HomeMy WebLinkAboutE-203 FIRST FLOOR POWER AND SYSTEMS PLANGENERAL NOTES RELEASED FOR CONSTRUCTION 0 4' 8' 16' NORTH SCALE: 1 /8" = V-0" 1. ALL MATERIAL/EQUIPMENT REMOVED BY SUBCONTRACTORS SHALL BE DISPOSED OF OFF SITE. OWNER HAS FIRST RIGHT OF REFUSAL FOR ANY EQUIPMENT/MATERIAL/PARTS REMOVED FROM PROJECT. 2. FIRE ALARM VISUAL DEVICES SHALL BE SET AT 15 CANDELA WHERE NO VALUE SHOWN. 3. CIRCUIT NUMBERS SHOWN FROM EXISTING PANELS ARE FOR REFERENCE ONLY. USE ACTUAL BREAKERS AVAILABLE AFTER DEMOLITION WORK IS COMPLETE. 4. COLOR OF WIRING DEVICES AND COVERPLATES SHALL MATCH EXISTING. PLAN NOTES 1. PROVIDE POWER CONNECTION TO ELECTRIC DUCT HEATER. PROVDIE 30A DISCONNECT SWITCH. 2. PROVIDE FLUSH JUNCTION BOX FOR FURNITURE FEED CONNECTION TO PARTI110NS. BRANCH CIRCUIT(S) AS INDICATED. 3. PROVIDE FLOOR BOX FOR FURNITURE FEED CONNECTION TO PARTITIONS. BRANCH CIRCUIT(S) AS INDICATED. SAW CUT SLAB AND ROUTE CONDUIT UP IN NEARBY NEW WALL PROVIDE SIMILAR BOX FOR DATA CABLING WITH 1.25" CONDUIT TO ABOVE ACCESSIBLE CEILING. 4. FOR ELEVATOR RECALL 5. CONNECT NEW RECEPTACLES IN THIS ROOM TO BRANCH CIRCUIT LISTED, UNLESS OTHERWISE NOTED. S. EXISTING RECEPTACLES SHALL REMAIN IN THIS ROOM, UNLESS OTHERWISE NOTED. 7. CONNECT TO EXISTING FACE BRANCH CIRCUIT. B. PROVIDE NEW SWITCH FOR CONTROL OF EXISTING BREAK AREA EXHAUST FAN. WIRE INTO EXISTING EF CIRCUIT AS REQUIRED. PROVIDE "EXHAUST FAN" NAMEPLATE ON SWITCH COVERPLATE 9. CONNECT TO EXISTING RECEPTACLE BRANCH CIRCUIT SERVING THIS AREA. 10. INSTALL BEHIND TV MONITOR. COORDINATE MOUNTING WITH TV SUPPORT BRACKET. 11. STUB CONDUIT THROUGH WALL FOR OUTDOOR WAR INSTALL AS HIGH AS POSSIBLE ABOVE FIRST FLOOR CEILING. 12. INSTALL RECEPTACLES ABOVE COUNTER EXCEPT FOR RECEPTACLE SERVING UNDER COUNTER REFRIGERATOR. 13. INSTALL AT CEILING PROJECTOR. 14. INSTALL ABOVE COUNTER BACKSPLASH. 15. SAW CUT FLOOR TO INSTALL CONDUITS FOR POWER AND DATA (1.25")TO RECEPTION DESK. ROUTE FROM ABOVE ACCESSIBLE CEILING DOWN IN WALL, TURN UP INTO FRAMED WALL OF CASEWORK AND TO DEVICE LOCATIONS. 16. REMOVE THREE 1P-20A CIRCUIT BREAKERS SERVING VENDING MACHINES REMOVED DURING THE DEMOLITION PHASE. INSTALL A NEW 3P-100A CIRCUIT BREAKER IN SPACE CREATED. NEW BREAKER SHALL BE SAME MANUFACTURER, TYPE, AND AIC RATING AS EXISTING. USE NEW 100A BREAKER TO FEED NEW PANEL RES. 17. INSTALL ALL GFCI RECEPTACLES SHOWN AT CASEWORK ABOVE COUNTER BACKSPLASH. 18. INSTALL ONE RECEPTACLE AT EACH MICROWAVE SHELF. SEE CASEWORK ELEVATION FOR CONFIGURATION. 19. RELOCATE RECEPTACLE TO NEW WALL FACE. 20. INSTALL 6" BELOW TOP OF COUNTERTOP. 21. RELOCATED MOTORIZED PROJECTION SCREEN FROM CONTROLS AREA. REINSTALL ORIGINAL CONTROL SWITCH IN NEARBY WALL AND CONNECT TO SCREEN. CONNECT SCREEN TO RECEPTACLE CIRCUIT SERVING THE AREA. REVISIONS NO. Description & Dare NO. Description & Dace NO. Description & Dare JOB NO.: IDB-119-2607 DATE: 1-1"9 DRAWN BY: FWH 10100828 STATE OF 0 SIGNATURE Insist drawls( W Lb am4Yb was the =a eaLwm.m. Larrbaa r to rae aw ft wbla r as WtroWby a w118auL rtpta� eyLe4 pamlw Mwl U Z vi LEI U_Q � z a 0 p[ Z LU - c 0 o UCIL 0 0 Z z Q a o z O IL LU 11. G� C� O Cz E co 0) Ov i� aC/-) SHEET Emw203 Subject to compliance with all regulations of State and Local Codes City of Cannel DATE: 04/12/19 FIRST FLOOR POWER AND SYSTEMS PLAN SCALE: 1/8"=l90" PROPRIETARY AND CONFIDENTIAL FIRST FLOOR POWER AND SYSTEMS PLAN