HomeMy WebLinkAboutF103 - FP Demo PlanN.I.C.DNUPDNUPDNUPA.1A.2B.2C.2D.2D.3F.2G.2G.3H.2J.2K.2K.3L.2M.2N.2B.1C.1D.1E.1F.1G.1G.7H.1J.1K.1K.5L.1M.1N.112345678910111213141516171819202122232432222222222222333333322222333333333RXRXRXRXRXRXRXRXRXRXRXRXRXRXRXRXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXRXRXEXEXEXRXRXRXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXRXRXRXRXRXRXRXRXRXRXRXRXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXRXRXRXEXEXEXEXEXEXRXRXEXEXEXEXEXEXRXRXRXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEX2222222EXEXEX11111111111#FIRE PROTECTION DEMOLITION KEY NOTES:1.THE INDICATED SCOPE OF WORK LINE IS FOR GUIDANCE ONLY AND REPRESENTSTHE LIMIT OF GENERAL CONSTRUCTION WORK. THIS CONTRACTOR MAY BE REQUIREDTO DO WORK IN AREAS OUTSIDE OF THIS SCOPE LINE WHERE NECESSARY TODEMOLISH, INSTALL NEW SYSTEMS OR EXTEND TO EXISTING SYSTEMS IN ORDER TOPERFORM THE WORK INDICATED ON THESE DRAWINGS. COORDINATE WITH OWNER'SREPRESENTATIVE TO GAIN ACCESS TO ADJOINING SPACES AND TO MINIMIZEDISRUPTION OF SERVICES.2.EXISTING SPRINKLERS TO REMAIN MARKED WITH EX. (TYPICAL)3.EXISTING SPRINKLERS TO BE REMOVED WITH RX. (TYPICAL)FIRE PROTECTION DEMOLITION GENERAL NOTES:1.ENTIRE FLOOR IS SPRINKLERED PER NFPA-13. NOT ALL SPRINKLERS MAY BE INDICATEDON THIS PLAN.2. PROVIDE SPRINKLER COVERAGE PER SPECIFICATION SPRINKLER OCCUPANCYHAZARD CLASSIFICATIONS.3. SHOULD EXISTING SPRINKLER/S MEET THE SPACING REQUIREMENTS OF NFPA-13,THEN EXISTING SPRINKLER/S SHALL REMAIN IN PLACE.4.COORDINATE DRAINING AND FILLING OF SPRINKLER SYSTEM WITH OWNER'SMAINTENANCE AND FIRE ALARM PERSONAL.123456781011121314151617BA91234567810111213141516179DrawnProject ManagerCheckedContract Drawing DateProject NumberQPNMLKJHGFEDCBA18191819QPNMLKJHGFEDCB202120212222TSRTSRRevit Template Versionv16: 2017.10.05This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information itcontains may be copied or used for other than the specific project for which it was prepared without the written consent of BaxterHodell Donnelly Preston, Inc.
CINCINNATI
COLUMBUS
RALEIGH
PITTSBURGH
ATLANTA
LAWRENCE DIGENNARO, ARCHITECT
302 WEST THIRD STREET
SUITE 500
CINCINNATI, OHIO 45202
PHONE 513.271.1634HIG02.21THE HARTFORD GROUP - 3RD FLOOR RENOVATION
501 PENNSYLVANIA PKWY #400
INDIANAPOLIS, IN 46280
No.Issue/Revision/Submission Date
1 ISSUED FOR BID AND PERMIT 12/14/20182016.05.27F103THIRD FLOOR
FIRE PROTECTION DEMOLITION PLAN 1F103THIRD FLOOR FIRE PROTECTION DEMOLITION PLAN1/8" = 1'-0"ZPKJRHDCP