HomeMy WebLinkAboutMHEAT PUMP, AIR HANDLING ANC HEATING EOJIPMENT SCHEDULE DE5CRIP7ION SUPPLY FAN COOLING HEATING FILTERS CONDENSER SECTION ELECTRICAL COOL UNIT MARK MANF. MODEL NUMBER TOTAL G.F.M. O.A. G.F.M. ESP MOTOR H.P. E.A.T. MBH TYPE OUTPUT MBH S' ST& TYPE THK. O.A. TEMP LOW O.A. CONDENSERt15 PRESSOR VLT PH MCA BKR TON WEIGHT DB WB TH SH AREA FAN H KW STEPS BTU 1 TRANE YHC048F3# A0000 1,600 20% 0.8 3/4 T-A (1) 1 70 36 11,98 2510,1 1 208 3 28.3 40A 4.0 869 67 80 50 42 96 / 80 2 L ELI I ES: 1. ALL UNITS TN HAVE ECONOMIZER PROVIDED S INSTALLED. KIM IL! 2. ALL UNITS SHALL BE SET IN DRIP PAN W/ DRAIN LINE TO EXTERIOR OF BUILDING. SPECIFIC CHART VALUES ARE FOR REFERENCE ONLY 3. ALL UNITS SHALL BE COMPLETE WITH 7-DAY ELECTRONIC FULLY PROGRAMMABLE THERMOSTAT w/ LOCKABLE COVER ALL PERFORMANCE SHALL BE VERIFIED AGAINST EXISTING EQUIPMENT INSPECTIONS 4. ALL UNITS SHALL BE EQUIPPED WITH SMOKE DETECTOR IN RETURN AIR DUCT, PRIOR TO ENTERING UNIT, VOLUME DAMPER SG THAT IN THE EVENT OF FIRE, DETECTOR SHALL DEACTIVATE BLOWER MOTOR & SOUND ALARM. 5. COIL SHALL BE CONNECTED TO SAIL SWITCH IN RETURN AIR DUCT SO THAT IN THE EVENT BLOWER MOTOR IS DEACTIVATED, COIL SHALL BE DEACTIVATED AS WELL, TO PREVENT 'FREEZE-UP'. EXHAUST PAN SCHE:r%LE: MARK MANUFACTURER MODEL NUMBER CFM DUCT SIZE APPROX. SP MAX. SONE LEVEL MOTOR VOLTS PHASE REMARKS RPM HP OF 1 BROAN HDBOL 75 40 0,125 80 1500 1/8 115 1 II NLJ I t_S 1, DUCTS TO BE COMBINED AS SHOWN, 2, TIE ACTIVATION OF FAN INTO LIGHT SWITCH FOR SIMULATENOUS OPERATION OF FAN AND LIGHTS H\/AG GENERAL= NOTES: I. The heating, air conditioning equipment and installation shall conform to all current National, State and Local Godes. 2. The Mechanical Contractor to clearly label each unit by area served using I" stencil or engraved plastic. B. The Mechanical Contractor shall coordinate supply air and return air ducts with General Contractor so duct encasements may ber installed at the proper locations as not to affect the y P lc structural system of the building. 4. The Mechanical Contractor Is to coordinate gas piping with Plumbing Contractor to assure correct size and final locations of the units, and piping servicing the units. Piping in attlo, to be suspended from trusses a minimum of 12" above Insulation for proper leak test and future service and Inspection. The M.G. to verify all aspects of gas service with local utility. 5. The Mechanical Contractor shall be responsible for pouring concrete pad For units. Chits to be 30" clear of building or at manufacturer's recommendations, which ever Is greater. 6. The Mechanical Contractor shall coordinate all electrical requirements of all units with the Electrical Contractor to assure final correct locations of the unit's disconnects. All equipment to be provided with Internal fuse protection, per N.E.G., State and locol Codes. T. All Exhaust Fans and Ventilators shall have back draft dampers. Units provided and Installed by the Mechanical Contractor, power and wiring by the Electrical Contractor. 0. Ductwork shall be Insulated. See Ductwork General Ni 9. The Mechanical Contractor to provide 3/4" PVG condensate drains with slope to positive drainage outside of building. Provide sheet metal auxiliary drain pan, at attic units, 2" deep under each cooling coil. Provide 5/4" condensate drain separated from cooling coil drain. Slope to positive drain with straps at 45" o.c. to ovoid sagging of lines. Pitch auxiliary drain pans and cooling coils slightly In direction of condensate flow. 10. The Mechanical Contractor shall install fire dampers In all ducts passing through Fire Rated Walls and Ceilings (denoted as "F I' on these Drawings) and all other locations specified by the State Fire Marshall or Authority Having Jurlsdictlon. 11. Mechanical equipment shall be base bid as 3m power supply. Mechanical contractor shall be responsible for verifying available power supply prior to ordering and Installing equipment. 12. The Mechanical Contractor to provide and install specified control devices and Law Voltage Wiring. Thermostats to be Fully Programmable 7 Day. Provide "tamperprooF" Govern with lock for all thermostats. B. Fresh / Outslde Air shall conform to A51PRAE 62 'Ventilation For Acceptable Indoor Air Quality" and all State and Locol Codes. 14. SEER. / E.E.R. - as rated in accordance with 0.5. Government D.O.E. Test procedure and A.R.I. Standard 210-19. 15. A.F.U.E. - Annual Fuel Utilization Efficiency as established by U.S. Government Standard D.O.E. Test. RELEASED FOR CONSTRUCTION `""art prior Subject to romp Dew ith all regulations of State and Local Codes THESE NOTES SHALL APPLY UNLESS OTHERWISE INDICATED BY DRAWINGS OR SPECIFICATIONS. I Duct dimensions are shown as clear Inside dimensions. Mere internal insulation is Dolled for, dimensions shell be increased by the thickness of InSUlatlon. 2 Portions of ducts visible through diffusers, grilles and registers in finished areas shall be painted flat black. 5 coordinate exact locations of all selling diffusers, registers and exhaust grilles, ductwork, etc. with lighting layout, reflected ceiling plan and owner's layout, so they will remain unobstructed. 4 Coordinate all duct penetrations with Structural Drawings. 5 Supply and return ducts shall be sheet metal with I" thick Internal acoustical lining. -OR- hred all supply and return ductwork with 2" thick, 3/4 Is. density foil faced insulation. -OR- Where applicable, Owens Corning I" fiberglass duct board. 6 All ductwork shall be fabricated and installed in accordance with 5MAGNA Duct Manual and URFA 90-A. T Flexible ductwork not to exceed 6'. When longer runs occur, use 26 Ga. round ductwork to obtain requlred lengths. 5 Provide flexible connection where supply and return air ducts connect to unit, cl Ductwork openings shall be coordinated with MEd,[ for Inetallotlon by this Contractor. The M.G. to provide ductwork for exterior, insulated and weather -protected and Install return air ductwork as required. 10 These al l q5 Indicate duct for size and approximate location. Ducts may need to be moved slightly to Insure no obstruction In Installation. DUCT BRANCH FLEX DUCT SUSPENDED ACOUSTICAL CEILING PANEL DIFFUSER SUPPORT STRAP HANGERS (TYPJ MAXIMUM ALLOWABLE LENGTH OF FLEX. DUCT 10'-0" O.B. DAMPER INSULATION NOTE: FLEX DUCT TO BE SAME SIZE AS DIFFUSER NECK. fi`wi� FLEX DUCT : EETAL NOT TO A A SQUARE ELBOW IS PERMISSIBLE ONLY WHERE SHOWN ON DRAWINGS OR BY REQUEST W R=W W R-W R R=W W PERMISSIBLE ELBOWS O R AIR FLOW AIR FLOW w - - R=W o 20° MAX. ON DIVER&INIS 300 MAX. ON CONVER&IN& PERMISSIBLE TRANSITIONS AIR FLOW AIRFLOW pS FS ROUND TO ROUND RECTANbULAR TO ROUND RECTAN&ULAR TO RECTAN&ULAR PERMISSIBLE DUCT BRANCH TAKEOFF 7YPIGALE ELE30 $ 7RAN5MON r�)E7,ii NOT TO SCALE: MECHANICAL SYMBOL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION ® CEILING SUPPLY DIFFUSER ( SAD ) S-12x8 SUPPLY DUCT - WIDTH x DEPTH 0 ROUND CEILING SUPPLY DIFFUSER ( SAR ) R-12x8 RETURN DUCT - WIDTH x DEPTH ® CEILING SUPPLY GRILLE ( SAG ) ® SQUARE / RECTANGLE SUPPLY DUCT SECTION ® CEILING / FLOOR SLOT DIFFUSER ( SAS ) ROUND SUPPLY DUCT SECTION T1 WALL SUPPLY GRILLE ( SAG ) L] SQUARE / RECTANGLE RETURN DUCT SECTION CEILING RETURN EGG -CRATE REGISTER ( MAD ) ROUND RETURN DUCT SECTION r-t WALL RETURN GRILLE ( RAG) ® SQUARE -TO -ROUND TRANSITION RFD FIRE DAMPER ® FAN EXHAUST FAN ­­1 VD VOLUME DAMPEREXH ®L FAN EXHAUST FAN WITH LIGHT No MOTORIZED DAMPER _E-6x4 _ EXHAUST DUCT - WIDTH x DEPTH (C�10 THERMOSTAT WITH UNIT I.D. CONTROLLED [] EXHAUST WALL CAP CityofCamele at wv mmDOe"mmlmmOrtlew"P",u�,"r,."nm,=.m y Oftkr.id bmium. tm,l aim a rcrn,a.,,"mwm:.,: m m� I.iwnmu,mn,mnw n"uemmiwm,i =rat,&r1midO ne:m"r.,."amri m, md )11{) �l ®:uy wlwa":&Wren all work mwo-m a mu wrtumm"a,m .e m:w,:m" mn:.":..xml mmmx,n e,m. aaomam: m, DATE: 04/22/19 O,nd M.PiOrin..mz ISSUE: HANGER STRAPS SPACING TO BE 8'-0' MAX. 3" OVERLAP c/w (2) 1/V°0 BOLT FASTENERS — V x 18 ga GALV, SHEET METAL STRAP c/w (1) 1/4"0 BOLT RATED FASTENER w/o DISFIGURING SHAPE, UP TO 18"0 DUCT ROUND DUCT DETAIL EXHAUST DUCT UP THRU ROOF WITH GAP 6`0 III (u� I� N I R-20X14 2OX14 DROP FROM NIT 16XI6 DROP FROM UNIT SAD 400 3' OVERLAP c/w (2) 3/8'0 BOLT FASTENERS, FOR DUCT OVER 18'0 1 Va°x16 ga GALV SHEET METAL STRAP w/o DISFIGURING SHAPE ) BLANKET INSULATION SEALED \ VAPOR TIGHT c/w MASTIC & FABRIC TAPE 4' WIDE YFIG�t� 1U�7 5UFFOR7 �E:Tfi NOT TO SCALE; MECHANICAL FLAN SCALE: 3/I6" = I'-0" _+ rin.e: SHEET: MECHANICAL FLANS ANC will U N U ,id� 4 IN W a w 11 o h //�� PiH Q to d On e �U z C O e U Q: se N t. L 51111 ix O � AND M S A M Aa�i,� W JW a rd E NATURED/ — CBD — PH: