HomeMy WebLinkAboutS101RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carmel (�
CLARK DEITRICH 35/8', 16 GAGE
RIGID CONNECTION LT. GA. MTL. STUDS
CLIP D975 OR MC683 @ 16" O.C.
W/ 1/2' DIA. HILTI
KWIK BOLT 3 EXPANSION EXIST. CONC. SLAB
ANCHOR ON COMP. MTL. DECK
EXIST. STEEL BEAM
(SEE PLAN)
TYPICAL 3 5/8" LOW WALL CONSTRUCTION DETAIL
SCALE: 3A' = V-0-
0
Z
S545 CLIP
W/ (5) SCREWS
BOX HEADER WITH
WEB STIFFENERS
(SEE SCHEDULE AND
DETAIL"C")
REMOVE FLANGE OF
VERTICAL TRACK AT
INTERSECTION WITH
HORIZONTAL TRACK
S545 CLIP
W/ (5) SCREWS
JAMB STUDS ATTACHED
WITH TRACK
(SEE SCHEDULE FOR
NUMBER OF STUDS
AND DETAIL -B-)
TYPICAL BOXED HEADER CONNECTION
SCALE. NOT TO SCALE
LIGHT GAGE HEADER SCHEDULE
MAXIMUM
MEMBER
TRACK
FULL HEIGHT
HEADER
MARK
OPENING
SIZE
SIZE
STUDS
ATTACHMENT
DETAIL
H1
23'-0'
(2)800S250-54
60OT200-97
(2)600S16243
D
H2
4'-0-
(2) 600S162-03
60OT12543
(2) 60OS16243
A
NOTES:
1. USE THIS SCHEDULE TO SIZE HEADERS DEPICTED ON THE
STRUCTURAL PLANS.
GENERAL NOTES
DESIGN LIVE LOADS
DL-1 FLOOR LIVE LOADS
MEZZANINE .................................. 100 PSF
THE ABOVE NOTED LIVE LOADS HAVE BEEN REDUCED AS PERMITTED BY THE 2014
INDIANA BUILDING CODE AND ASCE 7-10.
DL-2 ROOF LIVE LOADS
BASIC ROOF LIVE LOAD ......................... 30 PSF
DL-3 ROOF SNOW LOADS
GROUND SNOW LOAD .......................... 20 PSF
FLAT ROOF SNOW LOAD ........................ 20 PSF
SNOW EXPOSURE FACTOR ......................... 1.0
SNOW LOAD IMPORTANCE FACTOR .................. 1.0
THERMAL FACTOR ................................. 1.0
ALL SNOW LOADS ARE APPLIED IN ACCORDANCE WITH THE 2014 INDIANA BUILDING
CODE AN D ASCE 7-10.
DL-4 WIND LOADS
ULTIMATE DESIGN WIND SPEED ................. 115 MPH
NORMAL DESIGN WIND SPEED ................... 90 MPH
RISK CATEGORY .................................... 11
EXPOSURE CATEGORY .............................. B
INTERNAL PRESSURE COEFFICIENT ................. 0.18
ALL WIND LOADS ARE APPLIED IN ACCORDANCE WITH THE 2014 INDIANA BUILDING
CODE AND ASCE 7-10.
CAST -IN -PLACE CONCRETE
C-1 ALL REINFORCED CONCRETE WORK SHALL BE PERFORMED IN ACCORDANCE WITH
THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE' (ACI 318-14) OF
THE AMERICAN CONCRETE INSTITUTE.
C-2 MINIMUM Pc REQUIRED AT 28 DAYS:
FOUNDATIONS................................4000 PSI
INTERIOR SLABS..............................4000 PSI
EXTERIOR SLABS..............................5000 PSI
CJ ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (144 PSF+) WITH ALL CEMENT
CONFORMING TO ASTM C150, TYPE I. MAXIMUM AGGREGATE SIZE SHALL BE 1-1/2' FOR
FOOTINGS AND 3/4' FOR WALLS AND SLABS, CONFORMING TO ASTM C33.
C4 REINFORCEMENT
DEFORMED BARS .................ASTM A615, GRADE 60
WELDED WIRE FABRIC ......................ASTM A185
C-5 ALL LEVELING GROUT SHALL BE NON-METALLIC SHRINK -RESISTANT GROUT
COMPLYING WITH CE-CRD-C621, AND SHALL HAVE A MINIMUM To OF 5000 PSI.
C-6 MINIMUM CONCRETE COVER FOR REINFORCING STEEL:
SLABS AND WALLS ................................ 314-
BEAMS......................................... 1-1/2'
CONCRETE EXPOSED TO WEATHER:
#5 BARS AND SMALLER ..................... 1-1/2"
BARS LARGER THAN #5........................ 2-
CONCRETE IN CONTACT WITH EARTH .................3'
ALL WELDED WIRE MESH IS TO BE PLACED 1' FROM TOP OF SLABS.
C-7 CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CONCRETE OPENINGS
AND/OR PENETRATIONS REQUIRED FOR OTHER TRADES PRIOR TO PLACING
CONCRETE.
C-8 CONDUITS OR PIPES EMBEDDED IN SLABS SHALL NOT HAVE AN OUTSIDE DIMENSION
LARGER THAN 113 THE SLAB THICKNESS AND SHALL BE SPACED NO CLOSER THAN 3
DIAMETERS ON CENTER. ALUMINUM CONDUITS SHALL NOT BE EMBEDDED IN
CONCRETE.
A-1 ALL EXPANSION ANCHORS SHALL BE 'HILTI KWIK-BOLT III' (AS MANUFACTURED BY
HILTI FASTENING SYSTEMS, INC.) OR AN APPROVED EQUAL, MEETING THE
REQUIREMENTS OF FEDERAL SPECIFICATION FF-S-325, GROUP II, TYPE 4, CLASS 1.
A-2 ALL ANCHOR SPACING, EMBEDMENT, EDGE DISTANCE, AND INSTALLATION SHALL BE
IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. REFER TO SECTIONS
AND DETAILS ON THE DRAWINGS FOR ADDITIONAL INFORMATION.
LIGHT GAGE STEEL STUDS
LS-1 ALL LIGHT GAGE STEEL FRAMING WORK SHALL MEET THE REQUIREMENTS OF THE
"DESIGN OF COLD FORMED STRUCTURAL STEEL MEMBERS" OF THE AMERICAN IRON
AND STEEL INSTITUTE (AISI), 2012 EDITION.
LS-2 ALL 16 GAGE STEEL STUDS SHALL BE GALVANIZED, AND SHALL BE FORMED FROM
STEEL THAT MEETS THE REQUIREMENTS OF ASTM A 653, GRADE A, WITH A MIN IMUM
YIELD STRENGTH OF 50,000 PSI.
LS-3 PROVIDE STUD BRIDGING IN COMPLIANCE WITH THE RECOMMENDATIONS OF THE
MANUFACTURER, BUT DO NOT EXCEED 5'-0' VERTICAL SPACING BETWEEN ROWS OF
BRIDGING.
LS-4 PROVIDE DOUBLE STUDS ON BOTH SIDES OF ALL WALL OPENINGS EXCEEDING 16' IN
WIDTH.
LS-5 PROVIDE RIGID CONNECTION CLIPS AT BASE OF ALL LOW WALL STUDS. ALL RIGID
CONNECTIONS SHALL BE CLARK DIETRICH ANCHOR CLIPS, OR MOM ENT
CLIPS, OR AN APPROVED EQUAL WITH THE FOLLOWING MIN IMUM PROPERITES:
F1(SHEAR)................................... 11261bs
F2(TENSION)................................. 2278 Ice
MOMENT...................................2743 in-lbs
LS-6 FASTEN RIGID CONNECTIONS TO STUDS WITH A MINIMUM OF(4)#12 SCREWS.
FASTEN TO CONCRETE SLAB WITH (1)112- DIAMETER HILTI KWIK BOLT III IN EACH
CLIP (2114' MINIMUM EMBEDMENT).
MISCELLANEOUS
M-1 VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO FABRICATION OF ANY
STRUCTURAL COMPONENTS. IMMEDIATELY NOTIFY THE ENGINEER AND ARCHITECT
OF ANY DISCREPANCIES FOUND DURING FIELD VERIFICATION.
CLAIR
CLIP 6',16 GAGE
RIGID9 OOE TRCH— Fr—ON
OiCOMC MTL. DECK
W/ ill'ILI}I`\KWIK BOLT 3EXPANSIONEXIST. CONC. SLAB
ANCHOR
BEAM
TYPICAL 6" LOW WALL CONSTRUCTION DETAIL
SCALE: 314' = V-0'
SECTION OF RUNNER TRACK
FOR ATTACHMENT OF HEADER
TO FULL HEIGHT OF STUD
DETAIL "A"
(HEADER ATTACHMENT)
CAP TRACK
WEB STIFFINERS
AT END BEARINGS
LIGHT GAGE STEEL
JOISTS PER SCHEDULE
BASE TRACK
DETAIL "C"
(TYPICAL LIGHT GAGE HEADER)
MATCH
SAGE
(SEE SCHEDULE)
DETAIL "B"
(JAMB STUDS)
BOX HEADER FULL HEIGHT STUDS
(SEE SCHEDULE) (SEE SCHEDULE)
'il'
, I,I,
I I CLARK DIETRICH
, I,I, H436 BOX -HEADER
—,— ,i,l, CONNECTOR W/
(20) #10-16 SCREWS
(12 @ HEADER,
SINGLE JAMB STUD 8@JAMB)
(SEE SCHEDULE)
DETAIL "D"
(HEADER ATTACHMENT)
O.C.
PPORT
ISSUED FOR CONSTRUCTION
ISSUED FOR BID
ISSUED FOR PERMIT
ISSUED FOR REDLINE REVIEW
ISSUED FOR 50 %
KICK OFF MEETING
MEZZANINE/CANOPY FRAMING PLAN
SCALE: 3132" = V-0"
PLAN NOTES:
1. ELEVATION TOP -OF -EXISTING STEEL BEAM/JOIST BEARING = 114'4" UNLESS
NOTED + OR - (FROM ELEVATION 114'-7') ON PLAN.
2. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS. NOTIFY
ARCHITECT/ENGINEER IMMEDIATELY OF ANY DISCREPANCIES.
3. REFER TO DRAWING S301 FOR GENERAL NOTES AND TYPICAL DETAILS.
4. TYPICAL 3 518' LOW WALL CONSTRUCTION: 362S162-54 (3 518', 16 GAGE) LIGHT GAGE
METAL STUDS SPACED AT 16 INCHES ON CENTER. REFER TO ARCHITECTURAL
DRAWINGS FOR SHEATHING REQUIREMENTS.
5. TYPICAL FULL HEIGHT WALL CONSTRUCTION: 600S162-03 (6', 18 GAGE) LIGHT
GAGE METAL STUDS SPACED AT 16 INCHES ON CENTER. REFER TO
ARCHITECTURAL DRAWINGS FOR SHEATHING REQUIREMENTS.
6.'HX' - INDICATES LIGHT GAGE HEADER ABOVE OPENING IN WALL BELOW.
REFER TO LIGHT GAGE HEADER SCHEDULE ON THIS DRAWING.
7. EXISTING DUCT DROP. FRAME LIGHT GAGE WALLAROUND DUCT.
8. TYPICAL 6' LOW WALL CONSTRUCTION: 60OS162-54 IS", 16 GAGE) LIGHT GAGE
METAL STUDS SPACED AT 16 INCHES ON CENTER. REFER TO ARCHITECTURAL
DRAWINGS FOR SHEATHING REQUIREMENTS.
KEY PLAN
SCALE: V = 100'-0' Q)
1
``N �P RITry Oig4
Q�JeG.G\STE,pFo7�c
Na. PEI 1500090j
P`. STATE OF . 4�4:
REV. PCR
DATE REVISIONS BY
NO. NO.
DWG. TITLE MEZZANINE FRAMING PLAN, GENERAL
NOTES. SECTIONS AND DETAILS
PROJECT
GIANT EAGLE MARKET DISTRICT #6550
LOCATION THE BRIDGES DEVELOPMENT
— 11505ILLINOIS STREET
03-27-19 CARMEL, IN 46032
OWNER GIANT EAGLE, INC.
03-27-19
ITSET0'!t
ral Engineers,Inc2]SSwllow Hill Roatl,Builtling 100 sere rvser rw.
Pittsburgh, Pennsylvania 15220
Phone : (4i2) 722-0880
-- Fax: (412) 722-0887 S101 TSE Project No.: 5700 WNeV
3
h
w
z
0
z
DATE: 04/24/19
FINAL APPROVED PLAN --
TFB