Wood Truss Construction and
TPI/WTCA BCSI-06, Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses for additional information.
Job
1903478-12T
Truss
T03
Truss Type
Scissor
Qty
2
Ply
1
Job Reference (optional)
Run: 81.200 s 20 Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Tue Mar 19 10:55:43 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock
ID:cuIsLoyFj7kP14Z2?6kwvszbiAi-aMf1ZQo2IJWRTMHJDOoMBUoAM0rJhXE1rtLsfvzZPME
Scale = 1:34.2
T1 T2
B1 B2
W1
EV1
WCL2
EV2
WCR2
1
2
3
6
5
4
3x6
4x4
3x6
1.5x4
1.5x4
6x8
0-3-8
0-3-8
2-2-12
1-11-4
4-2-0
1-11-4
4-5-8
0-3-8
0-3-8
0-3-8
2-2-12
1-11-4
4-2-0
1-11-4
4-5-8
0-3-8
3-11-13
6-2-96-4-40-1-11
3-11-13
1-8-1012.0012
10.0012
LOADING (psf)
TCLL (roof)
Snow (Pf/Pg)
TCDL
BCLL
BCDL
20.0
23.1/30.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.18
0.05
0.05
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.00
0.00
0.00
(loc)
5-6
5-6
4
5
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 34 lb FT = 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-5-8 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size)6=180/Mechanical, 4=180/Mechanical
Max Horz6=-132(LC 12)
Max Uplift6=-36(LC 10), 4=-36(LC 11)
Max Grav6=214(LC 20), 4=214(LC 19)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II;
Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=30.0 psf (ground snow); Pf=23.1 psf (flat roof
snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 4.
8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
04/08/19
Mike Sheeks