Loading...
HomeMy WebLinkAboutMuchnik_Sheets 92 Sunrise Manufactured Truss PackageNAILING SCHEDULE 2X4 LEDGER USED AS TRUSS BEARING 480 PLF MAXIMUM 3-1/2" NOTE: SEE TRUSS DRAWINGS FOR REACTIONS 160 PLF MAXIMUM 2-ROWS 16D BOX NAILS STAGGERED AT 16" O.C. SPACING (MAX) 16" O.C.4" O.C. 3-1/2" 2-ROWS 16D BOX NAILS STAGGERED AT 4" O.C. SPACING (MAX)LG1 BBO1 BBO2DB2GE01GE02T02T02 GE03GE04T05T05T07T07T0 9V01V02V03V04 V05 V06 V07 V08 V09 V10 V11 V12 V13 V14 V15 V04 V05 V06 V07 V08 V09 V10 V11 V12 V13 V14 V15 P01T01(7) T03(6) T04(4) T06(6) P02(10)T08(9)6' 9" 22' 7"29' 4"19' 3" 10' 1"29' 4"1' 6" 19' 1" 19' 7" 12' 11" 16' 7" 8' 2" 77' 10" 20' 5 1/4" 49' 2 3/4" 8' 2" 77' 10" 30' 9 1/2" 18' 4 1/2" 28' 8"1' 6"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"1' 2"2' 0"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 7 1/16"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0"6' 2 1/2"18' 9 1/2"F7GE05 T10 T11 GE05 T10 T11 T12(10)2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 1' 2 1/2"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0"1317 N. Owen Street Rensselaer, IN 47978 1-800-866-7658 Designer: mbbraddock JOBNAME: CUSTOMERNAME: Old Town Design Group Muchnik - Sheets Residence Contract Lumber Brownsburg, IN JOB#: 1903387-12T DATE: 3/12/2019 JOBNOTES: Please see the notes on this drawing for more information. Beams are by others. Trusses are 24" on center except as shown on this drawing. Piggy-back trusses require 24" on center purlins. General Notes: THIS IS A TRUSS PLACEMENT DIAGRAM ONLY. These trusses are designed as individual building components to be incorporated into the building design at the specification of the Building Designer whose responsibilities include; the design and bracing of the overall structure, any supporting structure including the walls, headers, beams and columns and the permanent bracing of the roof and floor system. The General Contractor and/or their agents are responsible for; the verification of all dimensions, assuring that any conventional framing shall uniformly transfer the loads to the trusses below, the temporary bracing of the truss system as well as the permanent web bracing shown on the individual truss drawing sheets for the truss designs identified on this placement plan. For general guidance regarding bracing, consult "Bracing of Wood Trusses" available from the Truss Plate Institute 583 D'Onofrio Drive, Madison, WI 53179. COMPANY, INC. STARK TRUSS Dansco Engineering, LLC P.O. Box 3400 Apollo Beach, FL 33572 This truss placement diagram (TPD) has been prepared by component manufacturer technician(s) and reviewed by DANSCO Engineering, LLC for the design criteria shown on this TPD. DE accepts responsibility for specifying truss-to-truss connections within the truss system only. DE is not responsible for the design of this structure, for specifying permanent truss bracing, for specifying the attachment of the trusses and bracing to the structure, nor for specifying the diaphragm or sheathing (including attachment to the trusses) - these items are the responsibility of the design professional of record (engineer or architect of record). Review and approval of the design criteria shown is the responsibility of the design professional of record. The contractor shall be responsible for field verification of all dimensions, for means and methods of construction, for temporary bracing of the trusses, and for coordination of the work of all trades. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering, LLC P.O. Box 3400 Apollo Beach, FL 33572 Date: 3/28/19 DE Job# 65028-W1 04/08/19 Mike Sheeks DE DANSCO ENGINEERING, LLC P.O. Box 3400 Apollo Beach, FL 33572 Telephone (813) 645-0166 Facsimile (813) 645-9698 The truss drawing(s) attached have been prepared by Dansco Engineering, LLC under my direct supervision and control based on the parameters provided by Stark Truss Inc. Job: 1903387-12T 34 truss design(s) 65028-W1 3/28/19 Samuel A. Greenberg, P.E. Indiana Reg. #19700485 Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length is the distance from the top chord to bottom chord. The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI 1-2014 Chapter 2. Warning !—Verify design parameters and read notes before use. These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate Institute, 583 D’Onofrio Drive, Madison, WI 53719 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss GE01 Truss Type Common Supported Gable Qty 1 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:15 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-m4ZVwmkJAQVSDSAQrAVdspyc02l4GdXDl0iyhxzWS_g Scale = 1:69.6 T1 T2 B1 ST1 ST2 ST3 ST4 ST5ST6 ST7 ST8 ST9 ST10 ST11 B2 HW1 HW2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 27 26 25 2423 22 21 20 19 18 17 16 4x4 3x5 3x6 4x8 4x8 3x5 22-7-0 22-7-0 -0-10-8 0-10-8 11-3-8 11-3-8 22-3-8 11-0-0 22-7-0 0-3-8 23-5-8 0-10-8 0-8-68-2-12 8-5-90-8-68.0012 Plate Offsets (X,Y)-- [2:0-2-4,0-0-2], [14:0-2-4,0-2-2] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.04 0.03 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 14 15 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 115 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud *Except* ST1: 2x4 HF/SPF No.2 SLIDER Left 2x4 SPF Stud 1-4-15, Right 2x4 SPF Stud 1-4-15 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 22-7-0. (lb) - Max Horz2=127(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 2, 22, 23, 25, 26, 27, 20, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 2, 21, 22, 23, 25, 26, 27, 20, 19, 18, 17, 16, 14 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Corner(3) -0-10-8 to 2-1-8, Exterior(2) 2-1-8 to 11-3-8, Corner(3) 11-3-8 to 14-3-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 22, 23, 25, 26, 27, 20, 19, 18, 17, 16. 12) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2, 14. 13) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss GE02 Truss Type GABLE Qty 1 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:17 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-iShFKRmZh1lASmKpzbX5xE2omsKIkR8WCKB3mqzWS_e Scale = 1:67.1 T1 T2 B1 W1 W2 W3W4 W5HW1 HW2 T3 T4 B2 W6 W7 W8 ST1 ST4ST6 ST7 ST9 ST10 ST11 W9 1 2 3 4 5 6 7 8 9 10 11 12 17 16 15 14 13 18 19 32 33 34 35 4x6 3x6 3x4 3x4 3x4 3x6 3x8 3x5 1.5x4 3x5 1.5x4 4x4 3x4 3x4 1.5x4 3x6 3x6 5x6 3x6 1.5x4 6-10-12 6-10-12 14-8-0 7-9-4 22-5-4 7-9-4 29-4-0 6-10-12 -0-10-8 0-10-8 6-10-12 6-10-12 14-8-0 7-9-4 22-5-4 7-9-4 29-0-8 6-7-4 29-4-0 0-3-8 30-2-8 0-10-8 0-8-610-5-12 10-8-9 0-8-68.0012 Plate Offsets (X,Y)-- [5:0-3-0,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.67 0.49 0.51 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.06 -0.14 0.03 0.02 (loc) 13-14 13-14 11 11-13 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 167 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud *Except* W1,W2,W4: 2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud SLIDER Left 2x4 SPF Stud 4-1-1, Right 2x4 SPF Stud 4-1-1 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 9-14 JOINTS 1 Brace at Jt(s): 18, 19 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)2=293/0-3-8 (min. 0-1-8), 16=1033/0-3-8 (min. 0-1-15), 11=840/0-3-8 (min. 0-1-9) Max Horz2=-166(LC 12) Max Uplift2=-54(LC 14), 11=-15(LC 14) Max Grav2=363(LC 28), 16=1160(LC 2), 11=953(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-617/71, 5-34=-472/75, 6-34=-458/98, 6-7=-513/119, 7-8=-601/116, 8-9=-728/89, 9-10=-1098/61, 10-35=-1160/34, 11-35=-1216/28 BOT CHORD 13-14=0/914, 11-13=0/914 WEBS 14-18=-20/307, 6-18=-20/307, 9-14=-458/58, 9-13=0/311, 4-19=0/375, 14-19=0/373, 16-32=-966/24, 4-32=-901/19 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 14-8-0, Exterior(2) 14-8-0 to 17-10-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11. 11) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss GE03 Truss Type Common Supported Gable Qty 1 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:18 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-AfFdYnnCSLt14vv?XI2KTSa6bGnYT?gfR_xdIGzWS_d Scale = 1:34.7 EV1 T1 T2 EV2 B1 ST1 ST2 ST3 ST4 ST5 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 4x4 10-1-0 10-1-0 -0-10-8 0-10-8 5-0-8 5-0-8 9-9-8 4-9-0 10-1-0 0-3-8 10-11-8 0-10-8 1-0-60-1-14 6-0-14 6-3-15 1-0-60-1-14 12.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.09 0.04 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 9 9 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 51 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 10-1-0. (lb) - Max Horz16=125(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 16, 10, 14, 15, 12, 11 Max Grav All reactions 250 lb or less at joint(s) 16, 10, 13, 14, 15, 12, 11 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Corner(3) -0-10-8 to 2-1-8, Exterior(2) 2-1-8 to 5-0-8, Corner(3) 5-0-8 to 8-0-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Bearing at joint(s) 16, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10, 14, 15, 12, 11. 14) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss GE04 Truss Type Piggyback Base Structural Gable Gable l l Gable l Gable Qty 1 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:20 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-61NOzToS_y7lJD3Oej5oZtgM83HXxu9yuIQjN9zWS_b Scale = 1:68.8 T1 T2 T3 B1 W1 W2 W3 W4 W5 W6 EV1 WCL2 EV2 WCR2 W7 W8 W9 W10 W11 W13 ST1 ST3 ST4 ST6 ST9 ST12 ST14 ST15 ST17 ST18 ST20 ST23 ST26 B2 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 19 20 21 22 23 2418 17 45 46 47 4849 50 51 52 53 54 4x6 4x4 3x6 4x4 3x8 3x4 3x4 3x8 4x4 3x4 3x4 3x8 3x4 1.5x4 1.5x4 1.5x4 3x8 3x6 3x8 3x6 3x6 3x8 1.5x4 0-3-10 0-3-10 9-11-10 9-8-0 19-4-6 9-4-13 19-6-8 0-2-2 29-4-0 9-9-8 -0-10-8 0-10-8 4-9-15 4-9-15 9-11-10 5-1-11 14-8-0 4-8-6 19-4-6 4-8-6 24-6-1 5-1-11 29-0-8 4-6-7 29-4-0 0-3-8 30-2-8 0-10-8 1-0-611-0-0 11-3-1 1-0-611-0-0 12.0012 Plate Offsets (X,Y)-- [4:0-4-4,0-1-12], [5:0-1-12,0-1-8], [6:0-2-4,0-1-12], [19:0-3-0,0-2-10], [34:0-1-8,0-1-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 20.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.47 0.71 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.27 -0.50 0.01 0.00 (loc) 11-12 11-12 11 11-12 l/defl >450 >241 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 252 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud *Except* W1,W2,W3,W4,W5,W6: 2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 17, 18, 19, 20, 21, 22, 23 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 18-11-4 except (jt=length) 16=0-3-8, 16=0-3-8, 16=0-3-8, 11=0-3-8. (lb) - Max Horz16=218(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 16, 11 Max Grav All reactions 250 lb or less at joint(s) 15 except 14=752(LC 28), 12=775(LC 29), 12=725(LC 1), 16=395(LC 28), 16=345(LC 1), 16=345(LC 1), 11=470(LC 25) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 8-52=-294/99, 9-52=-427/77, 2-16=-269/143, 9-11=-427/120 WEBS 3-19=-265/160, 14-19=-260/156, 14-20=-274/13, 4-20=-274/13, 12-23=-270/13, 6-23=-255/0, 12-24=-255/138 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 9-11-10, Exterior(2) 9-11-10 to 23-7-5, Interior(1) 23-7-5 to 30-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 2x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 11. 12) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Continued on page 2 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss GE04 Truss Type Piggyback Base Structural Gable Gable l l Gable l Gable Qty 1 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:20 2019 Page 2Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-61NOzToS_y7lJD3Oej5oZtgM83HXxu9yuIQjN9zWS_b NOTES- 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss GE05 Truss Type GABLE Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:22 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-3QU8O9qiWZNTYXDmm87GeIlpIt8kOqwFMcvqR1zWS_Z Scale = 1:30.7 EV1 T1 T2 T3 EV2 B1 ST2 ST3 ST4 ST5 ST6 ST7 ST8 ST9 ST10 B2 1 2 3 4 5 6 7 8 9 10 11 12 13 25 24 23 22 21 20 19 18 17 16 15 14 26 27 3x6 3x6 3x6 18-4-8 18-4-8 2-8-15 2-8-15 15-7-9 12-10-11 18-1-0 2-5-7 18-4-8 0-3-8 1-2-02-9-13 2-11-15 1-2-02-9-13 8.0012 Plate Offsets (X,Y)-- [3:0-3-0,Edge], [11:0-3-0,Edge], [23:0-1-8,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 20.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.04 0.02 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 14 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 67 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-11. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 18-4-8. (lb) - Max Horz25=50(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 25, 14, 19, 20, 21, 24, 18, 17, 15 Max Grav All reactions 250 lb or less at joint(s) 25, 14, 19, 20, 21, 22, 24, 18, 17, 16, 15 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Corner(3) 0-1-12 to 5-8-15, Exterior(2) 5-8-15 to 15-7-9, Corner(3) 15-7-9 to 18-2-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 14, 19, 20, 21, 24, 18, 17, 15. 13) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss P01 Truss Type GABLE Qty 1 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:23 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-Xc2WbVrKHtVJAhozJseVAVIw6HUd7HfOaGeOzUzWS_Y Scale = 1:30.0 T1 T2 B1 ST1 ST2 ST3 1 2 3 45 8 7 6 11 12 13 14 4x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 9-4-13 9-4-13 4-8-6 4-8-6 9-1-5 4-4-14 9-4-13 0-3-8 0-5-34-6-12 0-1-10 4-8-20-5-30-1-10 12.0012 Plate Offsets (X,Y)-- [2:0-2-6,0-1-0], [4:0-2-6,0-1-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.29 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 0.02 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 8-3-2. (lb) - Max Horz2=78(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 2, 4 Max Grav All reactions 250 lb or less at joint(s) 7, 8, 6 except 2=285(LC 2), 4=285(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-2-14 to 3-2-14, Interior(1) 3-2-14 to 4-8-6, Exterior(2) 4-8-6 to 7-8-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 11) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss P02 Truss Type Piggyback Qty 10 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:24 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-?ocuprry2BdAoqM9tZ9kjjq5thoFskxYpwOxWwzWS_X Scale = 1:30.0 T1 T2 B1 ST1 1 2 3 45 6 7 8 9 10 4x4 2x4 2x4 1.5x4 9-4-13 9-4-13 4-8-6 4-8-6 9-1-5 4-4-14 9-4-13 0-3-8 0-5-34-6-12 0-1-10 4-8-20-5-30-1-10 12.0012 Plate Offsets (X,Y)-- [2:0-2-6,0-1-0], [4:0-2-6,0-1-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.29 0.15 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 0.02 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)2=192/8-3-2 (min. 0-1-8), 4=192/8-3-2 (min. 0-1-8), 6=235/8-3-2 (min. 0-1-8) Max Horz2=-78(LC 12) Max Uplift2=-28(LC 14), 4=-28(LC 14) Max Grav2=221(LC 2), 4=221(LC 2), 6=259(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-2-14 to 3-2-14, Interior(1) 3-2-14 to 4-8-6, Exterior(2) 4-8-6 to 7-8-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T01 Truss Type Common Qty 7 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:25 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-T?AH0BsbpUm1P_xLRHhzGwNAh439b2zh2a7U2MzWS_W Scale = 1:67.1 T1 T2 B1 W1 W2 W3W4 W5 HW1 HW2 T3 T4 B2 1 2 3 4 5 6 7 8 9 10 11 15 14 13 12 16 17 18 19 3x8 4x6 3x8 3x6 3x4 3x4 3x6 3x8 3x5 1.5x4 3x5 1.5x4 3x6 3x4 3x4 6-10-12 6-10-12 14-8-0 7-9-4 22-5-4 7-9-4 29-4-0 6-10-12 -0-10-8 0-10-8 6-10-12 6-10-12 14-8-0 7-9-4 22-5-4 7-9-4 29-0-8 6-7-4 29-4-0 0-3-8 30-2-8 0-10-8 0-8-610-5-12 10-8-9 0-8-68.0012 Plate Offsets (X,Y)-- [2:0-3-7,0-1-2], [10:0-3-7,0-1-2] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.67 0.49 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.07 -0.14 0.03 0.02 (loc) 12-13 12-13 10 12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 130 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 *Except* W3,W5: 2x4 SPF Stud SLIDER Left 2x4 SPF Stud 4-1-1, Right 2x4 SPF Stud 4-1-1 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 8-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)2=297/0-3-8 (min. 0-1-8), 15=1027/0-3-8 (min. 0-1-14), 10=841/0-3-8 (min. 0-1-9) Max Horz2=-166(LC 12) Max Uplift2=-54(LC 14), 10=-16(LC 14) Max Grav2=362(LC 28), 15=1153(LC 2), 10=955(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-717/109, 5-17=-577/111, 6-17=-559/135, 6-18=-555/133, 7-18=-577/109, 7-8=-714/107, 8-9=-1043/66, 9-19=-1181/37, 10-19=-1234/33 BOT CHORD 12-13=0/939, 10-12=0/939 WEBS 6-13=-24/311, 8-13=-562/90, 8-12=0/309, 4-13=0/453, 4-15=-986/44 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 14-8-0, Exterior(2) 14-8-0 to 17-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T02 Truss Type Common Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:26 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-xBkfDWtDaouu18WX?_CCo8wLOUOPKVGrHEt2apzWS_V Scale = 1:65.0 T1 T2 B1 W1 W2 W3W4 W5 HW1 HW2 T3 T4 B2 1 2 3 4 5 6 7 8 9 13 12 11 10 14 153x8 4x6 3x8 3x5 3x4 3x4 3x6 3x8 3x5 1.5x4 3x5 1.5x4 3x5 3x4 3x4 6-10-12 6-10-12 14-8-0 7-9-4 22-5-4 7-9-4 29-4-0 6-10-12 6-10-12 6-10-12 14-8-0 7-9-4 22-5-4 7-9-4 29-0-8 6-7-4 29-4-0 0-3-8 0-8-610-5-12 0-8-68.0012 Plate Offsets (X,Y)-- [1:0-2-15,0-0-6], [9:0-2-15,0-0-6] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.67 0.49 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.06 -0.14 0.03 0.02 (loc) 10-11 10-11 9 9-10 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 128 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 *Except* W3,W5: 2x4 SPF Stud SLIDER Left 2x4 SPF Stud 4-1-1, Right 2x4 SPF Stud 4-1-1 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 7-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=256/0-3-8 (min. 0-1-8), 13=1023/0-3-8 (min. 0-1-14), 9=798/0-3-8 (min. 0-1-8) Max Horz1=-163(LC 12) Max Uplift1=-36(LC 14) Max Grav1=313(LC 27), 13=1147(LC 2), 9=904(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-722/110, 4-14=-581/118, 5-14=-564/141, 5-15=-560/137, 6-15=-581/113, 6-7=-719/101, 7-8=-1051/72, 8-9=-1241/42 BOT CHORD 10-11=0/947, 9-10=0/947 WEBS 5-11=-31/311, 7-11=-566/92, 7-10=0/311, 3-11=0/450, 3-13=-980/42 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 14-8-0, Exterior(2) 14-8-0 to 17-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T03 Truss Type Common Qty 6 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:27 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-PNI1RsurL60lfI5kYhjRLLSW5uc830G_Vucb7FzWS_U Scale = 1:61.5 T1 T2 B1 W1 W2 W3 W4 HW1 HW2 T3 T4 B2 1 2 3 4 5 6 7 8 9 12 11 10 13 14 15 16 17 18 19 20 21 22 3x6 4x6 3x6 3x8 3x4 3x4 3x6 3x4 1.5x4 3x4 1.5x4 3x8 3x4 3x4 9-10-8 9-10-8 19-5-8 9-7-0 29-4-0 9-10-8 7-5-12 7-5-12 14-8-0 7-2-4 21-10-4 7-2-4 29-0-8 7-2-4 29-4-0 0-3-8 0-8-610-5-12 0-8-68.0012 Plate Offsets (X,Y)-- [1:0-4-3,Edge], [9:0-4-3,Edge] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.68 0.97 0.28 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.30 -0.52 0.06 0.03 (loc) 10-12 1-12 9 9-10 l/defl >999 >676 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 124 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 *Except* W2,W4: 2x4 SPF Stud SLIDER Left 2x4 SPF Stud 4-5-7, Right 2x4 SPF Stud 4-5-7 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=1038/0-3-8 (min. 0-2-0), 9=1038/0-3-8 (min. 0-2-0) Max Horz1=163(LC 13) Max Grav1=1229(LC 23), 9=1229(LC 24) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-13=-1717/40, 2-13=-1648/40, 2-3=-1547/71, 3-4=-1582/100, 4-14=-1473/122, 5-14=-1464/143, 5-15=-1464/143, 6-15=-1473/122, 6-7=-1582/100, 7-8=-1547/71, 8-16=-1648/40, 9-16=-1717/40 BOT CHORD 1-17=0/1449, 17-18=0/1449, 12-18=0/1449, 12-19=0/969, 11-19=0/969, 11-20=0/969, 10-20=0/969, 10-21=0/1337, 21-22=0/1337, 9-22=0/1337 WEBS 5-10=-24/769, 7-10=-385/158, 5-12=-24/769, 3-12=-385/158 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 14-8-0, Exterior(2) 14-8-0 to 17-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T04 Truss Type Common Qty 4 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:28 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-tasPeCuT6P8cGSgw6PEgtZ?mII9aoWg7kYM8fhzWS_T Scale = 1:38.2 T1 T2 B1 W1 EV1 WCL2 EV2WCR2 1 2 3 4 7 6 5 8 9 10 5x6 4x4 4x8 5x6 1.5x4 1.5x4 5-0-8 5-0-8 10-1-0 5-0-8 5-0-8 5-0-8 9-9-8 4-9-0 10-1-0 0-3-8 10-11-8 0-10-8 1-0-66-0-14 6-3-15 1-0-60-1-14 12.0012 Plate Offsets (X,Y)-- [1:0-2-12,0-1-8], [3:0-2-12,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.33 0.19 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.03 0.00 0.00 (loc) 6-7 6-7 5 6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 49 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)7=344/0-3-8 (min. 0-1-8), 5=401/0-3-8 (min. 0-1-8) Max Horz7=-119(LC 12) Max Uplift5=-16(LC 14) Max Grav7=388(LC 2), 5=456(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-366/35, 8-9=-263/39, 2-10=-263/65, 3-10=-374/39, 1-7=-345/56, 3-5=-412/89 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 5-0-8, Exterior(2) 5-0-8 to 8-0-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 7, 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5. 9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T05 Truss Type Piggyback Base Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:29 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-MmQnsYv5tjGTucF6g6lvQmXuxiKTXw9HzC5iB7zWS_S Scale: 3/16"=1' T1 T2 T3 B1 W1 W2 W3 W4 W5 W6 EV1 WCL2 EV2 WCR2 B2 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 17 1819 20 21 22 23 24 25 26 27 28 4x6 4x6 3x6 3x8 4x4 3x4 3x8 4x4 3x4 3x8 3x8 3x4 9-11-10 9-11-10 19-4-6 9-4-13 29-4-0 9-11-10 -0-10-8 0-10-8 5-0-2 5-0-2 9-11-10 4-11-7 14-8-0 4-8-6 19-4-6 4-8-6 24-3-14 4-11-7 29-0-8 4-8-10 29-4-0 0-3-8 30-2-8 0-10-8 1-0-611-0-0 11-3-1 1-0-611-0-0 12.0012 Plate Offsets (X,Y)-- [4:0-4-4,0-1-12], [6:0-4-4,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 20.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.53 0.85 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.26 -0.52 0.04 0.02 (loc) 13-14 13-14 10 11-13 l/defl >999 >670 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 167 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 *Except* EV1,WCL2,EV2,WCR2: 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-7 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-13, 5-11, 3-14, 7-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)14=1127/0-3-8 (min. 0-2-2), 10=1127/0-3-8 (min. 0-2-2) Max Horz14=218(LC 13) Max Uplift14=-2(LC 14), 10=-2(LC 14) Max Grav14=1279(LC 24), 10=1279(LC 25) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-527/78, 3-15=-375/101, 3-16=-1210/118, 4-16=-1113/157, 4-17=-811/158, 17-18=-810/158, 5-18=-810/158, 5-19=-810/158, 19-20=-811/158, 6-20=-811/158, 6-21=-1113/157, 7-21=-1210/118, 7-22=-375/101, 8-22=-526/78, 2-14=-505/122, 8-10=-505/122 BOT CHORD 14-23=0/992, 23-24=0/992, 13-24=0/992, 13-25=0/909, 12-25=0/909, 12-26=0/909, 11-26=0/909, 11-27=0/871, 27-28=0/871, 10-28=0/871 WEBS 4-13=-25/557, 6-11=-25/557, 3-14=-927/17, 7-10=-926/17 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 9-11-10, Exterior(2) 9-11-10 to 23-7-5, Interior(1) 23-7-5 to 30-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 10. 9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T06 Truss Type Piggyback Base Qty 6 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:31 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-I9XYHExLOKWB7vPVnXnNVBdDKV0w?poaQWapG0zWS_Q Scale = 1:62.5 T1 T2 T3 B1 W1 W2 W3 W4 W5 W6 EV1 WCL2 EV2 WCR2 B2 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 161718 19 20 21 22 23 24 25 26 27 3x4 4x6 4x6 3x4 4x6 3x8 4x4 3x4 3x8 4x4 3x8 3x8 9-11-10 9-11-10 19-4-6 9-4-13 29-4-0 9-11-10 5-0-2 5-0-2 9-11-10 4-11-7 14-8-0 4-8-6 19-4-6 4-8-6 24-3-14 4-11-7 29-0-8 4-8-10 29-4-0 0-3-8 1-0-611-0-0 1-0-611-0-0 12.0012 Plate Offsets (X,Y)-- [3:0-4-4,0-1-12], [5:0-4-4,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 20.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.53 0.85 0.37 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.25 -0.41 0.04 0.10 (loc) 9-11 9-11 8 9-11 l/defl >999 >846 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 163 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 SPF 1650F 1.5E WEBS 2x4 HF/SPF No.2 *Except* EV1,WCL2,EV2,WCR2: 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-1 oc purlins, except end verticals, and 2-0-0 oc purlins (5-11-14 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-11, 4-9, 2-12, 6-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)12=1134/0-3-8 (min. 0-2-0), 8=1131/0-3-8 (min. 0-2-0) Max Horz12=200(LC 13) Max Grav12=1275(LC 23), 8=1273(LC 24) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-13=-447/44, 2-13=-301/67, 2-14=-1297/130, 3-14=-1199/168, 3-15=-872/164, 15-16=-871/164, 4-16=-871/164, 4-17=-868/164, 17-18=-869/164, 5-18=-870/164, 5-19=-1195/168, 6-19=-1294/129, 6-20=-303/67, 7-20=-448/44, 1-12=-386/64, 7-8=-387/64 BOT CHORD 12-21=-30/1042, 21-22=-30/1042, 11-22=-30/1042, 11-23=0/959, 10-23=0/959, 10-24=0/959, 24-25=0/959, 9-25=0/959, 9-26=-19/917, 26-27=-19/917, 8-27=-19/917 WEBS 3-11=-35/619, 5-9=-35/616, 2-12=-1075/59, 6-8=-1069/58 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 9-11-10, Exterior(2) 9-11-10 to 23-7-5, Interior(1) 23-7-5 to 29-2-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 119 lb down and 10 lb up at 14-4-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Continued on page 2 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T06 Truss Type Piggyback Base Qty 6 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:31 2019 Page 2Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-I9XYHExLOKWB7vPVnXnNVBdDKV0w?poaQWapG0zWS_Q LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-51, 3-5=-61, 5-7=-51, 8-12=-20 Concentrated Loads (lb) Vert: 24=-115(F) 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T07 Truss Type Piggyback Base Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:32 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-mL5wUay_9ee2l3_hLFJc2O9OvvMLkDEjfAKMoSzWS_P Scale = 1:66.1 T1 T2 T3 B1 B2 B3 B4 B5 W1 W2 W3 W4 W5 W6 W7 W8 W9 EV1 WCL2 EV2 WCR2W10 1 2 34 5 6 7 8 17 16 15 14 13 12 11 10 9 18 19 20 21 22 23 24 25 26 3x8 6x6 6x6 2x4 1.5x4 1.5x4 3x4 5x8 1.5x4 1.5x4 3x6 4x4 3x8 4x12 3x8 4x4 3x8 5-0-2 5-0-2 9-11-10 4-11-7 10-6-0 0-6-6 10-9-8 0-3-8 14-3-8 3-6-0 19-4-6 5-0-14 29-4-0 9-11-10 5-0-2 5-0-2 9-11-10 4-11-7 10-9-8 0-9-14 14-3-8 3-6-0 19-4-6 5-0-14 24-3-14 4-11-7 29-0-8 4-8-10 29-4-0 0-3-8 1-0-611-0-0 1-0-63-0-011-0-0 12.0012 Plate Offsets (X,Y)-- [1:0-3-7,Edge], [3:0-4-4,0-1-12], [6:0-4-4,0-1-12], [12:0-2-8,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 20.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.54 0.78 0.55 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.26 -0.50 0.01 0.01 (loc) 9-10 9-10 9 10 l/defl >867 >449 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 203 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 *Except* W1,W6,EV1,WCL2,EV2,WCR2,W10: 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-6. BOT CHORD Rigid ceiling directly applied or 5-2-3 oc bracing. Except: 1 Row at midpt 4-13, 5-12 WEBS 1 Row at midpt 6-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)17=398/0-3-8 (min. 0-1-8), 14=1152/0-3-8 (min. 0-2-0), 9=715/0-3-8 (min. 0-1-8) Max Horz17=-200(LC 12) Max Uplift17=-84(LC 14), 9=-38(LC 14) Max Grav17=466(LC 24), 14=1209(LC 2), 9=826(LC 24) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-18=-483/161, 2-18=-395/185, 2-19=-358/245, 3-19=-319/283, 3-4=-259/233, 4-20=-457/220, 5-20=-457/220, 5-21=-457/220, 21-22=-457/220, 6-22=-458/220, 6-23=-601/220, 7-23=-701/181, 7-24=-303/74, 8-24=-455/51, 1-17=-422/152, 8-9=-389/69 BOT CHORD 15-16=-49/298, 13-14=-1190/0, 4-13=-758/0, 5-12=-301/74, 10-25=-40/508, 25-26=-40/508, 9-26=-40/508 WEBS 2-15=-331/112, 4-12=0/767, 10-12=0/446, 7-9=-505/106, 13-15=-5/316 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 9-11-10, Exterior(2) 9-11-10 to 23-7-5, Interior(1) 23-7-5 to 29-2-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 9. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 119 lb down and 10 lb up at 14-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Continued on page 2 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T07 Truss Type Piggyback Base Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:32 2019 Page 2Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-mL5wUay_9ee2l3_hLFJc2O9OvvMLkDEjfAKMoSzWS_P NOTES- 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-51, 3-6=-61, 6-8=-51, 14-17=-20, 12-13=-20, 9-11=-20 Concentrated Loads (lb) Vert: 12=-115(F) 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T08 Truss Type MONOPITCH Qty 9 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:33 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-EXfIhwycwymvNDYuvyqraciY4JoNTmzsuq3vKvzWS_O Scale = 1:22.8 T1 EV2 B1WCR3 WCR2 1 2 3 5 4 6 7 8 4x4 4x8 1.5x4 6-4-0 6-4-0 -1-2-8 1-2-8 6-0-8 6-0-8 6-4-0 0-3-8 0-8-63-10-6 4-1-33-6-14 0-3-83-10-6 6.0012 Plate Offsets (X,Y)-- [2:0-0-0,0-1-15], [2:0-4-13,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.58 0.40 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.17 0.00 0.00 (loc) 4-5 4-5 5 l/defl >842 >421 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 29 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)5=290/0-3-0 (min. 0-1-8), 4=206/0-1-8 (min. 0-1-8) Max Horz5=91(LC 16) Max Uplift5=-6(LC 16), 4=-15(LC 16) Max Grav5=332(LC 2), 4=233(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-272/177 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 6-2-4 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 5, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T09 Truss Type Monopitch Qty 1 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:34 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-ikDgvGzEhFum_N74TgL47pFknjATCDA06UpTsLzWS_N Scale = 1:23.5 T1 EV2 B1 WCL1 EV1 1 2 3 5 4 6 7 4x4 3x4 1.5x4 2x4 0-3-6 0-2-10 5-5-3 5-1-13 -2-8-7 2-8-7 5-1-11 5-1-11 5-5-3 0-3-8 1-4-63-9-93-11-8 3-6-10-3-83-9-95.3712 Plate Offsets (X,Y)-- [4:Edge,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.52 0.29 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.05 -0.09 0.00 0.00 (loc) 4-5 4-5 4 5 l/defl >999 >683 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 28 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)5=367/0-5-3 (min. 0-1-8), 4=142/0-1-8 (min. 0-1-8) Max Horz5=106(LC 13) Max Uplift5=-68(LC 16), 4=-12(LC 13) Max Grav5=424(LC 2), 4=161(LC 21) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-372/233 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) -2-8-7 to 0-1-12, Interior(1) 0-1-12 to 5-3-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T10 Truss Type Hip Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:35 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-Awn36b_sSZ0ccXiG0NsJg1ntt6VBxf09L8Y0PnzWS_M Scale = 1:32.9 T1 T2 T3 B1 W1 W2 W3 EV1 WCL2 EV2 WCR2 B2 1 2 3 4 9 8 7 6 5 10 11 12 13 14 15 4x4 6x6 5x6 4x4 1.5x4 3x64x4 4x8 1.5x4 5-8-14 5-8-14 12-7-10 6-10-11 18-4-8 5-8-14 5-8-14 5-8-14 12-7-10 6-10-11 18-1-0 5-5-6 18-4-8 0-3-8 1-2-04-9-13 4-11-15 1-2-04-9-13 8.0012 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [4:Edge,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 20.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.69 0.38 0.23 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.06 -0.12 0.01 0.01 (loc) 6-8 6-8 5 6-8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 79 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud *Except* W2: 2x4 HF/SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-3 oc purlins, except end verticals, and 2-0-0 oc purlins (5-1-3 max.): 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-6 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)9=675/0-3-8 (min. 0-1-8), 5=675/0-3-8 (min. 0-1-8) Max Horz9=-81(LC 12) Max Grav9=723(LC 2), 5=723(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-866/38, 10-11=-779/47, 2-11=-768/66, 2-12=-651/93, 12-13=-651/93, 3-13=-651/93, 3-14=-768/66, 14-15=-779/46, 4-15=-866/38, 1-9=-677/63, 4-5=-677/63 BOT CHORD 7-8=-12/651, 6-7=-12/651 WEBS 1-8=0/538, 4-6=0/538 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 5-8-14, Exterior(2) 5-8-14 to 16-10-8, Interior(1) 16-10-8 to 18-2-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T11 Truss Type Hip Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:36 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-e6LRKx?UDt8TEgHSa4NYCEK7iWocg3RJanIaxEzWS_L Scale = 1:40.5 T1 T2 T3 B1 W1 W2 W3 W4 W5 EV1 WCL2 EV2 WCR2 B2 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 2x4 5x6 6x6 2x4 3x6 3x8 4x4 3x4 4x4 3x6 3x6 8-8-14 8-8-14 9-7-10 0-10-11 18-4-8 8-8-14 4-1-11 4-1-11 8-8-14 4-7-3 9-7-10 0-10-11 14-2-13 4-7-3 18-1-0 3-10-3 18-4-8 0-3-8 1-2-06-9-13 6-11-15 1-2-06-9-13 8.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 20.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.36 0.56 0.41 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.13 -0.27 0.02 0.01 (loc) 7-8 7-8 7 8 l/defl >999 >799 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 95 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)11=645/0-3-8 (min. 0-1-8), 7=645/0-3-8 (min. 0-1-8) Max Horz11=112(LC 13) Max Grav11=723(LC 2), 7=723(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-13=-710/51, 3-13=-697/82, 3-4=-523/91, 4-14=-697/80, 5-14=-709/50 BOT CHORD 10-11=-42/631, 9-10=-42/631, 8-9=0/525, 7-8=-33/631 WEBS 2-11=-700/67, 5-7=-699/66 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 8-8-14, Exterior(2) 8-8-14 to 9-7-10, Interior(1) 13-10-8 to 18-2-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss T12 Truss Type Common Qty 10 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:36 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-e6LRKx?UDt8TEgHSa4NYCEK7fWmSg2CJanIaxEzWS_L Scale = 1:43.8 T1 T2 B1 W1 W2W3 EV1 WCL2 EV2 WCR2 B2 1 2 3 4 5 9 8 7 6 10 11 12 13 2x4 4x4 2x4 3x6 3x8 4x44x4 3x8 3x8 9-2-4 9-2-4 18-4-8 9-2-4 4-8-14 4-8-14 9-2-4 4-5-6 13-7-10 4-5-6 18-1-0 4-5-6 18-4-8 0-3-8 1-2-07-3-81-2-08.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.37 0.70 0.49 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.14 -0.29 0.02 0.01 (loc) 7-9 7-9 6 7 l/defl >999 >752 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 83 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)9=640/0-3-8 (min. 0-1-8), 6=640/0-3-8 (min. 0-1-8) Max Horz9=-118(LC 12) Max Grav9=723(LC 2), 6=723(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-11=-685/48, 3-11=-602/75, 3-12=-602/75, 4-12=-685/48 BOT CHORD 8-9=-23/628, 7-8=-23/628, 6-7=-20/628 WEBS 3-7=-8/453, 2-9=-660/39, 4-6=-660/39 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 9-2-4, Exterior(2) 9-2-4 to 12-2-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V01 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:37 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-7JupXH?6_AGKrqsf8ounlStJzwEUPcHSpR17TgzWS_K Scale = 1:28.5 T1 T2 B1 ST1 1 2 3 4 5 6 7 8 2x4 4x4 2x41.5x4 0-0-4 0-0-4 8-7-5 8-7-1 4-3-10 4-3-10 8-3-13 4-0-2 8-7-5 0-3-8 0-0-44-3-10 0-0-412.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.27 0.14 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=166/8-6-13 (min. 0-1-8), 3=166/8-6-13 (min. 0-1-8), 4=227/8-6-13 (min. 0-1-8) Max Horz1=-69(LC 12) Max Uplift1=-18(LC 14), 3=-18(LC 14) Max Grav1=191(LC 2), 3=191(LC 2), 4=250(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 4-3-10, Exterior(2) 4-3-10 to 7-3-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V02 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:38 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-bVSBld0klUOBT_RriVP0HfPXAKcv83_c15ng?6zWS_J Scale = 1:20.6 T1 T2 B1 ST1 1 2 3 4 2x4 4x4 2x41.5x4 0-0-4 0-0-4 5-11-5 5-11-1 2-11-10 2-11-10 5-7-13 2-8-2 5-11-5 0-3-8 0-0-42-11-10 0-0-412.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.11 0.06 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=110/5-10-13 (min. 0-1-8), 3=110/5-10-13 (min. 0-1-8), 4=150/5-10-13 (min. 0-1-8) Max Horz1=-46(LC 12) Max Uplift1=-12(LC 14), 3=-12(LC 14) Max Grav1=127(LC 2), 3=127(LC 2), 4=166(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V03 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:39 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-3h0Zyz1NWoW25801FDxFqtyjGkxrtWTlGlWEYYzWS_I Scale = 1:11.0 T1 T2 B1 ST1 1 2 3 4 2x4 4x4 2x41.5x4 0-0-4 0-0-4 3-3-5 3-3-1 1-7-10 1-7-10 2-11-13 1-4-2 3-3-5 0-3-8 0-0-41-7-10 0-0-412.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.02 0.02 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=54/3-2-13 (min. 0-1-8), 3=54/3-2-13 (min. 0-1-8), 4=74/3-2-13 (min. 0-1-8) Max Horz1=23(LC 13) Max Uplift1=-6(LC 14), 3=-6(LC 14) Max Grav1=62(LC 2), 3=62(LC 2), 4=81(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V04 Truss Type GABLE Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:40 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-Xtay9J2?H5evjIbEpwSUN4Vp27Fkcx6uVPGn4?zWS_H Scale = 1:52.2 T1 EV2 B1 ST1 ST2 ST3 ST4 ST5 1 2 3 4 5 6 7 13 12 11 10 9 8 14 3x4 3x4 3x4 13-5-4 13-5-4 13-8-12 0-3-8 0-0-49-1-14 8.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.34 0.17 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 71 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud *Except* ST1: 2x4 HF/SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 13-8-12. (lb) - Max Horz1=239(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 8, 9, 10, 11, 12, 13 Max Grav All reactions 250 lb or less at joint(s) 1, 8, 9, 10, 11, 12 except 13=265(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-337/345, 2-3=-275/270 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-12 to 3-8-12, Interior(1) 3-8-12 to 13-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 9, 10, 11, 12, 13. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V05 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:40 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-Xtay9J2?H5evjIbEpwSUN4Vpb7F2cyEuVPGn4?zWS_H Scale = 1:41.0 T1 EV2 B1 ST1 ST2 1 2 3 4 7 6 5 8 9 3x4 2x4 2x41.5x4 1.5x4 1.5x4 1.5x4 10-5-4 10-5-4 10-8-12 0-3-8 0-0-47-1-14 8.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.37 0.15 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 10-8-6. (lb) - Max Horz1=184(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=418(LC 23), 7=274(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-282/278 WEBS 3-6=-266/143 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 10-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6, 7. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V06 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:41 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-?48KNf3d2PnmKSAQNezjvI1?0XcqLQ72j3?LcRzWS_G Scale = 1:30.8 T1 EV2 B1 ST1 1 2 3 5 4 6 2x4 1.5x4 1.5x41.5x4 1.5x4 7-5-4 7-5-4 7-8-12 0-3-8 0-0-45-1-14 8.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.26 0.11 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=80/7-8-6 (min. 0-1-8), 4=107/7-8-6 (min. 0-1-8), 5=316/7-8-6 (min. 0-1-8) Max Horz1=129(LC 11) Max Uplift4=-16(LC 11), 5=-38(LC 14) Max Grav1=111(LC 24), 4=126(LC 23), 5=357(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-268/141 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-12 to 3-8-12, Interior(1) 3-8-12 to 7-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V07 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:42 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-TGiia?3FpjvdybkcxLUySVaAUxx24tMByjlu8tzWS_F Scale = 1:18.6 T1 EV2 B1 1 2 3 4 2x4 1.5x4 1.5x4 4-5-4 4-5-4 4-8-12 0-3-8 0-0-43-1-14 8.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.28 0.18 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=145/4-8-6 (min. 0-1-8), 3=145/4-8-6 (min. 0-1-8) Max Horz1=75(LC 11) Max Uplift3=-8(LC 11) Max Grav1=164(LC 2), 3=165(LC 23) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 4-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V08 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:43 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-xSG4oK4tZ01UalJpU3?B_j7PNLJspJcLBNURhKzWS_E Scale = 1:8.6 T1 EV2 B1 1 2 3 2x4 1.5x4 1.5x4 1-5-4 1-5-4 1-8-12 0-3-8 0-0-41-1-14 8.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.02 0.01 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-8-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=39/1-8-6 (min. 0-1-8), 3=39/1-8-6 (min. 0-1-8) Max Horz1=20(LC 11) Max Uplift3=-2(LC 11) Max Grav1=44(LC 2), 3=44(LC 23) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V09 Truss Type GABLE Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:44 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-PfqS?g5VKK9LBvu?2mWQXwfValdSYjkUQ1E?DmzWS_D Scale = 1:54.3 T1 EV2 B1 ST1 ST2 ST3 ST4 ST5 ST6 T2 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 3x6 3x4 3x4 3x4 14-3-8 14-3-8 14-0-0 14-0-0 14-3-8 0-3-8 0-3-11 9-6-69-6-68.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.37 0.18 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 76 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud *Except* ST1: 2x4 HF/SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 9-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 14-3-8. (lb) - Max Horz1=249(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 10, 1, 11, 12, 13, 14, 15, 16 Max Grav All reactions 250 lb or less at joint(s) 10, 1, 11, 12, 13, 14, 15, 16 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-358/363, 2-17=-320/302, 3-17=-312/322, 3-4=-281/284 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 14-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 1, 11, 12, 13, 14, 15, 16. 9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V10 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:45 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-urNrD0675eHCp3TBcT1f48Chc8yAHBpeehzYlCzWS_C Scale = 1:46.8 T1 EV2 B1 ST1 ST2 1 2 3 4 7 6 5 8 9 3x4 2x4 2x41.5x4 1.5x4 1.5x4 1.5x4 12-0-0 12-0-0 12-3-8 0-3-8 0-0-48-2-68.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.29 0.15 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 12-3-2. (lb) - Max Horz1=213(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=401(LC 23), 7=346(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-301/283, 2-8=-278/307 WEBS 3-6=-255/131, 2-7=-253/117 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 12-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V11 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:45 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-urNrD0675eHCp3TBcT1f48Cgq8yEHCdeehzYlCzWS_C Scale = 1:39.4 T1 EV2 B1 ST1 ST2 1 2 3 4 7 6 5 8 9 2x4 2x4 1.5x41.5x4 1.5x4 1.5x4 1.5x4 10-0-0 10-0-0 10-3-8 0-3-8 0-0-46-10-6 8.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.34 0.14 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 10-3-2. (lb) - Max Horz1=176(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=420(LC 23), 7=262(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-276/272 WEBS 3-6=-266/144 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 10-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6, 7. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V12 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:46 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-M1xDQM6msxP3RD2NABZucLls?YJl0fFntLj5IezWS_B Scale = 1:33.4 T1 EV2 B1 ST1 1 2 3 5 4 6 7 2x4 1.5x4 1.5x41.5x4 1.5x4 8-0-0 8-0-0 8-3-8 0-3-8 0-0-40-3-11 5-6-65-6-68.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.31 0.13 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=101/8-3-2 (min. 0-1-8), 4=103/8-3-2 (min. 0-1-8), 5=339/8-3-2 (min. 0-1-8) Max Horz1=140(LC 11) Max Uplift4=-18(LC 11), 5=-41(LC 14) Max Grav1=133(LC 24), 4=122(LC 23), 5=383(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-287/148 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 8-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V13 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:47 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-qEVbdi7OdFXw2Ndaju479ZH21yfNl7ow6?Sfq5zWS_A Scale = 1:25.4 T1 EV2 B1 ST1 1 2 3 5 4 6 7 2x4 1.5x4 1.5x4 1.5x4 1.5x4 6-0-0 6-0-0 6-3-8 0-3-8 0-0-40-3-11 4-2-64-2-68.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.10 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=10/6-3-2 (min. 0-1-8), 4=111/6-3-2 (min. 0-1-8), 5=280/6-3-2 (min. 0-1-8) Max Horz1=103(LC 11) Max Uplift1=-20(LC 12), 4=-13(LC 11), 5=-34(LC 14) Max Grav1=54(LC 11), 4=129(LC 23), 5=317(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 6-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V14 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:47 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-qEVbdi7OdFXw2Ndaju479ZH1Ayepl7cw6?Sfq5zWS_A Scale = 1:17.2 T1 EV2 B1 1 2 3 4 2x4 1.5x4 1.5x4 4-0-0 4-0-0 4-3-8 0-3-8 0-0-42-10-6 8.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.22 0.14 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=130/4-3-2 (min. 0-1-8), 3=130/4-3-2 (min. 0-1-8) Max Horz1=67(LC 11) Max Uplift3=-7(LC 11) Max Grav1=147(LC 2), 3=148(LC 23) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 4-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks DE Job # 65028-W1 Dansco Engineering, LLC Date: 3/28/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1903387-12T Truss V15 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) Run: 8.200 s Apr 7 2018 Print: 8.200 s Apr 7 2018 MiTek Industries, Inc. Thu Mar 28 10:23:48 2019 Page 1Stark Truss Company Inc., Rensselaer, IN 47978, mbbraddock ID:lae84f1cheQvXMAomonDjPzzSaF-IQ3zr280OZfmgWCmHcbMhmqFlM0pUar4KfCCMXzWS_9 Scale = 1:10.5 T1 EV2 B1 1 2 3 2x4 1.5x4 1.5x4 2-0-0 2-0-0 2-3-8 0-3-8 0-0-41-6-68.0012 LOADING (psf) TCLL (roof) Snow (Pf/Pg) TCDL BCLL BCDL 20.0 15.4/20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 185/144 LUMBER- TOP CHORD2x4 HF/SPF No.2 BOT CHORD2x4 HF/SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size)1=59/2-3-2 (min. 0-1-8), 3=59/2-3-2 (min. 0-1-8) Max Horz1=30(LC 11) Max Uplift3=-3(LC 11) Max Grav1=67(LC 2), 3=67(LC 23) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 04/08/19 Mike Sheeks