HomeMy WebLinkAboutG001 Cover SheetAC ACOUSTICAL CEILING TILE
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
APPROX.APPROXIMATELY
AVG.AVERAGE
BLDG BUILDING
CAB CABINET
CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CM CONSTRUCTION MANAGER
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
DIA DIAMETER
DIM DIMENSION
DWG DRAWING
EA EACH
FE FINISH END
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FT FOOT (FEET)
GA GAUGE
GB GRAB BAR
GC GENERAL CONTRACTOR
G GLAZING
GYP GYPSUM
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
EJ EXPANSION JOINT
ELEC ELECTRICAL
EMER EMERGENCY
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EX'G EXISTING TO REMAIN
EXT EXTERIOR
FP FILLER PANEL
FA FIRE ALARM
OPP OPPOSITE
LGMF LIGHT GUAGE METAL FRAME
PLAM PLASTIC LAMINATE
PT PAINT
R RADIUS
REF REFERENCE
HVAC HEATING/VENTILATION/AIR CONDITIONING
IN INCH
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JT JOINT
LB POUND
LIN LINEAR
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MTL METAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MTD MOUNTED
NOM NOMINAL
OFOI OWNER FURNISHED OWNER INSTALLED
OPNG OPENING
REFR REFRIGERATOR
REQ'D REQUIRED
REV REVISION
RB RUBBER BASE
RM ROOM
RO ROUGH OPENING
SD SOAP DISPENSER
SIM SIMILAR
SPEC SPECIFICATIONS
SF SQUARE FOOT OR FEET
SQYD SQUARE YARD
STD STANDARD
STL STEEL
STO STORAGE
SS STAINLESS STEEL
TB TOWEL BAR
TEL TELEPHONE
TEMP TEMPORARY
TLT TOILET
TPD TOILET PAPER DISPENSER
TR TRASH RECEPTACLE
TV TELEVISION
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
V.I.F.VERIFY IN FIELD
WD WOOD
WT WEIGHT
PROJECT NAME:
PROJECT TYPE:
GOVERNING BUILDING CODE:
USE GROUP (OBC 304.1):
CONSTRUCTION TYPE (OBC 602.2):
FIRE SUPPRESSION:
FIRE ALARM: (YES/NO)
FIRE RESISTANCE HOURLY RATING REQUIREMENTS:
STRUCTURAL FRAME -
INTERIOR BEARING WALLS -
INTERIOR NON-BEARING WALLS -
FLOOR CONSTRUCTION -
ROOF CONSTRUCTION -
EXTERIOR WALLS -
< 5 FT
> 5 FT AND < 10 FT
>10 FT AND < 30 FT
>30 FT
SHAFT ENCLOSURES < 4 STORIES
SHAFT ENCLOSURES > 4 STORIES
EXIT PASSAGEWAYS
CORRIDORS
INCIDENTAL USE AREAS
STORAGE ROOM > 100 SF
BUILDING STATISTICS:
BUILDING AREA: NO CHANGES TO EXISTING
BUILDING HEIGHT: NO CHANGES TO EXISTING
OCCUPANT LOAD CALCULATIONS:
LEVEL 3 B - BUSINESS
TOTAL CALCULATED OCCUPANT LOAD =
EGRESS CALCULATIONS: EXISTING TO REMAIN - NO CHANGES TO EXISTING
REFER TO SHEET G002 FOR MORE INFORMATION.
PLUMBING FIXTURES: EXISTING TO REMAIN - NO CHANGES TO EXISTING
3RD FLOOR RENOVATION
INTERIOR RENOVATION
2014 INDIANA BUILDING CODE
B - BUSINESS
IIB
FULLY SPRINKLERED
YES
<0>
<0>
<0>
<0>
<0>
<1>
<1>
<0>
<0>
<1>
<2>
<1>
<0>
SMOKE PARTITION
GSF/PERSON
100
CODE REFERENCE:
IBC 304.1
IBC 602.2
IBC TABLE 601
IBC TABLE 601
IBC TABLE 601
IBC TABLE 601
IBC TABLE 601
IBC TABLE 602
IBC TABLE 602
IBC TABLE 602
IBC TABLE 602
IBC 707.4
IBC 707.4
IBC 1021.3
IBC TABLE 1017.1
IBC TABLE 1004.1
SQUARE FEET
34,416 SF
OCCUPANTS
345
345
FACE BRICK
MASONRY
CONCRETE, CAST STONE
NEW WALLS (PLAN VIEW),
EXISTING CONSTRUCTION (SECTION VIEW)
GYPSUM, GROUT, SAND (SECTION VIEW),
NEW CONCRETE SLAB (PLAN VIEW)
RIGID INSULATION
PERIMETER INSULATION
CUT STEEL
FINISH WOOD
WOOD BLOCKING (NOM.)
PLYWOOD
WOOD BLOCKING (NOT NOM.)
METAL DECK
BATT INSULATION
EARTH
GRAVEL, DRAINAGE FILL
0.00'
NEW COLUMN
REFERENCE
INTERIOR PARTITION TYPE
EXISTING COLUMN
REFERENCE
SECTION REFERENCE
ELEVATION REFERENCE ROOM TAG
REFERENCE KEYNOTE
FURNITURE TAG
DOOR & DOOR NUMBERA101A
ROOM NAME
101
?
RT:
RL:
A-1
ROOF TAG
EXISTING CONSTRUCTION TO
BE REMOVED
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO
REMAIN
ROOM FINISH TAG
WINDOW TAG
DRAWING NOTE
NEW SPOT ELEVATION
REVISION AND NUMBER
PLAN VIEW: NEW / EXISTING
WINDOW TO REMAIN
1
M999
SIM
DETAIL REFERENCE
1'-0"CEILING HEIGHT TAG A.F.F.
TOILET ROOM ACCESSORY TAG
1
FLOOR ELEVATION
WS*
1i
SYSTEM FURNITURE TAG
1i: ...
Wall
Floor
Ceiling
Base
1i
1
M999
SIM
INDICATES DRAWING SHEET ON
WHICH ELEVATION IS SHOWN
EXTERIOR ELEVATION REFERENCE
ELEVATION REFERENCE
INDICATES DRAWING SHEET ON
WHICH ELEVATION IS SHOWN
ELEVATION REFERENCE
INDICATES DRAWING SHEET ON
WHICH ELEVATION IS SHOWN
00 0000 0
0.00'
0
ROOF LEVEL
ROOF TYPE
0
0
WALLS IN PLAN VIEW
1
A101
NORTH ARROW
GENERAL PROJECT NOTES
A. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE 2014 INDIANA BUILDING
CODE AND ALL OTHER APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES.
B. TESTING AND INSPECTION SERVICES FOR THE PROJECT SHALL BE PERFORMED BY AN APPROVED
TESTING AND INSPECTION AGENCY AS ACCEPTABLE TO THE AUTHORITIES HAVING JURISDICTION.
C. INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED IN ACCORDANCE WITH ASTM E84.
FINISHES SHALL BE CLASS B (FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450), FINISHES OTHER
THAN TEXTILES SHALL BE TESTED IN ACCORDANCE WITH NFPA 286. THESE REQUIREMENTS MEET OR
EXCEED THOSE LISTED IN THE BUILDING CODE REFERENCED ABOVE.
D. CONTRACTORS SHALL SCHEDULE AND ARRANGE FOR ALL REQUIRED LEGAL INSPECTIONS.
E. THE CONTRACTOR'S ATTENTION IS DIRECTED TO THE POSSIBILITY OF ASBESTOS CONTAINING
MATERIALS IN THE PROJECT AREA. IN ADDITION, THE CONTRACTOR SHALL CHECK FOR THE
PRESENCE OF LEAD ON PAINTED SURFACES WHENEVER WORK IS DONE WHICH COULD CREATE A
POSSIBLE SOURCE OF LEAD EXPOSURE. IF ANY SUCH MATERIALS ARE ENCOUNTERED, THE OWNER
SHALL BE NOTIFIED AND THE WORK SHALL CEASE UNTIL SUCH TIME THAT THE OWNER HAS REMOVED
THE ASBESTOS OR HAS IMPLEMENTED APPROPRIATE LEAD- RELATED MEASURES. FURTHERMORE,
THE CONTRACTOR SHALL NOT INTRODUCE ANYTHING CONTAINING ASBESTOS OR LEAD TO THE SITE.
CONTRACTOR SHALL NOT USE ANY ASBESTOS OR LEAD CONTAINING PRODUCTS.
F. CONTRACTORS SHALL COMPLY WITH ALL CURRENT "HAZARDOUS MATERIALS COMMUNICATIONS"
(HAZCOM) REQUIREMENTS. THE CONTRACTOR SHALL OBTAIN "MATERIAL SAFETY DATA SHEETS"
(MSDS) FOR ALL HAZARDOUS MATERIALS TO BE USED ON THE PROJECT. OBTAIN DATA SHEETS FROM
THE MANUFACTURERS AND DELIVER TO THE OWNER'S REPRESENTATIVE PRIOR TO USING SUCH
SUBSTANCES ON SITE. THE CONTRACTOR SHALL ALSO COMPLY WITH LAWS, ORDINANCES, RULES,
AND REGULATIONS OF FEDERAL, STATE, REGIONAL, AND LOCAL AUTHORITIES REGARDING
HANDLING, STORING, TRANSPORTING, AND DISPOSING OF HAZARDOUS MATERIALS. PRIOR TO
TRANSPORTING ANY HAZARDOUS WASTES, THE APPROPRIATE SITE ENVIRONMENTAL LEADER MUST
BE CONTACTED.
G. CONTRACTORS SHALL NOTE THAT THE OWNER WILL OCCUPY ADJACENT AREAS FOR PERFORMANCE
OF NORMAL BUSINESS ACTIVITIES DURINGCONSTRUCTION. CONTRACTORS SHALL TAKE ALL
PRECAUTIONS NECESSARY TO PROTECT ADJACENT SPACES, EQUIPMENT, SERVICES, ETC., FROM
DAMAGE DURING THE WORK. COORDINATE DEMOLITION AND CONSTRUCTION WORK TO ALLOW
ADJACENT AREAS TO REMAIN OPERATIONAL AND SECURED. MAKE PROVISIONS TO PREVENT
MIGRATION OF DEMOLITION OR CONSTRUCTION CONTAMINANTS INTO THE OCCUPIED AREAS.
EMERGENCY EXIT PATHS SHALL BE MAINTAINED AT ALL TIMES.
H. PENETRATIONS THROUGH STRUCTURAL MEMBERS, ROOF ASSEMBLY AND FLOOR SLABS, NOT
INDICATED ON THE DRAWINGS, SHALL REQUIRE APPROVAL BY THE ARCHITECT AND OWNER PRIOR
TO PERFORMING THE WORK. SEAL CONDUITS, PIPES, AND SYSTEMS WHICH PENETRATE FIRE-RATED
WALLS AND PARTITIONS WITH CLASSIFIED SYSTEMS BY UNDERWRITERS LABORATORIES, INC.
I. EXACT SIZE AND LOCATIONS OF ALL MECHANICAL AND ELECTRICAL ROOF AND FLOOR OPENINGS
SHOWN ON THE ARCHITECTURAL AND STRUCTURAL PLANS ARE TO BE VERIFIED WITH THE
MECHANICAL AND ELECTRICAL CONTRACTORS PRIOR TO CONSTRUCTION.
J. THE CONTRACTOR SHALL EXAMINE THE SITE AND PORTIONS THEREOF WHICH AFFECT THE WORK
AND SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS. NO ADDITIONAL EXPENSE SHALL BE
ALLOWED WHICH RESULTS FROM THE FAILURE TO PERFORM THIS EXAMINATION.
K. CONTRACTORS SHALL COORDINATE THE SIZE AND LOCATION OF ALL NEW M.E.P. ITEMS OR
OPENINGS WITH THE APPROPRIATE CONTRACTORS.
L. CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH EXISTING M.E.P. ITEMS AND COORDINATE THE
DISCONNECTING, CAPPING, PLUGGING, ETC. WITH BOTH OWNER'S REPRESENTATIVE AND M.E.P.
CONTRACTORS PRIOR TO STARTING DEMOLITION WORK. MAINTAIN CONTINUITY OF ALL SERVICES,
CIRCUITS AND EQUIPMENT NOT SCHEDULED FOR DEMOLITION OR REWORK. MAINTAIN ALL FIRE
PROTECTION SERVICES DURING SELECTIVE DEMOLITION OPERATIONS. PROVIDE TEMPORARY
LIGHTING FIXTURES AS REQUIRED FOR THE SAFETY, SECURITY AND PERFORMANCE OF WORK BY ALL
TRADES.
M. ALL CONCRETE HOUSEKEEPING PADS AND CURBS BY MECHANICAL AND ELECTRICAL CONTRACTORS.
REFER MECHANICAL AND ELECTRICAL DRAWINGS.
N. EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, REINSTALLED, OR OTHERWISE
INDICATED TO REMAIN, DEMOLISHED MATERIALS SHALL BECOME CONTRACTOR'S PROPERTY AND
SHALL BE IMMEDIATELY REMOVED FROM THE PROJECT SITE AND PROPERLY DEPOSED OF. STORE
AND/OR DISPOSE OF MATERIAL AS INSTRUCTED BY THE OWNER'S REPRESENTATIVE.
O. ALL MATERIALS, FIXTURES AND EQUIPMENT INDICATED IN THE CONSTRUCTION DOCUMENTS SHALL
BE NEW, AND AS SPECIFIED, UNLESS IDENTIFIED OTHERWISE.
P. NOTIFY THE OWNER PRIOR TO PROCEEDING WITH ANY WORK THAT WOULD BE AFFECTED BY
UTILITIES NOTED TO BE REMOVED.
Q. FIELD WELDING SHALL ONLY BE DONE BY QUALIFIED WELDERS WHO HAVE BEEN CERTIFIED BY THE
OWNER.
R. DIMENSIONS INDICATED ON PLANS ARE TO FACE OF PARTITIONS OR COLUMN CENTERLINE UNLESS
NOTED OTHERWISE.
S. EXISTING COLUMN LINE DIMENSIONS ARE TAKEN FROM THE EXISTING BUILDING PLANS AND SHALL BE
VERIFIED BY THE CONTRACTOR IN THE FIELD.
T. DO NOT SCALE FROM THE DRAWINGS. THE ARCHITECT SHALL BE NOTIFIED OF ANY CONFLICTS IN
DIMENSIONING.
U. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL BE 4" FROM THE FACE OF FINISHED WALL TO
FACE OF DOOR FRAME JAMB AT HINGE SIDE OR CENTERED BETWEEN PERPENDICULAR PARTITIONS.
V. PLUMBING FIXTURES: SINKS, DRINKING FOUNTAINS, WATER CLOSETS AND URINALS ARE TO BE
CENTERED WITH CABINETS, BETWEEN PARTITIONS AND FRAMED OPENINGS.
W. ALL NEW / EXIST. FINISHED AND PATCHED SURFACES SHALL BE SMOOTH, CONTINUOUSLY FREE OF
IMPERFECTIONS AND IN PROPER CONDITION TO RECEIVE THE SPECIFIED FINISH. PATCHED AREAS
SHALL MATCH THE ADJACENT MATERIALS CONSTRUCTION AND FINISH.
X. NEW CONSTRUCTION ABUTTING EXISTING CONSTRUCTION IN THE SAME PLANE SHALL BE FLUSH
UNLESS NOTED OTHERWISE.
Y. PATCH AND REPAIR AREAS WITHIN THE SCOPE OF THE PROJECT AND ADJACENT TO THE PROJECT
LIMITS WHICH HAVE BEEN AFFECTED BY WORK.
Z. TAPE AND FILL ALL JOINTS IN GYPSUM WALLBOARD PANELS, READY FOR PAINTING. PAINTING ABOVE
CEILINGS IS NOT REQUIRED.
AA. PROVIDE ALL REQUIRED BLOCKING, FURRING AND BACKING FOR ANY WALL MOUNTED FIXTURES,
SHELVING AND ACCESSORIES.
AB. PROVIDE BACKER ROD AND SEALANT AT ALL DISSIMILAR MATERIALS.
AC. ALL WOOD BLOCKING, NAILERS, GROUNDS, PLYWOOD TO BE NON-COMBUSTIBLE.
AD. PROVIDE WOOD TREATMENT FOR ALL WOOD ITEMS WHICH WILL BE A PERMANENT PART OF THE
BUILDING CONSTRUCTION. TREAT WOOD ITEMS AS APPROPRIATE FOR THE LOCATION AND SEVERITY
OF THE CONDITIONS IN WHICH THEY ARE INSTALLED. PROVIDE TREATMENTS WITH APPROPRIATE
FIRE-RETARDANT AND EXPOSURE CLASSIFICATIONS.
AE. ALL FLOORS ON EITHER SIDE OF DOORWAY OR OPENING SHALL BE LEVEL AND HAVE A MAXIMUM
ELEVATION DIFFERENCE OR THRESHOLD HEIGHT OF 1/2".
AF. ALL EXISTING CONCRETE FLOORS SCHEDULED TO HAVE NEW FLOORING SHALL BE LEVEL TO WITHIN
1/8" OVER 10'-0" AND MEET ALL FLOORING MANUFACTURER'S REQUIREMENTS FOR PATCHING,
LEVELING AND INSTALLATION BEFORE FINISH FLOORING IS APPLIED.
AG. WHERE NEW WALL CONSTRUCTION, WALL REPAIR OR INFILL WORK REQUIRES THE WALL TO BE
REPAINTED, PAINT ENTIRE WALL FROM CORNER TO CORNER.
AH. CONTRACTOR TO REFER TO OTHER DRAWINGS FOR ADDITIONAL GENERAL NOTES FOR OTHER
DISCIPLINES.
CONTROL JOINT3 5/8" METAL STUD
FRAMING
5/8" GYPSUM
WALL BOARD
FIRE SAFING
INSULATION GYP. WALL BOARD
1/4" JOINT, 1/2" MAX BETWEEN
PARTITION SYMBOL KEY
PARTITION HEIGHT:
C = TO CEILING
A = ABOVE CEILING
S = TO STRUCTURE
P = PARTIAL HEIGHT
FIRE RATING: 1, 2, OR 3 HOUR
ANCILLARY DESIGNATION:
S = SOUND INSULATION
OO:O0O
PARTITION TYPE
(REFER TO FLOOR PLANS)
CEILING LINE
FLOOR LINE
UNDERSID
E OF
DECK
*** NOT ALL WALL TYPES ARE USED - REFERENCE FLOOR PLANS FOR WALL LOCATIONS ***
GYPSUM PARTITION AND
VENEER PLASTER PARTITIONS
6"2 1/2"7/8"
F1:C---
F1:A---
F1:S---
F3:C---
F3:A---
F3:S---
F5:-C---
F5:A---
F5:S---4" TYPICAL ( 1 HR. RATED - U.L. DESIGN U465 )
GYPSUM PARTITION = ONE LAYER OF 5/8" GWB, BOTH SIDES
VENEER PLASTER PARTITION = ONE LAYER OF 5/8" VPB BOTH SIDES
1 1/2"3 1/8"6 5/8"
ONE LAYER OF 5/8" GWB, ONE SIDE
3 5/8"
G3:C---
G3:A---
G3:S---
4 7/8"
6"
G4:C---
G4:A---
G4:S---
7 1/4"
FURRED GYPSUM PARTITIONS
STC = 39 (43)STC = 39 (43)
TEMPORARY
PARTITIONS
SEALANT
1/2" MIN. NON-COM
PLYWOOD.
6"
SET METAL STUD
RUNNER IN,
SEALANT, TYPICAL
3 1/2" SOUND
ATTENUATION
BLANKETS TYPICAL
(1) 5/8" GWB
7 1/8"
OF STRUCTURE AS REQUIRED.
PARTITION EXTENDS TO UNDERSIDE
WITHIN EXISTING PARTITIONS
NEW WALL CONSTRUCTION
MATCH EXISTING
WIDTH,
CONSTRUCTION, AND
FIRE RATING.
X1:A--
X1:S--
X1:C--
INFILLED
PARTITIONS
DEFLECTION TRACK
5/8" GYPSUM
WALL BOARD SAFING INSULATION1"FIRE RATED SEALANT, 1/2"
OVERLAP, BOTH SIDES
*UL: HW-D-0042
GENERAL PARTITION NOTES
A. SUBSTITUTE 5/8" GLASS MAT WATER RESISTANT GYPSUM BACKING BOARD IN LIEU
OF GYPSUM BOARD AT ALL GYPSUM BOARD TOILET ROOM PARTITION TYPES
SCHEDULED TO RECEIVE CERAMIC WALL TILE. REFER TO FINISH DRAWINGS FOR
LOCATION.
B. REFER TO REFLECTED CEILING PLANS FOR CEILING HEIGHTS, SOFFIT
HEIGHTS, MATERIALS AND LOCATIONS.
C. PROVIDE METAL TRIM AT THE EDGES OF ALL GYPSUM BOARD WHERE IT ABUTS
ANOTHER MATERIAL.
D. DIVIDE ALL GYPSUM WALL BOARD AREAS WITH CONTROL JOINTS NOT EXCEEDING
30'-0" IN EITHER DIRECTION OR AS SHOWN OTHERWISE ON DRAWINGS. PROVIDE
RATED CONTROL JOINTS IN FIRE-RATED PARTITIONS.
E. APPROPRIATE RATED FIRE DAMPERS ARE REQUIRED IN DUCTS WHICH
PENETRATE RATED PARTITIONS. DUCTS, PIPES AND CONDUIT MUST BE SEALED AT
PERIMETERS WHERE PENETRATIONS THRU RATED PARTITIONS OCCUR.
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17
B
A
9
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 179
Drawn
Project Manager
Checked
Contract Drawing Date
Project Number
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
18 19
18 19
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
20 21
20 21
22
22
T
S
R
T
S
RRevit Template Version v16: 2018.04.02This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information it contains may be copied or used for other than the specific project for which it was prepared without the written consent of Baxter Hodell Donnelly Preston, Inc.150 FAYETTEVILLE STSUITE 820RALEIGH, NC 27601PHONE 919.683.1084RALEIGHCOLUMBUSCINCINNATI274 MARCONI BLVDSUITE 200COLUMBUS, OH 43215PHONE 614.486.1960302 WEST THIRD STREETSUITE 500CINCINNATI, OH 45202PHONE 513.271.1634www.bhdp.com6425 LIVING PLSUITE 200PITTSBURGH, PA 15206PHONE 412.450.6031PITTSBURGH715 PEACHTREE STSUITE 100ATLANTA, GA 30308PHONE 470.426.3762ATLANTAC:\Users\ncarter\Documents\HIG0220 - Hartford Indy_ncarter.rvt 12/14/2018 3:32:27 PM
SG / NC
MC
DS
2016.05.27
HIG02.21
G001COVER SHEETTHE HARTFORD GROUP - 3RD FLOOR RENOVATIONALLEN & SHARIFF ENGINEERING, LLC501 PENNSYLVANIA PKWY - 3RD FLOOR
INDIANAPOLIS, IN 46280
ARCHITECTS / INTERIOR DESIGNERS
302 WEST THIRD STREET, SUITE 500
CINCINNATI, OHIO 45202
MEP ENGINEERS
3RD FLOOR RENOVATION
BHDP ARCHITECTURE
700 RIVER AVE, SUITE 600
PITTSBURGH, PN 15212
ALLEN & SHARIFF ENGINEERING, LLC
274 MARCONI BLVD. SUITE 200
COLUMBUS, OH 43215
150 FAYETTEVILLE ST, SUITE 820
RALEIGH, NORTH CAROLINA 27601
DRAWING INDEX
SHEET NUMBER SHEET NAME
GENERAL
G001 COVER SHEET
G002 LIFE SAFETY PLAN
DEMOLITION
D103 THIRD FLOOR - DEMOLITION PLAN
D403 LEVEL THREE - DEMOLITION REFLECTED CEILING PLAN
ARCHITECTURAL
A103 THIRD FLOOR - NEW WORK PLAN
A403 THIRD FLOOR REFLECTED CEILING PLAN
A701 DOOR SCHEDULE AND DETAILS
A803 THIRD FLOOR - FINISH PLAN
A903 THIRD FLOOR - NEW WORK FURNITURE PLAN
FIRE PROTECTION
F001 FIRE PROTECTION DATA SHEET
F002 FIRE PROTECTION SPECIFICATIONS
F103 THIRD FLOOR FIRE PROTECTION DEMOLITION PLAN
F203 THIRD FLOOR FIRE PROTECTION PLAN
PLUMBING
P001 PLUMBING DATA SHEET
P002 PLUMBING SPECIFICATIONS
P103 THIRD FLOOR PLUMBING DEMOITION PLAN
P203 THIRD FLOOR PLUMBING PLAN
MECHANICAL
M001 MECHANICAL DATA SHEET
M002 MECHANICAL SPECIFICATIONS
M003 MECHANICAL SPECIFICATIONS
M103 THIRD FLOOR MECHANICAL DEMOLITION PLAN
M203 THIRD FLOOR MECHANICAL PLAN
ELECTRICAL
E001 ELECTRICAL DATA SHEET
E002 ELECTRICAL SPECIFICATIONS
E003 ELECTRICAL SPECIFICATIONS
E103 THIRD FLOOR ELECTRICAL DEMOLITION PLAN
E203 THIRD FLOOR LIGHTING PLAN
E303 THIRD FLOOR POWER PLAN
E403 THID FLOOR FIRE ALARM PLAN
E501 ELECTRICAL DETAILS
E601 ELECTRICAL RISER DIAGRAMS
E701 ELECTRICAL SCHEDULES
ABBREVIATIONS VICINITY MAP
BUILDING CODE ANALYSISSYMBOLS
MATERIAL SYMBOL
1 1/2" = 1'-0"G001
2 1-HR RATED CONTROL JOINT
1 1/2" = 1'-0"G001
1
FIRE-RATED GYPSUM
PARTITION HEAD @
STRUCTURE No.Issue/Revision/SubmissionDate1 ISSUED FOR BID AND PERMIT12/14/201812/17/2018