Loading...
HomeMy WebLinkAboutA309 Common Interior Wall SectionsProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateHolland / Playfair BuildingsCarmel, IN 46032880 West Monon Green Blvd.PEDCOR DESIGN GROUP LLC A309 Common Interior Wall Sections THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2018 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 09.28.2018 JAWJLS, JAW 9/28/2018 Revision ID Issue Date Issue Name Change Name Change ID 01 02 9/28/18 2/26/19 Construction Set ADDENDUM 5 Draftstop clarification 15 1 1 2 2 3 3 4 4BIMcloud: BIM AC22 - BIMcloud Basic for ARCHICAD 22/Holland Playfair/PlayLandC4 A004 10'-9 1/2"10'-8"10'-8"8'-11 5/8"VARIES9'-1 1/4"1'-6 3/4"9'-1 1/4"1'-6 3/4"9'-1 1/4"1'-6 3/4"9'-1 1/8"9'-1 1/4"1'-6"3/4"1 1/2"8'-11 3/4"1'-6"3/4"1 1/2"8'-11 3/4"1'-6"3/4"1 1/2"8'-10 1/2"1 1/8"15'-10 1/2" 26'-6 1/2" 37'-2 1/2" 47'-10 1/2" 56'-11 5/8" POST TENSIONED SLAB, REF. S-SERIES DWGS., TYP. 5/8" FIRE RESISTANT GYP. BD. ON RESILIENT CHANNELS @ 12" O.C.. R-13HD BATT INSULATION 5/8" GYP. BD. OVER WOOD STUD FRAMING, REF. APARTMENT UNIT PLANS R-11 BATT INSULATION R-11 BATT INSULATION APARTMENTAPARTMENT HEAD OF WALL FIRE STOPPING 1 HOUR RATED CONTINUOUS 1 1/2" ACCOUSTIC TOPPING, REF. SHT. A520 FOR ACOUSTIC TOPPING DETAILS HEAD OF WALL FIRE STOPPING 1 HOUR RATED CONTINUOUS R-11 BATT INSULATION HEAD OF WALL FIRE STOPPING 1 HOUR RATED CONTINUOUS HEAD OF WALL FIRE STOPPING 1 HOUR RATED CONTINUOUS 3/4" PLYWOOD DRAFTSTOP APARTMENTAPARTMENT APARTMENTAPARTMENT APARTMENTAPARTMENT DRAFTSTOPPING REQUIRED BETWEEN WALL WYTHES EACH WAY. SPACING EACH WAY OF MATERIAL IS 10' MAX. DRAFTSTOPPING REQUIRED BETWEEN WALL WYTHES EACH WAY. SPACING EACH WAY OF MATERIAL IS 10' MAX. 2x4 WOOD STUDS @ 16" O.C., REFERENCE S- SERIES DRAWINGS FOR DIAPHRAM SHEATHING. 5/8" GYP. BD. OVER WOOD STUD FRAMING IN ROOF FRAMING SPACE. REFERENCE NOTES BELOW FOR EACH FLOOR. REFERENCE NOTES BELOW FOR EACH FLOOR. REFERENCE NOTES BELOW FOR EACH FLOOR. 2x4 WOOD STUD FRAMING, REFERENCE S - SERIES DRAWINGS. DIAPHRAGM SHEATHING PER S-SERIES DRAWINGS. C1/ A004 C1/ A004 A1/ A004 C1/ A004 A2/ A004 A2/ A004 C1/ A004 C1/ A004 C1/ A004 C1/ A004 A1/ A004 C1/ A004 B1 A004 15'-10 1/2" 26'-6 1/2" 37'-2 1/2" 47'-10 1/2" 56'-11 5/8" POST TENSIONED CONCRETE SLAB, REF. S- SERIES DWGS., TYP. R-21HD BATT INSULATION R-11 BATT INSULATION 1 1/2" ACCOUSTIC TOPPING, REF. SHT. A520 FOR ACOUSTIC TOPPING DETAILS R-21HD BATT INSULATION R-11 BATT INSULATION 5/8" FIRE RESISTANT GYP. BD. ON RESILIENT CHANNELS - REFERENCE THE UL LISTINGS IN THE SET FOR TYPE AND SPACING. R-11 BATT INSULATION R-11 BATT INSULATION ROOF TRUSSES, REF. S- SERIES DWGS. CORRIDOR APARTMENT R-11 BATT INSULATION R-11 BATT INSULATION R-11 BATT INSULATION R-11 BATT INSULATION CORRIDOR CORRIDOR APARTMENT CORRIDOR APARTMENT APARTMENT T / WALL TRUSS BEARING INSULATED WOOD STUD WALL, REF. S-SERIES DWGS FOR FRAMING AND DIAGRAM SHEATHING. WHERE DIAPHRAM SHEATHING DOES NOT OCCUR, USE 1/2" RC CHANNEL SPACED 12" OC. DRYWALL MUST PASS THROUGH TO CEILING FIRE STOPPING REQUIRED AT CEILNG TO WALL CAVITY. DRYWALL MUST PASS THROUGH TO CEILING FIRE STOPPING REQUIRED AT CEILNG TO WALL CAVITY. LOAD BEARING WALL SIDE OF CORRIDOR WITH RC CHANNEL. SHEAR WALL SIDE OF CORRIDOR, REFERENCE S- SERIES DRAWINGS. LOAD BEARING WALL SIDE OF CORRIDOR WITH RC CHANNEL. SHEAR WALL SIDE OF CORRIDOR, REFERENCE S- SERIES DRAWINGS. T / WALL TRUSS BEARING T / WALL TRUSS BEARING T / WALL TRUSS BEARING B1/ A004 C1/ A004 B1/ A004 C1/ A004 A1/ A004 B1/ A004 C1/ A004 A2/ A004 A2/ A004 REFERENCE NOTES BELOW FOR EACH FLOOR. REFERENCE NOTES BELOW FOR EACH FLOOR. REFERENCE NOTES BELOW FOR EACH FLOOR. C4b/ A004 C4a/ A004 C4b/ A004 C4a/ A004 C4b/ A004 C4a/ A004 C4b/ A004 C4a/ A004 DRAFTSTOP BOARD REQUIRED, TYPICAL. CAN BE 7/16" OSB LIKE STRUCTURAL SHEATHING IN DETAIL 13/S551 OR BUILDING CODE ALLOWABLE BOARD FROM SECTION 718.2.1, 2012 IBC (LESS OPTIONS 7 & 8). STRUCTURAL SHEATHING AND DRAFTSTOP BOARD REQUIRED, TYPICAL AT SHEARWALL SIDE. REFERENCE DETAIL 13/S551. STRUCTURAL SHEATHING AND DRAFTSTOP BOARD REQUIRED, TYPICAL AT SHEARWALL SIDE. REFERENCE DETAIL 7/S553. A3 A310 1'-0"10'-8"1 1/2"10'-6 1/2"1 1/2"10'-6 1/2"1 1/2"1'-0"9'-1 1/4"1'-6"2 1/4"8'-11 3/4"1'-6"2 1/4"8'-11 3/4"1'-6"2 1/4"8'-11 5/8"2'-1 1/2"5'-0"15'-10 1/2" 26'-6 1/2" 37'-2 1/2" 47'-10 1/2" 56'-11 5/8" STRUCTURAL SLAB, REF. S- SERIES DWGS., TYP. R-11 BATT INSULATION ROOF TRUSSES, REF. S- SERIES DWGS. 1 1/2" ACCOUSTIC TOPPING, REF. SHT. A520 FOR ACOUSTIC TOPPING DETAILS 1 1/2" ACCOUSTIC TOPPING, REF. SHT. A520 FOR ACOUSTIC TOPPING DETAILS 5/8" FIRE RESISTANT GYP. BD. ON RESILIENT CHANNELS @ 12" O.C. 2 HOUR SHAFT 3 5/8" CFS CEILING FRAMING (NOT SUSPENDED GYP. CEILING) R-11 BATT INSULATION CORRIDOR APARTMENT HEAD OF WALL FIRE STOPPING 2 HOUR RATED CONTINUOUS T / WALL TRUSS BEARING SHAFT LINER WALL SYSTEM, 4" CFS STUDS. CORRIDOR APARTMENT CORRIDOR APARTMENT CORRIDOR APARTMENT NER 258 ASSEMBLY, 2 HOUR AT ALL 2ND FLOOR SLAB PENETRATIONS. 2 LAYERS GYP BD CONTINUOUS THROUGH FLOOR/CEILING SYSTEM. H.M. DOOR AND FRAME FOR SHAFT ACCESS. LOCATED ON 3RD AND 5TH FLOORS. FIRE CAULK CONTINUOUS AROUND FLOOR PENETRATION, TYPCAL AT ALL FLOORS. FIRE CAULK CONTINUOUS AROUND CEILING PENETRATIONS, TYPICAL AT ALL FLOORS. GIRDER TRUSS, REFERENCE S-SERIES DRAWINGS WOOD LEDGERS, GIRDER TRUSS AT WALLS PERPENDICULAR TO TRUSSES. REFERENCE S- SERIES DRAWINGS REFERENCE NOTES BELOW FOR EACH FLOOR. REFERENCE NOTES BELOW FOR EACH FLOOR. REFERENCE NOTES BELOW FOR EACH FLOOR. 5/8" FIRE RESISTANT GYP. BD. ON RESILIENT CHANNELS @ 12" O.C. MECHANICAL CURB AND COVER, REFERENCE THE M & H SERIES DRAWINGS. B1/ A004 A1/ A004 A2/ A004 A2/ A004 C1/ A004 C1/ A004 C1/ A004 B1/ A004 B1/ A004 B4 A004 1'-0"10'-9 1/2"10'-8"10'-8"1'-0"8'-11 7/8"1 3/8"1'-6"3/4"1 1/2"8'-10 3/8"1 3/8"1'-6"3/4"1 1/2"8'-10 3/8"1 3/8"1'-6"3/4"1 1/2"8'-10 1/2"1 1/8"1'-0"9'-1 1/4"1'-6"3/4"9'-1 1/4"1'-6"3/4"9'-1 1/4"1'-6"3/4"9'-1 1/8"Varies15'-10 1/2" 26'-6 1/2" 37'-2 1/2" 47'-10 1/2" 56'-11 5/8" COMPOSITE SLAB, REF. S- SERIES DWGS., TYP. 5/8" FIRE RESISTANT GYP. BD. ON RESILIENT CHANNELS @ 12" O.C. PER 1 1/2" ACCOUSTIC TOPPING, REF. SHT. A520 FOR ACOUSTIC TOPPING DETAILS R-11 BATT INSULATION 1 1/2" ACCOUSTIC TOPPING, REF. SHT. A520 FOR ACOUSTIC TOPPING DETAILS 5/8" FIRE RESISTANT GYP. BD. ON RESILIENT CHANNELS @ 12" O.C. PER UL LISTING ON SHEET A0 SERIES SHEETS. R-11 BATT INSULATION 5/8" GYP. BD. OVER STRUCTURAL SHEAR PANELS. REFERENCE S-SERIES DRAWINGS. R-11 BATT INSULATION HEAD OF WALL FIRE STOPPING 1 HOUR RATED CONTINUOUS R-11 BATT INSULATION HEAD OF WALL FIRE STOPPING 1 HOUR RATED CONTINUOUS REFER TO S-SERIES DWGS. FOR SHEAR WALL DESIGN. (THE AREA SEPARATION WALL ONLY ALLOWS THE SHEATHING TO BE PACES AT THE OUTER SIDE (APARTMENT SIDE). 1" UNDERLAYMENT OVER 3/8" SOUND ISOLATION MAT & 3/4" PLYWD. DECK TYP. ALL FLOORS 2x4 WOOD STUDS. REFERENCE S-SERIES DRAWINGS FOR SPACING REFERENCE S-SERIES DRAWINGS FOR PRE-FAB. BLOCKING PANELS. FIRE AND DRAFT STOPPING REQUIRED. REVIEW SPECIAL INSTRUCTIONS IN THE S-SERIES DRAWINGS.R-11 MINERAL WOOL INSULATION REFERENCE NOTES BELOW FOR EACH FLOOR. REFERENCE NOTES BELOW FOR EACH FLOOR. REFERENCE NOTES BELOW FOR EACH FLOOR. C1/ A004 C1/ A004 A1/ A004 C1/ A004 A2/ A004 A2/ A004 C1/ A004 C1/ A004 C1/ A004 02 15 02 15 02 15 0 1'2'4'SCALE: 1/2" = 1'-0"A1 Demising Wall Section 0 1'2'4'SCALE: 1/2" = 1'-0"A2 Corridor Wall Section 0 1'2'4'SCALE: 1/2" = 1'-0"A3 Shaft Wall Section 0 1'2'4'SCALE: 1/2" = 1'-0"A4 Fire Wall Section