Loading...
HomeMy WebLinkAboutA-101 FIRST FLOOR PLANPerformance Services Office Renovation Code Summary Applicable Codes: 2014 Indiana Building Code Indiana General Administrative Rules (GAR) Project Description: The project scope involves renovation of the la floor for occupancy by Performance Services as administrative offices, which curently occupies the 2v" floor of the building. The previous use of the 1" floor area was office use. Applicability of Codes to the Alterations are permitted to an existing building without requiring the Project: entire existing building or portions of the existing building unaffected by the proposed scope of renovation to be brought into compliance with current codes [Rule 4, Section 12, GAR] Occupancy Classifications: Office and administrative use, meeting rooms with an occupant load of less than 50 each - B Occupancy [304.1, 301 Training room and break room with an occupant load of more than 50 -A-3 Occupancy [303.41 Construction Type: Type DB Construction permitted based upon nonseptrated occupancies [508.31 Allowable Area: Tabular Area: 91500 Sf Table 503 Spaimkler Increase: 19,000 sf 506.3 Frontage Increase: + 7 125 sf 506.2 Allowable Area: 35,625 sf Actual Area per Fluor. 18,700 sf Occupancy Separation: Occupancy separations not required based upon nonsepamted occupancies [508.31 SprinWer System: An automatic sprinkler system is provided throughout the building - sprinlders will be relocated as necessary to accommodate the new plan configuration Ir I I I I I I I I I I RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City offCamlel (} �VTG\a.�S1PA.6L 0 I GLASS FLUSH FLUSH n DOOR 1/ELEVATIONS L' SCALE: 4' - 110" .1 e a e a N 0 EQ. EQ. EQ. F6 F7 n DOOR FRAME ELEVATIONS J SCALE: 1/4" = 1'-0" l �l l i i i i i t n FIRST FLOOR PLAN SCALE: 1/8" = 1'-0" NORTH DOOR AND FRAME SCHEDULE DOOR FRAME DOOR NUMBER SIZE MAT. TYPE MAT. TYPE JAMB DEBTH HARDWARE RATING REMARKS FIRST FLOOR A101A 1 A101B 1 A106A 31-01.X8140" AL GLASS AL F1 - - - 2 AlOaA 3'-0" X 8'-0" WD F STL F2 - - - A108B T-0" X 8'-0" WD F STL F2 - - - A111A 3'-0" X 8'-0" WD F STL F2 A114A 3'-0" X 8'-0" WD F STL F2 A115A T-01.X8'-0" AL GLASS AL F3 - - - 2 A115B - AL GLASS AL F4 - - - 2 AlI6A 3'-011X8'-0" AL GLASS AL F3 2 A117A T-01.X8'-0" WD NL STL F2 - - - A11RA 3'-011X8'-0" WD NL STL F2 - - - A124A 3'-0" X 8'-0" WD F STL F2 - - - A125A T-0" X 8'-0" WD F STL F2 - - - A127A 3'-0" X 8'-0" WD F STL F2 - - - Al2RA 3'-011X8140" WD F STL F2 - - - A129A T-0" X 8'-0" WD F STL F2 - - - A137A 3'-0" X 8'-0" WD F STL F2 - - - A138A 3'-0" X 8'-0" WD F STL F2 - - - A139A T-0" X 8'-0" WD F STL F2 - - - A140A 3'-0" X 8'-0" WD F STL F2 - - - A143A 4'-0" X 3'-0" STL FS 3 A142A T-0" X 8'-0" WD F STL F2 A142B 4'-0" X 3'-0" STL FS 3 SECOND FLOOR A202A 31-011X8'-0" AL GLASS AL F6 2 A202B T-01.X8'-0" AL GLASS AL F6 2 A207A - - - AL F7 - - - 2 A209A 3'-0" X 8'-0" WD F STL F2 DOOR AND FRAME REMARKS I EXISTING DOOR AND FRAME TO REMAIN 2 BUTT GLAZED ENTRY SYSTEM 3 BORROWED LIGHT pZwo w3 �owo po oo� oej No00 WU �WUU w d � o �Fii�" Ra Cm i� Jg Z iF NZ_N S� ow�o a p]pC Im 0000 f2/IU3 REVISIONS NO. Descnption & Date NO. Description & Date NO. Descnption & Date JOB NO.: IDB-119-2607 DATE: 1-I8-19 DRAWN BY: RS I CHECKED BY: RSISAV I ARCHITECTURAL p�peTo,� GENERAL NOTES Nowor l A. WHERE DISSIMILAR FLOOR MATERIALS MEET, •1, THEY SHALL DO SO UNDER THE CENTERLINE OF 7• 6TAmcc THE DOOR, UNLESS NOTED OTHERWISE. `*�,4 �4'DUMP q�CHI'fE� B. ALL DIMENSIONS ON FLOOR PLANS ARE TO FACE OF METAL STUD WALLS, UNLESS NOTED OTHERWISE. C. HINGE SIDE DOOR JAMB AT WALLS WILL / TYPICALLY BE LOCATED 4" MINIMUM FROM SIGNATURE ADJACENT WALL UNLESS NOTED OTHERWISE. D. SEE REFLECTED CEILING PUNS FOR BULKHEAD LOCATIONS AND DETAIL REFERENCES. raw enw� m Ne emrmr .s. me �s� r a pert�aee ea.law and E. REFER TO FINISH PUNS FOR LOCATION AND aaaa mt ae reps =" Io wsma er hat EXTENT OF FINISH FLOOR MATERIALS. ye, „ 1 vidtion F. PROVIDE WOOD BLOCKING AS REQUIRED. WITHIN pwm m. METAL STUD WALLS FOR WALL MOUNTED ITEMS. ARCHITECTURAL PLAN NOTES O 1. INRLL EXISTING DOOR OPENING WITH NEW WALL, 3 5/8° STEEL STUDS AT 16"O.C. WITH 5/8" GWB EACH SIDE. REFER TO FINISH SCHEDULE AND OR PUN FOR FINISH REQUIREMENTS 2. NEW 3 5/8' STEEL STUDS AT 161 WITH 5/8" GWB ONR SIDE. TOP AT 9'-4°. ALIGN NEW WALL WITH EXISTING. INRLL EXISTING WALL RECESSES. I REFER TO FINISH SCHEDULE AND OR PLAN FOR U FINISH REQUIREMENTS 3. NEW 3 5/8° STEEL STUDS AT 16°O.C. WITH 5/8° Z GWB EACH SIDE. TOP AT W-4". ALIGN NEW WALL WITH EXISTING. REFER TO FINISH SCHEDULE AND OR PLAN FOR FINISH REQUIREMENTS () 4. NEW 3 5/8" STEEL STUDS AT 16"O.C. WITH 5/8- GWB EACH SIDE. TOP AT 9'-40. REFER TO FINISH SCHEDULE AND OR PLAN FOR FINISH U Q REQUIREMENTS z 5. PATCH AND REFINISH END OF WALL WHERE WALL \\ Q WAS DEMOLISHED / 6. NEW SINK COUNTER AND MAKE-UP AREA, REFER O cl� 0 TO EQUIPMENT PLAN A-701 '� L U z 7. ALIGN AND EXTEND NEW WALL TIGHT TO EXISTING WINDOW MULLION p Ln Uj 8. NEW 3 5/8° STEEL STUDS AT 16"O.C. WITH 5/8' GWB ONE SIDE. TOP AT 9'-4°. REFER TO FINISH > LL] O O SCHEDULE AND OR PUN FOR FINISH O f I a fV REQUIREMENTS C `J Q 9. APHONE CALL STATION BACK TO RECEPTION N z Z DESK. REFER TO ELECTRICAL DRAWINGS Of 1. NOT USED �( 0 11. EXISTING BULKHEAD ABOVE TO REMAIN, REFER TO �l REFLECTED CEILING PUN AEW z 12. NEW BULKHEAD ABOVE, REFER TO A-901 B REFLECTED CEILING PLAN o/ 13. EXISTING FLOORING TRANSITIONS REMAIN, REFER TO FINISH FLOORING PLANS 14. FUR OLR WALL WITH 7/8" CHANNELS AND 5/8° O GWB FOR NEW WALL PANEL FINISH SYSTEM. OVER L"L THE TOP AREA OF EXISTING BUMP OUT ALSO of CL SHEET Amm101 FI RST FLOOR PLAN DATE: U4/ 11/ 19 PROPRIETARY AND CONFIDENTIAL