Loading...
HomeMy WebLinkAbout19040118 State ReleaseELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 1/2 CONSTRUCTION DESIGN RELEASE State Form 41191 (R9/5-98) Report Printed on:April 10, 2019 Project number Release date 407023 04/10/19 Construction type Occupancy classification Scope of release II-B B, S-1 Type of release Project name Street address City County ARCH ELEC MECH PLUM STR Standard Naturely CBD Oil Store 11036 N Michigan Rd Suite 110 CARMEL HAMILTON To: Owner / Architect / Engineer Jack - Morgan Jack Philip Morgan AR00033266 7062 N. Tuxedo Street Indianapolis IN 46220 Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: 14B 4G0412AE 14W1104A 14W09061 14B07037 This project has been reviewed under the 2014 Indiana Building Code. The proposed building, addition, or remodel shall not put the existing building in noncompliance or into further noncompliance in accordance with 675 IAC 12-4-12. Required means of egress shall be maintained during construction and demolition, remodeling or alterations and additions to any building, in accordance with Section 1104, IFC (675 IAC 22-2.5). Portable fire extinguishers shall be installed in accordance with Section 906.1, IFC (675 IAC 22-2.5). Fire walls and vertical fire barriers shall be effectively and permanently identified with signs or stenciling. Such identification shall: 1. Be located in accessible concealed floor, floor-ceiling or attic spaces; 2. Be located within 15 feet of the end of each wall and at intervals not exceeding 30 feet measured horizontally along the wall or partition; and 3. Include lettering not less than 3 inches in height with a minimum 3/8 inch stroke in a contrasting color incorporating the suggested wording, "FIRE WALL or FIRE BARRIER PROTECT ALL OPENINGS" or similar wording in accordance with Section 703.7, IBC (675 IAC 13-2.6). NOTE: Penetrations in Rated Assemblies shall be protected in accordance with Section 714, IBC (675 IAC 13-2.6). NOTE: Occupancy Load Signage shall be posted in accordance with Section 1004.3 IBC (675 IAC 13-2.6). NOTE: A drain pan shall be installed under Water Heaters in accordance with Section 504.7, IPC (675 IAC 16-1.4). NOTE: Flexible air ducts, both metallic and nonmetallic, shall comply with Sections 603.6.1, 603.6.1.1, 603.6.3 and 603.6.4, IMC. Flexible air connectors, both metallic and nonmetallic, shall comply with Sections 603.6.2 through 603.6.4, IMC, in accordance with Section 603.6, IMC (675 Indiana Department of Homeland Security DIVISION OF FIRE & BUILDING SAFETY PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Indianapolis, IN 46204 Fax & e-mail: SUPPORT HOOSIER SAFETY Available At Your Local Licence Branch In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 3178203405, morwalsoplad1@gmail.com ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 2/2 9E11026A 9E11026B 9E30022 AREL IAC 18-1.6). Access and working space shall be provided and maintained about all electric equipment in accordance with Section 110.26, IEC (675 IAC 17-1.8). Required working space about electrical equipment shall not be used for storage in accordance with Section 110.26(B), IEC (675 IAC 17-1.8). If the space above the ceiling is used for environmental air the electrical installation, including communication wiring, cable television wiring and information technology (computer) wiring shall comply with Article 300.22 of the 2009 Indiana Electrical Code, along with the applicable articles listed in Article 800 of the 2009 Indiana Electric Code (675 IAC 17-1.8) Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above - stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will be final, and you must comply with its requirements. Code review official Address (name,title of local official,street,city,state and ZIP code SEAN CALLAHAN JIM BLANCHARD ONE CIVIC SQUARE CARMEL,IN 46032 DEPT OF COMMUNITY SERVICE Fax & e-mail: 3175712499, jblanchard@carmel.in.gov Director, Division of Fire and Building Safety scallahan@dhs.in.gov