HomeMy WebLinkAbout42240013 - WWC 13 - Truss DetailsDE
DANSCO ENGINEERING, LLC
P.O. Box 3400
Apollo Beach, FL 33572
Telephone (813) 645-0166
Facsimile (813) 645-9698
The truss drawing(s) attached have been prepared by Dansco Engineering, LLC under
my direct supervision and control based on the parameters provided by Stark Truss Inc.
Job: 1903481-12T
81 truss design(s)
64866-W1
3/2/19
Samuel A. Greenberg, P.E.
Indiana Reg. #19700485
Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural
gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length
is the distance from the top chord to bottom chord.
The seal on these drawings indicate acceptance of professional engineering
responsibility solely for the truss components shown. The suitability and use of this
component for any particular building is the responsibility of the building designer, per
ANSI/TPI 1-2007 Chapter 2.
Warning !—Verify design parameters and read notes before use.
These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of
design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown is
for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication,
quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss
Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate
Institute, 583 D’Onofrio Drive, Madison, WI 53719
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
J01
TrussType
Jack-Open
Qty
8
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:292019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-ulmUvt5u0Pxzww5P2xJf_gzdNkYZHCtHdFOrBazZ0Au
Scale=1:21.6
W1
T1
B1
1
2
5
3
43x4
3x4
2-0-0
2-0-0
-0-10-4
0-10-4
2-0-0
2-0-0
2-1-143-7-143-2-63-7-149.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.35
0.20
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.01
-0.04
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 9 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)5=130/0-6-0(min. 0-1-8), 3=34/Mechanical, 4=17/Mechanical
Max Horz5=87(LC 13)
Max Uplift3=-72(LC 16), 4=-28(LC 13)
MaxGrav5=150(LC 2), 3=65(LC 30), 4=51(LC 14)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft exposed ; end verticalleft exposed;C-C formembers
and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 72 lb uplift at joint 3 and 28 lb uplift at
joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
J02
TrussType
Jack-Open
Qty
19
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:302019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-MyKs6D6Wnj3qY4gbbequWuWob8uX0f7Qsv7Ok0zZ0At
Scale=1:24.3
W1
T1
B1
1
2
5
6
7
3
4
3x4
2x4
4-1-8
4-1-8
-0-10-4
0-10-4
4-1-8
4-1-8
1-1-144-3-03-9-84-3-09.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.32
0.22
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.03
-0.04
0.05
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 13 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-1-8 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)5=196/0-6-0(min. 0-1-8), 3=89/Mechanical, 4=44/Mechanical
Max Horz5=133(LC 16)
Max Uplift3=-101(LC 16), 4=-5(LC 16)
MaxGrav5=224(LC 2), 3=122(LC 30), 4=75(LC 7)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-4 to 2-1-12,Interior(1) 2-1-12 to 4-0-12zone;cantileverleft exposed ;
endverticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 101 lb uplift at joint 3 and 5 lb uplift at
joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
J03
TrussType
Jack-Open
Qty
22
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:312019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-q8uEKZ69Y0Bh9DFn9ML7352zQYD2l6NZ5ZtxGSzZ0As
Scale=1:26.2
W1
T1
B1
1
2
5
6
7
3
4
4x4
2x4
4-7-8
4-7-8
-0-10-4
0-10-4
4-7-8
4-7-8
1-1-144-7-84-2-04-7-89.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.38
0.27
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.04
-0.06
0.06
(loc)
4-5
4-5
3
l/defl
>999
>826
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 14 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-7-8 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)5=213/0-6-0(min. 0-1-8), 3=101/Mechanical, 4=50/Mechanical
Max Horz5=148(LC 16)
Max Uplift3=-112(LC 16), 4=-4(LC 16)
MaxGrav5=243(LC 2), 3=137(LC 30), 4=85(LC 7)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-4 to 2-1-12,Interior(1) 2-1-12 to 4-6-12zone;cantileverleft exposed ;
endverticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 112 lb uplift at joint 3 and 4 lb uplift at
joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
J04
TrussType
Jack-OpenGirder
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:322019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-IKSdXv7nJKJYnNp_j3tMbJb8GycTUZdjJDcVouzZ0Ar
Scale:3/4"=1'
W1
T1
B1
1
2
5
6
3
4
2x4
3x4
3-1-7
3-1-7
-1-10-1
1-10-1
3-1-7
3-1-7
1-3-62-6-152-2-82-6-154.9912
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.38
0.13
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.01
-0.02
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 11 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-1-7 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)5=164/0-6-1(min. 0-1-8), 3=15/Mechanical, 4=5/Mechanical
Max Horz5=71(LC 11)
Max Uplift5=-88(LC 8), 3=-58(LC 16), 4=-27(LC 11)
MaxGrav5=233(LC 18), 3=18(LC 19), 4=38(LC 7)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft exposed ; end verticalleft exposed; porchleft and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 88 lb uplift at joint 5, 58 lb uplift at joint 3
and 27 lb uplift at joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51
Trapezoidal Loads(plf)
Vert: 2=-2(F=24,B=24)-to-3=-40(F=6,B=6), 5=0(F=10,B=10)-to-4=-16(F=2,B=2)
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
J05
TrussType
Jack-Open
Qty
7
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:332019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-mX0?lF8P4eROPXOAHmOb8W8MCLxOD?ssYtM2KLzZ0Aq
Scale=1:16.4
W1
T1
B1
1
2
5
3
42x4
3x4
1-10-0
1-10-0
-1-0-4
1-0-4
1-10-0
1-10-0
1-3-62-7-142-2-62-7-149.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.17
0.08
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.01
(loc)
5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 8 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 1-10-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)5=139/0-4-0(min. 0-1-8), 3=26/Mechanical, 4=13/Mechanical
Max Horz5=67(LC 13)
Max Uplift3=-50(LC 16), 4=-25(LC 13)
MaxGrav5=162(LC 22), 3=44(LC 30), 4=30(LC 7)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft exposed ; end verticalleft exposed; porchleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 50 lb uplift at joint 3 and 25 lb uplift at
joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
J06
TrussType
Jack-Open
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:342019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-EjaNyb91rxZF0hzMqUvqgkgYhlHryS60nX5btnzZ0Ap
Scale=1:15.1
W1
T1
B1
1
2
5
3
4
2x4
2x4
1-7-15
1-7-15
-0-10-4
0-10-4
1-7-15
1-7-15
1-1-142-4-139.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.12
0.07
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
-0.01
(loc)
5
5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 7 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 1-7-15 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)5=121/0-6-0(min. 0-1-8), 3=24/Mechanical, 4=12/Mechanical
Max Horz5=59(LC 13)
Max Uplift3=-45(LC 16), 4=-12(LC 16)
MaxGrav5=140(LC 2), 3=41(LC 30), 4=27(LC 7)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 45 lb uplift at joint 3 and 12 lb uplift at
joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
J07
TrussType
DiagonalHipGirder
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:352019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-jv7lAx9fbFh6erYYOBQ3DxDgl9bVhvM90Br9PDzZ0Ao
Scale=1:20.8
W1
T1
B1
1
2
5
6
7
8
3
9 10
4
3x4
3x4
5-4-12
5-4-12
-1-6-8
1-6-8
5-4-12
5-4-12
1-1-143-4-133-0-63-4-134.9912
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.30
0.23
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.06
-0.08
-0.05
(loc)
4-5
4-5
3
l/defl
>999
>797
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 16 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-4-12 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)5=185/0-9-11(min. 0-1-8), 3=106/Mechanical, 4=46/Mechanical
Max Horz5=86(LC 16)
Max Uplift5=-107(LC 16), 3=-80(LC 12)
MaxGrav5=212(LC 2), 3=125(LC 2), 4=92(LC 7)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 107 lb uplift at joint 5 and 80 lb uplift at
joint 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 85 lb down and 17 lb up at
1-11-0, and 75 lb down and 37 lb up at 3-0-13 on top chord, and 5 lb down and 11 lb up at 1-11-0, and 13 lb down and 20 lb up at
3-0-13 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51
Concentrated Loads(lb)
Vert: 9=1(B) 10=0(F)
Trapezoidal Loads(plf)
Vert: 2=-2(F=24,B=24)-to-3=-69(F=-9,B=-9), 5=0(F=10,B=10)-to-4=-27(F=-3,B=-3)
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
J08
TrussType
Jack-Open
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:352019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-jv7lAx9fbFh6erYYOBQ3DxDi_9eLhvM90Br9PDzZ0Ao
Scale=1:12.6
W1
T1
B1
1
2
5
3
4
1.5x4
2x4
1-8-4
1-8-4
-1-2-12
1-2-12
1-8-4
1-8-4
1-1-01-11-26.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.15
0.05
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 7 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 1-8-4 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)5=155/0-6-0(min. 0-1-8), 3=15/Mechanical, 4=8/Mechanical
Max Horz5=51(LC 13)
Max Uplift5=-29(LC 16), 3=-27(LC 16), 4=-3(LC 13)
MaxGrav5=193(LC 22), 3=18(LC 30), 4=26(LC 7)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 29 lb uplift at joint 5, 27 lb uplift at joint 3
and 3 lb uplift at joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
J09
TrussType
Jack-Open
Qty
9
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:372019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-fIFWacBv7sxqu8ixWcSXIMI?1zHl9psSTUKGT6zZ0Am
Scale=1:20.2
W1
T1
B1
1
2
5
6
7
3
4
3x4
1.5x4
4-9-0
4-9-0
-1-2-12
1-2-12
4-9-0
4-9-0
1-1-03-5-83-0-133-5-86.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.37
0.25
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.03
-0.06
-0.04
(loc)
4-5
4-5
3
l/defl
>999
>908
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 14 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-9-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)5=241/0-6-0(min. 0-1-8), 3=101/Mechanical, 4=49/Mechanical
Max Horz5=105(LC 16)
Max Uplift5=-32(LC 16), 3=-83(LC 16)
MaxGrav5=277(LC 2), 3=119(LC 2), 4=85(LC 7)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 4-8-4zone;cantileverleft exposed ;
endverticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 32 lb uplift at joint 5 and 83 lb uplift at
joint 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
PB01
TrussType
Piggyback
Qty
4
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:382019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-7UpuoyCYuA3hVIH73KzmrarEXMdUuG6bi83p0YzZ0Al
Scale=1:15.2
T1 T1
B11
2
3
4 5
3x4
2x4 2x4
5-10-0
5-10-0
2-11-0
2-11-0
5-10-0
2-11-0
0-4-102-2-40-1-100-4-100-1-109.0012
PlateOffsets(X,Y)-- [3:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.07
0.21
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 14 lb FT= 20%
GRIP
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-10-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)2=180/4-5-5(min. 0-1-8), 4=180/4-5-5(min. 0-1-8)
Max Horz2=-52(LC 14)
Max Uplift2=-32(LC 16), 4=-32(LC 17)
MaxGrav2=204(LC 2), 4=204(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Gablerequirescontinuous bottomchord bearing.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 32 lb uplift at joint 2 and 32 lb uplift at
joint 4.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
PB01GE
TrussType
Piggyback
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:392019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-bhNG?IDAfUBY7SsKd1V?NnNPGm?Odj?lwopMY_zZ0Ak
Scale=1:15.2
T1 T1
B1
ST1
1
2
3
4 5
6
4x4
2x4 2x41.5x4
5-10-0
5-10-0
2-11-0
2-11-0
5-10-0
2-11-0
0-4-102-2-40-1-100-4-100-1-109.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.07
0.04
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 15 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-10-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)2=111/4-5-5(min. 0-1-8), 4=111/4-5-5(min. 0-1-8), 6=138/4-5-5(min. 0-1-8)
Max Horz2=52(LC 15)
Max Uplift2=-36(LC 16), 4=-43(LC 17)
MaxGrav2=128(LC 2), 4=128(LC 2), 6=153(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Gablerequirescontinuous bottomchord bearing.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 36 lb uplift at joint 2 and 43 lb uplift at
joint 4.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
PB02
TrussType
Piggyback
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:402019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-3txeDeDoQnJPlcRWBl0Ew?wXmAJ0M9Nu9SYw4RzZ0Aj
Scale=1:48.6
0-1-140-1-14T1
T2
T1
B1
ST1ST1ST1 ST1 ST1
T3
B212
3 4 5 6 7 8 9 10
11
12
18 1716 15 14 13
19
3x6
3x6 3x6
3x4
3x6
3x4
27-2-0
27-2-0
3-6-0
3-6-0
23-8-0
20-2-0
27-2-0
3-6-0
0-4-31-5-81-9-00-1-100-4-30-1-106.0012
PlateOffsets(X,Y)-- [3:0-3-0,Edge], [10:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.21
0.15
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.01
0.01
(loc)
12
12
11
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 67 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 25-2-14.
(lb)-Max Horz2=26(LC 20)
Max UpliftAll uplift 100 lb orless at joint(s) 2, 15, 17, 18, 14, 13, 11
MaxGravAllreactions 250 lb orless at joint(s) except 2=307(LC 39), 15=430(LC 38), 17=429(LC 38),
18=419(LC 38), 14=429(LC 38), 13=419(LC 38), 11=307(LC 39)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-273/91, 10-11=-273/93
WEBS 6-15=-347/114, 5-17=-355/120, 4-18=-320/111, 7-14=-355/120, 9-13=-320/110
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 7-8-15,Interior(1) 7-8-15 to 23-8-0,Exterior(2) 23-8-0 to 26-9-13
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 15, 17, 18, 14,
13, 11.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
PB03
TrussType
Piggyback
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:412019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-X3V0Q_EQB5SGMm?ilSXTTCThtafn5cP2O6ITctzZ0Ai
Scale:1/4"=1'0-1-140-1-14T1
T2
T1
B1
ST2ST2ST1 ST2 ST1
B212
3 4 5 6 7 8 9
10
11
17 1615 14 13 12
18
19
20 21 22 23
24
25
3x6
3x6
3x4
3x6
3x4
27-2-0
27-2-0
6-6-0
6-6-0
20-8-0
14-2-0
27-2-0
6-6-0
0-4-32-11-83-3-00-1-100-4-30-1-106.0012
PlateOffsets(X,Y)-- [4:0-3-0,Edge], [8:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.32
0.18
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.02
0.00
(loc)
11
11
10
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 76 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 25-2-14.
(lb)-Max Horz2=53(LC 16)
Max UpliftAll uplift 100 lb orless at joint(s) 2, 14, 16, 17, 13, 12, 10
MaxGravAllreactions 250 lb orless at joint(s) 2, 10 except 14=435(LC 38), 16=420(LC 38), 17=505(LC 39),
13=420(LC 38), 12=505(LC 39)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 6-14=-352/117, 5-16=-347/115, 3-17=-380/156, 7-13=-347/116, 9-12=-380/156
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 3-4-3,Interior(1) 3-4-3 to 6-6-0,Exterior(2) 6-6-0 to 24-10-15,
Interior(1) 24-10-15 to 26-9-13zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 14, 16, 17, 13,
12, 10.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
PB04
TrussType
Piggyback
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:432019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-UScnrgGgjii_c395stZxYdY0BNLUZVjKrQnahmzZ0Ag
Scale:1/4"=1'0-1-140-1-14T1
T2
T1
B1
ST2ST2
ST1
ST2
ST1
B212
3
4 5 6
7
8 9
15 1413 12 11 10
16
17
18 19
20
21
3x4
3x6
6x6 6x6
3x4
27-2-0
27-2-0
9-6-0
9-6-0
17-8-0
8-2-0
27-2-0
9-6-0
0-4-34-5-84-9-00-1-100-4-30-1-106.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.33
0.16
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.02
0.00
(loc)
9
9
8
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 82 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 25-2-14.
(lb)-Max Horz2=79(LC 20)
Max UpliftAll uplift 100 lb orless at joint(s) 2, 12, 14, 11, 8 except 15=-142(LC 16), 10=-141(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) except 2=263(LC 39), 12=503(LC 38), 14=264(LC 38),
15=552(LC 39), 11=264(LC 38), 10=552(LC 39), 8=263(LC 39)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 5-12=-419/139, 3-15=-430/185, 7-10=-430/184
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 3-4-3,Interior(1) 3-4-3 to 9-6-0,Exterior(2) 9-6-0 to 21-10-15,
Interior(1) 21-10-15 to 26-9-13zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 12, 14, 11, 8
except(jt=lb) 15=142, 10=141.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
PB05
TrussType
Piggyback
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:442019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-yeA920GIU0qrDDkHQa4A4r5CXnhHIyUU44W7DCzZ0Af
Scale:1/4"=1'0-1-140-1-14T1
T2
T1
B1
ST3
ST2
ST1
ST2
ST1
B212
3
4
5 6 7
8
9
10
11
17 1615 14 13 12
18
19
20
21 22
23
24
25
3x6
3x6
3x4
3x6
3x4
27-2-0
27-2-0
12-6-0
12-6-0
14-8-0
2-2-0
27-2-0
12-6-0
0-4-35-11-86-3-00-1-100-4-30-1-106.0012
PlateOffsets(X,Y)-- [5:0-3-0,Edge], [7:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.29
0.19
0.14
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.02
0.01
(loc)
11
11
10
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 85 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 25-2-14.
(lb)-Max Horz2=-106(LC 21)
Max UpliftAll uplift 100 lb orless at joint(s) 2, 16, 13, 10 except 17=-136(LC 16), 12=-136(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) except 2=276(LC 39), 14=282(LC 38), 16=381(LC 39),
17=537(LC 39), 13=381(LC 39), 12=537(LC 39), 10=276(LC 39)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 4-16=-315/146, 3-17=-413/178, 8-13=-315/146, 9-12=-413/179
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 3-4-3,Interior(1) 3-4-3 to 12-6-0,Exterior(2) 12-6-0 to 14-8-0,
Interior(1) 18-10-15 to 26-9-13zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 16, 13, 10
except(jt=lb) 17=136, 12=136.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
PB06
TrussType
Piggyback
Qty
3
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:452019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-QqkXGMHxFKyhrNJT_IbPd2dOaB0J1PEdJkGhlezZ0Ae
Scale=1:46.6
T1 T1
B1
ST3
ST2
ST1
ST2
ST1
B212
3
4
5
6
7
8 9
15 1413 12 11 10
16
17
18 19 20
21
4x4
3x4
3x6
3x4
27-2-0
27-2-0
13-7-0
13-7-0
27-2-0
13-7-0
0-4-36-7-146-9-80-1-100-4-30-1-106.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.21
0.14
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.02
0.00
(loc)
9
9
8
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 86 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 25-2-14.
(lb)-Max Horz2=117(LC 20)
Max UpliftAll uplift 100 lb orless at joint(s) 2, 8 except 14=-112(LC 16), 15=-132(LC 16), 11=-112(LC 17),
10=-131(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 2, 8 except 12=285(LC 2), 14=317(LC 34), 15=393(LC 2),
11=317(LC 35), 10=393(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 3-15=-279/174, 7-10=-279/174
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 3-4-3,Interior(1) 3-4-3 to 13-7-0,Exterior(2) 13-7-0 to 16-7-0zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)All plates are 1.5x4MT20 unless otherwiseindicated.
7)Gablerequirescontinuous bottomchord bearing.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 8 except(jt=lb)
14=112, 15=132, 11=112, 10=131.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
11)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
PB07
TrussType
Piggyback
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:462019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-u1IvThIZ0d4YTXugX?7fAGAZJbMYmsOnYO?EI5zZ0Ad
Scale=1:47.3
T1 T1
B1
ST3
ST2
ST1
ST2
ST1
B212
3
4
5
6
7
8 9
15 1413 12 11 10
16
17
18 19 20
21
4x8
3x4
3x6
3x4
27-2-0
27-2-0
13-5-4
13-5-4
13-8-12
0-3-8
27-2-0
13-5-4
0-4-36-8-100-1-100-4-30-1-106.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.21
0.14
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.02
0.00
(loc)
9
9
8
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 86 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 25-2-14.
(lb)-Max Horz2=-116(LC 21)
Max UpliftAll uplift 100 lb orless at joint(s) 2, 8 except 14=-112(LC 16), 15=-132(LC 16), 11=-112(LC 17),
10=-131(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 2, 8 except 12=285(LC 2), 14=316(LC 34), 15=393(LC 2),
11=318(LC 35), 10=392(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 3-15=-279/174, 7-10=-278/174
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 3-4-3,Interior(1) 3-4-3 to 13-6-10,Exterior(2) 13-6-10 to 16-6-10
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)All plates are 1.5x4MT20 unless otherwiseindicated.
7)Gablerequirescontinuous bottomchord bearing.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 8 except(jt=lb)
14=112, 15=132, 11=112, 10=131.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
11)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
PB08
TrussType
Piggyback
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:482019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-qPQguNJpYFKGir22fQ97FhFt2O2dEmw4?iULMzzZ0Ab
Scale:1/4"=1'0-1-140-1-14T1
T2
T1
B1
ST3ST2
ST1
ST2
ST1
B212
3
4 5 6 7 8
9
10
11
17 1615 14 13 12
18
19
20
2122 2324
25
26
27
3x6
3x6
3x4
3x6
3x4
27-2-0
27-2-0
10-5-4
10-5-4
16-8-12
6-3-8
27-2-0
10-5-4
0-4-34-11-25-2-100-1-100-4-30-1-106.0012
PlateOffsets(X,Y)-- [5:0-3-0,Edge], [7:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.32
0.16
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.02
0.01
(loc)
11
11
10
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 83 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 25-2-14.
(lb)-Max Horz2=-88(LC 17)
Max UpliftAll uplift 100 lb orless at joint(s) 2, 14, 16, 13, 10 except 17=-143(LC 16), 12=-144(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) except 2=260(LC 39), 14=443(LC 38), 16=326(LC 39),
17=543(LC 39), 13=326(LC 39), 12=543(LC 39), 10=260(LC 39)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 6-14=-359/112, 4-16=-260/101, 3-17=-421/186, 8-13=-260/101, 9-12=-421/188
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 3-4-3,Interior(1) 3-4-3 to 10-5-4,Exterior(2) 10-5-4 to 20-11-11,
Interior(1) 20-11-11 to 26-9-13zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 14, 16, 13, 10
except(jt=lb) 17=143, 12=144.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
PB09
TrussType
Piggyback
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:492019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-Ic_26jKRIYS7K_dFD8gMnuo3BoOhzECDEMEuvPzZ0Aa
Scale:1/4"=1'0-1-140-1-14T1
T2
T1
B1
ST2ST2
ST1
ST2
ST1
B212
3
4 5 6 7 8
9
10
11
17 1615 14 13 12
18
19 20
21
3x6
3x6
3x4
3x6
3x4
27-2-0
27-2-0
7-5-4
7-5-4
19-8-12
12-3-8
27-2-0
7-5-4
0-4-33-5-23-8-100-1-100-4-30-1-106.0012
PlateOffsets(X,Y)-- [4:0-3-0,Edge], [8:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.30
0.17
0.10
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.02
0.00
(loc)
11
11
10
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 78 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 25-2-14.
(lb)-Max Horz2=61(LC 16)
Max UpliftAll uplift 100 lb orless at joint(s) 2, 14, 16, 13, 10 except 17=-113(LC 16), 12=-109(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) except 2=267(LC 39), 14=448(LC 38), 16=387(LC 38),
17=507(LC 39), 13=387(LC 38), 12=507(LC 39), 10=267(LC 39)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 6-14=-365/123, 5-16=-314/100, 3-17=-383/162, 7-13=-314/100, 9-12=-383/164
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 3-4-3,Interior(1) 3-4-3 to 7-5-4,Exterior(2) 7-5-4 to 23-11-11,
Interior(1) 23-11-11 to 26-9-13zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 14, 16, 13, 10
except(jt=lb) 17=113, 12=109.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
PB10
TrussType
Piggyback
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:502019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-moXQJ3L33sa_x8CRmrBbK6LFBCkoihpMS0zSRszZ0AZ
Scale=1:48.6
0-1-140-1-14T1
T2
T1
B1
ST1ST1ST1 ST1 ST1
T3
B212
3 4 5 6 7 8 9 10
11
12
18 1716 15 14 13
19
20 21 22 23 24
3x6
3x6 3x6
3x4
3x6
3x4
27-2-0
27-2-0
4-5-4
4-5-4
22-8-12
18-3-8
27-2-0
4-5-4
0-4-31-11-22-2-100-1-100-4-30-1-106.0012
PlateOffsets(X,Y)-- [3:0-3-0,Edge], [10:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.22
0.18
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.01
0.01
(loc)
12
12
11
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 70 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 25-2-14.
(lb)-Max Horz2=35(LC 16)
Max UpliftAll uplift 100 lb orless at joint(s) 2, 15, 17, 18, 14, 13, 11
MaxGravAllreactions 250 lb orless at joint(s) except 2=342(LC 39), 15=429(LC 38), 17=432(LC 38),
18=398(LC 38), 14=432(LC 38), 13=398(LC 38), 11=342(LC 39)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-19=-296/73, 11-24=-296/73
WEBS 6-15=-346/113, 5-17=-358/123, 4-18=-298/108, 7-14=-358/123, 9-13=-298/106
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 3-4-3,Interior(1) 3-4-3 to 4-5-4,Exterior(2) 4-5-4 to 26-9-13zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 15, 17, 18, 14,
13, 11.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T01
TrussType
Common
Qty
2
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:522019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-jBfAklNKbTqiBSLquGD3PXQZ60M1AVKfwKSYVkzZ0AX
Scale=1:62.1
T2 T2
B1
W5
W4 W3W4W3
W1
W2
W1
W2
T1 T1
B2
1
2
3
4
5
6
7
8
9
15 14 13 12 11 10
16
17
18 19 20
21
3x6
4x4
3x6
3x6 3x6 3x8
3x5
4x4
3x5
4x4
4x4
3x6
4x4
5-11-4
5-11-4
11-7-0
5-7-12
17-2-12
5-7-12
23-2-0
5-11-4
-1-6-4
1-6-4
5-11-4
5-11-4
11-7-0
5-7-12
17-2-12
5-7-12
23-2-0
5-11-4
24-8-4
1-6-4
1-7-1410-4-21-7-149.0012
PlateOffsets(X,Y)-- [2:0-1-0,0-1-12], [8:0-1-0,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.38
0.32
0.40
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.06
-0.09
0.02
(loc)
10-11
14-15
10
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 123 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W5,W4: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-6-4 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 5-12
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)15=894/0-4-0(min. 0-1-11), 10=894/0-4-0(min. 0-1-11)
Max Horz15=312(LC 15)
Max Uplift15=-144(LC 16), 10=-144(LC 17)
MaxGrav15=1015(LC 2), 10=1015(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-16=-989/651, 3-16=-888/688, 3-4=-771/584, 4-17=-676/599, 17-18=-671/602,
5-18=-669/621, 5-19=-669/621, 19-20=-671/602, 6-20=-676/599, 6-7=-771/584,
7-21=-888/688, 8-21=-989/651, 2-15=-960/635, 8-10=-960/635
BOT CHORD 14-15=-295/323, 13-14=-425/711, 12-13=-425/711, 11-12=-413/711
WEBS 5-12=-598/541, 7-12=-326/296, 3-12=-326/296, 2-14=-373/662, 8-11=-374/662
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-1-6-4 to 1-5-12,Interior(1) 1-5-12 to 11-7-0,Exterior(2) 11-7-0 to 14-7-0
zone;cantileverleft and right exposed ; end verticalleft and right exposed; porchleft and right exposed;C-C formembers and forces
&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
15=144, 10=144.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T01GE
TrussType
Common SupportedGable
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:532019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-BNDZx5NyMnyZocw0SzlIykzjiPk2v0sp9_C62BzZ0AW
Scale=1:65.3
W4
T2 T2
W4
B1
ST6
ST5
ST4
ST3
ST2
ST1
ST5
ST4
ST3
ST2
ST1
W1
W1
W2
T1 T1
B2
1
2
3
4
5
6 7
8
9
10
11
12
13
14
15
16
17
31 30 29 28 27 26 25 24 23 22 21 20 19 18
38 39
3x4
3x8
3x6
4x6
3x6
3x4
3x8
3x6
2x42x4 2x4
2x4 2x4
2x4
2x4
3-8-84-0-011-7-0
11-7-0
23-2-0
11-7-0
-1-6-4
1-6-4
11-7-0
11-7-0
23-2-0
11-7-0
24-8-4
1-6-4
1-7-1410-4-21-7-149.0012
PlateOffsets(X,Y)-- [18:Edge,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-R
0.39
0.21
0.19
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.04
0.01
(loc)
17
17
18
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 144 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud*Except*
ST5: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 8-25, 10-23
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 23-2-0.
(lb)-Max Horz31=-312(LC 14)
Max UpliftAll uplift 100 lb orless at joint(s) 28, 29, 21, 20 except 31=-152(LC 12),
18=-136(LC 13), 26=-142(LC 16), 30=-308(LC 16), 22=-144(LC 17), 19=-303(LC
17)
MaxGravAllreactions 250 lb orless at joint(s) 25, 26, 28, 29, 23, 22, 21, 20, 24
except 31=356(LC 31), 18=343(LC 30), 30=274(LC 14), 19=262(LC 15)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-31=-267/108, 2-3=-255/176, 16-18=-258/97
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-C Corner(3)-1-6-4 to 1-7-0,Exterior(2) 1-7-0 to 11-7-0, Corner(3) 11-7-0 to 14-7-0zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)Truss to be fullysheathed from one face orsecurely braced againstlateralmovement(i.e. diagonalweb).
10)Vertical gablestudsspaced at 2-0-0 oc and horizontal gablestudsspaced at 4-3-8 oc.
11)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
12)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 28, 29, 21, 20
except(jt=lb) 31=152, 18=136, 26=142, 30=308, 22=144, 19=303.
13)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T02
TrussType
Common
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:542019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-fZnx9QOa754QQmVC?hGXUyVvgp2ZePnyNexfadzZ0AV
Scale=1:62.1
T1
T2
B1
W3 W4
W5
W4 W3
W1
W2
W7
W6
T3
B2
1
2
3
4
5
6
7
13 12 11 10 9 8
14
15
16 17
18
193x6
4x4
3x6
3x6 3x6
3x5
3x4
3x8
3x5
4x4 3x6
4x4
5-5-4
5-5-4
11-1-0
5-7-12
16-8-12
5-7-12
22-8-0
5-11-4
5-5-4
5-5-4
11-1-0
5-7-12
16-8-12
5-7-12
22-8-0
5-11-4
24-2-4
1-6-4
2-0-610-4-21-7-149.0012
PlateOffsets(X,Y)-- [6:0-1-0,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.38
0.32
0.40
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.06
-0.09
0.02
(loc)
8-9
8-9
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 120 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W4,W5: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-7-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 3-10
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)13=789/0-6-0(min. 0-1-8), 8=880/0-4-0(min. 0-1-10)
Max Horz13=-306(LC 12)
Max Uplift13=-101(LC 16), 8=-142(LC 17)
MaxGrav13=891(LC 2), 8=999(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-14=-909/617, 2-14=-737/638, 2-15=-749/572, 15-16=-649/589, 3-16=-648/608,
3-17=-645/605, 17-18=-648/586, 4-18=-654/584, 4-5=-748/569, 5-19=-868/676,
6-19=-969/638, 1-13=-842/566, 6-8=-944/625
BOT CHORD 12-13=-275/300, 11-12=-387/662, 10-11=-387/662, 9-10=-403/695
WEBS 2-10=-287/259, 3-10=-584/516, 5-10=-329/300, 1-12=-422/651, 6-9=-363/645
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 11-1-0,Exterior(2) 11-1-0 to 14-1-0
zone;cantileverleft and right exposed ; end verticalleft and right exposed; porchleft and right exposed;C-C formembers and forces
&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
13=101, 8=142.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T03
TrussType
PiggybackBase
Qty
4
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:562019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-byvha6QqfiK8f3fb76I?aNa71djx6H_FryQmeVzZ0AT
Scale=1:69.3
T1
T2
T3
B1
W3
W4
W5
W6
W3
W7
W8
W1
W2
W10
W9
T4
B2
1
2 3 4
5
6
78
15 14 13 12 11 10 9
16 17 18
19
20
21
22
5x6 5x6
3x10MT18H
1.5x4 3x63x4
3x8
1.5x4
3x4
3x5
4x4
3x5
3x4
5x6
3-8-8
3-8-8
6-3-0
2-6-8
9-6-8
3-3-8
16-3-8
6-9-0
23-4-0
7-0-8
3-8-8
3-8-8
6-3-0
2-6-8
9-6-8
3-3-8
16-3-8
6-9-0
23-4-0
7-0-8
24-2-4
0-10-4
8-8-1011-6-01-1-1411-6-09.0012
PlateOffsets(X,Y)-- [2:0-3-12,0-1-12], [4:0-4-0,0-1-12], [7:0-2-12,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.77
0.39
0.55
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.06
-0.14
0.01
(loc)
9-10
9-10
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 171 lb FT= 20%
GRIP
185/144
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W8,W10,W9: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-10-8 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
6-0-0 oc bracing: 13-14.
WEBS 1 Row at midpt 2-13, 3-13, 4-13, 6-11, 1-15, 1-14
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)15=117/0-6-0(min. 0-1-8), 13=1006/0-6-0(min. 0-2-0), 9=617/0-6-0(min. 0-1-8)
Max Horz15=-369(LC 17)
Max Uplift15=-64(LC 12), 13=-140(LC 17), 9=-62(LC 17)
MaxGrav15=188(LC 41), 13=1203(LC 39), 9=792(LC 39)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 6-20=-403/73, 6-21=-610/61, 21-22=-757/34, 7-22=-858/25, 7-9=-729/121
BOT CHORD 14-15=-288/369, 13-14=-289/362, 12-13=-154/293, 11-12=-154/293, 10-11=0/606,
9-10=-122/285
WEBS 2-13=-341/87, 3-13=-313/104, 4-13=-816/214, 4-11=-117/530, 6-11=-638/271,
6-10=0/269, 7-10=0/417
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 3-8-8,Exterior(2) 3-8-8 to 13-9-7,
Interior(1) 13-9-7 to 24-2-4zone;cantileverright exposed ; end verticalright exposed; porchleft exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 15, 9 except
(jt=lb) 13=140.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T03GE
TrussType
GABLECOMMON
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:572019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-38T3nSQSQ0T?HDEnhppE6a7In13ArkEO3cAJByzZ0AS
Scale=1:70.3
T1
T2
T3
B1
W3
W4
W5
W6
W3
W7
W8
W1
W2
W10
W9
ST6
ST4
ST5
ST3
ST1
ST2
ST7
ST8 ST9
T4
B2
1
2 3 4
5
6
78
15 14 13 12 11 10 9
30 31 32
33
34
35
36
5x6 5x6
3x10MT18H
1.5x4 3x63x4
3x8
1.5x4
3x4
3x5
4x4
4x8
3x4
5x6
3x4
3x4
3x4
3x4
3-8-8
3-8-8
6-3-0
2-6-8
9-6-8
3-3-8
16-3-8
6-9-0
23-4-0
7-0-8
3-8-8
3-8-8
6-3-0
2-6-8
9-6-8
3-3-8
16-3-8
6-9-0
23-4-0
7-0-8
24-2-4
0-10-4
8-8-1011-6-01-1-1411-6-09.0012
PlateOffsets(X,Y)-- [1:0-0-8,0-0-0], [2:0-3-12,0-1-12], [4:0-4-0,0-1-12], [7:0-2-12,0-1-8], [23:0-2-0,0-2-5]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.77
0.39
0.55
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.06
-0.14
0.01
(loc)
9-10
9-10
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 236 lb FT= 20%
GRIP
185/144
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W8,W10,W9: 2x4SPFStud
OTHERS 2x4SPFStud*Except*
ST6,ST3,ST2,ST8: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-10-8 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
6-0-0 oc bracing: 13-14.
WEBS 1 Row at midpt 2-13, 3-13, 4-13, 6-11, 1-15, 1-14
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)15=117/0-6-0(min. 0-1-8), 13=1006/0-6-0(min. 0-2-0), 9=617/0-6-0(min. 0-1-8)
Max Horz15=-369(LC 17)
Max Uplift15=-64(LC 12), 13=-140(LC 17), 9=-62(LC 17)
MaxGrav15=188(LC 41), 13=1203(LC 39), 9=792(LC 39)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 6-34=-403/73, 6-35=-610/61, 35-36=-757/34, 7-36=-858/25, 7-9=-729/121
BOT CHORD 14-15=-288/369, 13-14=-289/362, 12-13=-154/293, 11-12=-154/293, 10-11=0/606,
9-10=-122/285
WEBS 2-13=-341/87, 3-13=-313/104, 4-13=-816/214, 4-11=-117/530, 6-11=-638/271,
6-10=0/269, 7-10=0/417
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 3-8-8,Exterior(2) 3-8-8 to 13-9-7,
Interior(1) 13-9-7 to 24-2-4zone;cantileverright exposed ; end verticalright exposed; porchleft exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)Provide adequate drainage to preventwater ponding.
8)All plates areMT20 plates unless otherwiseindicated.
9)All plates are 2x4MT20 unless otherwiseindicated.
10)Gablestudsspaced at 2-0-0 oc.
11)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
12)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 15, 9 except
(jt=lb) 13=140.Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T03GE
TrussType
GABLECOMMON
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:572019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-38T3nSQSQ0T?HDEnhppE6a7In13ArkEO3cAJByzZ0AS
NOTES-
13)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T04
TrussType
PiggybackBaseGirder
Qty
1
Ply
2
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:592019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-0XaqC8SjydjiWXOAoEsiB?CcwqkOJY7hXwfQFqzZ0AQ
Scale=1:70.6
W1
T1
T2
B1
W2 W3 W4
W5
W6 W7
W9W8
T3
B2
1 2
3
4
5
67
13 12 11 10 9 8
14
15 16 17 18 19 20
3x10MT18H
6x6 4x4
3x6
6x810x10
5x6
10x10
4x6
8x8 5x6
4x8
3-6-8
3-6-8
8-0-8
4-6-0
12-6-8
4-6-0
17-4-0
4-9-8
3-6-8
3-6-8
8-0-8
4-6-0
12-6-8
4-6-0
17-4-0
4-9-8
18-2-4
0-10-4
11-6-01-1-1411-6-09.0012
PlateOffsets(X,Y)-- [1:0-2-0,0-2-4], [3:0-1-4,0-2-0], [6:0-3-0,0-1-12], [9:0-3-8,0-5-4], [10:0-3-8,0-6-4], [12:0-3-12,0-5-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.92
0.41
0.91
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.12
-0.27
0.02
(loc)
9-10
9-10
8
l/defl
>999
>764
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 310 lb FT= 20%
GRIP
185/144
244/190
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x8SP 2400F 2.0E
WEBS 2x4 HF/SPF No.2 *Except*
W1: 2x4SP 2250F 1.9E,W6,W7: 2x4SPFStud
W9: 2x4SP 2400F 2.0E
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-9-10 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 1-13, 3-12
REACTIONS.(lb/size)13=8435/0-6-0(min. 0-3-9), 8=5886/0-6-0(min. 0-1-8)
Max Horz13=-434(LC 50)
Max Uplift13=-1654(LC 13), 8=-1691(LC 13)
MaxGrav13=8562(LC 32), 8=6083(LC 32)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-13=-6747/1445, 1-2=-1981/424, 2-3=-2618/468, 3-4=-5816/1273, 4-5=-6023/1255,
5-14=-7820/2195, 6-14=-7943/2165, 6-8=-5815/1628
BOT CHORD 13-15=-182/438, 15-16=-182/438, 12-16=-182/438, 12-17=-929/4755, 17-18=-929/4755,
11-18=-929/4755, 10-11=-929/4755, 10-19=-1650/6278, 19-20=-1650/6278,
9-20=-1650/6278, 8-9=-325/955
WEBS 1-12=-1493/6979, 2-12=-270/1304, 3-12=-5370/1535, 3-10=-1645/6157, 5-10=-2156/1193,
5-9=-1257/2459, 6-9=-1428/5405
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-7-0 oc.
Bottomchordsconnected as follows: 2x8- 2 rowsstaggered at 0-4-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverright exposed ; end verticalright exposed; Lumber DOL=1.60 plate grip DOL=1.60
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)Provide adequate drainage to preventwater ponding.
8)All plates areMT20 plates unless otherwiseindicated.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Bearing at joint(s) 8 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T04
TrussType
PiggybackBaseGirder
Qty
1
Ply
2
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:34:592019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-0XaqC8SjydjiWXOAoEsiB?CcwqkOJY7hXwfQFqzZ0AQ
NOTES-
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 13=1654, 8=1691.
12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
13) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 1708 lb down and 205 lb up at 0-6-4, 1702 lb down and 186 lb up at
2-6-4, 1721 lb down and 238 lb up at 4-6-4, 1776 lb down and 287 lb up at 6-6-4, 1854 lb down and 337 lb up at 8-6-4, and 1719 lb down and 396 lb up at 10-6-4, and
2747lb down and 1500 lb up at 12-7-0 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-61, 2-6=-51, 6-7=-51, 8-13=-20
Concentrated Loads(lb)
Vert: 9=-2604(B) 15=-1694(B) 16=-1660(B) 17=-1721(B) 18=-1776(B) 19=-1854(B) 20=-1719(B)
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T05GE
TrussType
HalfHip Supported
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:002019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-Uj8CPUTLjxrZ8hyMMxNxkDlydE9q2CPrmZO_nHzZ0AP
Scale=1:15.1
0-1-14W1
T1
T2
B1
ST2ST1
1 2 3
4
5
8 7 6
9
10
11
1.5x4
1.5x4
4x4
2x41.5x41.5x4
1.5x4
6-5-12
6-5-12
3-0-0
3-0-0
6-5-12
3-5-12
7-8-8
1-2-12
2-0-02-1-140-5-02-0-06.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.22
0.07
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.01
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 22 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 6-5-12.
(lb)-Max Horz8=-80(LC 12)
Max UpliftAll uplift 100 lb orless at joint(s) 4, 6, 7
MaxGravAllreactions 250 lb orless at joint(s) 8, 6, 7 except 4=299(LC 36)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-C Corner(3) 0-1-12 to 6-0-0,Exterior(2) 6-0-0 to 7-8-8zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)Provide adequate drainage to preventwater ponding.
8)Gablerequirescontinuous bottomchord bearing.
9)Gablestudsspaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 4, 6, 7.
12)Beveled plate orshimrequired to provide full bearingsurfacewith trusschord at joint(s) 4.
13)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T06
TrussType
Jack-ClosedGirder
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:022019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-Q6GyqAUbFY5HN_6lTMPPpeqDS2k1W?h7Dtt4s9zZ0AN
Scale=1:40.2
0-1-14W1
T1
T2B1
B3
B2
W2
W4
W3
W5 W6 W5 W6 W7
W8 W9
B4
1 2 3 4 5
6
7
8
17
16
15 14 13
12
11 10 9
21 22 23 24 25 26 27
28
29 30 31 32 33 34
6x6
1.5x4 6x6
4x4
2x4 3x45x84x8
3x4 3x4
3x4 3x4
3x4
1.5x4
3x5
1-0-0
1-0-0
5-5-8
4-5-8
10-0-12
4-7-4
14-6-4
4-5-8
17-5-4
2-11-0
21-0-0
3-6-12
1-0-0
1-0-0
5-5-8
4-5-8
10-0-12
4-7-4
14-6-4
4-5-8
17-5-4
2-11-0
21-0-0
3-6-12
23-2-12
2-2-12
2-6-03-7-140-5-01-0-06.0012
PlateOffsets(X,Y)-- [7:0-0-15,0-1-8], [16:0-6-0,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.52
0.54
0.54
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.09
-0.15
0.04
(loc)
10-11
10-11
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 98 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2 *Except*
B3: 2x4SPFStud
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-0-8 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-5-10 oc bracing.Except:
10-0-0 oc bracing: 14-16
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)17=838/0-6-0(min. 0-1-14), 7=908/0-6-0(min. 0-1-12)
Max Horz17=-135(LC 8)
Max Uplift17=-557(LC 8), 7=-408(LC 13)
MaxGrav17=1150(LC 71), 7=1061(LC 32)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-21=-537/277, 21-22=-537/277, 3-22=-537/277, 3-23=-1427/709, 23-24=-1427/709,
4-24=-1427/709, 4-25=-1776/872, 25-26=-1775/871, 26-27=-1773/872, 5-27=-1773/872,
5-6=-1497/705, 6-28=-1467/654, 7-28=-1501/639
BOT CHORD 16-17=-200/582, 2-16=-344/770, 13-31=-772/1814, 12-31=-772/1814, 12-32=-772/1814,
11-32=-772/1814, 11-33=-552/1380, 33-34=-552/1380, 10-34=-552/1380, 9-10=-505/1335,
7-9=-505/1335
WEBS 2-17=-1157/584, 13-16=-586/1354, 3-16=-994/520, 4-13=-426/198, 5-11=-303/551
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
17=557, 7=408.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T06
TrussType
Jack-ClosedGirder
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:022019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-Q6GyqAUbFY5HN_6lTMPPpeqDS2k1W?h7Dtt4s9zZ0AN
NOTES-
10) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 85 lb down and 68 lb up at 1-0-12, 84 lb down and 69 lb up at 2-5-8,
84lb down and 69 lb up at 4-5-8, 84 lb down and 69 lb up at 6-5-8, 84 lb down and 69 lb up at 8-5-8, 84 lb down and 69 lb up at 10-5-8, and 84 lb down and 69 lb up at
12-5-8, and 77 lb down and 69 lb up at 14-6-4 on top chord, and 39 lb down and 39 lb up at 1-1-12, 39 lb down and 39 lb up at 2-5-8, 39 lb down and 39 lb up at 4-5-8,
39lb down and 39 lb up at 6-5-8, 39 lb down and 39 lb up at 8-5-8, 39 lb down and 39 lb up at 10-5-8, and 39 lb down and 39 lb up at 12-5-8, and 39 lb down and 39 lb
up at 14-5-8 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-5=-61, 5-8=-51, 16-17=-20, 14-15=-20, 14-18=-20
Concentrated Loads(lb)
Vert: 16=0(B) 10=0(B) 29=0(B) 30=0(B) 31=0(B) 32=0(B) 33=0(B) 34=0(B)
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T07
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:032019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-uIqL2VVD?sD8?8hx14weMrNN9R2XFQUHSXdeObzZ0AM
Scale=1:43.3
0-1-14W1
T1
T2
B1
B3
B2
W2
W4
W3
W5
W6
W7
W8 W9
W10 W11B4
1 2 3 4
5
6
7
8
17
16
15 14 13
12
11 10 9
21 22 23
24
25
3x4
1.5x4 6x6
4x6
3x4 3x65x8
4x10
3x4
3x5
3x4
4x4
3x4
1.5x4
5x6
1-0-0
1-0-0
6-3-2
5-3-2
11-6-4
5-3-2
15-7-2
4-0-14
19-8-0
4-0-14
21-0-0
1-4-0
1-0-0
1-0-0
6-3-2
5-3-2
11-6-4
5-3-2
15-7-2
4-0-14
19-8-0
4-0-14
21-0-0
1-4-0
23-2-12
2-2-12
4-0-05-1-140-5-01-0-05-0-06.0012
PlateOffsets(X,Y)-- [7:Edge,0-1-1], [16:0-7-0,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.59
0.65
0.69
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.18
0.06
(loc)
11
11-13
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 118 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2 *Except*
T2: 2x4SP 2400F 2.0E
BOT CHORD2x4 HF/SPF No.2 *Except*
B3: 2x4SPFStud,B4: 2x4SP 2400F 2.0E
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-9-2 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 9-10-4 oc bracing.Except:
10-0-0 oc bracing: 14-16
WEBS 1 Row at midpt 3-16, 4-13
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)17=1348/0-6-0(min. 0-2-7), 7=2229/0-6-0(min. 0-2-0)
Max Horz17=-197(LC 12)
Max Uplift17=-253(LC 12), 7=-448(LC 17)
MaxGrav17=1498(LC 35), 7=2416(LC 36)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-21=-386/127, 3-21=-386/127, 3-22=-1582/363, 22-23=-1579/363, 4-23=-1578/363,
4-24=-2377/555, 5-24=-2626/592, 5-6=-3783/828, 6-25=-3670/770, 7-25=-3690/767
BOT CHORD 16-17=-4/346, 2-16=-163/1046, 12-13=-330/2116, 11-12=-330/2116, 10-11=-632/3197,
9-10=-653/3317, 7-9=-653/3317
WEBS 2-17=-1423/314, 13-16=-197/1423, 3-16=-1462/374, 3-13=-72/572, 4-13=-998/249,
4-11=-156/913, 5-11=-1419/365, 6-9=-489/193
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 11-6-4,Exterior(2) 11-6-4 to 15-7-2
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
17=253, 7=448.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T07
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:042019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-MUOjFrWrm9L?dIG7bnRtu3wYvrOm_tkQgBMBw2zZ0AL
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-23=-61, 6-8=-51, 16-17=-20, 14-15=-20, 14-18=-20
Trapezoidal Loads(plf)
Vert: 23=-231-to-4=-238, 4=-228-to-6=-270
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T08
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:052019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-qhx5TBXUXTTsFSrJ8Vy6RGSdHFg9jGeavr6kTUzZ0AK
Scale=1:52.1
0-1-14W1
T1
T2
B1
B3
B2
W2
W4
W3
W5
W6
W7
W8
W9
W10 W11
T3
B4 HW2
1 2 3 4
5
6
7
8
9
18
17
16 15 14
13
12 11 10
22 23
24 25
26
3x5
2x4 6x6
3x6
4x6
2x4
3x64x8
4x10
3x4
4x6
3x4
4x4
3x4
1.5x4
6x6
1-0-0
1-0-0
4-9-2
3-9-2
8-6-4
3-9-2
14-1-2
5-6-14
19-8-0
5-6-14
21-0-0
1-4-0
1-0-0
1-0-0
4-9-2
3-9-2
8-6-4
3-9-2
14-1-2
5-6-14
19-8-0
5-6-14
21-0-0
1-4-0
23-2-12
2-2-12
5-6-06-7-140-5-01-0-06-6-06.0012
PlateOffsets(X,Y)-- [8:0-2-0,Edge], [17:0-7-4,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.99
0.90
0.91
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.10
-0.26
0.06
(loc)
10-11
10-11
8
l/defl
>999
>962
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 126 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2 *Except*
T2: 2x4SPF 1650F 1.5E,T3: 2x4SP 2400F 2.0E
BOT CHORD2x4 HF/SPF No.2 *Except*
B3: 2x4SPFStud,B4: 2x4SPF 2100F 1.8E
WEBS 2x4SPFStud
WEDGE
Right: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied, except end verticals.
BOT CHORD Rigidceiling directly applied or 9-6-2 oc bracing.Except:
10-0-0 oc bracing: 15-17
WEBS 1 Row at midpt 4-14, 6-12
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)18=1331/0-6-0(min. 0-2-5), 8=2216/0-6-0(min. 0-3-1)
Max Horz18=-259(LC 12)
Max Uplift18=-241(LC 12), 8=-467(LC 17)
MaxGrav18=1404(LC 35), 8=2388(LC 36)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-22=-272/133, 22-23=-272/133, 3-23=-272/133, 3-4=-888/275, 4-24=-1463/355,
24-25=-1513/352, 5-25=-1555/356, 5-6=-1921/396, 6-7=-3730/720, 7-26=-4028/747,
8-26=-4053/744
BOT CHORD 17-18=-50/286, 2-17=-195/1047, 13-14=-98/1375, 12-13=-98/1375, 11-12=-512/3050,
10-11=-665/3749, 8-10=-665/3749
WEBS 2-18=-1239/310, 14-17=-66/819, 3-17=-1111/354, 3-14=-204/785, 4-14=-1058/271,
4-12=-210/1161, 6-12=-1972/490, 6-11=0/337, 7-11=-730/173, 7-10=-588/244
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 8-6-4,Exterior(2) 8-6-4 to 12-9-2
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
18=241, 8=467.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)StandardContinued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T08
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:052019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-qhx5TBXUXTTsFSrJ8Vy6RGSdHFg9jGeavr6kTUzZ0AK
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-4=-61, 4-24=-51, 7-9=-51, 17-18=-20, 15-16=-20, 15-19=-20
Trapezoidal Loads(plf)
Vert: 24=-221-to-7=-270
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T09
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:062019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-ItVTgXX6InbjscQWiCULzU?rwf13SpSj8VrI?wzZ0AJ
Scale=1:58.6
0-1-14W1
T1
T2
B1
B3
B2
W2
W4
W3
W5 W6
W7 W8
W9
W10 W11
T3
B4
1 2 3
4
5
6
7
8
918
17
16 15 14
13
12 11 10
22 23 24 25
26
27
4x4
3x4 6x6
4x8
3x8
2x4
3x64x8
4x10
3x8
4x4
3x4
4x4
3x4
1.5x4
5x6
1-0-0
1-0-0
5-6-4
4-6-4
10-2-13
4-8-9
14-11-7
4-8-9
19-8-0
4-8-9
21-0-0
1-4-0
1-0-0
1-0-0
5-6-4
4-6-4
10-2-13
4-8-9
14-11-7
4-8-9
19-8-0
4-8-9
21-0-0
1-4-0
23-2-12
2-2-12
7-0-08-1-140-5-01-0-08-0-06.0012
PlateOffsets(X,Y)-- [5:0-4-0,Edge], [8:0-0-12,Edge], [17:0-7-8,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.81
0.79
0.55
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.09
-0.23
0.05
(loc)
11
10-11
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 129 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2 *Except*
T3: 2x4SPF 2100F 1.8E
BOT CHORD2x4 HF/SPF No.2 *Except*
B4: 2x4SPF 2100F 1.8E
WEBS 2x4SPFStud*Except*
W3,W5: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-9-3 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.Except:
10-0-0 oc bracing: 15-17
WEBS 1 Row at midpt 2-18, 3-17, 4-14, 6-12
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)18=1300/0-6-0(min. 0-2-3), 8=2195/0-6-0(min. 0-3-0)
Max Horz18=-322(LC 12)
Max Uplift18=-225(LC 12), 8=-473(LC 17)
MaxGrav18=1343(LC 2), 8=2338(LC 36)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 3-24=-935/284, 24-25=-1058/262, 4-25=-1077/262, 4-5=-2118/417, 5-6=-2423/448,
6-26=-3603/656, 7-26=-3873/690, 7-27=-3882/684, 8-27=-3896/681
BOT CHORD 17-18=-116/330, 2-17=-211/1066, 13-14=-159/1895, 12-13=-159/1895, 11-12=-479/3263,
10-11=-584/3546, 8-10=-584/3546
WEBS 2-18=-1204/341, 14-17=-14/754, 3-17=-1193/380, 3-14=-274/1200, 4-14=-1627/393,
4-12=-155/995, 6-12=-1655/384, 6-11=0/273, 7-11=-343/121, 7-10=-513/215
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 5-6-4,Exterior(2) 5-6-4 to 9-9-2zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
18=225, 8=473.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T09
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:062019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-ItVTgXX6InbjscQWiCULzU?rwf13SpSj8VrI?wzZ0AJ
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-3=-61, 3-4=-51, 7-9=-51, 17-18=-20, 15-16=-20, 15-19=-20
Trapezoidal Loads(plf)
Vert: 4=-221-to-7=-270
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T10
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:072019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-n33rttYk34jaUl?iGv?aWhY_V3LSBENtN9brXNzZ0AI
Scale=1:65.5
0-1-14W1
T1
T2
B1
B3
B2
W2
W4
W3
W5 W6
W7 W8
W9
W10 W11
T3
B4 HW2
1 2 3
4
5
6
7
8
918
17
16 1514 13
12
11 10
22
23
24
25
3x4
1.5x4 6x6
3x10MT18H
4x6
1.5x4
4x6
4x8
4x8
3x8
4x6
3x4
4x4
3x4
1.5x4
6x6
1-0-0
1-0-0
2-6-4
1-6-4
8-2-13
5-8-9
13-11-7
5-8-9
19-8-0
5-8-9
21-0-0
1-4-0
1-0-0
1-0-0
2-6-4
1-6-4
8-2-13
5-8-9
13-11-7
5-8-9
19-8-0
5-8-9
21-0-0
1-4-0
23-2-12
2-2-12
8-6-09-7-140-5-01-0-09-6-06.0012
PlateOffsets(X,Y)-- [8:0-2-4,Edge], [17:0-6-4,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.95
0.91
0.70
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.11
-0.28
0.04
(loc)
10-11
10-11
8
l/defl
>999
>887
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 145 lb FT= 20%
GRIP
185/144
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2 *Except*
T3: 2x4SP 2250F 1.9E
BOT CHORD2x4 HF/SPF No.2 *Except*
B4: 2x4SPF 2100F 1.8E
WEBS 2x4SPFStud*Except*
W1,W2,W3,W5,W6: 2x4 HF/SPF No.2
WEDGE
Right: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-8-10 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 8-11-7 oc bracing.Except:
10-0-0 oc bracing: 15-17
WEBS 1 Row at midpt 1-18, 2-18, 3-17, 4-14, 6-13
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)18=1286/0-6-0(min. 0-2-6), 8=2201/0-6-0(min. 0-2-15)
Max Horz18=-411(LC 17)
Max Uplift18=-297(LC 17), 8=-442(LC 17)
MaxGrav18=1448(LC 36), 8=2304(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 3-22=-426/102, 4-22=-559/75, 4-23=-1527/253, 5-23=-1634/253, 5-6=-1972/286,
6-24=-3019/507, 7-24=-3651/607, 7-25=-3870/686, 8-25=-3887/683
BOT CHORD 17-18=-77/386, 2-17=-305/1308, 13-14=-27/1461, 12-13=-403/3006, 11-12=-403/3006,
10-11=-628/3568, 8-10=-628/3568
WEBS 2-18=-1208/298, 14-17=0/505, 3-17=-1200/489, 3-14=-425/1112, 4-14=-1656/413,
4-13=-177/1096, 6-13=-1837/455, 6-11=0/344, 7-11=-703/227, 7-10=-601/251
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 6-9-2,Interior(1) 6-9-2 to 23-2-12zone;cantileverright exposed ;
endverticalright exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
18=297, 8=442.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S)StandardContinued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T10
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:082019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-FGdE5DZMqOrR6vauqdWp3v49FShhwhd0bpKP4pzZ0AH
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-3=-61, 3-23=-51, 7-9=-51, 17-18=-20, 15-16=-20, 15-19=-20
Trapezoidal Loads(plf)
Vert: 23=-221-to-7=-270
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T11
TrussType
Jack-Closed
Qty
4
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:092019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-jSBcIZa_bizIj385NK12b6dOLs2uf4p9qT4ycFzZ0AG
Scale=1:68.6
W1
T1
B1
B3
B2
W2
W4
W3
W5 W6
W7
W8 W9
W10 W11
T2
B4 HW2
1 2
3
4
5
6
7
817
16
15 14 13
12
11 10 9
21
22
23
24
3x4
1.5x4 3x8
2x4
3x6
4x8
4x10
3x8
6x8
4x4
3x4
4x4
3x4
1.5x4
6x6
1-0-0
1-0-0
5-8-0
4-8-0
10-9-8
5-1-8
15-0-0
4-2-9
19-8-0
4-8-0
21-0-0
1-4-0
1-0-0
1-0-0
5-8-0
4-8-0
10-9-8
5-1-8
15-0-0
4-2-9
19-8-0
4-8-0
21-0-0
1-4-0
23-2-12
2-2-12
9-11-010-11-00-5-01-0-06.0012
PlateOffsets(X,Y)-- [4:0-3-0,0-3-4], [7:0-2-0,Edge], [16:0-8-0,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.67
0.84
0.89
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.09
-0.24
0.05
(loc)
9-10
9-10
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 144 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2 *Except*
T2: 2x4SP 2400F 2.0E
BOT CHORD2x4 HF/SPF No.2 *Except*
B4: 2x4SPF 2100F 1.8E
WEBS 2x4SPFStud*Except*
W1,W2,W3,W5: 2x4 HF/SPF No.2
WEDGE
Right: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-3-14 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 9-10-6 oc bracing.Except:
10-0-0 oc bracing: 14-16
WEBS 1 Row at midpt 1-17, 2-17, 3-16, 4-13
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)17=1265/0-6-0(min. 0-2-6), 7=2199/0-6-0(min. 0-3-3)
Max Horz17=-464(LC 17)
Max Uplift17=-375(LC 17), 7=-461(LC 17)
MaxGrav17=1427(LC 2), 7=2490(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 3-23=-992/151, 4-23=-1137/138, 4-5=-2595/405, 5-6=-4011/672, 6-24=-4060/704,
7-24=-4080/701
BOT CHORD 16-17=-107/436, 2-16=-239/1103, 12-13=-161/2102, 11-12=-161/2102, 10-11=-470/3329,
9-10=-620/3691, 7-9=-620/3691
WEBS 2-17=-1229/357, 13-16=0/723, 3-16=-1317/443, 3-13=-285/1150, 4-13=-1710/433,
4-11=-174/1008, 5-11=-1565/392, 5-10=0/271, 6-10=-367/151, 6-9=-560/207
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 4-4-10,Interior(1) 4-4-10 to 23-2-12zone;cantileverright
exposed ; end verticalright exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
17=375, 7=461.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T11
TrussType
Jack-Closed
Qty
4
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:092019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-jSBcIZa_bizIj385NK12b6dOLs2uf4p9qT4ycFzZ0AG
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-23=-51, 6-8=-51, 16-17=-20, 14-15=-20, 14-18=-20
Trapezoidal Loads(plf)
Vert: 23=-221-to-6=-270
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T12
TrussType
JACK-CLOSED
Qty
3
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:102019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-Bel_WvbcM?58LDjHx2YH8KAc5GVdObDJ37pV8hzZ0AF
Scale=1:67.2
W1
T1
B1
B3
B2
W2
W4
W3
W5
W6 W7
T2
B4
1 2
3
4
5
6714
13
12 11
10
9 8
18 19
20
3x4
1.5x4
3x6
3x6
4x4
3x6 4x8
4x10
3x4
3x4
1.5x4
3x5
1-0-0
1-0-0
7-7-12
6-7-12
14-0-13
6-5-1
21-0-0
6-11-3
1-0-0
1-0-0
7-7-12
6-7-12
14-0-13
6-5-1
21-0-0
6-11-3
22-2-12
1-2-12
9-11-010-11-00-5-01-0-06.0012
PlateOffsets(X,Y)-- [13:0-7-8,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.48
0.43
0.63
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.05
-0.15
0.03
(loc)
8-17
8-17
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 123 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W1,W2,W3: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-6-13 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.Except:
10-0-0 oc bracing: 11-13
WEBS 1 Row at midpt 2-14, 3-13
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)14=744/0-6-0(min. 0-1-8), 6=808/0-6-0(min. 0-1-8)
Max Horz14=-447(LC 17)
Max Uplift14=-252(LC 17), 6=-119(LC 17)
MaxGrav14=880(LC 24), 6=916(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 3-4=-638/59, 4-5=-793/28, 5-20=-1262/108, 6-20=-1346/76
BOT CHORD 13-14=-120/419, 2-13=-85/487, 8-9=0/1129, 6-8=0/1129
WEBS 2-14=-956/350, 9-13=0/456, 3-13=-715/295, 3-9=-45/432, 5-9=-570/204, 5-8=0/262
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 4-4-11,Interior(1) 4-4-11 to 22-2-12zone;cantileverright
exposed ; end verticalright exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
14=252, 6=119.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T13
TrussType
Jack-Closed
Qty
3
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:112019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-frJMjEbE7JD?zNITVl3WgXiokgqc72sSHnZ3g8zZ0AE
Scale=1:70.4
W1
T1
B1
B3
B2
W2
W4
W3
W5
W6 W7
T2
B4
1
2
3
4
5
6
714
13
12 11
10
9 8
18 19
20
3x4
1.5x4
3x4
3x6
3x4 3x4 4x8
4x8
3x4
3x4
1.5x4 3x5
2-0-0
2-0-0
8-6-6
6-6-6
15-0-13
6-6-6
22-0-0
6-11-3
2-0-0
2-0-0
8-6-6
6-6-6
15-0-13
6-6-6
22-0-0
6-11-3
23-2-12
1-2-12
10-5-011-5-00-5-01-0-06.0012
PlateOffsets(X,Y)-- [13:0-5-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.42
0.44
0.60
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.05
-0.15
0.03
(loc)
8-17
8-17
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 127 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W4,W5,W7: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-5-1 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.Except:
10-0-0 oc bracing: 11-13
WEBS 1 Row at midpt 2-14, 3-13
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)14=798/0-6-0(min. 0-1-9), 6=844/0-6-0(min. 0-1-9)
Max Horz14=-467(LC 17)
Max Uplift14=-254(LC 17), 6=-121(LC 17)
MaxGrav14=944(LC 24), 6=957(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 3-19=-310/0, 3-4=-717/63, 4-5=-875/31, 5-20=-1353/113, 6-20=-1437/82
BOT CHORD 13-14=-53/413, 2-13=-97/646, 8-9=0/1210, 6-8=0/1210
WEBS 2-14=-948/290, 9-13=0/610, 3-13=-687/294, 3-9=-46/407, 5-9=-579/207, 5-8=0/265
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 4-4-11,Interior(1) 4-4-11 to 23-2-12zone;cantileverright
exposed ; end verticalright exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
14=254, 6=121.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T14
TrussType
FlatGirder
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:132019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-bDQ78wdVfwUjCgSscA6_myo2tTXhbvyll52Al0zZ0AC
Scale:3/16"=1'
W1
T1
W1
B1
W2
W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1
W2
T3T2
B3B2
1 2 3 4 5 6 7 8 9 10
20 19 18 17 16 15 14 13 12 11
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
3738 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
3x10
5x8 4x8 5x8
3x104x86x8
5x6
5x6
4x4
4x8
2x4 4x4
4x4
4x4
5x6
5x6
6x8
4x8
6x8
5-4-2
5-4-2
10-6-7
5-2-6
15-8-13
5-2-6
20-11-3
5-2-6
26-1-9
5-2-6
31-3-14
5-2-6
36-8-0
5-4-2
5-4-2
5-4-2
10-6-7
5-2-6
15-8-13
5-2-6
20-11-3
5-2-6
26-1-9
5-2-6
31-3-14
5-2-6
36-8-0
5-4-2
4-1-2PlateOffsets(X,Y)-- [12:0-3-8,0-3-0], [19:0-3-8,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.76
0.34
0.82
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.38
-0.57
0.09
(loc)
15-16
15-16
11
l/defl
>999
>767
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 248 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x6SP 2400F 2.0E
BOT CHORD2x6SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W2: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-5-11 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-3-15 oc bracing.
WEBS 1 Row at midpt 1-19, 10-12
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)20=2022/0-6-0(min. 0-1-12), 11=2009/0-6-0(min. 0-1-12)
Max Uplift20=-1163(LC 8), 11=-1146(LC 8)
MaxGrav20=2142(LC 2), 11=2126(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-20=-2037/1156, 1-21=-2613/1402, 21-22=-2613/1402, 22-23=-2613/1402,
2-23=-2613/1402, 2-24=-4294/2301, 24-25=-4294/2301, 25-26=-4294/2301,
3-26=-4294/2301, 3-27=-5136/2750, 4-27=-5136/2750, 4-5=-5136/2750, 5-28=-5136/2750,
28-29=-5136/2750, 29-30=-5136/2750, 6-30=-5136/2750, 6-31=-5141/2753,
31-32=-5141/2753, 7-32=-5141/2753, 7-33=-4290/2298, 8-33=-4290/2298,
8-9=-4290/2298, 9-34=-2608/1396, 34-35=-2608/1396, 35-36=-2608/1396,
10-36=-2608/1396, 10-11=-2026/1142
BOT CHORD 19-40=-1402/2613, 18-40=-1402/2613, 18-41=-1402/2613, 41-42=-1402/2613,
17-42=-1402/2613, 17-43=-2301/4294, 43-44=-2301/4294, 16-44=-2301/4294,
16-45=-2753/5141, 45-46=-2753/5141, 46-47=-2753/5141, 15-47=-2753/5141,
15-48=-2298/4290, 14-48=-2298/4290, 14-49=-2298/4290, 13-49=-2298/4290,
13-50=-1396/2608, 50-51=-1396/2608, 12-51=-1396/2608
WEBS 1-19=-1693/3157, 2-19=-1639/1003, 2-17=-1098/2051, 3-17=-1007/644, 3-16=-547/1029,
5-16=-423/335, 6-15=-426/337, 7-15=-556/1039, 7-13=-1011/648, 9-13=-1101/2053,
9-12=-1637/999, 10-12=-1687/3151
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
3) Unbalancedsnowloads have been considered for this design.
4)Provide adequate drainage to preventwater ponding.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
20=1163, 11=1146.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T14
TrussType
FlatGirder
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:132019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-bDQ78wdVfwUjCgSscA6_myo2tTXhbvyll52Al0zZ0AC
NOTES-
8) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 107 lb down and 92 lb up at 0-6-12, 112 lb down and 92 lb up at 2-1-4
, 112 lb down and 92 lb up at 4-1-4, 112 lb down and 92 lb up at 6-1-4, 112 lb down and 92 lb up at 8-1-4, 112 lb down and 92 lb up at 10-1-4, 112 lb down and 92 lb up
at 12-1-4, 112 lb down and 92 lb up at 14-1-4, 112 lb down and 92 lb up at 16-1-4, 112 lb down and 92 lb up at 18-1-4, 112 lb down and 92 lb up at 20-1-4, 112 lb down
and 92 lb up at 22-1-4, 112 lb down and 92 lb up at 24-1-4, 112 lb down and 92 lb up at 26-1-4, 112 lb down and 92 lb up at 28-1-4, 112 lb down and 92 lb up at 30-1-4,
112lb down and 92 lb up at 32-1-4, and 112 lb down and 92 lb up at 34-1-4, and 104 lb down and 95 lb up at 36-1-4 on top chord, and 47 lb down and 19 lb up at 0-6-12
, 39 lb down and 25 lb up at 2-1-4, 39 lb down and 25 lb up at 4-1-4, 39 lb down and 25 lb up at 6-1-4, 39 lb down and 25 lb up at 8-1-4, 39 lb down and 25 lb up at
10-1-4, 39 lb down and 25 lb up at 12-1-4, 39 lb down and 25 lb up at 14-1-4, 39 lb down and 25 lb up at 16-1-4, 39 lb down and 25 lb up at 18-1-4, 39 lb down and 25 lb
up at 20-1-4, 39 lb down and 25 lb up at 22-1-4, 39 lb down and 25 lb up at 24-1-4, 39 lb down and 25 lb up at 26-1-4, 39 lb down and 25 lb up at 28-1-4, 39 lb down
and 25 lb up at 30-1-4, 39 lb down and 25 lb up at 32-1-4, and 39 lb down and 25 lb up at 34-1-4, and 47 lb down and 19 lb up at 36-1-4 on bottomchord.The
design/selection of suchconnection device(s)is the responsibility of others.
9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-10=-61, 11-20=-20
Concentrated Loads(lb)
Vert: 4=-31(F) 7=-31(F) 13=-24(F) 8=-31(F) 21=-49(F) 22=-31(F) 23=-31(F) 24=-31(F) 25=-31(F) 26=-31(F) 27=-31(F) 28=-31(F) 29=-31(F) 30=-31(F) 31=-31(F)
32=-31(F) 33=-31(F) 34=-31(F) 35=-31(F) 36=-49(F) 37=-29(F) 38=-24(F) 39=-24(F) 40=-24(F) 41=-24(F) 42=-24(F) 43=-24(F) 44=-24(F) 45=-24(F) 46=-24(F)
47=-24(F) 48=-24(F) 49=-24(F) 50=-24(F) 51=-24(F) 52=-24(F) 53=-24(F) 54=-29(F)
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T15
TrussType
Flat
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:142019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-4P_VLGe7QEcaqq12AudDIAKHStoDKOPv_lnjHTzZ0AB
Scale=1:63.0
W1
T1
W1
B1
W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2
T3T2
B3B2
1 2 3 4 5 6 7 8 9
18 17 16 15 14 13 12 11 10
19 20
3x4
5x6 3x6 5x6
3x43x65x6
4x4
4x4
3x4
3x8
1.5x4 3x4
4x4
4x4
5x6
3x6
3x6
6-2-8
6-2-8
12-3-4
6-0-12
18-4-0
6-0-12
24-4-12
6-0-12
30-5-8
6-0-12
36-8-0
6-2-8
6-2-8
6-2-8
12-3-4
6-0-12
18-4-0
6-0-12
24-4-12
6-0-12
30-5-8
6-0-12
36-8-0
6-2-8
5-7-2LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.45
0.64
0.68
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.18
-0.45
0.10
(loc)
14
12-14
10
l/defl
>999
>981
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 179 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W2: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-2-6 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 7-4-15 oc bracing.
WEBS 1 Row at midpt 1-18, 9-10
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)18=1470/0-6-0(min. 0-2-7), 10=1470/0-6-0(min. 0-2-7)
Max Horz18=-202(LC 12)
Max Uplift18=-320(LC 12), 10=-320(LC 13)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-18=-1414/347, 1-19=-1452/342, 2-19=-1452/342, 2-3=-2282/498, 3-4=-2564/541,
4-5=-2564/541, 5-6=-2564/541, 6-7=-2282/498, 7-8=-2282/498, 8-20=-1452/342,
9-20=-1452/342, 9-10=-1414/347
BOT CHORD 16-17=-430/1452, 15-16=-430/1452, 14-15=-586/2282, 13-14=-552/2282,
12-13=-552/2282, 11-12=-363/1452
WEBS 1-17=-419/1906, 2-17=-1127/361, 2-15=-252/1102, 3-15=-606/235, 3-14=-100/375,
5-14=-372/177, 6-14=-100/375, 6-12=-606/235, 8-12=-252/1102, 8-11=-1127/361,
9-11=-419/1906
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-9-12,Interior(1) 3-9-12 to 36-6-4zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
3)Provide adequate drainage to preventwater ponding.
4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
5)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
18=320, 10=320.
6)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T16
TrussType
Flat
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:152019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-YcYtZcelBYkRR_cEkb8SrNtPVH9x3qU2CPXGpvzZ0AA
Scale=1:63.0
W1
T1
W1
B1
W2
W1
W2 W1
W2
W1 W2
W1
W2
T3T2
B3B2
1 2 3 4 5 6 7 8
16 15 14 13 12 11 10 9
17 18
3x4
5x6 3x6 5x6
3x43x65x6
3x4
3x4
3x4 1.5x4
4x8
3x4
5x6
3x6
3x6
7-5-1
7-5-1
14-8-6
7-3-5
21-11-10
7-3-5
29-2-15
7-3-5
36-8-0
7-5-1
7-5-1
7-5-1
14-8-6
7-3-5
21-11-10
7-3-5
29-2-15
7-3-5
36-8-0
7-5-1
7-1-2LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.69
0.61
0.75
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.38
0.07
(loc)
12-13
12-13
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 186 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W2: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-5-6 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 7-8-9 oc bracing.
WEBS 1 Row at midpt 1-16, 8-9, 2-15, 4-12, 7-10
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)16=1470/0-6-0(min. 0-2-7), 9=1470/0-6-0(min. 0-2-7)
Max Horz16=-260(LC 12)
Max Uplift16=-330(LC 12), 9=-330(LC 13)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-16=-1404/361, 1-17=-1317/321, 2-17=-1317/321, 2-3=-1935/424, 3-4=-1935/424,
4-5=-1934/424, 5-6=-1934/424, 6-7=-1934/424, 7-18=-1317/321, 8-18=-1317/321,
8-9=-1405/361
BOT CHORD 15-16=-256/275, 14-15=-434/1317, 13-14=-434/1317, 12-13=-537/1935, 11-12=-357/1317,
10-11=-357/1317
WEBS 1-15=-406/1779, 2-15=-1060/380, 2-13=-212/846, 4-13=-434/228, 5-12=-434/207,
7-12=-211/845, 7-10=-1060/380, 8-10=-406/1779
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-9-12,Interior(1) 3-9-12 to 36-6-4zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
3)Provide adequate drainage to preventwater ponding.
4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
5)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
16=330, 9=330.
6)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T17
TrussType
Flat
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:162019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-0o6FmyfNyrsI38BRIIfhNbQbUhWDoGRBR3GqMLzZ0A9
Scale=1:63.3
W1
T1
W1
B1
W2 W1 W2 W1
W2
W1 W2 W1 W2
T3T2
B3B2
1 2 3 4 5 6 7 8
16 15 14 13 12 11 10 9
17 18
3x4
5x6 3x6 5x6
3x43x65x6
3x4
3x4
3x4 1.5x4
3x10
3x4
5x6
3x6
3x6
7-5-1
7-5-1
14-8-6
7-3-5
21-11-10
7-3-5
29-2-15
7-3-5
36-8-0
7-5-1
7-5-1
7-5-1
14-8-6
7-3-5
21-11-10
7-3-5
29-2-15
7-3-5
36-8-0
7-5-1
8-7-2LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.61
0.54
0.77
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.10
-0.31
0.06
(loc)
12-13
12-13
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 203 lb FT= 20%
GRIP
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-10-9 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 9-9-9 oc bracing.
WEBS 1 Row at midpt 1-16, 8-9, 2-15, 4-13, 4-12, 5-12, 7-10
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)16=1470/0-6-0(min. 0-2-7), 9=1470/0-6-0(min. 0-2-7)
Max Uplift16=-306(LC 12), 9=-306(LC 12)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-16=-1405/341, 1-17=-1080/225, 2-17=-1080/225, 2-3=-1586/330, 3-4=-1586/330,
4-5=-1585/330, 5-6=-1585/330, 6-7=-1585/330, 7-18=-1080/225, 8-18=-1080/225,
8-9=-1405/341
BOT CHORD 14-15=-225/1080, 13-14=-225/1080, 12-13=-330/1586, 11-12=-225/1080,
10-11=-225/1080
WEBS 1-15=-336/1618, 2-15=-1061/350, 2-13=-160/768, 4-13=-434/205, 5-12=-434/205,
7-12=-159/767, 7-10=-1061/350, 8-10=-336/1618
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-9-12,Interior(1) 3-9-12 to 36-6-4zone;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
3)Provide adequate drainage to preventwater ponding.
4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
5)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
16=306, 9=306.
6)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T18
TrussType
Hip
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:172019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-U_gd_Ig?i9_9hImdr0Awwoyih5sWXj?Lgj0NuozZ0A8
Scale=1:75.0
0-1-140-1-14T1
T2 T5
B1
W3 W4 W5 W4 W5 W4 W5 W4 W5 W4 W3W1
W2
W7
W6
T4T3
B3B2
1
2 3 4 5 6 7 8 910
20 19 18 17 16 15 14 13 12 11
21 22 23 24
6x6
3x6 5x6
3x4 3x65x65x6
3x4
3x8
1.5x4 3x4
3x4
3x4
5x6
6x6
4x6
5x6
3x4
3x8
3x6
3-4-0
3-4-0
9-8-2
6-4-2
16-2-1
6-5-14
22-7-15
6-5-14
29-1-14
6-5-14
35-6-0
6-4-2
36-8-0
1-2-0
3-4-0
3-4-0
9-8-2
6-4-2
16-2-1
6-5-14
22-7-15
6-5-14
29-1-14
6-5-14
35-6-0
6-4-2
36-8-0
1-2-0
8-7-010-1-210-3-09-8-010-1-26.0012
PlateOffsets(X,Y)-- [11:Edge,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.84
0.48
0.82
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.32
0.06
(loc)
14-16
14-16
11
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 260 lb FT= 20%
GRIP
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-10-9 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-19, 3-18, 4-16, 6-14, 7-13, 9-12, 1-20,
10-11
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)20=1439/0-6-0(min. 0-2-11), 11=1458/0-6-0(min. 0-2-13)
Max Horz20=52(LC 16)
Max Uplift20=-249(LC 13), 11=-287(LC 12)
MaxGrav20=1627(LC 37), 11=1720(LC 37)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-557/109, 2-21=-1279/246, 3-21=-1282/246, 3-22=-1556/299, 4-22=-1556/299,
4-5=-1556/299, 5-6=-1556/299, 6-23=-1489/283, 7-23=-1489/283, 7-24=-1086/197,
8-24=-1086/197, 8-9=-1086/197, 1-20=-1608/255, 10-11=-1484/175
BOT CHORD 18-19=-114/514, 17-18=-242/1279, 16-17=-242/1279, 15-16=-280/1489, 14-15=-280/1489,
13-14=-194/1086
WEBS 2-19=-1252/268, 2-18=-253/1413, 3-18=-1054/293, 3-16=-108/518, 4-16=-390/184,
6-14=-488/209, 7-14=-157/730, 7-13=-1247/332, 9-13=-303/1679, 9-12=-1652/356,
1-19=-214/1442, 10-12=-194/1473
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 7-6-15,Interior(1) 7-6-15 to 35-6-0,Exterior(2) 35-6-0 to 36-6-4
zone;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
20=249, 11=287.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T19
TrussType
Hip
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:192019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-QNoOP_hGEmEtwbv0zRCO?D13suZU?dye71VUygzZ0A6
Scale=1:77.0
0-1-140-1-14T1
T2
T4
B1
W3
W4
W5 W4 W5 W4 W5
W4
W3W1
W2
W7
W6
T3
B1B2
1
2 3 4 5 6 7
8
17 16 15 14 13 12 11 10 9
18
19
20 21 22 23 24 25 26
6x6
3x6
3x4 3x64x64x4
3x4 1.5x4
3x8
3x4
5x6
6x6
5x6
5x6
3x4
5x6
3x6
6-4-0
6-4-0
12-9-10
6-5-10
19-5-0
6-7-6
26-0-6
6-7-6
32-6-0
6-5-10
36-8-0
4-2-0
6-4-0
6-4-0
12-9-10
6-5-10
19-5-0
6-7-6
26-0-6
6-7-6
32-6-0
6-5-10
36-8-0
4-2-0
8-7-011-7-211-9-09-8-011-7-26.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.79
0.44
0.79
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.11
-0.26
0.05
(loc)
13
13-15
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 254 lb FT= 20%
GRIP
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-7-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-16, 2-15, 3-15, 4-13, 6-11, 7-11, 7-10,
1-17, 8-9
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)17=1411/0-6-0(min. 0-2-9), 9=1426/0-6-0(min. 0-2-11)
Max Horz17=78(LC 16)
Max Uplift17=-196(LC 13), 9=-226(LC 12)
MaxGrav17=1567(LC 37), 9=1652(LC 37)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-18=-895/156, 18-19=-861/160, 2-19=-856/178, 2-20=-1335/265, 20-21=-1335/264,
3-21=-1338/264, 3-22=-1453/271, 4-22=-1453/271, 4-23=-1453/271, 5-23=-1453/271,
5-6=-1453/271, 6-24=-1227/240, 24-25=-1224/240, 7-25=-1222/240, 7-26=-576/134,
8-26=-622/122, 1-17=-1515/270, 8-9=-1624/281
BOT CHORD 15-16=-148/786, 14-15=-232/1335, 13-14=-232/1335, 12-13=-197/1224, 11-12=-197/1224,
10-11=-78/562
WEBS 2-16=-925/210, 2-15=-206/1110, 3-15=-833/257, 4-13=-464/184, 6-13=-95/454,
6-11=-1024/290, 7-11=-240/1337, 7-10=-1213/253, 1-16=-156/1310, 8-10=-197/1433
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 6-4-0,Exterior(2) 6-4-0 to 36-6-4
zone;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
17=196, 9=226.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T20
TrussType
PiggybackBase
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:202019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-uZLmcJiu?4MkYlUCX8kdYRaFiIuWk4GnMhE1V6zZ0A5
Scale=1:78.3
T1
T2
T4
B1
W3
W4
W5 W4 W5 W4 W5
W4
W3W1
W2
W7
W6
T3
B1B2
1
2 3 4 5 6 7
8
17 16 15 14 13 12 11 10 9
18
19
20 21 22 23 24
25
3x6
3x4 3x64x64x4
5x6 3x4 1.5x4
3x8
3x4
5x6
5x6
6x6
5x6
3x4
5x6
3x6
5-10-0
5-10-0
12-6-10
6-8-10
19-5-0
6-10-6
26-3-6
6-10-6
33-0-0
6-8-10
36-8-0
3-8-0
5-10-0
5-10-0
12-6-10
6-8-10
19-5-0
6-10-6
26-3-6
6-10-6
33-0-0
6-8-10
36-8-0
3-8-0
8-7-011-6-09-8-011-6-06.0012
PlateOffsets(X,Y)-- [2:0-3-0,0-2-0], [7:0-3-0,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.72
0.46
0.78
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.12
-0.26
0.06
(loc)
13
13-15
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 253 lb FT= 20%
GRIP
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-6-10 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-16, 2-15, 3-15, 4-13, 6-11, 7-11, 7-10,
1-17, 8-9
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)17=1415/0-6-0(min. 0-2-10), 9=1432/0-6-0(min. 0-2-12)
Max Horz17=76(LC 16)
Max Uplift17=-205(LC 13), 9=-237(LC 12)
MaxGrav17=1577(LC 37), 9=1663(LC 37)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-18=-850/148, 18-19=-820/153, 2-19=-783/170, 2-20=-1331/261, 20-21=-1331/261,
3-21=-1331/261, 3-22=-1452/273, 4-22=-1452/273, 4-23=-1452/273, 5-23=-1452/273,
5-6=-1452/273, 6-24=-1213/236, 7-24=-1213/236, 7-25=-520/122, 8-25=-562/111,
1-17=-1531/266, 8-9=-1642/277
BOT CHORD 15-16=-144/745, 14-15=-236/1331, 13-14=-236/1331, 12-13=-200/1213, 11-12=-200/1213,
10-11=-73/509
WEBS 2-16=-963/217, 2-15=-210/1140, 3-15=-838/263, 4-13=-451/191, 6-13=-98/456,
6-11=-1031/297, 7-11=-247/1370, 7-10=-1261/265, 1-16=-163/1316, 8-10=-206/1457
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 5-10-0,Exterior(2) 5-10-0 to 36-6-4
zone;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
17=205, 9=237.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T21
TrussType
PiggybackBase
Qty
4
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:222019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-ryTW1?k8XhcSn3ebeZm5dsfch6XIC_m4p?j8Z?zZ0A3
Scale=1:77.8
T1
T2
T4
B1
B2
B3
B4
B5
W3
W4 W5 W6 W5
W8
W7
W9 W10 W9 W10 W11W1
W2
W13
W12
T3
B6
1
2
3 4 5 6 7 8 9
10
22 21
20
19 18
17
16 15 14 13 12 11
23
24
25 26 27 28
29
4x6
3x6
3x4
4x6
3x5 5x8
2x4
3x4 3x6
5x6 5x6
5x6 3x4
3x4
5x8
3x4
5x6
5x6
6x66x6 3x4
5x6
2-6-0
2-6-0
5-10-0
3-4-0
10-4-0
4-6-0
14-10-0
4-6-0
20-10-1
6-0-1
26-11-15
6-1-13
33-0-0
6-0-1
36-8-0
3-8-0
2-6-0
2-6-0
5-10-0
3-4-0
10-4-0
4-6-0
14-10-0
4-6-0
20-10-1
6-0-1
26-11-15
6-1-13
33-0-0
6-0-1
36-8-0
3-8-0
8-7-011-6-09-8-01-0-011-6-06.0012
PlateOffsets(X,Y)-- [3:0-3-0,0-2-0], [9:0-3-0,0-2-0], [17:0-2-8,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.69
0.69
0.78
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.31
0.17
(loc)
5
15-16
11
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 297 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W8: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-2-6 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
4-4-13 oc bracing: 20-21.
1 Row at midpt 2-20, 5-17
WEBS 1 Row at midpt 3-19, 4-18, 6-15, 8-13, 9-12, 1-22, 10-11
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)22=1415/0-6-0(min. 0-2-10), 11=1432/0-6-0(min. 0-2-12)
Max Horz22=76(LC 16)
Max Uplift22=-205(LC 13), 11=-237(LC 12)
MaxGrav22=1577(LC 37), 11=1663(LC 37)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-23=-436/84, 2-23=-410/91, 2-24=-904/189, 3-24=-867/206, 3-25=-1286/261,
4-25=-1286/261, 4-5=-1536/293, 5-26=-1534/293, 6-26=-1534/293, 6-27=-1424/265,
7-27=-1424/265, 7-8=-1424/265, 8-28=-1155/229, 9-28=-1155/229, 9-29=-520/123,
10-29=-562/112, 1-22=-1611/269, 10-11=-1638/279
BOT CHORD 20-21=-1288/208, 2-20=-1303/235, 19-20=-105/384, 18-19=-159/810, 17-18=-231/1286,
5-17=-416/150, 14-15=-189/1155, 13-14=-189/1155, 12-13=-73/506
WEBS 2-19=-156/1125, 3-19=-915/192, 3-18=-209/1179, 4-18=-975/251, 4-17=-124/604,
15-17=-244/1361, 6-15=-602/219, 8-15=-115/566, 8-13=-1084/291, 9-13=-247/1373,
9-12=-1261/259, 1-21=-217/1413, 10-12=-206/1446
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 5-10-0,Exterior(2) 5-10-0 to 36-6-4
zone;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
22=205, 11=237.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T22
TrussType
PiggybackBase
Qty
2
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:232019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-J81uELlmI?kIPDDnCHHKA3CkoVt4xQxD2eTh5RzZ0A2
Scale=1:79.9
T1
T2
T4
B1
B2
B3
B4
B5
W3
W4 W5 W6 W5
W8
W7
W9 W10 W9 W10 W11W1
W13
W12
T3
B6
W2
1
2
3 4 5 6 7 8 9
10
22 21
20
19 18
17
16 15 14 13 12 11
23
24
25 26 27 28 29
4x6
3x6
4x6
3x4
4x6
3x5
5x8
2x4
3x4 3x6
4x4 4x6
5x6 3x4
3x4
5x8
3x4
5x6
5x6
5x6 3x45x6
2-6-0
2-6-0
5-10-0
3-4-0
10-4-0
4-6-0
14-10-0
4-6-0
20-10-1
6-0-1
26-11-15
6-1-13
33-0-0
6-0-1
35-8-0
2-8-0
2-6-0
2-6-0
5-10-0
3-4-0
10-4-0
4-6-0
14-10-0
4-6-0
20-10-1
6-0-1
26-11-15
6-1-13
33-0-0
6-0-1
35-8-0
2-8-0
8-7-011-6-010-2-01-0-011-6-06.0012
PlateOffsets(X,Y)-- [3:0-3-0,0-2-0], [9:0-3-0,0-2-0], [17:0-2-8,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.86
0.66
0.85
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.30
0.16
(loc)
5
15-16
11
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 296 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W8: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-3-11 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
4-5-15 oc bracing: 20-21.
1 Row at midpt 2-20, 5-17
WEBS 1 Row at midpt 3-19, 4-18, 6-15, 8-13, 9-12, 1-22, 10-11
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)22=1376/0-6-0(min. 0-2-8), 11=1400/0-6-0(min. 0-2-12)
Max Horz22=87(LC 16)
Max Uplift22=-197(LC 13), 11=-246(LC 12)
MaxGrav22=1530(LC 37), 11=1660(LC 37)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-23=-423/82, 2-23=-397/91, 2-24=-876/195, 3-24=-839/207, 3-25=-1239/256,
4-25=-1239/256, 4-26=-1469/282, 5-26=-1469/282, 5-27=-1467/282, 6-27=-1467/282,
6-28=-1338/251, 7-28=-1338/251, 7-8=-1338/251, 8-29=-1044/204, 9-29=-1044/204,
9-10=-397/89, 1-22=-1563/269, 10-11=-1642/272
BOT CHORD 20-21=-1248/199, 2-20=-1262/229, 19-20=-128/373, 18-19=-161/784, 17-18=-230/1239,
5-17=-416/150, 14-15=-176/1044, 13-14=-176/1044, 12-13=-56/369
WEBS 2-19=-149/1087, 3-19=-881/183, 3-18=-198/1128, 4-18=-929/241, 4-17=-113/554,
15-17=-235/1278, 6-15=-635/226, 8-15=-124/618, 8-13=-1130/299, 9-13=-255/1429,
9-12=-1371/281, 10-12=-222/1498, 1-21=-213/1370
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-8-9,Interior(1) 3-8-9 to 5-10-0,Exterior(2) 5-10-0 to 35-6-4
zone;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
22=197, 11=246.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T23
TrussType
PiggybackBase
Qty
2
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:252019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-FX9ff1m0qc_0eWN9JhJoFUH7PJUDPLAWVyyoAKzZ0A0
Scale=1:86.4
T1
T2
T4
B1
B2
B3
B4
B5
W3
W4 W5 W6 W5
W8
W7
W9 W10 W9 W10 W11
W12 W13
W1
W2 W15
W14
T3
B6
1
2
3 4 5 6 7 8 9
10
11
24 23
22
21 20
19
18 17 16 15 14 13 12
25
26
27 28 29 30 31
32
33 34
4x6
3x6
3x4
5x6
4x6 5x8
2x4
3x4
3x6
5x6 5x6
5x6 4x4
5x8
3x4
3x4
4x4
5x6
3x4
3x4
4x66x6 3x4
5x6
2-6-0
2-6-0
5-10-0
3-4-0
10-4-0
4-6-0
14-10-0
4-6-0
20-10-1
6-0-1
26-11-15
6-1-13
33-0-0
6-0-1
38-0-4
5-0-4
43-4-0
5-3-12
2-6-0
2-6-0
5-10-0
3-4-0
10-4-0
4-6-0
14-10-0
4-6-0
20-10-1
6-0-1
26-11-15
6-1-13
33-0-0
6-0-1
38-0-4
5-0-4
43-4-0
5-3-12
8-7-011-6-06-4-01-0-011-6-06.0012
PlateOffsets(X,Y)-- [3:0-3-0,0-2-0], [9:0-3-0,0-2-0], [17:0-1-8,0-2-0], [19:0-2-8,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.66
0.93
0.80
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.18
-0.39
0.23
(loc)
5
17-18
12
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 328 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W8,W15: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-3-14 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
3-10-9 oc bracing: 22-23.
1 Row at midpt 2-22, 5-19
WEBS 1 Row at midpt 3-21, 4-20, 6-19, 6-17, 8-16, 9-14, 10-13,
1-24, 11-12
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)24=1674/0-6-0(min. 0-3-1), 12=1645/0-6-0(min. 0-2-13)
Max Horz24=-142(LC 17)
Max Uplift24=-239(LC 13), 12=-191(LC 12)
MaxGrav24=1860(LC 37), 12=1722(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-25=-515/95, 2-25=-489/102, 2-26=-1078/215, 3-26=-1041/232, 3-27=-1568/312,
4-27=-1568/312, 4-5=-1946/366, 5-28=-1943/366, 6-28=-1943/366, 6-29=-1949/380,
7-29=-1949/380, 7-8=-1949/380, 8-30=-1832/376, 30-31=-1832/376, 9-31=-1832/376,
9-32=-1459/326, 10-32=-1519/301, 10-33=-1057/203, 33-34=-1066/187, 11-34=-1096/181,
1-24=-1904/313, 11-12=-1673/291
BOT CHORD 22-23=-1530/263, 2-22=-1554/278, 21-22=-70/455, 20-21=-133/968, 19-20=-221/1568,
5-19=-416/150, 16-17=-232/1832, 15-16=-141/1336, 14-15=-141/1336, 13-14=-132/953
WEBS 2-21=-191/1354, 3-21=-1120/235, 3-20=-267/1486, 4-20=-1255/302, 4-19=-180/913,
17-19=-266/1870, 6-17=-405/188, 8-17=-75/254, 8-16=-801/257, 9-16=-208/1050,
9-14=-559/172, 10-14=-122/767, 10-13=-1013/219, 1-23=-255/1674, 11-13=-201/1463
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 5-10-0,Exterior(2) 5-10-0 to 37-2-15,
Interior(1) 37-2-15 to 43-2-4zone;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
24=239, 12=191.Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T23
TrussType
PiggybackBase
Qty
2
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:252019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-FX9ff1m0qc_0eWN9JhJoFUH7PJUDPLAWVyyoAKzZ0A0
NOTES-
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T24
TrussType
PiggybackBase
Qty
2
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:272019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-BwHP4joHMDEktqXYR6MGKvNRF6F2tFqpzGRvECzZ0A_
Scale=1:85.5
T1
T2
T4
B1
W3
W4
W5 W4 W5
W4
W5
W4
W3
W6 W7
W1
W2 W9
W8
T3
B1B2
1
2 3 4 5 6 7
8
9
19 18 17 16 15 14 13 12 11 10
20 21 22 23 24 25 26
27
28
3x6
3x4 3x65x65x6
5x6 3x4
3x8
1.5x4 3x4
4x4
5x6
3x4
3x4
4x6
5x6
3x4
5x6
3x6
5-10-0
5-10-0
12-6-10
6-8-10
19-5-0
6-10-6
26-3-6
6-10-6
33-0-0
6-8-10
38-0-4
5-0-4
43-4-0
5-3-12
5-10-0
5-10-0
12-6-10
6-8-10
19-5-0
6-10-6
26-3-6
6-10-6
33-0-0
6-8-10
38-0-4
5-0-4
43-4-0
5-3-12
8-7-011-6-06-4-011-6-06.0012
PlateOffsets(X,Y)-- [2:0-3-0,0-2-0], [7:0-3-0,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.77
0.59
0.73
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.15
-0.34
0.09
(loc)
15
14-15
10
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 284 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W9: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-18, 2-17, 3-17, 4-15, 6-15, 6-14, 7-14,
7-12, 8-11, 1-19, 9-10
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)19=1674/Mechanical, 10=1645/Mechanical
Max Horz19=-142(LC 17)
Max Uplift19=-239(LC 13), 10=-191(LC 12)
MaxGrav19=1860(LC 37), 10=1722(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-20=-1008/205, 2-20=-940/222, 2-21=-1644/354, 21-22=-1644/354, 3-22=-1644/354,
3-23=-1938/399, 4-23=-1938/399, 4-24=-1938/399, 5-24=-1938/399, 5-6=-1938/399,
6-25=-1873/401, 25-26=-1873/401, 7-26=-1873/401, 7-8=-1519/349, 8-27=-1035/217,
27-28=-1065/201, 9-28=-1096/195, 1-19=-1814/359, 9-10=-1673/312
BOT CHORD 17-18=-121/889, 16-17=-234/1644, 15-16=-234/1644, 14-15=-240/1873, 13-14=-149/1339,
12-13=-149/1339, 11-12=-146/952
WEBS 2-18=-1175/263, 2-17=-271/1469, 3-17=-1121/315, 3-15=-118/562, 4-15=-451/190,
6-14=-749/263, 7-14=-207/1039, 7-12=-557/177, 8-12=-123/775, 8-11=-1015/235,
1-18=-216/1571, 9-11=-224/1461
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 4-5-12,Interior(1) 4-5-12 to 5-10-0,Exterior(2) 5-10-0 to 39-1-9,
Interior(1) 39-1-9 to 43-2-4zone;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7) Refer to girder(s) for truss to trussconnections.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
19=239, 10=191.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T25
TrussType
Hip
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:282019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-f6qnH3ov7XNbV_5k?qtVt7vZiWc2cimyCwASmfzZ09z
Scale=1:89.8
0-1-140-1-14T1
T2
T4
B1
W3
W4
W5 W4 W5
W4
W5 W4 W3
W6 W7
W1
W2 W9
W8
T3
B1B2
1
2 3 4 5 6 7
8
9
19 18 17 16 15 14 13 12 11 10
20
21
22 23 24 25
26 27
28
6x6
3x6
3x4 3x65x65x6
3x4
3x8
1.5x4 3x4
4x4
6x6
3x4
3x4
4x6
5x6
3x4
5x6
3x6
7-3-4
7-3-4
13-3-4
6-0-0
19-5-0
6-1-12
25-6-12
6-1-12
31-6-12
6-0-0
37-3-10
5-8-14
43-4-0
6-0-6
7-3-4
7-3-4
13-3-4
6-0-0
19-5-0
6-1-12
25-6-12
6-1-12
31-6-12
6-0-0
37-3-10
5-8-14
43-4-0
6-0-6
8-7-012-0-1212-2-106-4-012-0-126.0012
PlateOffsets(X,Y)-- [10:Edge,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.92
0.54
0.75
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.31
0.09
(loc)
15
14-15
10
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 291 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2 *Except*
T1: 2x4SPF 1650F 1.5E
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W9: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-18, 2-17, 3-17, 4-15, 6-15, 6-14, 7-12,
8-11, 1-19, 9-10
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)19=1658/Mechanical, 10=1632/Mechanical
Max Horz19=-153(LC 17)
Max Uplift19=-207(LC 13), 10=-166(LC 12)
MaxGrav19=1825(LC 37), 10=1722(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-20=-1151/220, 20-21=-1110/232, 2-21=-1096/252, 2-22=-1616/364, 3-22=-1619/363,
3-23=-1873/400, 4-23=-1873/400, 4-24=-1873/400, 5-24=-1873/400, 5-6=-1873/400,
6-25=-1812/405, 7-25=-1809/406, 7-8=-1566/364, 8-26=-1093/234, 26-27=-1101/232,
27-28=-1135/217, 9-28=-1182/216, 1-19=-1764/365, 9-10=-1668/316
BOT CHORD 17-18=-128/1010, 16-17=-210/1616, 15-16=-210/1616, 14-15=-206/1809,
13-14=-150/1381, 12-13=-150/1381, 11-12=-154/1016
WEBS 2-18=-1037/246, 2-17=-248/1340, 3-17=-1078/291, 3-15=-109/554, 4-15=-492/171,
6-14=-718/246, 7-14=-192/946, 7-12=-465/163, 8-12=-111/683, 8-11=-922/234,
1-18=-203/1541, 9-11=-219/1450
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 4-5-12,Interior(1) 4-5-12 to 7-3-4,Exterior(2) 7-3-4 to 37-8-5,
Interior(1) 37-8-5 to 43-2-4zone;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7) Refer to girder(s) for truss to trussconnections.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
19=207, 10=166.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T26
TrussType
Hip
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:302019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-cUyYikq9f8dJkIF76FvzyX?u1KFq4YrFfEfZqXzZ09x
Scale=1:81.8
0-1-140-1-14T1
T2
T5
B1
W3 W4 W5 W4 W5 W4 W5 W4 W3
W6
W1
W2 W8
W7
T4T3
B3B2
1
2 3 4 5 6 7 8
9
10
19 18 17 16 15 14 13 12 11
20 21 22 23
24
6x6
3x6
2x4
3x4 3x66x65x6
3x4
3x8
1.5x4 3x4
4x6
6x6
4x4
4x46x6
3x8
3x10MT18H
3x6
4-3-4
4-3-4
11-9-4
7-6-0
19-5-0
7-7-12
27-0-12
7-7-12
34-6-12
7-6-0
43-4-0
8-9-4
4-3-4
4-3-4
11-9-4
7-6-0
19-5-0
7-7-12
27-0-12
7-7-12
34-6-12
7-6-0
38-9-10
4-2-14
43-4-0
4-6-6
8-7-010-6-1210-8-106-4-010-6-126.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.99
0.65
0.97
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.16
-0.42
0.11
(loc)
11-12
11-12
11
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 266 lb FT= 20%
GRIP
185/144
197/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2 *Except*
T4,T3: 2x4SPF 1650F 1.5E
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W8: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied, except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-18, 3-17, 5-15, 6-14, 8-12, 1-19, 9-11
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)19=1691/Mechanical, 11=1659/Mechanical
Max Horz19=-127(LC 17)
Max Uplift19=-274(LC 13), 11=-218(LC 12)
MaxGrav19=1902(LC 37), 11=1741(LC 37)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-810/173, 2-20=-1723/340, 20-21=-1725/340, 3-21=-1728/339, 3-4=-2082/395,
4-5=-2082/395, 5-22=-2082/395, 6-22=-2082/395, 6-23=-2007/396, 7-23=-2007/396,
7-8=-2007/396, 8-9=-1449/316, 1-19=-1878/347
BOT CHORD 17-18=-103/739, 16-17=-263/1725, 15-16=-263/1725, 14-15=-287/2007, 13-14=-155/1303,
12-13=-155/1303, 11-12=-141/847
WEBS 2-18=-1377/299, 2-17=-311/1679, 3-17=-1201/345, 3-15=-131/603, 5-15=-445/211,
6-14=-824/285, 8-14=-244/1198, 8-12=-709/212, 9-12=-117/992, 1-18=-242/1667,
9-11=-1801/310
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 10-4-13,Interior(1) 10-4-13 to 34-6-12,Exterior(2) 34-6-12 to
40-8-5zone;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)All plates areMT20 plates unless otherwiseindicated.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8) Refer to girder(s) for truss to trussconnections.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
19=274, 11=218.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T27
TrussType
Hip
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:312019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-4hWww4rnPSlAMRqJgyQCUlX3xkbhp?CPuuP7N_zZ09w
Scale=1:80.7
0-1-140-1-14T1 T2
T5
B1
W3 W4 W5 W4 W5 W4 W5 W4 W5 W4 W3
W1
W2
W7
W6
T4T3
B3B2
1 2 3 4 5 6 7 8 9
10
2019 18 17 16 15 14 13 12 11
21 22 23 24 25 265x6
6x6
3x6
3x10MT18H 3x6
5x6
6x6
3x5
3x5
3x4
1.5x4
3x8
3x4
5x6
6x6
5x6 3x4
5x6
3x6
3x6
1-3-4
1-3-4
8-5-5
7-2-1
15-9-2
7-3-13
23-0-14
7-3-13
30-4-11
7-3-13
37-6-12
7-2-1
43-4-0
5-9-4
1-3-4
1-3-4
8-5-5
7-2-1
15-9-2
7-3-13
23-0-14
7-3-13
30-4-11
7-3-13
37-6-12
7-2-1
43-4-0
5-9-4
8-7-09-0-129-2-106-4-09-0-126.0012
PlateOffsets(X,Y)-- [11:Edge,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.98
0.67
0.96
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.19
-0.49
0.11
(loc)
15-16
15-16
11
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 261 lb FT= 20%
GRIP
185/144
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W7: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied, except end verticals.
BOT CHORD Rigidceiling directly applied or 9-1-5 oc bracing.
WEBS 1 Row at midpt 2-19, 3-18, 4-16, 6-15, 8-13, 9-12, 1-20,
10-11
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)20=1724/Mechanical, 11=1686/Mechanical
Max Horz20=-100(LC 17)
Max Uplift20=-337(LC 13), 11=-267(LC 12)
MaxGrav20=1968(LC 37), 11=1796(LC 37)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-21=-1562/294, 3-21=-1565/294, 3-22=-2174/429, 4-22=-2174/429, 4-5=-2339/465,
5-6=-2339/465, 6-23=-2339/465, 7-23=-2339/465, 7-8=-2339/465, 8-24=-2053/401,
24-25=-2050/401, 9-25=-2049/402, 9-26=-1143/227, 10-26=-1207/211, 1-20=-1830/230,
10-11=-1753/319
BOT CHORD 18-19=-22/258, 17-18=-257/1561, 16-17=-257/1561, 15-16=-383/2174, 14-15=-335/2050,
13-14=-335/2050, 12-13=-159/1079
WEBS 2-19=-1885/416, 2-18=-389/2068, 3-18=-1433/390, 3-16=-213/987, 4-16=-618/251,
4-15=-64/257, 6-15=-440/208, 8-15=-116/538, 8-13=-1049/319, 9-13=-297/1542,
9-12=-1036/255, 1-19=-254/1823, 10-12=-229/1579
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 7-4-13,Interior(1) 7-4-13 to 37-6-12,Exterior(2) 37-6-12 to 43-2-4
zone;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)All plates areMT20 plates unless otherwiseindicated.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8) Refer to girder(s) for truss to trussconnections.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
20=337, 11=267.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T28
TrussType
HalfHip
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:322019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-Yt4I7QsPAmt1_bPWEfxR1y4He7wrYU7Y6Y8gvQzZ09v
Scale=1:78.6
0-1-14W1
T1
T3
B1
W2
W3
W2 W3 W2 W3 W2 W3 W2
W3
W2
W4 W6W5
T2T1
B3B2
1 2 3 4 5 6 7 8 9
10
20 19 18 17 16 15 14 13 12 11
21 22 23 24
3x10MT18H
6x6 3x6
4x66x6
4x6
4x6
3x4
3x8
1.5x4 3x4
3x5
3x5
5x6
6x6
6x6 3x4
6x6
3x6
3x6
6-10-14
6-10-14
13-8-0
6-9-2
20-5-2
6-9-2
27-2-4
6-9-2
33-11-6
6-9-2
40-6-12
6-7-6
43-4-0
2-9-4
6-10-14
6-10-14
13-8-0
6-9-2
20-5-2
6-9-2
27-2-4
6-9-2
33-11-6
6-9-2
40-6-12
6-7-6
43-4-0
2-9-4
7-6-127-8-106-4-07-6-126.0012
PlateOffsets(X,Y)-- [11:Edge,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.79
0.74
0.85
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.22
-0.55
0.13
(loc)
15-16
15-16
11
l/defl
>999
>944
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 238 lb FT= 20%
GRIP
185/144
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W3,W6,W5: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-7-4 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 8-0-10 oc bracing.
WEBS 1 Row at midpt 1-20, 2-19, 8-13, 9-12, 10-11
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)20=1738/Mechanical, 11=1713/Mechanical
Max Horz20=-49(LC 17)
Max Uplift20=-365(LC 12), 11=-317(LC 12)
MaxGrav20=1980(LC 34), 11=1874(LC 34)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-20=-1918/398, 1-21=-1569/296, 2-21=-1569/296, 2-22=-2378/475, 3-22=-2378/475,
3-4=-2698/551, 4-5=-2698/551, 5-6=-2698/551, 6-23=-2588/520, 7-23=-2588/520,
7-8=-2588/520, 8-24=-1983/387, 9-24=-1983/387, 9-10=-703/134, 10-11=-1863/316
BOT CHORD 18-19=-281/1569, 17-18=-456/2378, 16-17=-456/2378, 15-16=-494/2588,
14-15=-357/1980, 13-14=-357/1980, 12-13=-112/669
WEBS 1-19=-431/2276, 2-19=-1524/406, 2-18=-262/1240, 3-18=-776/271, 3-16=-111/512,
5-16=-415/197, 6-15=-579/228, 8-15=-202/973, 8-13=-1312/359, 9-13=-371/1957,
9-12=-1462/326, 10-12=-277/1689
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 4-5-12,Interior(1) 4-5-12 to 40-6-12,Exterior(2) 40-6-12 to 43-2-4
zone;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)All plates areMT20 plates unless otherwiseindicated.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8) Refer to girder(s) for truss to trussconnections.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
20=365, 11=317.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T29
TrussType
Flat
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:332019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-03egLms2x3?ucl_inNTgaAdWIXI9HwChLCuDRszZ09u
Scale=1:74.5
W1
T1
W1
B1
W2 W1 W2 W1 W2 W1
W2
W1 W2 W1 W2 W1 W2
T3T2
B3B2
1 2 3 4 5 6 7 8 9 10
20 19 18 17 16 15 14 13 12 11
21 22
4x4
4x8 3x6
4x8
4x44x86x6
4x6
4x6
3x4
4x4
3x4 1.5x4
4x8
3x4
4x6
4x6
6x6
3x6
4x8
6-3-9
6-3-9
12-5-5
6-1-13
18-7-2
6-1-13
24-8-14
6-1-13
30-10-11
6-1-13
37-0-7
6-1-13
43-4-0
6-3-9
6-3-9
6-3-9
12-5-5
6-1-13
18-7-2
6-1-13
24-8-14
6-1-13
30-10-11
6-1-13
37-0-7
6-1-13
43-4-0
6-3-9
6-0-12PlateOffsets(X,Y)-- [11:Edge,0-3-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.54
0.61
0.93
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.25
-0.61
0.10
(loc)
15-16
15-16
11
l/defl
>999
>840
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 241 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x6SPF No.2
WEBS 2x4SPFStud*Except*
W2: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-8-8 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 8-4-3 oc bracing.
WEBS 1 Row at midpt 1-20, 10-11, 5-15
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)20=1739/Mechanical, 11=1739/Mechanical
Max Horz20=217(LC 13)
Max Uplift20=-376(LC 12), 11=-376(LC 13)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-20=-1680/398, 1-21=-1658/391, 2-21=-1658/391, 2-3=-2721/596, 3-4=-3261/693,
4-5=-3261/693, 5-6=-3256/692, 6-7=-3256/692, 7-8=-3256/692, 8-9=-2722/596,
9-22=-1658/391, 10-22=-1658/391, 10-11=-1679/398
BOT CHORD 18-19=-485/1658, 17-18=-691/2721, 16-17=-691/2721, 15-16=-788/3261,
14-15=-645/2722, 13-14=-645/2722, 12-13=-407/1658
WEBS 1-19=-480/2236, 2-19=-1390/418, 2-18=-324/1448, 3-18=-864/289, 3-16=-174/735,
5-16=-372/192, 6-15=-374/178, 8-15=-171/727, 8-13=-859/288, 9-13=-324/1450,
9-12=-1391/418, 10-12=-479/2236
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 4-5-12,Interior(1) 4-5-12 to 43-2-4zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
3)Provide adequate drainage to preventwater ponding.
4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
5) Refer to girder(s) for truss to trussconnections.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
20=376, 11=376.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T30
TrussType
FlatGirder
Qty
1
Ply
2
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:392019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-rD?ybpxoXvl1KgRs8eZ4pRsckyJhhfnak8LYfWzZ09o
Scale=1:75.3
W1
T1
W1
B1
W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2
T3T2
B3B2
1 2 3 4 5 6 7 8 9 10 11
22 21 20 19 18 17 16 15 14 13 12
23 24 2526 27 28 29 30 31 3233 34 35 36 37 38 39 40 41
42 43 44 4546 47 48 49 50 5152 53 54 55 56 57 58
3x10
5x6 5x6
3x106x10
2x4
2x4
2x4
2x4
2x4
2x4
2x4
6x10
5-6-5
5-6-5
10-10-14
5-4-9
16-3-7
5-4-9
21-8-0
5-4-9
27-0-9
5-4-9
32-5-2
5-4-9
37-9-11
5-4-9
43-4-0
5-6-5
5-6-5
5-6-5
10-10-14
5-4-9
16-3-7
5-4-9
21-8-0
5-4-9
27-0-9
5-4-9
32-5-2
5-4-9
37-9-11
5-4-9
43-4-0
5-6-5
4-5-10LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.29
0.73
0.86
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.40
-0.59
0.13
(loc)
17
17
12
l/defl
>999
>869
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 497 lb FT= 20%
GRIP
197/144
LUMBER-
TOP CHORD2x6SPF No.2
BOT CHORD2x6SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-11-1 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 8-2-13 oc bracing.
REACTIONS.(lb/size)22=2555/Mechanical, 12=2624/Mechanical
Max Uplift22=-1429(LC 8), 12=-1481(LC 8)
MaxGrav22=2692(LC 2), 12=2767(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-22=-2591/1426, 1-23=-3216/1707, 23-24=-3216/1707, 24-25=-3216/1707,
2-25=-3216/1707, 2-26=-3216/1707, 26-27=-3216/1707, 3-27=-3216/1707,
3-28=-6797/3604, 4-28=-6797/3604, 4-29=-6797/3604, 5-29=-6797/3604,
5-30=-6797/3604, 30-31=-6797/3604, 31-32=-6797/3604, 6-32=-6797/3604,
6-33=-6796/3603, 33-34=-6796/3603, 7-34=-6796/3603, 7-35=-6796/3603,
8-35=-6796/3603, 8-36=-6796/3603, 9-36=-6796/3603, 9-37=-3208/1698,
37-38=-3208/1698, 38-39=-3208/1698, 10-39=-3208/1698, 10-40=-3208/1698,
40-41=-3208/1698, 11-41=-3208/1698, 11-12=-2642/1475
BOT CHORD 21-45=-2896/5454, 45-46=-2896/5454, 20-46=-2896/5454, 19-20=-2896/5454,
19-47=-2896/5454, 18-47=-2896/5454, 18-48=-3848/7249, 48-49=-3848/7249,
49-50=-3848/7249, 17-50=-3848/7249, 17-51=-3848/7249, 51-52=-3848/7249,
16-52=-3848/7249, 15-16=-2893/5452, 15-53=-2893/5452, 14-53=-2893/5452,
14-54=-2893/5452, 54-55=-2893/5452, 55-56=-2893/5452, 13-56=-2893/5452
WEBS 1-21=-2110/3975, 2-21=-516/414, 3-21=-2791/1483, 3-20=0/324, 3-18=-884/1676,
5-18=-470/372, 6-18=-564/303, 6-17=0/328, 6-16=-565/304, 7-16=-472/374,
9-16=-887/1676, 9-14=0/329, 9-13=-2799/1489, 10-13=-510/406, 11-13=-2100/3967
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
5) Unbalancedsnowloads have been considered for this design.
6)Provide adequate drainage to preventwater ponding.
7)All plates are 4x8MT20 unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T30
TrussType
FlatGirder
Qty
1
Ply
2
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:392019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-rD?ybpxoXvl1KgRs8eZ4pRsckyJhhfnak8LYfWzZ09o
NOTES-
9) Refer to girder(s) for truss to trussconnections.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 22=1429, 12=1481.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
12) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 122 lb down and 103 lb up at 1-1-4, 122 lb down and 103 lb up at
3-1-4, 122 lb down and 103 lb up at 5-1-4, 122 lb down and 103 lb up at 7-1-4, 122 lb down and 103 lb up at 9-1-4, 122 lb down and 103 lb up at 11-1-4, 122 lb down
and 103 lb up at 13-1-4, 122 lb down and 103 lb up at 15-1-4, 122 lb down and 103 lb up at 17-1-4, 122 lb down and 103 lb up at 19-1-4, 122 lb down and 103 lb up at
21-1-4, 122 lb down and 103 lb up at 23-1-4, 122 lb down and 103 lb up at 25-1-4, 122 lb down and 103 lb up at 27-1-4, 122 lb down and 103 lb up at 29-1-4, 122 lb
down and 103 lb up at 31-1-4, 122 lb down and 103 lb up at 33-1-4, 122 lb down and 103 lb up at 35-1-4, 122 lb down and 103 lb up at 37-1-4, 122 lb down and 103 lb
up at 39-1-4, and 122 lb down and 103 lb up at 41-1-4, and 109 lb down and 107 lb up at 43-2-4 on top chord, and 45 lb down and 23 lb up at 1-1-4, 45 lb down and 24
lb up at 3-1-4, 45 lb down and 24 lb up at 5-1-4, 45 lb down and 24 lb up at 7-1-4, 45 lb down and 24 lb up at 9-1-4, 45 lb down and 24 lb up at 11-1-4, 45 lb down and
24lb up at 13-1-4, 45 lb down and 24 lb up at 15-1-4, 45 lb down and 24 lb up at 17-1-4, 45 lb down and 24 lb up at 19-1-4, 45 lb down and 24 lb up at 21-1-4, 45 lb
down and 24 lb up at 23-1-4, 45 lb down and 24 lb up at 25-1-4, 45 lb down and 24 lb up at 27-1-4, 45 lb down and 24 lb up at 29-1-4, 45 lb down and 24 lb up at
31-1-4, 45 lb down and 24 lb up at 33-1-4, 45 lb down and 24 lb up at 35-1-4, 45 lb down and 24 lb up at 37-1-4, 45 lb down and 24 lb up at 39-1-4, and 45 lb down and
24lb up at 41-1-4, and 63 lb down and 14 lb up at 43-2-4 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-11=-61, 12-22=-20
Concentrated Loads(lb)
Vert: 11=-73(B) 12=-39(B) 19=-30(B) 3=-46(B) 20=-30(B) 7=-46(B) 16=-30(B) 15=-30(B) 23=-47(B) 24=-46(B) 25=-46(B) 26=-46(B) 27=-46(B) 28=-46(B) 29=-46(B)
30=-46(B) 31=-46(B) 32=-46(B) 33=-46(B) 34=-46(B) 35=-46(B) 36=-46(B) 37=-46(B) 38=-46(B) 39=-46(B) 40=-46(B) 41=-46(B) 42=-30(B) 43=-30(B) 44=-30(B)
45=-30(B) 46=-30(B) 47=-30(B) 48=-30(B) 49=-30(B) 50=-30(B) 51=-30(B) 52=-30(B) 53=-30(B) 54=-30(B) 55=-30(B) 56=-30(B) 57=-30(B) 58=-30(B)
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T31
TrussType
Jack-ClosedGirder
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:412019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-nc7i0Vz33X?lZ_bEF2cYusyyNm4_9eRtBSqejOzZ09m
Scale=1:29.0
0-1-14W1
T1
T2
W5
B1
W2
W3 W4 W5 W4 W5 W4
1
2
3 4 5 6
11
10 9 8
7
12 13 14 15 16
17 18 19
20
1.5x4
3x5
6x6
1.5x44x43x4
3x4 1.5x4
4x10
4x4
2-11-12
2-11-12
6-11-7
3-11-11
11-0-13
4-1-7
15-4-0
4-3-3
-1-4-12
1-4-12
2-11-12
2-11-12
6-11-7
3-11-11
11-0-13
4-1-7
15-4-0
4-3-3
1-2-02-6-02-7-142-6-06.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.28
0.42
0.53
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.06
-0.10
0.02
(loc)
8-9
8-9
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 65 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-7-2 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)11=661/0-4-0(min. 0-1-8), 7=599/0-6-0(min. 0-1-8)
Max Horz11=67(LC 12)
Max Uplift11=-359(LC 8), 7=-417(LC 8)
MaxGrav11=703(LC 31), 7=788(LC 31)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-11=-678/351, 2-3=-824/459, 3-12=-1352/693, 12-13=-1353/693, 4-13=-1356/693,
4-14=-1120/561, 5-14=-1120/561, 5-15=-1120/561, 15-16=-1120/561, 6-16=-1120/561,
6-7=-745/376
BOT CHORD 10-17=-419/741, 9-17=-419/741, 9-18=-691/1353, 8-18=-691/1353
WEBS 2-10=-419/762, 3-9=-313/733, 4-9=-282/98, 4-8=-264/148, 5-8=-379/161,
6-8=-615/1231
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft exposed ; end verticalleft exposed; porchleft exposed; Lumber DOL=1.60 plate
grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
11=359, 7=417.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 119 lb down and 111 lb up at
2-11-12, 69 lb down and 45 lb up at 5-0-8, 69 lb down and 45 lb up at 7-0-8, 69 lb down and 45 lb up at 9-0-8, 69 lb down and 45
lb up at 11-0-8, and 69 lb down and 45 lb up at 13-0-8, and 59 lb down and 48 lb up at 14-9-4 on top chord, and 49 lb down and
77lb up at 2-11-12, 7 lb down and 34 lb up at 5-0-8, 7 lb down and 34 lb up at 7-0-8, 7 lb down and 34 lb up at 9-0-8, 7 lb down
and 34 lb up at 11-0-8, and 7 lb down and 34 lb up at 13-0-8, and 10 lb down and 34 lb up at 14-9-4 on bottomchord.The
design/selection of suchconnection device(s)is the responsibility of others.
11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T31
TrussType
Jack-ClosedGirder
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:412019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-nc7i0Vz33X?lZ_bEF2cYusyyNm4_9eRtBSqejOzZ09m
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51, 2-3=-51, 3-6=-61, 7-11=-20
Concentrated Loads(lb)
Vert: 10=3(F) 9=0(F) 8=0(F) 17=0(F) 18=0(F) 19=0(F) 20=0(F)
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T32
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:422019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-Foh4Erzhqq7cB8ARpm7nR3U279Sau790Q6ZCFrzZ09l
Scale=1:29.2
0-1-14W1
T1
T2
W5
B1
W2
W3 W4 W5 W4
1
2
3 4 5
9
8 7
6
10
11
12 13
3x6
5x6
6x6
3x64x4
1.5x4
3x10
3x4
5-11-12
5-11-12
10-6-2
4-6-6
15-4-0
4-9-14
-1-4-12
1-4-12
5-11-12
5-11-12
10-6-2
4-6-6
15-4-0
4-9-14
1-2-04-0-04-1-144-0-06.0012
PlateOffsets(X,Y)-- [2:0-3-0,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.60
0.27
0.44
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.06
-0.08
0.01
(loc)
8-9
8-9
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 70 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 7-4-4 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)9=643/0-4-0(min. 0-1-8), 6=592/0-6-0(min. 0-1-8)
Max Horz9=128(LC 16)
Max Uplift9=-155(LC 12), 6=-244(LC 12)
MaxGrav9=786(LC 36), 6=740(LC 35)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-9=-730/479, 2-10=-741/570, 10-11=-702/581, 3-11=-695/598, 3-12=-677/500,
4-12=-680/499, 4-13=-676/499, 5-13=-676/499, 5-6=-694/452
BOT CHORD 8-9=-334/233, 7-8=-574/624
WEBS 2-8=-318/531, 4-7=-474/158, 5-7=-618/839
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-1-4-12 to 1-7-4,Interior(1) 1-7-4 to 5-11-12,Exterior(2) 5-11-12 to 10-6-2
zone;cantileverleft exposed ; end verticalleft exposed; porchleft exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
9=155, 6=244.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T33
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:432019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-j?ESRB_Jb8FToHldNTe0zH1CKZj9dVbAemJloHzZ09k
Scale=1:35.5
0-1-14W1
T1
T2
W6
B1
W2 W3
W4 W5
1
2
3
4 5
8 7 6
9
10
1112 13
3x4
4x4
3x8
4x4
3x4 6x6
6x6
8-11-12
8-11-12
15-4-0
6-4-4
-1-4-12
1-4-12
4-9-0
4-9-0
8-11-12
4-2-11
15-4-0
6-4-4
1-2-05-6-05-7-145-6-06.0012
PlateOffsets(X,Y)-- [5:Edge,0-3-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.70
0.57
0.74
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.28
-0.37
0.02
(loc)
7-8
7-8
6
l/defl
>651
>485
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 72 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W5: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-7-14 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)8=628/0-4-0(min. 0-1-8), 6=578/0-6-0(min. 0-1-8)
Max Horz8=189(LC 16)
Max Uplift8=-105(LC 12), 6=-207(LC 12)
MaxGrav8=875(LC 36), 6=655(LC 35)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-8=-399/276, 2-9=-234/256, 3-9=-183/278, 3-10=-611/472, 4-10=-518/483,
5-6=-268/90
BOT CHORD 7-8=-565/690, 6-7=-460/460
WEBS 3-8=-685/239, 3-7=-277/174, 4-7=-428/368, 4-6=-590/586
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-1-4-12 to 1-7-4,Interior(1) 1-7-4 to 8-11-12,Exterior(2) 8-11-12 to 13-2-11
zone;cantileverleft exposed ; end verticalleft exposed; porchleft exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
8=105, 6=207.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T34
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:452019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-fNMDst0Z6lWB2bv?UugU3i6ZHNSR5QvT64ossAzZ09i
Scale=1:41.9
0-1-14W1
T1
T2
W7
B1W2
W3 W4
W5 W6
1
2
3
4 5
9 8 7 6
10
11
3x6
4x6
6x6
1.5x4
6x64x4
3x4
3x4
6-1-10
6-1-10
11-11-12
5-10-2
15-4-0
3-4-4
-1-4-12
1-4-12
6-1-10
6-1-10
11-11-12
5-10-2
15-4-0
3-4-4
1-2-07-0-07-1-147-0-06.0012
PlateOffsets(X,Y)-- [2:0-3-0,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.54
0.32
0.69
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.07
-0.09
0.01
(loc)
8-9
8-9
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 81 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W6: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-5-2 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 7-0-14 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)9=618/0-4-0(min. 0-1-8), 6=557/0-6-0(min. 0-1-8)
Max Horz9=251(LC 16)
Max Uplift9=-97(LC 16), 6=-155(LC 12)
MaxGrav9=870(LC 36), 6=637(LC 36)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-9=-813/421, 2-10=-997/484, 3-10=-786/512, 3-11=-452/203, 4-11=-325/231
BOT CHORD 8-9=-354/210, 7-8=-615/792, 6-7=-242/283
WEBS 2-8=-265/590, 3-7=-607/441, 4-7=-445/441, 4-6=-658/561
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-1-4-12 to 1-7-4,Interior(1) 1-7-4 to 11-11-12,Exterior(2) 11-11-12 to
15-2-4zone;cantileverleft exposed ; end verticalleft exposed; porchleft exposed;C-C formembers and forces&MWFRS for
reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 9 except(jt=lb)
6=155.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T35
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:452019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-fNMDst0Z6lWB2bv?UugU3i6Y2NQl5XnT64ossAzZ09i
Scale=1:49.4
W1
T2
W5
B1W2
W3
W4T1
1
2
3
4
5
8 7 6
9
10
3x4
4x6
3x6
4x6
3x6
4x4
3x4
7-7-10
7-7-10
15-4-0
7-8-6
-1-4-12
1-4-12
7-7-10
7-7-10
14-11-12
7-4-2
15-4-0
0-4-4
1-2-08-6-06.0012
PlateOffsets(X,Y)-- [2:0-3-0,0-1-8], [5:0-2-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.62
0.50
0.25
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.18
0.01
(loc)
6-7
6-7
6
l/defl
>999
>977
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 78 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W5: 2x6SPF No.2, W2,W4: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 7-9-15 oc bracing.
WEBS 1 Row at midpt 5-6, 3-6
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)8=612/0-4-0(min. 0-1-8), 6=525/0-6-0(min. 0-1-8)
Max Horz8=362(LC 13)
Max Uplift8=-114(LC 16), 6=-173(LC 16)
MaxGrav8=696(LC 2), 6=612(LC 23)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-8=-629/228, 2-9=-726/88, 3-9=-545/125
BOT CHORD 7-8=-511/508, 6-7=-267/564
WEBS 2-7=0/393, 3-7=0/306, 3-6=-642/243
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-1-4-12 to 1-7-4,Interior(1) 1-7-4 to 15-1-4zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
8=114, 6=173.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T36
TrussType
Jack-Closed
Qty
12
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:472019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-cmUzHY1qeNmuHv2OcJjy87CthA5rZP4lZNHzx2zZ09g
Scale=1:50.3
W1
T2
W5
B1W2
W3
W4T1
1
2
3
4
5
8 7 6
9
10
3x4
3x6
3x4
4x4
4x6
6x6
3x4
7-8-0
7-8-0
15-4-0
7-8-0
-1-4-12
1-4-12
7-8-0
7-8-0
15-4-0
7-8-0
1-2-08-10-06.0012
PlateOffsets(X,Y)-- [2:0-3-0,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.67
0.52
0.26
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.16
-0.21
0.01
(loc)
6-7
6-7
6
l/defl
>999
>844
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 74 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W1,W3: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 7-1-0 oc bracing.
WEBS 1 Row at midpt 5-6, 3-6
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)8=615/0-4-0(min. 0-1-8), 6=528/0-6-0(min. 0-1-8)
Max Horz8=321(LC 16)
Max Uplift8=-67(LC 16), 6=-221(LC 16)
MaxGrav8=699(LC 2), 6=616(LC 23)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-8=-632/367, 2-9=-734/364, 3-9=-552/400
BOT CHORD 7-8=-463/291, 6-7=-553/572
WEBS 2-7=-105/364, 3-7=-342/313, 3-6=-659/636
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-1-4-12 to 1-7-4,Interior(1) 1-7-4 to 15-2-4zone;cantileverleft exposed ;
endverticalleft exposed; porchleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 8 except(jt=lb)
6=221.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T37
TrussType
Jack-ClosedGirder
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:482019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-4y2LUu2SPgulv3daA1EBgKk32aPJIj8vo10WTVzZ09f
Scale=1:34.4
0-1-11W1
T1
T2
W5
B1
W2
W3 W4 W5 W4 W5 W4
B2
1
2
3 4 5 6
12 11 10 9 8 7
13 14 15 16 17 18 19 20 21
22 23 24 25 26 27 28
29
1.5x4
3x5
5x6
3x6
3x63x54x4
3x4 1.5x4
5x10
3x8
3-0-13
3-0-13
8-2-13
5-2-0
13-6-8
5-3-12
19-0-0
5-5-8
-0-10-4
0-10-4
3-0-13
3-0-13
8-2-13
5-2-0
13-6-8
5-3-12
19-0-0
5-5-8
1-1-143-3-133-5-83-3-139.0012
PlateOffsets(X,Y)-- [3:0-3-0,0-2-2]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.63
0.70
0.85
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.08
-0.20
0.04
(loc)
8-10
8-10
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 83 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-2-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)12=1137/0-6-0(min. 0-2-0), 7=1193/0-6-0(min. 0-2-4)
Max Horz12=131(LC 9)
Max Uplift12=-318(LC 12), 7=-388(LC 9)
MaxGrav12=1207(LC 2), 7=1374(LC 31)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-12=-1194/321, 2-3=-1337/379, 3-13=-2096/578, 13-14=-2097/578, 14-15=-2097/578,
4-15=-2099/578, 4-16=-1772/491, 16-17=-1772/491, 17-18=-1772/491, 5-18=-1772/491,
5-19=-1772/491, 19-20=-1772/491, 20-21=-1772/491, 6-21=-1772/491, 6-7=-1264/439
BOT CHORD 11-22=-386/1082, 22-23=-386/1082, 10-23=-386/1082, 10-24=-627/2097, 9-24=-627/2097,
9-25=-627/2097, 25-26=-627/2097, 8-26=-627/2097
WEBS 2-11=-328/1122, 3-10=-319/1180, 4-10=-418/265, 4-8=-374/129, 5-8=-605/324,
6-8=-547/1980
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
12=318, 7=388.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T37
TrussType
Jack-ClosedGirder
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:492019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-Y8ckiE34A_0cWDCnjklQDYHEo_kY1AO21hm3?xzZ09e
NOTES-
10) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 154 lb down and 207 lb up at 3-0-13, 80 lb down and 92 lb up at
5-2-0, 80 lb down and 92 lb up at 7-2-0, 80 lb down and 92 lb up at 9-2-0, 80 lb down and 92 lb up at 11-2-0, 80 lb down and 92 lb up at 13-2-0, 80 lb down and 92 lb
up at 15-2-0, and 80 lb down and 92 lb up at 17-2-0, and 88 lb down and 89 lb up at 18-5-4 on top chord, and 89 lb down at 3-0-13, 45 lb down at 5-2-0, 45 lb down at
7-2-0, 45 lb down at 9-2-0, 45 lb down at 11-2-0, 45 lb down at 13-2-0, 45 lb down at 15-2-0, and 45 lb down at 17-2-0, and 57 lb down at 18-5-4 on bottomchord.
The design/selection of suchconnection device(s)is the responsibility of others.
11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51, 2-3=-51, 3-6=-61, 7-12=-20
Concentrated Loads(lb)
Vert: 3=-104(B) 11=-52(B) 14=-48(B) 15=-48(B) 16=-48(B) 17=-48(B) 18=-48(B) 19=-48(B) 20=-48(B) 21=-66(B) 22=-29(B) 23=-29(B) 24=-29(B) 25=-29(B)
26=-29(B) 27=-29(B) 28=-29(B) 29=-35(B)
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T38
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:502019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-0L96va4ixI8T8MnzHRGfmlqJtO7Lml8CFLVdYNzZ09d
Scale=1:34.2
0-1-11W1
T1
T2
W5
B1W2
W3 W4 W5 W4
B2
1
2
3 4 5
10 9 8 7 6
11
12 13 14
1.5x4
4x4
5x6
3x43x44x4
1.5x4
4x10
3x8
4-4-13
4-4-13
11-6-11
7-1-13
19-0-0
7-5-5
-0-10-4
0-10-4
4-4-13
4-4-13
11-6-11
7-1-13
19-0-0
7-5-5
1-1-144-3-134-5-84-3-139.0012
PlateOffsets(X,Y)-- [2:0-1-0,0-1-12], [3:0-3-0,0-2-2]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
1.00
0.47
0.37
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.08
-0.21
0.01
(loc)
6-7
6-7
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 84 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W4: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied, except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)10=770/0-6-0(min. 0-1-8), 6=750/0-6-0(min. 0-1-12)
Max Horz10=171(LC 13)
Max Uplift10=-79(LC 13), 6=-166(LC 13)
MaxGrav10=861(LC 35), 6=1049(LC 35)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-10=-832/188, 2-11=-1015/145, 3-11=-949/161, 3-12=-1293/219, 12-13=-1294/219,
4-13=-1296/219, 4-14=-1294/218, 5-14=-1294/218, 5-6=-982/201
BOT CHORD 9-10=-285/315, 8-9=-229/803, 7-8=-229/803
WEBS 2-9=-107/802, 3-7=-148/564, 4-7=-811/245, 5-7=-236/1423
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-4 to 2-1-12,Interior(1) 2-1-12 to 4-4-13,Exterior(2) 4-4-13 to 8-7-12
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 10 except(jt=lb)
6=166.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T39
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:512019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-UXjU6w4KibGKmWM9r9nuIzMXLoUkVBrLU?FA4pzZ09c
Scale=1:35.7
0-1-11W1
T1
T2
W5
B1W2
W3
W4
W5 W4
B2
1
2
3 4 5
10 9 8 7 6
11
12
13 14 15
2x4
6x8
5x6
2x43x44x4
1.5x4
4x10
3x8
5-8-13
5-8-13
12-2-11
6-5-13
19-0-0
6-9-5
-0-10-4
0-10-4
5-8-13
5-8-13
12-2-11
6-5-13
19-0-0
6-9-5
1-1-145-3-135-5-85-3-139.0012
PlateOffsets(X,Y)-- [2:0-3-4,0-1-8], [3:0-3-0,0-2-2]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.82
0.40
0.41
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.06
-0.15
0.01
(loc)
6-7
6-7
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 89 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W4: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-4-12 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 9-1-12 oc bracing.
WEBS 1 Row at midpt 3-7
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)10=760/0-6-0(min. 0-1-8), 6=746/0-6-0(min. 0-1-11)
Max Horz10=211(LC 13)
Max Uplift10=-86(LC 16), 6=-169(LC 13)
MaxGrav10=875(LC 36), 6=1026(LC 35)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-10=-825/194, 2-11=-943/128, 11-12=-912/137, 3-12=-855/164, 3-13=-952/200,
13-14=-952/200, 4-14=-954/200, 4-15=-952/199, 5-15=-952/199, 5-6=-965/200
BOT CHORD 9-10=-383/478, 8-9=-248/722, 7-8=-248/722
WEBS 2-9=-114/648, 3-7=-130/292, 4-7=-740/224, 5-7=-203/1160
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-4 to 2-1-12,Interior(1) 2-1-12 to 5-8-13,Exterior(2) 5-8-13 to 9-11-12
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 10 except(jt=lb)
6=169.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T40
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:522019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-yjHsKG5yTvOBNgxMPsI7rAvfnBrOEdTUjf_kcGzZ09b
Scale=1:40.4
0-1-11W1
T1
T2
W6
B1
W2 W3
W4
W5
W6 W5
B2
1
2
3
4 5 6
11 10 9 8 7
12
13
14 15 16
3x4
3x4
5x6
2x43x4
4x4
3x4
1.5x4
4x8
3x5
7-0-13
7-0-13
12-10-11
5-9-13
19-0-0
6-1-5
-0-10-4
0-10-4
3-8-3
3-8-3
7-0-13
3-4-11
12-10-11
5-9-13
19-0-0
6-1-5
1-1-146-3-136-5-86-3-139.0012
PlateOffsets(X,Y)-- [4:0-3-0,0-2-2]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.97
0.37
0.51
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.06
-0.15
0.02
(loc)
10-11
10-11
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 98 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W5: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-7-6 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 9-6-8 oc bracing.
WEBS 1 Row at midpt 4-8
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)11=752/0-6-0(min. 0-1-9), 7=742/0-6-0(min. 0-1-10)
Max Horz11=251(LC 13)
Max Uplift11=-95(LC 16), 7=-173(LC 13)
MaxGrav11=934(LC 36), 7=996(LC 35)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-11=-336/136, 3-4=-801/190, 4-14=-714/194, 14-15=-715/194, 5-15=-716/194,
5-16=-714/193, 6-16=-714/193, 6-7=-941/207
BOT CHORD 10-11=-344/695, 9-10=-253/636, 8-9=-253/636
WEBS 3-11=-745/91, 4-10=-27/272, 5-8=-666/205, 6-8=-198/991
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-4 to 2-1-12,Interior(1) 2-1-12 to 7-0-13,Exterior(2) 7-0-13 to 11-3-12
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 11 except(jt=lb)
7=173.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T41
TrussType
Jack-Closed
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:532019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-QwrEXc6aEDW2?qWYyaqMNOSxzb9hz28eyJkH8izZ09a
Scale=1:42.8
0-1-11W1
T1
T2
W6
B1
W2 W3
W4
W5
W6 W5
B2
1
2
3
4 5 6
11
10 9 8 7
12
13
14 15 16
4x4
3x4
5x6
2x43x5
4x4
3x4
1.5x4
4x8
4x4
8-4-13
8-4-13
13-6-11
5-1-13
19-0-0
5-5-5
-0-10-4
0-10-4
4-4-3
4-4-3
8-4-13
4-0-11
13-6-11
5-1-13
19-0-0
5-5-5
1-1-147-3-137-5-87-3-139.0012
PlateOffsets(X,Y)-- [4:0-3-0,0-2-2]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.56
0.49
0.61
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.12
-0.31
0.02
(loc)
9-11
9-11
7
l/defl
>999
>720
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 104 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W5: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 9-0-15 oc bracing.
WEBS 1 Row at midpt 6-7, 4-8
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)11=744/0-6-0(min. 0-1-10), 7=736/0-6-0(min. 0-1-9)
Max Horz11=291(LC 13)
Max Uplift11=-102(LC 16), 7=-178(LC 13)
MaxGrav11=986(LC 36), 7=960(LC 35)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-11=-397/145, 2-12=-303/84, 3-13=-755/167, 4-13=-649/193, 4-14=-539/194,
14-15=-539/193, 5-15=-541/193, 5-16=-539/193, 6-16=-539/193, 6-7=-909/220
BOT CHORD 10-11=-371/737, 9-10=-371/737, 8-9=-256/584
WEBS 3-11=-731/87, 3-9=-268/187, 4-9=-38/337, 4-8=-278/98, 5-8=-592/186, 6-8=-206/877
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-4 to 2-1-12,Interior(1) 2-1-12 to 8-4-13,Exterior(2) 8-4-13 to 12-7-12
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
11=102, 7=178.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T42
TrussType
HalfHipGirder
Qty
1
Ply
2
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:552019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-NIz?yH7rmqmmE8gw4?sqTpXDGProRvVxPdDODbzZ09Y
Scale=1:51.6
0-1-11T1
T2
W8
B1
W1 W2
W3 W4
W5 W6 W7 W6
HW1
B2
1 2
3
4
5
6 7 8
14 13 12 11 10 9
19
20
21 22 23 24 25 26 27
6x12MT18H
5x12MT18H
6x12
4x6
8x8
3x5
3x6 8x8
4x8
10x10
1.5x4
12x12
8x8
3-5-4
3-5-4
6-2-15
2-9-10
9-8-13
3-5-15
14-2-11
4-5-13
19-0-0
4-9-5
-0-10-4
0-10-4
3-5-4
3-5-4
6-2-15
2-9-10
9-8-13
3-5-15
14-2-11
4-5-13
19-0-0
4-9-5
1-1-148-3-138-5-88-3-139.0012
PlateOffsets(X,Y)-- [6:0-8-0,0-1-4], [8:0-3-8,Edge], [9:Edge,0-3-8], [10:0-6-0,0-6-4], [12:0-3-8,0-6-4], [13:0-3-8,0-5-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.83
0.45
0.81
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.11
-0.25
0.03
(loc)
12-13
12-13
9
l/defl
>999
>894
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 310 lb FT= 20%
GRIP
185/144
185/144
LUMBER-
TOP CHORD2x4SPF 1650F 1.5E*Except*
T2: 2x4 HF/SPF No.2
BOT CHORD2x8SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W8,W6: 2x4SPF 1650F 1.5E,W5,W7: 2x4 HF/SPF No.2
SLIDER Left 2x6SP 2400F 2.0E 2-0-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-7-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 8-9
REACTIONS.(lb/size)9=8367/0-6-0(min. 0-3-9), 2=6791/0-6-0(min. 0-2-15)
Max Horz2=317(LC 12)
Max Uplift9=-1621(LC 9), 2=-1913(LC 12)
MaxGrav9=8554(LC 31), 2=7046(LC 32)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-4303/1163, 3-4=-8662/2436, 4-5=-8887/2290, 5-19=-7153/1596, 6-19=-7048/1618,
6-20=-4373/869, 7-20=-4375/868, 7-8=-4373/868, 8-9=-7593/1525
BOT CHORD 2-14=-2110/6675, 14-21=-2110/6675, 13-21=-2110/6675, 13-22=-1993/7114,
22-23=-1993/7114, 12-23=-1993/7114, 12-24=-1313/5577, 11-24=-1313/5577,
11-25=-1313/5577, 10-25=-1313/5577
WEBS 4-14=-503/192, 4-13=-31/782, 5-13=-1332/3061, 5-12=-2681/1224, 6-12=-1681/6243,
6-10=-2630/918, 7-10=-510/159, 8-10=-1701/8576
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-7-0 oc.
Bottomchordsconnected as follows: 2x8- 2 rowsstaggered at 0-4-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft exposed ; end verticalleft exposed; Lumber DOL=1.60 plate grip DOL=1.60
5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
6) Unbalancedsnowloads have been considered for this design.
7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
8)Provide adequate drainage to preventwater ponding.
9)All plates areMT20 plates unless otherwiseindicated.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
Continued on page 2
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T42
TrussType
HalfHipGirder
Qty
1
Ply
2
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:552019 Page2
ID:?kBZNna9Me1?QphcfV33moyQFve-NIz?yH7rmqmmE8gw4?sqTpXDGProRvVxPdDODbzZ09Y
NOTES-
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 9=1621, 2=1913.
12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
13) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 2672 lb down and 1449 lb up at 4-9-0, 1719 lb down and 396 lb up at
6-9-12, 1960 lb down and 385 lb up at 8-9-12, 1948 lb down and 357 lb up at 10-9-12, 1882 lb down and 294 lb up at 12-9-12, and 1805 lb down and 227 lb up at
14-9-12, and 1840 lb down and 259 lb up at 16-9-12 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
LOADCASE(S)Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-6=-51, 6-8=-61, 9-15=-20
Concentrated Loads(lb)
Vert: 21=-2535(F) 22=-1719(F) 23=-1960(F) 24=-1948(F) 25=-1882(F) 26=-1805(F) 27=-1840(F)
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T43
TrussType
Common
Qty
4
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:562019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-rVXNAd8TX8udsHE7eiN3?04XspFRAXD4eHyxl1zZ09X
Scale=1:24.9
T1 T1
B1
W1
1
2
3
4
5
6
13
14
15 16
17
18
3x4 3x4
1.5x4
4x4
4-2-0
4-2-0
8-4-0
4-2-0
-0-10-4
0-10-4
4-2-0
4-2-0
8-4-0
4-2-0
9-2-4
0-10-4
0-5-143-7-60-5-149.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MP
0.20
0.17
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.02
-0.02
0.00
(loc)
6-9
6-12
2
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 28 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)2=338/0-3-8(min. 0-1-8), 4=338/0-3-8(min. 0-1-8)
Max Horz2=98(LC 15)
Max Uplift2=-61(LC 16), 4=-61(LC 17)
MaxGrav2=385(LC 2), 4=385(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-13=-361/63, 13-14=-292/74, 14-15=-288/76, 3-15=-276/86, 3-16=-276/86,
16-17=-288/76, 17-18=-292/74, 4-18=-361/63
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-4 to 2-1-12,Interior(1) 2-1-12 to 4-2-0,Exterior(2) 4-2-0 to 7-2-0zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
T43GE
TrussType
Common SupportedGable
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:572019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-Jh5lNz95IR0UURpJBQuIYEclkCdnv??EsxiVHTzZ09W
Scale=1:24.9
T1 T1
B1
ST2
ST1 ST1
1
2
3
4
5
6
7
10 9 8
11 12
4x4
2x4 2x41.5x41.5x4
1.5x4
1.5x4
1.5x4
8-4-0
8-4-0
-0-10-4
0-10-4
4-2-0
4-2-0
8-4-0
4-2-0
9-2-4
0-10-4
0-5-143-7-60-5-149.0012
PlateOffsets(X,Y)-- [6:0-1-5,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.06
0.03
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
6
6
6
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 32 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 8-4-0.
(lb)-Max Horz2=-98(LC 14)
Max UpliftAll uplift 100 lb orless at joint(s) 2, 6 except 10=-103(LC 16), 8=-101(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 2, 6, 9, 10, 8
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-C Corner(3)-0-10-4 to 2-2-0,Exterior(2) 2-2-0 to 4-2-0, Corner(3) 4-2-0 to 7-2-0zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)Gablerequirescontinuous bottomchord bearing.
8)Gablestudsspaced at 2-0-0 oc.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 6 except
(jt=lb) 10=103, 8=101.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V01
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:582019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-nte7aJAj3l8L5bOVl7PX4R9uCcyUeRPN5bR2qvzZ09V
Scale=1:38.3
T1 W1
B1
ST3
ST2
ST1
1
2
3
4
5
9 8 7 62x4
9-7-13
9-7-13
9-7-13
9-7-13
7-2-149.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.14
0.07
0.10
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 45 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 9-7-13.
(lb)-Max Horz1=278(LC 16)
Max UpliftAll uplift 100 lb orless at joint(s) 6, 7, 8 except 9=-130(LC 16)
MaxGravAllreactions 250 lb orless at joint(s) 1, 6, 7, 8 except 9=286(LC 29)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-311/267
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-C Corner(3) 0-5-4 to 3-7-13,Exterior(2) 3-7-13 to 9-6-1zone;cantileverleft exposed ;
endverticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)All plates are 1.5x4MT20 unless otherwiseindicated.
6)Gablestudsspaced at 2-0-0 oc.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 6, 7, 8 except
(jt=lb) 9=130.
9) Non Standard bearingcondition. Reviewrequired.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V02
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:35:592019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-F4CVofALp3GCjlziJqwmdfhzX0HnNuyWKFBbMMzZ09U
Scale=1:39.8
T1 W1
B1
ST1
1
2
3
5 4
6
7
8
2x4
1.5x4
1.5x41.5x4
1.5x4
8-3-13
8-3-13
0-0-46-2-149.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.55
0.13
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 31 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)1=103/8-3-8(min. 0-1-8), 4=102/8-3-8(min. 0-1-8), 5=342/8-3-8(min. 0-1-8)
Max Horz1=231(LC 13)
Max Uplift1=-18(LC 12), 4=-54(LC 13), 5=-192(LC 16)
MaxGrav1=166(LC 30), 4=142(LC 29), 5=421(LC 29)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-6=-337/302, 6-7=-315/326, 2-7=-315/331
WEBS 2-5=-354/250
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 8-2-1zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 4 except(jt=lb)
5=192.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V03
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:002019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-jGmu??BzaMP2LvYutYS?AsEA7QeR6LLgZvw9uozZ09T
Scale=1:33.4
T1 W1
B1
ST1
1
2
3
5 4
6
7
8
2x4
1.5x4
1.5x41.5x4
1.5x4
6-11-13
6-11-13
0-0-45-2-149.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.37
0.10
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 25 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)1=50/6-11-8(min. 0-1-8), 4=110/6-11-8(min. 0-1-8), 5=293/6-11-8(min. 0-1-8)
Max Horz1=191(LC 13)
Max Uplift1=-29(LC 12), 4=-49(LC 13), 5=-164(LC 16)
MaxGrav1=110(LC 30), 4=149(LC 29), 5=361(LC 29)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-6=-307/288, 2-6=-292/293
WEBS 2-5=-306/221
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 6-10-1zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 4 except(jt=lb)
5=164.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V04
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:012019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-BSKGDLCcLgXvy374QFzEi4nJgqxwrpfpnZgiQEzZ09S
Scale=1:25.9
T1 W1
B1
1
2
3
4
5
6
2x4
1.5x4
1.5x4
5-7-13
5-7-13
0-0-44-2-149.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.45
0.28
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 18 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-7-13 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)1=179/5-7-8(min. 0-1-8), 3=179/5-7-8(min. 0-1-8)
Max Horz1=151(LC 13)
Max Uplift1=-13(LC 16), 3=-72(LC 16)
MaxGrav1=203(LC 2), 3=232(LC 29)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 5-6-1zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V05
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:022019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-geueQhDE6_fmaCiH_zUTFHJYpDIFaGvz0DPGzhzZ09R
Scale=1:19.1
T1
W1
B1
1
2
3
4
2x4
1.5x4
1.5x4
4-3-13
4-3-13
0-0-43-2-149.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.23
0.14
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 14 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-3-13 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)1=132/4-3-8(min. 0-1-8), 3=132/4-3-8(min. 0-1-8)
Max Horz1=112(LC 13)
Max Uplift1=-9(LC 16), 3=-53(LC 16)
MaxGrav1=149(LC 2), 3=171(LC 29)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 4-2-1zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V06
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:022019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-geueQhDE6_fmaCiH_zUTFHJXzDIZaEZz0DPGzhzZ09R
Scale=1:44.1
T1 T1
B1
ST2
ST1 ST1
B2
1
2
3
4
5
9 8 7 6
10
11
12 13
14
15
3x4
4x4
3x4
3x6 1.5x41.5x4
1.5x4
1.5x4
1.5x4
0-0-5
0-0-5
19-2-11
19-2-5
9-7-5
9-7-5
19-2-11
9-7-5
0-0-47-2-80-0-49.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.29
0.19
0.15
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 65 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 19-2-0.
(lb)-Max Horz1=180(LC 13)
Max UpliftAll uplift 100 lb orless at joint(s) 1 except 9=-229(LC 16), 6=-229(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7 except 9=496(LC 29), 6=496(LC 30)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 2-9=-371/267, 4-6=-371/267
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 9-7-5,Exterior(2) 9-7-5 to 12-7-5zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb)
9=229, 6=229.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V07
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:042019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-c10OrMEUebvUqWsf6OWxKiPuu1?E28aGTXuM1ZzZ09P
Scale=1:41.7
T1 T1
B1
ST2
ST1 ST1
B2
1
2
3
4
5
98 7 6
10
11
12 13
14
15
3x4
4x4
3x4
3x6 1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
0-0-5
0-0-5
16-6-11
16-6-5
8-3-5
8-3-5
16-6-11
8-3-5
0-0-46-2-80-0-49.0012
PlateOffsets(X,Y)-- [8:0-2-4,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.19
0.11
0.12
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 55 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 16-6-0.
(lb)-Max Horz1=154(LC 13)
Max UpliftAll uplift 100 lb orless at joint(s) 1 except 9=-191(LC 16), 6=-191(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7 except 9=406(LC 29), 6=406(LC 30)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 2-9=-312/228, 4-6=-312/228
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 8-3-5,Exterior(2) 8-3-5 to 11-3-5zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb)
9=191, 6=191.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V08
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:052019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-4DZn2iF6Pv1LRgQrf51Atwx4IRLZnbIPiBewZ?zZ09O
Scale=1:33.8
T1 T1
B1
ST2
ST1 ST1
1
2
3
4
5
8 7 6
9
10
11 12
13
14
3x4
4x4
3x4
1.5x41.5x4
1.5x4
1.5x4
1.5x4
0-0-5
0-0-5
13-10-11
13-10-5
6-11-5
6-11-5
13-10-11
6-11-5
0-0-45-2-80-0-49.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.15
0.10
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 44 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.All bearings 13-10-0.
(lb)-Max Horz1=-127(LC 14)
Max UpliftAll uplift 100 lb orless at joint(s) 1 except 8=-163(LC 16), 6=-163(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 1, 5 except 7=252(LC 2), 8=339(LC 29), 6=339(LC 30)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 2-8=-273/202, 4-6=-273/202
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 6-11-5,Exterior(2) 6-11-5 to 9-11-5zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb)
8=163, 6=163.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V09
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:052019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-4DZn2iF6Pv1LRgQrf51Atwx?KRJXnbKPiBewZ?zZ09O
Scale=1:27.4
T1 T1
B1
ST1
1
2
3
4
5
6
7 8
9
10
3x4
4x4
3x4
1.5x4
11-2-5
11-2-5
11-2-11
0-0-5
5-7-5
5-7-5
11-2-11
5-7-5
0-0-44-2-80-0-49.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.47
0.23
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 32 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)1=201/11-2-0(min. 0-1-8), 3=201/11-2-0(min. 0-1-8), 4=330/11-2-0(min. 0-1-8)
Max Horz1=-101(LC 12)
Max Uplift1=-56(LC 16), 3=-69(LC 17)
MaxGrav1=231(LC 2), 3=231(LC 2), 4=366(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 5-7-5,Exterior(2) 5-7-5 to 8-7-5zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V10
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:062019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-YQ79G2GkAC9C3q?2DoYPP7UEargOW3AYxrNT6SzZ09N
Scale=1:22.1
T1 T1
B1
ST1
1
2
3
4
5
6
7
8
2x4
4x4
2x41.5x4
0-0-5
0-0-5
8-6-11
8-6-5
4-3-5
4-3-5
8-6-11
4-3-5
0-0-43-2-80-0-49.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.25
0.13
0.05
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 24 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)1=149/8-6-0(min. 0-1-8), 3=149/8-6-0(min. 0-1-8), 4=245/8-6-0(min. 0-1-8)
Max Horz1=-75(LC 12)
Max Uplift1=-42(LC 16), 3=-51(LC 17)
MaxGrav1=171(LC 2), 3=171(LC 2), 4=272(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 4-3-5,Exterior(2) 4-3-5 to 7-3-5zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V11
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:072019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-0chXTOHMxWH3h_aEnW4eyL1ReE2nFWkiAV70euzZ09M
Scale:3/4"=1'
T1 T1
B1
ST1
1
2
3
4
2x4
4x4
2x41.5x4
0-0-5
0-0-5
5-10-11
5-10-5
2-11-5
2-11-5
5-10-11
2-11-5
0-0-42-2-80-0-49.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.10
0.06
0.03
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-10-11 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)1=98/5-10-0(min. 0-1-8), 3=98/5-10-0(min. 0-1-8), 4=160/5-10-0(min. 0-1-8)
Max Horz1=49(LC 15)
Max Uplift1=-27(LC 16), 3=-34(LC 17)
MaxGrav1=112(LC 2), 3=112(LC 2), 4=178(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V12
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:082019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-UoFvhkH?iqPwI79QLDbtUYZddeN0_zOrO9saAKzZ09L
Scale=1:8.8
T1 T1
B1
1
2
3
2x4
3x4
2x4
0-0-5
0-0-5
3-2-11
3-2-5
1-7-5
1-7-5
3-2-11
1-7-5
0-0-41-2-80-0-49.0012
PlateOffsets(X,Y)-- [2:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.02
0.06
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 7 lb FT= 20%
GRIP
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-2-11 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)1=83/3-2-0(min. 0-1-8), 3=83/3-2-0(min. 0-1-8)
Max Horz1=23(LC 13)
Max Uplift1=-12(LC 16), 3=-12(LC 17)
MaxGrav1=94(LC 2), 3=94(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V13
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:092019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-y?pHu4IdT7XnwHkdux661m6k12hjjQn?dpc7inzZ09K
Scale=1:23.7
T1 T1
B1
ST1
1
2
3
4
5
6
7 8
9
10
2x4
4x4
2x41.5x4
0-0-5
0-0-5
9-3-0
9-2-11
4-7-8
4-7-8
9-3-0
4-7-8
0-0-43-5-100-0-49.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.30
0.15
0.05
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 26 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)1=163/9-2-5(min. 0-1-8), 3=163/9-2-5(min. 0-1-8), 4=267/9-2-5(min. 0-1-8)
Max Horz1=-82(LC 12)
Max Uplift1=-45(LC 16), 3=-56(LC 17)
MaxGrav1=187(LC 2), 3=187(LC 2), 4=297(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 4-7-8,Exterior(2) 4-7-8 to 7-7-8zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V14
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:102019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-RBNg6QJFERfeYRJpSedLazfxOS2EStP8sSLhFDzZ09J
Scale=1:17.6
T1 T1
B1
ST1
1
2
3
4
2x4
4x4
2x41.5x4
0-0-5
0-0-5
6-7-0
6-6-11
3-3-8
3-3-8
6-7-0
3-3-8
0-0-42-5-100-0-49.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.13
0.07
0.03
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 18 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)1=111/6-6-5(min. 0-1-8), 3=111/6-6-5(min. 0-1-8), 4=182/6-6-5(min. 0-1-8)
Max Horz1=56(LC 13)
Max Uplift1=-31(LC 16), 3=-38(LC 17)
MaxGrav1=127(LC 2), 3=127(LC 2), 4=202(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard
DE Job # 64866-W1
Dansco Engineering, LLC
Date: 3/21/19
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of
the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and
TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Job
1903481-12T
Truss
V15
TrussType
Valley
Qty
1
Ply
1
1903481-12TDWHWoodsideatW.C.13
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.WedMar2015:36:112019 Page1
ID:?kBZNna9Me1?QphcfV33moyQFve-vNx2JmKt?lnV9bu?0M8a6BB8dsO5BK7H465EnfzZ09I
Scale=1:10.1
T1 T1
B1
1
2
3
2x4
3x4
2x4
3-10-11
3-10-11
3-11-0
0-0-5
1-11-8
1-11-8
3-11-0
1-11-8
0-0-41-5-100-0-49.0012
PlateOffsets(X,Y)-- [2:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.03
0.10
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 9 lb FT= 20%
GRIP
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-11-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS.(lb/size)1=108/3-10-5(min. 0-1-8), 3=108/3-10-5(min. 0-1-8)
Max Horz1=30(LC 13)
Max Uplift1=-15(LC 16), 3=-15(LC 17)
MaxGrav1=122(LC 2), 3=122(LC 2)
FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S)Standard