Loading...
HomeMy WebLinkAboutLEGACY PRAIRIE 1303 - LP1303 (AS DESIGNED)IECC 2009 Performance Compliance Property 7238 ZANESVILLE RD CARMEL, IN 46033 Model: FOXHALL Community: LEGACY PRAIRIE 130 LP1303 (AS DESIGNED) LEGACY PRAIRIE 1303 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S844 S109 S350 $1,303 S583 SO $1,886 Requirements C-M, Energy Solutions As designed S610 S128 S350 $1,089 S583 SO $1,672 C4405.3 Performance-based compliance passes by 16.5% 402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R405.2 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 16.5%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Signature: Organization: TSI Energy Solutions Digitally signed: 316119 at 10:02 AM Ekotrope RATER - Version 3.1.0.2123 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 7238 ZANESVILLE RD ilriPro P CARMEL, IN 46033 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls NIA Framed Floor R-38 Slab R-10.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.32, SHGC: 0.34 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 118.0 CFM @ 25Pa Total Duct Leakage 189.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. — -y Name: Matthew Timmons Signature: ��r�,.c z � — Organization: TSI Energy Solutions Digitally signed: 316119 at 10:02 AM Ekotrope RATER - Version 3.1.0.2123 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). Thissoftware is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property Organization 7238 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: FOXHALL Community: LEGACY PRAIRIE 130 Builder LENNAR HOMES LP1303 (AS DESIGNED) LEGACY PRAIRIE 1303 General Building Information Conditioned Area (sq ft) 2,364 Conditioned Volume (cubic ft) 19,776 Insulated Shell Area (sq ft) 5,382 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB 1 (536 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Name: SLAB 2 (66 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: OVER GARAGE (411 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (950 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (85 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property organization 7238 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: FOXHALL Community: LEGACY PRAIRIE 130. Builder LENNAR HOMES LP1303 (AS DESIGNED) LEGACY PRAIRIE 1303 Name: CONDIGAR (364 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIGAR 2X6 (112 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I El Name: CONDICOND (1,664 s.f.) R-0 continuous insulation, R-22 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (71 s.f.) R: 13.575 Name: CONDIGAR (59 s.f.) R: 10.876 Name: CONDICOND (118 s.f.) R: 10.876 Roof El Name: MAIN (946 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected C", Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization Inspection Status 7238 ZANESVILLE RD TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: FOXHALL Community: LEGACY PRAIRIE 130 Builder LENNAR HOMES LPI 303 (AS DESIGNED) LEGACY PRAIRIE 1303 E] Name: FRONT (99 s.f.), U: 0.320, SHGC: 0.34, Orientation: EAST E] Name: BACK (114 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST El Name: SLIDER (33 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST El Name: GD (20 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE Air conditioner {2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 1,648 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 7238 ZANESVILLE RD CARMEL, IN 46033 Model: FOXHALL Community: LEGACY PRAIRIE 130: LP1303 (AS DESIGNED) LEGACY PRAIRIE 1303 Duct Leakage Duct System 1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 118.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 189.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 7238 ZANESVILLE RD TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: FOXHALL Community: LEGACY PRAIRIE 1303 Builder LENNAR HOMES LP1303 [AS DESIGNED] LEGACY PRAIRIE 1303 enera?Building Informationmber Of Bedrooms 3 mber Of Floors 3 nditioned Floor Area [sq_ ft.] 2;364 conditioned, attached garage? Yes nditioned Volume [Cu. ft.] I 19;776 tal Units in Building 1 sidence Type Townhouse; inside unit odel FOXHALL mmunity LEGACY PRAIRIE 1303 mate Zone 5A Basement Wall Am None Present Basement Wall Library List None Present C-M, Energy Solutions xposed Surface Area Location Enclosing ry Area SLAB 1 R-10, 2'down 53 On Grade 123 0 536.0 sq. ft. Exposed Exterior Conditioned Space SLAB 2 R-10, 2'down 35 On Grade 123 0 66.0 sq. rL Exposed Exterior Conditioned Space Slab Library Lisi Name Wall R-10, 2'down Woad Frame / Other No ❑ 2 1 D 0.00 1 Building Summary Property Organization 7238 ZANESVILLE RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: FOXHALL Community: LEGACY PRAIRIE 1303 Builder LENNAR HOMES LP1303 (AS DESIGNED) LEGACY PRAIRIE 1303 ramed Floor Name Library Type Ca OVER GARAGE R-38, GR1 Framed Floor Library List Name R -value R-38, GR1 33.825 Rim Joist Name CONDIAMB CONDJCOND C O N DIGAR Rim Joist Library List Name G1 R-13, OSB G1 R-13. R-3.0 C-M Energy Solutions Inspection Status Results are projected e Surface Area Location 1.23 Above Grade 411.0 sq. ft Unconditioned, attached garage G1 R-13, R-3.0 71.0 sq. ft. Exposed Exterior G1 R-13, OSB 118.0 sq. ft. Conditioned Space (Adiabatic) G1 R-13, OSB 59.0 sq. ft. Unconditioned, attached garage ■ R -value 10.876 13.575 Ill Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-13 BATT R-3.0 Medium 950.0 sq. fl. Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 85.0 sq. fl. Exposed Exterior CONDJCOND G1 R-22 Dbl Wall Medium 1.664.0 sq. ft. Conditioned Space (Adiabatic) 2 Building Summary Property 7238 ZANESVILLE RD CARMEL, IN 46033 Model: FOXHALL Community: LEGACY PRAIRIE 1303 LP1303 [AS DESIGNED] LEGACY PRAIRIE 1303 Name Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Library Type Inspection Status Results are projected Surface Calor Surface Area C-MEnergy Solutions Location CONDIGAR G1 R-13 Gar Walls Medium 364.0 sq. ft. Unconditioned, attached garage CONDIGAR 2X6 G1 R-19, 2x6 GAR Medium 112.0 sq. fL Unconditioned, attached garage Wall Library List Name R -value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, 2x6 GAR 16218 G1 R-19, R-3.0 2X6 20217 G1 R-22 Dhl Wall 18.407 Glazing Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft Te Overhang Ft Te Orientation Surface Area Assignment Top Bottom BACK 11-.32, SHGG.34 CONDIAMB ❑ 0 ❑ West 114.0 sq. 11 FRONT 11-.32, SHGG.34 CONDIAMB ❑ 0 ❑ East 99.0 sq. fL GD 11-.32, SHGG.34 CONDIAMB 2X6 ❑ 0 0 West 20.0 sq. fL SLIDER U-.32, SHGG.34 CONDIAMB ❑ 0 0 West 33.0 sq. ft Glazing Library List Name Shg c U -factor U-.32, SHGC-.34 0.34 0.320 3 Building Summary Property 7238 ZANESVILLE RD CARMEL, IN 46033 Model: FOXHALL Community: LEGACY PRAIRIE 1303 LP1303 [AS DESIGNED] LEGACY PRAIRIE 1303 kyligh Skylight Library List Opaque Door Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta nce FRONT Steel Door CONDIAMB 2X6 0.9 0.75 Medium 20.0 sq. it Exposed Exterior GARAGE Steel Door CONDIGAR 2X6 0.9 0.75 Medium 18.0 sq- ft Exposed Exterior Opaque Door Library List Name U -factor 0.182 Roof Insulation Name imm Library Typ MAIN R-38 Blown. GR1 krea Clay or Concrete Root P.f.] Tiles 946 No Roof Insulation Library List Name Has Radiant Barrier R -value '•0 �- -I :a l No 38268 n Medium 946-0 sq. ft Attic 4 Building Summary Property 7238 ZANESVILLE RD CARMEL, IN 46033 Model: FOXHALL Community: LEGACY PRAIRIE 1303 LP1303 [AS DESIGNED] LEGACY PRAIRIE 1303 FWhole House Infiltration Infiltration 5 ACH at 50 Pa Mechanical Ventilation Lighting , °I Interior Fitiorescent Lighting Onsite Generation Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Blower -door tested 4 rang Y. txsenor rmorescem Lighting 100 0 None Present Onsite Generation Library List None Present Solar Generation Solar Generation Library List C-M, Energy Solutions Lighting 1❑0 Building Summary Property Organization Inspection Status 7238 ZANESVILLE RD TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons PSG (Single Speed) Model: FOXHALL 95.5 AFUE Heating Capacity [kBtulh] Community: LEGACY PRAIRIE 130 Builder No EAE [kWh] LENNAR HOMES Equipment Type: CA13NA0361,m LP1303 (AS DESIGNED) Fuel Type Electric LEGACY PRAIRIE 1303 Forced Air Motor Type onditioning Equipment Cooling Efficiency 13 SEER Name Library Type Heating Percent Load Co( Air conditioner (2) Equipment Type: RE350* CA13NA036 0% C-M, Energy Solutions g Percent Load Hot Water 100% 0% Fuel4red air 915SA4808OS17 100% 0% 0% distribution (1) Water Heating (3) RE350" 0% 0% 100% 1 Equipment Type: 915SA4808OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 Equipment Type: CA13NA0361,m Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 34.2 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 Building Summary Property 7238 ZANESVILLE RD CARMEL, IN 46033 Model: FOXHALL Community: LEGACY PRAIRIE 1303 LP1303 [AS DESIGNED] LEGACY PRAIRIE 1303 1bution System tion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area [sq. ft.] ]uct Area [sq. ft_] akage to Outdoors (CFM25) akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Ctm Per Watt Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Forced Air Fuel -fired air distribution (1) Air conditioner (2) 2364 2 3❑ 3❑ 478.7 177.3 118 189 Post -Construction Yes Conditioned Space 5❑ 50 Attic (well vented; under insulation) 5❑ 5❑ Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property Organization Inspection Status 7238 ZANESVILLE RD TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: FOXHALL No Community: LEGACY PRAIRIE 1303 Builder Recirculation System Pipe Loop Length [ft] LENNAR HOMES LP1303 [AS DESIGNED] No LEGACY PRAIRIE 1303 ater Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length IN Hot Water Pipe Length [ft] 86 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 30 Drain Water Heat Recovery? No r othes Dryer elType Electric f 2.32 ld Utilization Timer Controls Clothes Washer Label Energy Rating 704 kWh/Year Electric Rate 0.081kWh Annual Gas Cost $23.00 Gas Rate $0.581Therm Capacity 2.874 1 mef 0.331 Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Yes Standard 270 kWh Electric No No 709 kWh/Year "M � TSI Energy Solutions ,�