HomeMy WebLinkAboutM-001 MECHANICAL SYMBOLS AND ABBREVIATIONSNOTE: NOT ALL SYMBOLS AND ABBREVIATIONS MAY APPLY TO THIS PROJECT
RELEASE
MECHANICAL ABBREVIATIONS
'F
DEGREES FAHRENHEIT
EOM
END OF AWN DRIP
NPW
NON -POTABLE WATER
AC
ALTERNATING CURRENT OR AIR CONDITIONING
ES
EMERGENCY SHOWER
NTS
NOT TO SCALE
ACCU
AIR COOLED CONDENSING UNIT
ESP
EXTERNAL STATIC PRESSURE (IN. WIG.)
0
OXYGEN
AD
ACCESS DOOR ('M- DWGS.) AREA DRAIN ('P' DWGS.)
ET
EXPANSION TANK
CA
OUTSIDE AIR
ARE
ABOVE FINISHED FLOOR
EW
EMERGENCY EYEWASH
OAT
OUTSIDE AIR INTAKE
AFMS
AIR FLOW MEASURING STATION
EWC
ELECTRIC WATER COOLER
GAT
OUTSIDE AIR TEMPERATURE ('F)
AGA
AMERICAN CAS ASSOCIATION
ENT
ENTERING WATER TEMPERATURE ('F)
080
OPPOSED BLADE DAMPER
AHU
AIR HANDLING UNIT
IX
EXISTING
00
OVERFLOW DRAIN OR OUTSIDE DIAMETER
AI
ANALOG INPUT
EXH
EXHAUST
OFCI
OWNER FURNISHED/CONTRACTOR INSTALLED
AL
ACOUSTICALLY UNED
EXIST
EXISTING
OSD
OPEN SITE DRAIN
AMB
AMBIENT
F&T
FLOAT AND THERMOSTATIC STEAM TRAP
OZ
OUNCE
ANSI
AMERICAN NATIONAL STANDARDS INSTITUTE
FSD
COMBINATION FIRE/SMOKE DAMPER
P
PUMP
AO
ANALOG OUTPUT
FCO
FLOOR CLEANOUT
RED
PARALLEL BLADE DAMPER
AP
ACID PROOF OR ACCESS PANEL
FCU
FAN COIL UNIT
PC
PLUMBING CONTRACTOR
AEG
AIR PRESSURE DROP (IN. WC.)
ED
FIRE DAMPER OR FLOOR DRAIN
RD
PRESSURE DROP (IN. OR Fr. AS NOTED)
ARCH
ARCHITECT(URAL)
FDC
FIRE DEPARTMENT CONNECTION
PE
PNEUMATIC -ELECTRIC
ART
AIR CONDITIONING AND REFRIGERATION INSTITUTE
FDN
FOUNDATION
PH
PHASE (ELECTRICAL)
ARM
AIR RELIEF VALVE
FE
FIRE EXTINGUISHER
PN
POST INDICATOR VALVE
AS
AIR SEPARATOR
FHC
FIRE HOSE CABINET
RPM
PARTS PER MILLION
ASME
AMERICAN SOCIETY OF MECHANICAL ENGINEERS
FLR
FLOOR
FIRM
PRESSURE REDUCING VALVE
ASPE
AMERICAN SOCIETY OF PLUMBING ENGINEERS
FM
FACTORY MUTUAL
PSI
POUNDS PER SQUARE INCH
ASHRAE
AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR
FOV
FUEL OIL VENT
PSIA
PSI ABSOLUTE
CONDITIONING ENGINEERS
FPC
FIRE PROTECTION CONTRACTOR
PSIG
PSI GAUGE
ASTM
AMERICAN SOCIETY FOR TESTING AND MATERIALS
FPM
FEET PER MINUTE
PTAC
PACKAGED TERMINAL AIR CONDITIONING UNIT
ATM
ATMOSPHERE
FPVAV
FAN POWERED VAV UNIT
PVC
POLYVINYL CHLORIDE
AUTO
AUTOMATIC
FS
FLOOR SINK
R
REGISTER
AVG
AVERAGE
FT
FOOT OR FEET
R12
REFRIGERANT (12, 22, ETC.)
AVS
ACID VENT STACK
FIT
FOOTING
RA
RETURN AIR
AW
ACID WASTE
FIR
RNNED TUBE RADIATION
BAD
RADIATION
AWWA
AMERICAN WATER WORKS ASSOCIATION
TURN
FURNACE
RAT
RETURN AIR TEMPERATURE ('F)
BD
BALANCING DAMPER
G
GAS (NATURAL)
RCP
REINFORCED CONCRETE PIPE
BDD
BACKDRAFT DAMPER
GA
GAGE OR GAUGE
RD
ROOF DRAIN
BE
BOTTOM ELEVATION
CAL
GALLON
REV
REVOLUTION
BE
HARRIER FREE
GC
GENERAL CONTRACTOR
RE
RETURN FAN
BFC
BELOW FINISHED CEILING
GIV
GRAVITY INTAKE VENTILATOR
RG
RETURN GRILLE
BHP
BRAKE HORSEPOWER
GPD
GALLONS PER DAY
RH
ROODING HOLE OR RELATIVE HUMIDITY
BLDG
BUILDING
GPH
GALLONS PER HOUR
RM
ROOM
BOD
BOTTOM OF DUCT
GPM
GALLONS PER MINUTE
RP
RADIANT PANEL (CEILING -MOUNTED)
BOP
BOTTOM OF PIPING
GR
GRAINS OR GRILLE
RPM
REVOLUTIONS PER MINUTE
BE
BATHTUB
GRV
GRAVITY RELIEF VENTILATOR
RPS
REVOLUTIONS PER SECOND
ETA
BOTTOM
GT
GREASE TRAP
RTU
ROOFTOP UNIT
BTUH
BTU PER HOUR
HE
HOSE BIBB
RV
RELIEF VALVE OR REUSE VENT
C
CONDENSATE DRAIN
NO
HEAD (FT.)
SA
SUPPLY AIR
CA
COMPRESSED AIR
HG
MERCURY
SAN
SANITARY
CAM
CONSTANT AIR VOLUME
HHWP
HEATING HOT WATER PUMP
SO
SUPPLY DIFFUSER, SMOKE DAMPER, SPUTTER DAMPER
CB
CATCH BASIN
NO
HUB OUTLET
SEER
SEASONAL ENERGY EFFICIENCY RATIO
COW
COUNTERCLOCKWISE
HOBE
HORIZONTAL
SF
SQUARE FOOT, SUPPLY FAN OR SAFETY FACTOR
CD
CARBON DIOXIDE
HP
HORSEPOWER
SG
SUPPLY GRILLE
CF
CEILING FAN
HR
HOUR(S)
SH
SHOWER
CFM
CUBIC FEET PER MINUTE
HRIU
HEATING ONLY ROOFTOP UNIT
SK
SINK
CH
CHILLER
HX
HEAT EXCHANGER
SMACNA
SHEET METAL AND AIR CONDITIONING CONTRACTORS
CHWP
CHILLED WATER PUMP
HE
FREQUENCY
NATIONAL ASSOCIATION
Cl
CAST IRON
IB
INVERTED BUCKET STEW TRAP
SP
STATIC PRESSURE
CLG
COILING
ID
DIAMETER, INSIDE
SPEC
SPECIFICATIONS
CMP
CORRUGATED METAL PIPE
IE
INVERT ELEVATION
SO
SQUARE
CO
CLEAHOUT
IN
INCH/INCHES
SR
SUPPLY REGISTER
COMP
COMPRESSOR
TNT
INTERIOR
SW
SAFETY RELIEF VALVE
COND
CONDENSER
INV
INVERT
SS
STAINLESS STEEL OR SERVICE SINK
CONY
CONVECTOR
IRS
INTERNATIONAL PIPE STANDARD
STD
STANDARD
CP
CONDENSATE PUMP
IW
INDIRECT WASTE
SV
STEAM VENT
CPVC
CHLORINATED POLYVNYL CHLORIDE
K
KELVIN
TCC
TEMPERATURE CONTROL CONTRACTOR
Cr
COOUNG TOWER
KEC
KITCHEN EQUIPMENT CONTRACTOR
TO
TEMPERATURE DIFFERENCE
CU
CONDENSING UNIT
KW
KILOWATT
TE
TOP ELEVATION
CUH
CABINET UNIT HEATER
LAB
LABORATORY
TEMP
TEMPERATURE
CUV
CLASSROOM UNIT VENTILATOR
LAT
LEAVING AIR TEMPERATURE ('F)
TF
TRANSFER FAN
W
CONTROL VALVE
LAV,L
LAVATORY
TAN
THERMOSTATIC MIXING VALVE
W
COEFFICIENT, VALVE FLOW
TB
POUND
TONS
TONS OF REFRIGERATION
CW
CLOCKWISE
LBS
POUNDS
TP
TRAP PRIMER
CWP
CONDENSER WATER PUMP
LD
LINEAR DIFFUSER
TRANS
TRANSITION
dB
DECIBEL
LDR
LINEAR RETURN DIFFUSER
TS
TAMPER SWITCH
BE
DRAIN BOX OR DRY BULB
LP
LIQUID PETROLEUM
TSP
TOTAL STATIC PRESSURE (IN. WC.)
DC
DIRECT CURRENT
LOUT
LEAVING WATER TEMPERATURE ('F)
D V
THERMAL EXPANSION VALVE
BE
DRINKING FOUNTAIN
MA
MIXED AIR
UCO
UNDERCUT DOOR
DO
DOOR GRILLE
MAT
MIXED AIR TEMPERATURE ('F)
UH
UNIT HEATER
DH
DUCT HEATER
MAX
MAXIMUM
UL
UNDERWRITER'S LABORATORIES
DI
DIGITAL INPUT
ME
MOP BASIN
UP
URINAL
CIA
DIAMETER
MEN
1000 BTU PER HOUR
UV
UNIT VENTILATOR
DIFF
DIFFUSER
MC
MECHANICAL CONTRACTOR
V
VOLTS (ELECTRICAL) OR VIM
DN
DOWN
MCA
MINIMUM CIRCUIT AMPACITY
VAC
VACUUM
DO
DIGITAL OUTPUT
MCC
MOTOR CONTROL CENTER
VAV
VARIABLE AIR VOLUME
DS
DOWNSPOUT
MD
MOTORIZED DAMPER
VB
VACUUM BREAKER
DUC
DOOR UNDER CUT
MH
MANHOLE
VD
VOLUME DAMPER
DW
DISTILLED WATER
MIN
MINIMUM
VEL
VELOCITY IN FEET PER MINUTE
DWG
DRAWING
MISC
MISCELLANEOUS
VERT
VERTICAL
DWH
DOMESTIC WATER HEATER
MS
MOP SINK
VF
VENTILATION FAN
DWV
DRAINAGE WASTE, & VENT
MTD
MOUNTED
VFD
VARIABLE FREQUENCY DRIVE
DX
DIRECT EXPANSION (REFRIGERATION)
W
MANUAL VENT
VR
VENT THROUGH ROOF
G
EACH
N
NITROGEN
W
WASTE OR WATT
EAT
ENTERING AIR TEMPERATURE ('F)
N/A
NOT APPUCABLE
W.C.
WATER COLUMN
EC
ELECTRICAL CONTRACTOR
NC
NORMALLY CLOSED OR NOISE CRITERIA
W
WITH
ECO
EXTERIOR CLEANOUT
NEC
NATIONAL ELECTRIC CODE
W 0
WITHOUT
EDR
EQUIVALENT DIRECT RADIATION
NEC
NATIONAL FIRE CODE
WE
WET BULB
EER
ENERGY EFFICIENCY RATIO
HERA
NATIONAL FIRE PROTECTION ASSOCIATION
WC
WATER CLOSET
EF
EXHAUST FAN
NFWH
NON -FREEZE WALL HYDRANT
WCO
WALL CLEANOUT
EFF
EFFICIENCY
NIC
NOT IN CONTRACT
WH
WALL HYDRANT
EG
EXHAUST GRILLE
NO
NORMALLY OPEN OR NITROUS OXIDE
WPC
WATER PRESSURE DROP (FT.HD.)
ELEV
ELEVATION
NOM
NOMINAL
WSHP
WATER SOURCE HEAT PUMP
YD
YARD DRAIN
PIPING DESIGNATIONS
HIGH PRESSURE STEAM
HPS
STORM DRAIN
MEDIUM PRESSURE STEAM
MPS
FOOTING DRAIN TILE
LOW PRESSURE STEAM
LES
WASTE, SANITARY SEWER
HIGH PRESSURE CONDENSATE
- — — — — — — — -HPC— — — — — — — —
WASTE, SANITARY GREASE
MEDIUM PRESSURE CONDENSATE
- — — — — — — — - MPC — — — — — — — —
SANITARY FORCED MAIN
LOW PRESSURE CONDENSATE
- — — — — — — — - LPC — — — — — — — —
VENT
BOILER BLOW DOWN
BBD
ACID WASTE
BOILER FEED
BF
ACID VENT
PUMPED CONDENSATE
PC
INDIRECT DRAIN
VACUUM PUMP DISCHARGE
VPD
PUMP DISCHARGE UNE
HUMIDIFICATION UNE
H
DOMESTIC COLD WATER
MAKEUP WATER
MU
DOMESTIC HOT WATER
ATMOSPHERIC VIM
---------AN--------
DOMESTIC HOT WATER RETURN
HEAT RECLAIM PIPING
HR
140rF HOT WATER
HEATING WATER SUPPLY
HWS
140' HOT WATER RETURN
HEATING WATER RETURN
HWR
CHILLED DRINKING WATER SUPPLY
REFRIGERANT DISCHARGE
RD
CHILLED DRINKING WATER RECIR.
REFRIGERANT SUCTION
HIS
SOFT WATER
REFRIGERANT LIQUID
RL
CHLORINATED WATER
REFRIGERANT HOT GAS
RHG
DISTILLED WATER
BRINE SUPPLY
BS
OBONIZED WATER
BRINE RETURN
BR
LAWN SPRINKLER SUPPLY
CONDENSER WATER SUPPLY
CWS
FIRE PROTECTION UNE
CONDENSER WATER RETURN
CWR
GAS - LOW PRESSURE
CHILLED WATER SUPPLY
CHWS
GAS - MEDIUM PRESSURE
CHILLED WATER RETURN
CHWR
GAS - HIGH PRESSURE
DUAL TIME WATER SUPPLY
DTWS
GAS VENT
DUAL TIME WATER RETURN
DTWR
MEDICAL COMPRESSED AIR
HEAT PUMP WATER SUPPLY
HPS
MEDICAL VACUUM
HEAT PUMP WATER RETURN
HPR
OXYGEN
GLYCOL SUPPLY
GS
NITROGEN
GLYCOL RETURN
GR
NITROUS OXIDE
FUEL OIL SUPPLY
FOS
CARBON DIOXIDE
FUEL OIL RETURN
FOR
WET VACUUM CLEANING
FUEL OIL VENT
FOV
DRY VACUUM CLEANING
CONDENSATE DRAIN LINE
D
FOR CONSTRUCTION
ST
DT
CRSAN
FM
— — — — — — — - V --------
AN
- — — — — — — — -AV — — — — — — — _
D
PD
14PF
SW
CIE
DI
BE
US
F
G
MG
HG
GV--------
MA
ATV
0
N
DVC
PIPING SYMBOLS
�r Ia
RISE IN PIPING
DROP IN PIPING
CAPPED PIPING
PIPE CONTINUED ELSEWHERE AS NOTED
PIPE GUIDES
PIPE ANCHORS
3E X
—
FLEXIBLE PIPE CONNECTOR
PIPE EXPANSION JOINT
Fl
PIPE EXPANSION LOOP
CONCENTRIC REDUCER
N
ECCENTRIC REDUCER
Ids
UNION, FLANGED UNION
"
PITCH (IN DIRECTION OF ARROW)
DIRECTION OF FLOW
GATE VALVE
HIf
BALL VALVE
COIT
GLOBE VALVE
BUTTERFLY VALVES
m
d
PLUG VALVE
T7
CHECK VALVE
.�
PRESSURE REDUCING VALVE
- -
REDUCED PRESSURE BACKFLDW PREVENTOR
- -
DOUBLE CHECK BACKFIAW PREVENTOR
ANGLE VALVE
PRESSURE RELIEF VALVE
VALVE WITH OUTSIDE STEM & YOKE
PNUEMATIC TWO-WAY CONTROL VALVE
PNUEMATIC THREE-WAY CONTROL VALVE
ELECTRIC TWO-WAY CONTROL VALVE
ELECTRIC THREE-WAY CONTROL VALVE
SOLENOID VALVE
Qu
FLOW SNITCH
PRESSURE SWITCH
Qu
AQUASTAT
ORIFICE FLOW METER
C+y7
VENTURI ROW METER
u
MANUAL BALANCE VALVE
AUTOMATIC FLAW CONTROL VALVE
STRAINER
STRAINER WITH CAPPED SLOWDOWN
4
MANUAL AIR VIM
AUTOMATIC AIR VENT
VACUUM BREAKER
m
PETE'S PLUG
THERMOMETER
QV
PRESSURE GAUGE
�T
STEAM TRAP WITH DESIGNATION
REFRIGERATION SIGNT GLASS
AIR FILTER/DRYER
G
REFRIGERATION THERMAL EXPANSION VALVE
PUMP
WATER HAMMER ARRESTOR (DESIGNATION OPTIONAL)
2' FD-1
FLOOR DRAIN W/ SIZE & TYPE
I jQ
END OF PIPE CLEANOUT
-0
FLOOR CLENNIIIT
D
U,
MIXT
WALL CLEANOUT
HO
mu
EXTERIOR CLEPNOUT/RODDING HOLE
UNDERGROUND CONCRETE THRUST BLOCK
--
THERMOSTATIC MIXING VALVE
- O--H
HOSE BIBB
------ iMOH--
WATER METER
Eli
GCS METER
ORD O OD
ROOF BRAIN OR OVERFLOW DRAIN
.i
POST INDICATOR VALVE
>
FIRE DEPARTMENT CONNECTION
VALVE TAMPER SWITCH
C
UPRIGHT SPRINKLER HEAD
U
PENDANT SPRINKLER HEAD
DRi PENCMHT SPRINKLER HEN
.
SIDEWALL SPENKLER HEAD
CONCEALED SPRINKLER HEAD
HVAC SYMBOLS
RISE IN SUPPLY DUCII ORIC
CHANGE IN DUCT PRESSURE CLASSIFICATION
S
J(
✓�
DROP IN SUPPLY DUCTWORK
ELECTRIC DUCT COIL
i
RISE IN RETURN DUCTWORK
C
22���FT���TJ3��
�LLG
D
HYDRONIC DUCT REHEAT COIL
DROP IN RETURN DUCTWORK
SOUND ATTENUATOR
I
A
RISE IN EXHAUST DUCTWORK
CAPPED DUCTWORK
DROP IN EXHAUST DUCTWORK
RECTANGULAR DUCTWORK DESIGNATION
36/18
�-T
71
STANDARD RADIUS ELBOW
NDAR RADIUS 1LBO TIMES WIDTH OF DUCT)
780
ROUND SPIRAL DUCTWORK DESIGNATION
90 DEGREE ELBOW WITH TURNING VANES
OVAL DUCTWORK DESIGNATION
36/180
2
AIRFLOW
STANDARD TRANSITIONS
DUCT CONSTRUCTED OF ALUMINUM
STAINLESS STEEL
AL SS
OFFSET TRANSITION
DIRECTION OF SUPPLY AIR
SQUARE DUCT TO ROUND DUCT TRANSITION
DIRECTION OF RETURN OR EXHAUST AIR
TAP OR SHOE TAP FITTING
PANEL TYPE CEIUNG DIFFUSER
LBOOT
SPIN -IN FITTING W/ BALANCE DAMPER
UNEAR SLAT DIFFUSER
80 LMOUTH FITTING
><
SUPPLY REGISTER
CONICAL FITTING
Q
EXHAUST OR RETURN REGISTER
IS LATERAL FITTING
T
SIDEWALL REGISTER OR GRILLE
OFFSET IN OULTYIORK OLVATION
RISE (R) DROP (D)
/
�
CENTRIFUGAL ROOF EXHAUST FAN
— R
MOTORIZED CONTROL DAMPER
+ lD
UNIT HEATER
BD
BALANCE DAMPER
FINNED TUBE RADIATION
FIRE DAMPER W/ DESIGNATION
��� ///���
A
DOT
CEUNG DESTRATIFIGnON FAN
ACCESS DOORS
THERMOSTAT
LADJ
AD—
blllllllllllllllllllLlllllllll�lllllllll4
FLEXIBLE DUCTWORK, MAXIMUM FIVE FEET
TEMPERATURE SENSOR
�I^ S
FLEXIBLE DUCT CONNECTION
OH
HUMIDISTAT
36/la
INDICATES DUCT IS TO BE INIDtWLLY UNED
SEE SHOWN IS INTERNAL FREE WEA
REQUIREMENT
CG
R e
DOOR GRILLE
REFERENCE INFORMATION
GENERAL NOTES: GENERAL INFORMATION OR REQUIREMENTS
TYPE CORRESPONDING TO SCHEDULE
SHEET DESIGNATIONS
WHICH MAY PERTAIN TO ALL SHEETS OF
THE DISCIPLINE THE NOTE IS LOCATED ON.
MOOD SERIES SHEETS: SYMBOLS AND ABBREVIATIONS SHEET
rot DIFFUSER, GRILLE, OR REGISTERS
PLAN NOTES: KEYED NOTES WHICH ARE SPECIFIC ONLY
M100 SERIES SHEETS: OVERALL FLOOR PLANS AND ROOF PUNS
TO THE SHEET THE NOTE IS LOCATED ON.
SCHEDULED AIRFLOW IN CUBIC FEET PER MINUTE
EXAMPLES: ,J11 � �
EQUIPMENT TYPE
M200 SERIES SHEETS: FLOOR PUNS 0.S NOTED
M300 SERIES SHEETS: ENLARGED FLOOR PLANS, SECTIONS, AND
EQUIPMENT DESIGNATIONS
ELEVATIONS
SECTION REFERENCE: INDICATES LOCATION OF DETAILED ELEVATION OR
SECTION THROUGH AREA INDICATED BY MARKER.
`
M400 SERIES SHEETS: DETAILS SHEETS
\` LETTER CORRESPONDING TO RELATED MR SYSTEM (OPTIONAL)
SECTION NUMBER
SEQUENTIAL NUMBER SPECIFIC TO THE LABELED EQUIPMENT
M500 SERIES SHEETS: SCHEDULES SHEETS
A
M3o1
ELEVATION NOTATION
SHEET SECTION IS LOCATED ON
LINETYPE DESIGNATIONS
12'-0" AFF
DETAIL REFERENCE: INDICATES LOCATION OF DETAIL USED TO
B.O.D.
LIGHT, SOLID UNETYPES INDICATE EQUIPMENT OR
CLARIFY INSTALLATION, SPECIFY COMPONENTS, ETC.
MATERIALS TO REMAIN.
DETAIL NUMBER
INTERMEDIATE OR HEAVY SOUD UNETYPES INDICATE
1
NEW EQUIPMENT OR MATERIALS.
M501 M501
$ INDICATES POINT OF CONNECTION TO EXISTING
EQUIPMENT, PIPING, OR MATERIALS
_ _ _ HEAVY DASHED UNETYPES INDICATE MATERIALS TO
BE REMOVED.
MNOR APPLICABLE
SHEET DETAIL IS LOCATED ON SPECIFICATION SECTION
INDIGOES POINT TO DISCONNECT EXISTING
EQUIPMENT, PIPING, OR MATERIALS
REVISIONS
NO.
Description & Date
NO.
Description & Date
NO.
Description Is Date
JOB NO.:
IDB-119-2607
DATE:
1-18-19
DRAWN BY:
TPT
CHECKED BY: KLB I
10100828
STATE OF
0
SIGNATURE
Ti dmvft mud II o Ix me Wa
APA.oP vetMR a rato.m.no. 9.Mca avd
JI 1» rvpraduwd m eEeN w m
e aormae�.'Y.Meo�m=w etittw
PrtmLYev.
U
Z
LU
U_a
Z
Q
0
p[
0
N
LU
Z
C
O
N
O
w0
U
_
0
0- N
C
Z
Q
Q
Q
0
1:
Z
�/
L..T_
O
LL
�.T_/
L.
LU
SHEET
Subject to compliance with all reguMlions
of State and Local Codes
City ofCamrel `/(�}�
�NrtA�fl\ONy;),jpA�
DATE: 04/12/19
PROPRIETARY AND CONFIDENTIAL
MECHANICAL
SYMBOLS AND
ABBREVIATIONS