HomeMy WebLinkAboutF203 - FP PlanA.1A.2B.2C.2D.2D.3F.2G.2G.3H.2J.2K.2K.3L.2M.2N.2B.1C.1D.1E.1F.1G.1G.7H.1J.1K.1K.5L.1M.1N.11234567891011121314151617181920212223DNUPDNUPDNUPDNUPDNUPDNUP4444411111111112222222222353535353535354444444444EXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEXEX#FIRE PROTECTION KEY NOTES:1.THE INDICATED SCOPE OF WORK LINE IS FOR GUIDANCE ONLY AND REPRESENTS THELIMIT OF GENERAL CONSTRUCTION WORK. THIS CONTRACTOR MAY BE REQUIRED TODO WORK IN AREAS OUTSIDE OF THIS SCOPE LINE WHERE NECESSARY TO DEMOLISH,INSTALL NEW SYSTEMS OR EXTEND TO EXISTING SYSTEMS IN ORDER TO PERFORMTHE WORK INDICATED ON THESE DRAWINGS. COORDINATE WITH OWNER'SREPRESENTATIVE TO GAIN ACCESS TO ADJOINING SPACES AND TO MINIMIZEDISRUPTION OF SERVICES.2.EXISTING SPRINKLERS TO REMAIN MARKED WITH EX. (TYPICAL)3.FIELD COORDINATE WITH ARCHITECT, HVAC AND LIGHTING LAYOUTS SO SPRINKLERSAND CEILING ELEMENTS DO NOT HAVE LOCATION CONFLICTS.4.NEW WHITE SEMI RECESSED TYPE SPRINKLER IN THE CEILING TO MATCH EXISTINGBUILDING STANDARD. PROVIDE CONNECTION TO EXISTING SPRINKLER SYSTEM PIPING.(TYPICAL)5.CONTRACTOR SHALL PROVIDE THREADED BRANCH ARM-OVERS FROM NEW SPRINKLERLOCATION TO EXISTING BRANCHES AND CROSS MAINS. (TYPICAL) PROVIDE BOLT-ONBRANCH TEE OR USE EXISTING TEE AT REMOVED SPRINKLER.6.PROVIDE PAINTING OF EXISTING SPRINKLER PIPING. REFER TO ARCHITECTURALDRAWINGS FOR COLOR. (TYPICAL)FIRE PROTECTION GENERAL NOTES:1.ENTIRE FLOOR IS SPRINKLERED PER NFPA-13. NOT ALL SPRINKLERS MAY BE INDICATEDON THIS PLAN.2.PROVIDE SPRINKLER COVERAGE PER SPECIFICATION SPRINKLER OCCUPANCY HAZARDCLASSIFICATIONS .3.SHOULD EXISTING SPRINKLER/S MEET THE SPACING REQUIREMENTS OF NFPA-13, THENEXISTING SPRINKLER/S SHALL REMAIN IN PLACE.4.4. COORDINATE DRAINING AND FILLING OF SPRINKLER SYSTEM WITH OWNER'SMAINTENANCE AND FIRE ALARM PERSONAL.123456781011121314151617BA91234567810111213141516179DrawnProject ManagerCheckedContract Drawing DateProject NumberQPNMLKJHGFEDCBA18191819QPNMLKJHGFEDCB202120212222TSRTSRRevit Template Versionv16: 2017.10.05This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information itcontains may be copied or used for other than the specific project for which it was prepared without the written consent of BaxterHodell Donnelly Preston, Inc.
CINCINNATI
COLUMBUS
RALEIGH
PITTSBURGH
ATLANTA
LAWRENCE DIGENNARO, ARCHITECT
302 WEST THIRD STREET
SUITE 500
CINCINNATI, OHIO 45202
PHONE 513.271.1634HIG02.21THE HARTFORD GROUP - 3RD FLOOR RENOVATION
501 PENNSYLVANIA PKWY #400
INDIANAPOLIS, IN 46280
No.Issue/Revision/Submission Date
1 ISSUED FOR BID AND PERMIT 12/14/20182016.05.27ZPKJRHDCPF203THIRD FLOOR
FIRE PROTECTION PLAN 1F203THIRD FLOOR FIRE PROTECTION PLAN1/8" = 1'-0"