HomeMy WebLinkAboutA-102 SECOND FLOOR PLANRELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carmel
n SECOND FLOOR PLAN
SCALE: 1/8" = 1'-0"
NORTH
p Z w o
w 3
00�
OeJ
d
N O U
C m
2�
I�lJJX�Q
Z
Jg iF
K
0000
Im p]pC
f2/IU3
REVISIONS
NO.
Description & Date
NO.
Description & Date
NO.
Description & Date
JOB NO.:
IDB-119-2607
DATE:
1-18-19
DRAWN BY:
RS
CHECKED BY: RS/SV I
•J Na AR1070ppM
STAMM
ARCHITECTURAL
SIGNATURE
GENERAL NOTESAA
oro,..o.. o,.oe.ww
A. WHERE DISSIMILAR FLOOR MATERIALS MEET,
astroao. .oaout wx;wom vidown
THEY SHALL DO SO UNDER THE CENTERLINE OFa'A
THE DOOR, UNLESS NOTED OTHERWISE.
B. ALL DIMENSIONS ON FLOOR PLANS ARE TO
FACE OF METAL STUD WALLS, UNLESS NOTED
OTHERWISE.
C. HINGE SIDE DOOR JAMB AT WALLS WILL
TYPICALLY BE LOCATED 4' MINIMUM FROM
ADJACENT WALL UNLESS NOTED OTHERWISE.
D. SEE REFLECTED CEILING PLANS FOR BULKHEAD
LOCATIONS AND DETAIL REFERENCES.
E. REFER TO FINISH PLANS FOR LOCATION AND
EXTENT OF FINISH FLOOR MATERIALS.
F. PROVIDE WOOD BLOCKING AS REQUIRED. WBHIN
METAL STUD WALLS FOR WALL MOUNTED ITEMS.
U
ARCHITECTURAL
z
PLAN NOTES 0
-
(�
1. INFILL EXISTING DOOR OPENING WITH NEW WALL,
3 5/8' STEEL STUDS AT 160O.C. WITH 5/8" OWE
w
EACH SIDE. REFER TO FINISH SCHEDULE AND OR
PUN FOR FINISH REQUIREMENTS
U Q
2. NEW 3 5/8' STEEL STUDS AT 16'O.C. WITH 5/8'
Z
GINS ONR SIDE. TOP AT 9'-4'. AUGN NEW WALL
> Q
WITH EXISTING. INFlLL EXISTING WALL RECESSES.
0
REFER TO FINISH SCHEDULE AND OR PUN FOR
O
FINISH REQUIREMENTS
N w z
3. NEW 3 5/8' STEEL STUDS AT 16'O.C. WITH 5/8"
c N
GWB EACH SIDE. TOP AT 9'-4". ALIGN NEW WALL
vi
O _
WITH EXISTING. REFER TO FINISH SCHEDULE AND
J
w
OR PUN FOR FINISH REQUIREMENTS
j O 0
4. NEW 3 5/8' STEEL STUDS AT 16"0.C. WITH 5/8'
O U O-
GWB EACH SIDE. TOP AT 9'-4". REFER TO FINISH
v Q
SCHEDULE AND OR PLAN FOR FINISH
Z ZQ
REQUIREMENTS
5. PATCH AND REFINISH END OF WALL WHERE WALL
a Q
WAS DEMOLISHED
6. NEW SINK COUNTER AND MAKE-UP AREA, REFER
z
TO EQUIPMENT PLAN A-701
7. ALIGN AND EXTEND NEW WALL TIGHT TO EXISTING
WINDOW MUWON
B. NEW 3 5/8' STEEL STUDS AT 16'O.C. WITH 5/8'
O
GWB ONE SIDE. TOP AT 9'-4'. REFER TO FINISH
LL.
SCHEDULE AND OR PLAN FOR FINISH
REQUIREMENTS
9. APHONE CALL STATION BACK TO RECEPTION
w
DESK. REFER TO ELECTRICAL DRAWINGS
10. NOT USED
CL
11. EXISTING BULKHEAD ABOVE TO REMAIN, REFER TO
A-901 REFLECTED COUNG PLAN
12. NEW BULKHEAD ABOVE, REFER TO A-901
REFLECTED CEILING PUN
13. EXISTING FLOORING TRANSITIONS TO REMAIN,
REFER TO FINISH FLOORING PLANS
14. FUR OUT WALL WITH 7/8' CHANNELS AND 5/8"
GWB FOR NEW WALL PANEL FINISH SYSTEM. OVER
THE TOP AREA OF EXISTING BUMP OUT ALSO
v
E(n�1
W
OU
i>
G�
:ate
SHEET
Amm 102
SECOND
FLOOR PLAN
DATE: U4/ 12/ 19
PROPRIETARY AND CONFIDENTIAL