HomeMy WebLinkAboutG001 Cover SheetAC ACOUSTICAL CEILING TILE ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR ALT ALTERNATE APPROX.APPROXIMATELY AVG.AVERAGE BLDG BUILDING CAB CABINET CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED CJ CONTROL JOINT CL CENTERLINE CLG CEILING CM CONSTRUCTION MANAGER CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONT CONTINUOUS CORR CORRIDOR NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED DIA DIAMETER DIM DIMENSION DWG DRAWING EA EACH FE FINISH END FEC FIRE EXTINGUISHER CABINET FIN FINISH FIXT FIXTURE FLR FLOOR FT FOOT (FEET) GA GAUGE GB GRAB BAR GC GENERAL CONTRACTOR G GLAZING GYP GYPSUM HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HT HEIGHT EJ EXPANSION JOINT ELEC ELECTRICAL EMER EMERGENCY EQ EQUAL EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EX'G EXISTING TO REMAIN EXT EXTERIOR FP FILLER PANEL FA FIRE ALARM OPP OPPOSITE LGMF LIGHT GUAGE METAL FRAME PLAM PLASTIC LAMINATE PT PAINT R RADIUS REF REFERENCE HVAC HEATING/VENTILATION/AIR CONDITIONING IN INCH INSUL INSULATION INT INTERIOR JAN JANITOR JT JOINT LB POUND LIN LINEAR MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MTL METAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MTD MOUNTED NOM NOMINAL OFOI OWNER FURNISHED OWNER INSTALLED OPNG OPENING REFR REFRIGERATOR REQ'D REQUIRED REV REVISION RB RUBBER BASE RM ROOM RO ROUGH OPENING SD SOAP DISPENSER SIM SIMILAR SPEC SPECIFICATIONS SF SQUARE FOOT OR FEET SQYD SQUARE YARD STD STANDARD STL STEEL STO STORAGE SS STAINLESS STEEL TB TOWEL BAR TEL TELEPHONE TEMP TEMPORARY TLT TOILET TPD TOILET PAPER DISPENSER TR TRASH RECEPTACLE TV TELEVISION TYP TYPICAL UL UNDERWRITERS LABORATORIES VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE V.I.F.VERIFY IN FIELD WD WOOD WT WEIGHT PROJECT NAME: PROJECT TYPE: GOVERNING BUILDING CODE: USE GROUP (OBC 304.1): CONSTRUCTION TYPE (OBC 602.2): FIRE SUPPRESSION: FIRE ALARM: (YES/NO) FIRE RESISTANCE HOURLY RATING REQUIREMENTS: STRUCTURAL FRAME - INTERIOR BEARING WALLS - INTERIOR NON-BEARING WALLS - FLOOR CONSTRUCTION - ROOF CONSTRUCTION - EXTERIOR WALLS - < 5 FT > 5 FT AND < 10 FT >10 FT AND < 30 FT >30 FT SHAFT ENCLOSURES < 4 STORIES SHAFT ENCLOSURES > 4 STORIES EXIT PASSAGEWAYS CORRIDORS INCIDENTAL USE AREAS STORAGE ROOM > 100 SF BUILDING STATISTICS: BUILDING AREA: NO CHANGES TO EXISTING BUILDING HEIGHT: NO CHANGES TO EXISTING OCCUPANT LOAD CALCULATIONS: LEVEL 3 B - BUSINESS TOTAL CALCULATED OCCUPANT LOAD = EGRESS CALCULATIONS: EXISTING TO REMAIN - NO CHANGES TO EXISTING REFER TO SHEET G002 FOR MORE INFORMATION. PLUMBING FIXTURES: EXISTING TO REMAIN - NO CHANGES TO EXISTING 3RD FLOOR RENOVATION INTERIOR RENOVATION 2014 INDIANA BUILDING CODE B - BUSINESS IIB FULLY SPRINKLERED YES <0> <0> <0> <0> <0> <1> <1> <0> <0> <1> <2> <1> <0> SMOKE PARTITION GSF/PERSON 100 CODE REFERENCE: IBC 304.1 IBC 602.2 IBC TABLE 601 IBC TABLE 601 IBC TABLE 601 IBC TABLE 601 IBC TABLE 601 IBC TABLE 602 IBC TABLE 602 IBC TABLE 602 IBC TABLE 602 IBC 707.4 IBC 707.4 IBC 1021.3 IBC TABLE 1017.1 IBC TABLE 1004.1 SQUARE FEET 34,416 SF OCCUPANTS 345 345 FACE BRICK MASONRY CONCRETE, CAST STONE NEW WALLS (PLAN VIEW), EXISTING CONSTRUCTION (SECTION VIEW) GYPSUM, GROUT, SAND (SECTION VIEW), NEW CONCRETE SLAB (PLAN VIEW) RIGID INSULATION PERIMETER INSULATION CUT STEEL FINISH WOOD WOOD BLOCKING (NOM.) PLYWOOD WOOD BLOCKING (NOT NOM.) METAL DECK BATT INSULATION EARTH GRAVEL, DRAINAGE FILL 0.00' NEW COLUMN REFERENCE INTERIOR PARTITION TYPE EXISTING COLUMN REFERENCE SECTION REFERENCE ELEVATION REFERENCE ROOM TAG REFERENCE KEYNOTE FURNITURE TAG DOOR & DOOR NUMBERA101A ROOM NAME 101 ? RT: RL: A-1 ROOF TAG EXISTING CONSTRUCTION TO BE REMOVED NEW CONSTRUCTION EXISTING CONSTRUCTION TO REMAIN ROOM FINISH TAG WINDOW TAG DRAWING NOTE NEW SPOT ELEVATION REVISION AND NUMBER PLAN VIEW: NEW / EXISTING WINDOW TO REMAIN 1 M999 SIM DETAIL REFERENCE 1'-0"CEILING HEIGHT TAG A.F.F. TOILET ROOM ACCESSORY TAG 1 FLOOR ELEVATION WS* 1i SYSTEM FURNITURE TAG 1i: ... Wall Floor Ceiling Base 1i 1 M999 SIM INDICATES DRAWING SHEET ON WHICH ELEVATION IS SHOWN EXTERIOR ELEVATION REFERENCE ELEVATION REFERENCE INDICATES DRAWING SHEET ON WHICH ELEVATION IS SHOWN ELEVATION REFERENCE INDICATES DRAWING SHEET ON WHICH ELEVATION IS SHOWN 00 0000 0 0.00' 0 ROOF LEVEL ROOF TYPE 0 0 WALLS IN PLAN VIEW 1 A101 NORTH ARROW GENERAL PROJECT NOTES A. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE 2014 INDIANA BUILDING CODE AND ALL OTHER APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. B. TESTING AND INSPECTION SERVICES FOR THE PROJECT SHALL BE PERFORMED BY AN APPROVED TESTING AND INSPECTION AGENCY AS ACCEPTABLE TO THE AUTHORITIES HAVING JURISDICTION. C. INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED IN ACCORDANCE WITH ASTM E84. FINISHES SHALL BE CLASS B (FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450), FINISHES OTHER THAN TEXTILES SHALL BE TESTED IN ACCORDANCE WITH NFPA 286. THESE REQUIREMENTS MEET OR EXCEED THOSE LISTED IN THE BUILDING CODE REFERENCED ABOVE. D. CONTRACTORS SHALL SCHEDULE AND ARRANGE FOR ALL REQUIRED LEGAL INSPECTIONS. E. THE CONTRACTOR'S ATTENTION IS DIRECTED TO THE POSSIBILITY OF ASBESTOS CONTAINING MATERIALS IN THE PROJECT AREA. IN ADDITION, THE CONTRACTOR SHALL CHECK FOR THE PRESENCE OF LEAD ON PAINTED SURFACES WHENEVER WORK IS DONE WHICH COULD CREATE A POSSIBLE SOURCE OF LEAD EXPOSURE. IF ANY SUCH MATERIALS ARE ENCOUNTERED, THE OWNER SHALL BE NOTIFIED AND THE WORK SHALL CEASE UNTIL SUCH TIME THAT THE OWNER HAS REMOVED THE ASBESTOS OR HAS IMPLEMENTED APPROPRIATE LEAD- RELATED MEASURES. FURTHERMORE, THE CONTRACTOR SHALL NOT INTRODUCE ANYTHING CONTAINING ASBESTOS OR LEAD TO THE SITE. CONTRACTOR SHALL NOT USE ANY ASBESTOS OR LEAD CONTAINING PRODUCTS. F. CONTRACTORS SHALL COMPLY WITH ALL CURRENT "HAZARDOUS MATERIALS COMMUNICATIONS" (HAZCOM) REQUIREMENTS. THE CONTRACTOR SHALL OBTAIN "MATERIAL SAFETY DATA SHEETS" (MSDS) FOR ALL HAZARDOUS MATERIALS TO BE USED ON THE PROJECT. OBTAIN DATA SHEETS FROM THE MANUFACTURERS AND DELIVER TO THE OWNER'S REPRESENTATIVE PRIOR TO USING SUCH SUBSTANCES ON SITE. THE CONTRACTOR SHALL ALSO COMPLY WITH LAWS, ORDINANCES, RULES, AND REGULATIONS OF FEDERAL, STATE, REGIONAL, AND LOCAL AUTHORITIES REGARDING HANDLING, STORING, TRANSPORTING, AND DISPOSING OF HAZARDOUS MATERIALS. PRIOR TO TRANSPORTING ANY HAZARDOUS WASTES, THE APPROPRIATE SITE ENVIRONMENTAL LEADER MUST BE CONTACTED. G. CONTRACTORS SHALL NOTE THAT THE OWNER WILL OCCUPY ADJACENT AREAS FOR PERFORMANCE OF NORMAL BUSINESS ACTIVITIES DURINGCONSTRUCTION. CONTRACTORS SHALL TAKE ALL PRECAUTIONS NECESSARY TO PROTECT ADJACENT SPACES, EQUIPMENT, SERVICES, ETC., FROM DAMAGE DURING THE WORK. COORDINATE DEMOLITION AND CONSTRUCTION WORK TO ALLOW ADJACENT AREAS TO REMAIN OPERATIONAL AND SECURED. MAKE PROVISIONS TO PREVENT MIGRATION OF DEMOLITION OR CONSTRUCTION CONTAMINANTS INTO THE OCCUPIED AREAS. EMERGENCY EXIT PATHS SHALL BE MAINTAINED AT ALL TIMES. H. PENETRATIONS THROUGH STRUCTURAL MEMBERS, ROOF ASSEMBLY AND FLOOR SLABS, NOT INDICATED ON THE DRAWINGS, SHALL REQUIRE APPROVAL BY THE ARCHITECT AND OWNER PRIOR TO PERFORMING THE WORK. SEAL CONDUITS, PIPES, AND SYSTEMS WHICH PENETRATE FIRE-RATED WALLS AND PARTITIONS WITH CLASSIFIED SYSTEMS BY UNDERWRITERS LABORATORIES, INC. I. EXACT SIZE AND LOCATIONS OF ALL MECHANICAL AND ELECTRICAL ROOF AND FLOOR OPENINGS SHOWN ON THE ARCHITECTURAL AND STRUCTURAL PLANS ARE TO BE VERIFIED WITH THE MECHANICAL AND ELECTRICAL CONTRACTORS PRIOR TO CONSTRUCTION. J. THE CONTRACTOR SHALL EXAMINE THE SITE AND PORTIONS THEREOF WHICH AFFECT THE WORK AND SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS. NO ADDITIONAL EXPENSE SHALL BE ALLOWED WHICH RESULTS FROM THE FAILURE TO PERFORM THIS EXAMINATION. K. CONTRACTORS SHALL COORDINATE THE SIZE AND LOCATION OF ALL NEW M.E.P. ITEMS OR OPENINGS WITH THE APPROPRIATE CONTRACTORS. L. CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH EXISTING M.E.P. ITEMS AND COORDINATE THE DISCONNECTING, CAPPING, PLUGGING, ETC. WITH BOTH OWNER'S REPRESENTATIVE AND M.E.P. CONTRACTORS PRIOR TO STARTING DEMOLITION WORK. MAINTAIN CONTINUITY OF ALL SERVICES, CIRCUITS AND EQUIPMENT NOT SCHEDULED FOR DEMOLITION OR REWORK. MAINTAIN ALL FIRE PROTECTION SERVICES DURING SELECTIVE DEMOLITION OPERATIONS. PROVIDE TEMPORARY LIGHTING FIXTURES AS REQUIRED FOR THE SAFETY, SECURITY AND PERFORMANCE OF WORK BY ALL TRADES. M. ALL CONCRETE HOUSEKEEPING PADS AND CURBS BY MECHANICAL AND ELECTRICAL CONTRACTORS. REFER MECHANICAL AND ELECTRICAL DRAWINGS. N. EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN, DEMOLISHED MATERIALS SHALL BECOME CONTRACTOR'S PROPERTY AND SHALL BE IMMEDIATELY REMOVED FROM THE PROJECT SITE AND PROPERLY DEPOSED OF. STORE AND/OR DISPOSE OF MATERIAL AS INSTRUCTED BY THE OWNER'S REPRESENTATIVE. O. ALL MATERIALS, FIXTURES AND EQUIPMENT INDICATED IN THE CONSTRUCTION DOCUMENTS SHALL BE NEW, AND AS SPECIFIED, UNLESS IDENTIFIED OTHERWISE. P. NOTIFY THE OWNER PRIOR TO PROCEEDING WITH ANY WORK THAT WOULD BE AFFECTED BY UTILITIES NOTED TO BE REMOVED. Q. FIELD WELDING SHALL ONLY BE DONE BY QUALIFIED WELDERS WHO HAVE BEEN CERTIFIED BY THE OWNER. R. DIMENSIONS INDICATED ON PLANS ARE TO FACE OF PARTITIONS OR COLUMN CENTERLINE UNLESS NOTED OTHERWISE. S. EXISTING COLUMN LINE DIMENSIONS ARE TAKEN FROM THE EXISTING BUILDING PLANS AND SHALL BE VERIFIED BY THE CONTRACTOR IN THE FIELD. T. DO NOT SCALE FROM THE DRAWINGS. THE ARCHITECT SHALL BE NOTIFIED OF ANY CONFLICTS IN DIMENSIONING. U. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL BE 4" FROM THE FACE OF FINISHED WALL TO FACE OF DOOR FRAME JAMB AT HINGE SIDE OR CENTERED BETWEEN PERPENDICULAR PARTITIONS. V. PLUMBING FIXTURES: SINKS, DRINKING FOUNTAINS, WATER CLOSETS AND URINALS ARE TO BE CENTERED WITH CABINETS, BETWEEN PARTITIONS AND FRAMED OPENINGS. W. ALL NEW / EXIST. FINISHED AND PATCHED SURFACES SHALL BE SMOOTH, CONTINUOUSLY FREE OF IMPERFECTIONS AND IN PROPER CONDITION TO RECEIVE THE SPECIFIED FINISH. PATCHED AREAS SHALL MATCH THE ADJACENT MATERIALS CONSTRUCTION AND FINISH. X. NEW CONSTRUCTION ABUTTING EXISTING CONSTRUCTION IN THE SAME PLANE SHALL BE FLUSH UNLESS NOTED OTHERWISE. Y. PATCH AND REPAIR AREAS WITHIN THE SCOPE OF THE PROJECT AND ADJACENT TO THE PROJECT LIMITS WHICH HAVE BEEN AFFECTED BY WORK. Z. TAPE AND FILL ALL JOINTS IN GYPSUM WALLBOARD PANELS, READY FOR PAINTING. PAINTING ABOVE CEILINGS IS NOT REQUIRED. AA. PROVIDE ALL REQUIRED BLOCKING, FURRING AND BACKING FOR ANY WALL MOUNTED FIXTURES, SHELVING AND ACCESSORIES. AB. PROVIDE BACKER ROD AND SEALANT AT ALL DISSIMILAR MATERIALS. AC. ALL WOOD BLOCKING, NAILERS, GROUNDS, PLYWOOD TO BE NON-COMBUSTIBLE. AD. PROVIDE WOOD TREATMENT FOR ALL WOOD ITEMS WHICH WILL BE A PERMANENT PART OF THE BUILDING CONSTRUCTION. TREAT WOOD ITEMS AS APPROPRIATE FOR THE LOCATION AND SEVERITY OF THE CONDITIONS IN WHICH THEY ARE INSTALLED. PROVIDE TREATMENTS WITH APPROPRIATE FIRE-RETARDANT AND EXPOSURE CLASSIFICATIONS. AE. ALL FLOORS ON EITHER SIDE OF DOORWAY OR OPENING SHALL BE LEVEL AND HAVE A MAXIMUM ELEVATION DIFFERENCE OR THRESHOLD HEIGHT OF 1/2". AF. ALL EXISTING CONCRETE FLOORS SCHEDULED TO HAVE NEW FLOORING SHALL BE LEVEL TO WITHIN 1/8" OVER 10'-0" AND MEET ALL FLOORING MANUFACTURER'S REQUIREMENTS FOR PATCHING, LEVELING AND INSTALLATION BEFORE FINISH FLOORING IS APPLIED. AG. WHERE NEW WALL CONSTRUCTION, WALL REPAIR OR INFILL WORK REQUIRES THE WALL TO BE REPAINTED, PAINT ENTIRE WALL FROM CORNER TO CORNER. AH. CONTRACTOR TO REFER TO OTHER DRAWINGS FOR ADDITIONAL GENERAL NOTES FOR OTHER DISCIPLINES. CONTROL JOINT3 5/8" METAL STUD FRAMING 5/8" GYPSUM WALL BOARD FIRE SAFING INSULATION GYP. WALL BOARD 1/4" JOINT, 1/2" MAX BETWEEN PARTITION SYMBOL KEY PARTITION HEIGHT: C = TO CEILING A = ABOVE CEILING S = TO STRUCTURE P = PARTIAL HEIGHT FIRE RATING: 1, 2, OR 3 HOUR ANCILLARY DESIGNATION: S = SOUND INSULATION OO:O0O PARTITION TYPE (REFER TO FLOOR PLANS) CEILING LINE FLOOR LINE UNDERSID E OF DECK *** NOT ALL WALL TYPES ARE USED - REFERENCE FLOOR PLANS FOR WALL LOCATIONS *** GYPSUM PARTITION AND VENEER PLASTER PARTITIONS 6"2 1/2"7/8" F1:C--- F1:A--- F1:S--- F3:C--- F3:A--- F3:S--- F5:-C--- F5:A--- F5:S---4" TYPICAL ( 1 HR. RATED - U.L. DESIGN U465 ) GYPSUM PARTITION = ONE LAYER OF 5/8" GWB, BOTH SIDES VENEER PLASTER PARTITION = ONE LAYER OF 5/8" VPB BOTH SIDES 1 1/2"3 1/8"6 5/8" ONE LAYER OF 5/8" GWB, ONE SIDE 3 5/8" G3:C--- G3:A--- G3:S--- 4 7/8" 6" G4:C--- G4:A--- G4:S--- 7 1/4" FURRED GYPSUM PARTITIONS STC = 39 (43)STC = 39 (43) TEMPORARY PARTITIONS SEALANT 1/2" MIN. NON-COM PLYWOOD. 6" SET METAL STUD RUNNER IN, SEALANT, TYPICAL 3 1/2" SOUND ATTENUATION BLANKETS TYPICAL (1) 5/8" GWB 7 1/8" OF STRUCTURE AS REQUIRED. PARTITION EXTENDS TO UNDERSIDE WITHIN EXISTING PARTITIONS NEW WALL CONSTRUCTION MATCH EXISTING WIDTH, CONSTRUCTION, AND FIRE RATING. X1:A-- X1:S-- X1:C-- INFILLED PARTITIONS DEFLECTION TRACK 5/8" GYPSUM WALL BOARD SAFING INSULATION1"FIRE RATED SEALANT, 1/2" OVERLAP, BOTH SIDES *UL: HW-D-0042 GENERAL PARTITION NOTES A. SUBSTITUTE 5/8" GLASS MAT WATER RESISTANT GYPSUM BACKING BOARD IN LIEU OF GYPSUM BOARD AT ALL GYPSUM BOARD TOILET ROOM PARTITION TYPES SCHEDULED TO RECEIVE CERAMIC WALL TILE. REFER TO FINISH DRAWINGS FOR LOCATION. B. REFER TO REFLECTED CEILING PLANS FOR CEILING HEIGHTS, SOFFIT HEIGHTS, MATERIALS AND LOCATIONS. C. PROVIDE METAL TRIM AT THE EDGES OF ALL GYPSUM BOARD WHERE IT ABUTS ANOTHER MATERIAL. D. DIVIDE ALL GYPSUM WALL BOARD AREAS WITH CONTROL JOINTS NOT EXCEEDING 30'-0" IN EITHER DIRECTION OR AS SHOWN OTHERWISE ON DRAWINGS. PROVIDE RATED CONTROL JOINTS IN FIRE-RATED PARTITIONS. E. APPROPRIATE RATED FIRE DAMPERS ARE REQUIRED IN DUCTS WHICH PENETRATE RATED PARTITIONS. DUCTS, PIPES AND CONDUIT MUST BE SEALED AT PERIMETERS WHERE PENETRATIONS THRU RATED PARTITIONS OCCUR. 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 B A 9 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 179 Drawn Project Manager Checked Contract Drawing Date Project Number Q P N M L K J H G F E D C B A 18 19 18 19 Q P N M L K J H G F E D C B 20 21 20 21 22 22 T S R T S RRevit Template Version v16: 2018.04.02This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information it contains may be copied or used for other than the specific project for which it was prepared without the written consent of Baxter Hodell Donnelly Preston, Inc.150 FAYETTEVILLE STSUITE 820RALEIGH, NC 27601PHONE 919.683.1084RALEIGHCOLUMBUSCINCINNATI274 MARCONI BLVDSUITE 200COLUMBUS, OH 43215PHONE 614.486.1960302 WEST THIRD STREETSUITE 500CINCINNATI, OH 45202PHONE 513.271.1634www.bhdp.com6425 LIVING PLSUITE 200PITTSBURGH, PA 15206PHONE 412.450.6031PITTSBURGH715 PEACHTREE STSUITE 100ATLANTA, GA 30308PHONE 470.426.3762ATLANTAC:\Users\ncarter\Documents\HIG0220 - Hartford Indy_ncarter.rvt 12/14/2018 3:32:27 PM SG / NC MC DS 2016.05.27 HIG02.21 G001COVER SHEETTHE HARTFORD GROUP - 3RD FLOOR RENOVATIONALLEN & SHARIFF ENGINEERING, LLC501 PENNSYLVANIA PKWY - 3RD FLOOR INDIANAPOLIS, IN 46280 ARCHITECTS / INTERIOR DESIGNERS 302 WEST THIRD STREET, SUITE 500 CINCINNATI, OHIO 45202 MEP ENGINEERS 3RD FLOOR RENOVATION BHDP ARCHITECTURE 700 RIVER AVE, SUITE 600 PITTSBURGH, PN 15212 ALLEN & SHARIFF ENGINEERING, LLC 274 MARCONI BLVD. SUITE 200 COLUMBUS, OH 43215 150 FAYETTEVILLE ST, SUITE 820 RALEIGH, NORTH CAROLINA 27601 DRAWING INDEX SHEET NUMBER SHEET NAME GENERAL G001 COVER SHEET G002 LIFE SAFETY PLAN DEMOLITION D103 THIRD FLOOR - DEMOLITION PLAN D403 LEVEL THREE - DEMOLITION REFLECTED CEILING PLAN ARCHITECTURAL A103 THIRD FLOOR - NEW WORK PLAN A403 THIRD FLOOR REFLECTED CEILING PLAN A701 DOOR SCHEDULE AND DETAILS A803 THIRD FLOOR - FINISH PLAN A903 THIRD FLOOR - NEW WORK FURNITURE PLAN FIRE PROTECTION F001 FIRE PROTECTION DATA SHEET F002 FIRE PROTECTION SPECIFICATIONS F103 THIRD FLOOR FIRE PROTECTION DEMOLITION PLAN F203 THIRD FLOOR FIRE PROTECTION PLAN PLUMBING P001 PLUMBING DATA SHEET P002 PLUMBING SPECIFICATIONS P103 THIRD FLOOR PLUMBING DEMOITION PLAN P203 THIRD FLOOR PLUMBING PLAN MECHANICAL M001 MECHANICAL DATA SHEET M002 MECHANICAL SPECIFICATIONS M003 MECHANICAL SPECIFICATIONS M103 THIRD FLOOR MECHANICAL DEMOLITION PLAN M203 THIRD FLOOR MECHANICAL PLAN ELECTRICAL E001 ELECTRICAL DATA SHEET E002 ELECTRICAL SPECIFICATIONS E003 ELECTRICAL SPECIFICATIONS E103 THIRD FLOOR ELECTRICAL DEMOLITION PLAN E203 THIRD FLOOR LIGHTING PLAN E303 THIRD FLOOR POWER PLAN E403 THID FLOOR FIRE ALARM PLAN E501 ELECTRICAL DETAILS E601 ELECTRICAL RISER DIAGRAMS E701 ELECTRICAL SCHEDULES ABBREVIATIONS VICINITY MAP BUILDING CODE ANALYSISSYMBOLS MATERIAL SYMBOL 1 1/2" = 1'-0"G001 2 1-HR RATED CONTROL JOINT 1 1/2" = 1'-0"G001 1 FIRE-RATED GYPSUM PARTITION HEAD @ STRUCTURE No.Issue/Revision/SubmissionDate1 ISSUED FOR BID AND PERMIT12/14/201812/17/2018