HomeMy WebLinkAboutGN - Van Buren 69JG Sewer PermitIUlu] N. college Avenue Suite A Indianapolis, Indiana 46280 phone 317-844-9200 fax 317-844-9203 www.trico.eco
Residential
SANITARY SEWER PERMIT
999913201
Permit Type
Final
Subdivision
Jacksons Grant
Project WO
ENG22015
Section Number
1 B
Project Name
Jacksons Grant 1B
Lot Number
69
Project Developer
JG Development Co, LLC
Address Number
493
Lift Station
26 Jacksons Grant
Address 2
Treatment Plant
MIX
Street
Jacksons Grant Blvd
Parcel Acreage
0.27
City
Carmel
EDU in Gallons
310
Zip Code
46032
County
Hamilton
Local Sewer Charge - District Contribution 0.00
Builder
Old Town Design Group
Plan Review and Inspection
0.00
--
- - - - - - -- -
Application Fee
150.00
Phone Number
317-605-8796
EDU Fee
1908.00
Owner
Interceptor Fee
0.00
Phone Number
Other Fees
0.00
Fees Due
2058.00
Occupant
Invoice Number
Phone Number
PLEASE NOTE: Installation of building sewer shall be per the specifications of the TdCo Regional Sewer Utility (see
reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench"
phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, or other
sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TriCo will assume no
liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are
extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be
responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and
the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by TriCo are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in
advance. All new construction will be placed on billing two months after connection has been made or when water is
connected, whichever comes first.
The building has:
Main ID:
JG851-JG888
Grease Trap Slab Foundation
Grease Interceptor Crawl Space
ManholelDs USMH
JG -851 JG-888
Grit Interceptor Basement YES
Lid Elevation
857.74
�DS-MHH
857.36
Grinder Station
First Floor Elevation
859.50
859.50
Water Service City of Carmel
Basement Elevation
849.50
849.50
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor
j ,761 2.14 Ft.
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by:
Ejector Pump Only
TriCo currently requires that an I&I inspection is performed and a Certificate of Compliance is issued prior to occupancy /
sale of a propenty. Please review attached 1/1 Permit.
Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure.
The terms of the conditional permit, if any, are listed below.
Plans have been submitted. oNAI sE
All fees have been paid.
No certificate of insurance required.
No additional permits required.
No manhole core permit required. L I . tj
The facility is not classified as a FOG facility.
(Notes)
E o
o?
P
-HAMII.ZON �
By signing below, I attest that I am fa iliar 'th the Dis 's pe i cations and agree to accept responsibility for all work done under this permit.
Builder / Owner Signature `_ Phone Number (% _ o l a i!02 JO
Printed Name �_IY-n 1 tf fMA/1
Approved By -AA
RyanNan, Distract Engineer 03/18/2019
Permit is valid r OIC -YEAR from the date issued. Permit valid only with TriCo seal in red ink.