HomeMy WebLinkAboutM001 - Mechanical Data Sheet123456781011121314151617BA91234567810111213141516179DrawnProject ManagerCheckedContract Drawing DateProject NumberQPNMLKJHGFEDCBA18191819QPNMLKJHGFEDCB202120212222TSRTSRRevit Template Versionv16: 2017.10.05This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information itcontains may be copied or used for other than the specific project for which it was prepared without the written consent of BaxterHodell Donnelly Preston, Inc.
CINCINNATI
COLUMBUS
RALEIGH
PITTSBURGH
ATLANTA
LAWRENCE DIGENNARO, ARCHITECT
302 WEST THIRD STREET
SUITE 500
CINCINNATI, OHIO 45202
PHONE 513.271.1634HIG02.21THE HARTFORD GROUP - 3RD FLOOR RENOVATION
501 PENNSYLVANIA PKWY #400
INDIANAPOLIS, IN 46280
No.Issue/Revision/Submission Date
1 ISSUED FOR BID AND PERMIT 12/14/20182016.05.27M001MECHANICAL DATA SHEETAABJRHDCP ENTERING WATER TEMPERATURELEAVING WATER TEMPERATUREENTERING AIR TEMPERATURETRANSFER GRILLETOP REGISTERFEET WATER GAUGE (HYDRONIC)FT. W.G.TGTRTOTAL STATIC PRESSURET.S.P.E.W.T.L.W.T.E.A.T.EXTERNAL STATIC PRESSUREREMOVE EXISTING ITEM & RELOCATE TO NEW LOCATIONUNLESS NOTED OTHERWISEDB/WBDRY BULB / WET BULB1000-WATT (1 KW = 3,412 BTUH)INCHES WATER GAUGE (AIR)E.S.P.IN. W.G.KWUNOR / RHEATING, VENTILATION AND AIR CONDITIONING1000 - BRITISH THERMAL UNITSPHASESENS.SENSIBLEHVACMBHEXISTING(E)Ø OR PHNOTES:1. NOT ALL SYMBOLS AND ABBREVIATIONS ARE IN USE FOR THIS PROJECT.DIAMETERØHEATING WATER RETURN PIPINGHEATING WATER SUPPLY PIPINGCONDENSER WATER RETURN PIPINGCONDENSER WATER SUPPLY PIPINGCHILLED WATER RETURN PIPINGCHILLED WATER SUPPLY PIPINGCONDENSATE DRAIN PIPINGREFRIGERANT PIPINGFUEL OIL SUPPLY PIPINGFUEL OIL RETURN PIPINGBALL VALVEGATE VALVECHECK VALVE2-WAY CONTROL VALVE3-WAY CONTROL VALVESTRAINER (W/ BALL VALVE AND CAP)BACKFLOW PREVENTERCIRCUIT SETTER (BALANCING VALVE)GLOBE VALVEELBOW TURNED UPELBOW TURNED DOWNUNIONNATURAL GAS PIPING BUTTERFLY VALVEPLUG VALVEPRESSURE REGULATING VALVEPRESSURE RELIEF VALVEPIPE ANCHORPIPE GUIDEFLEXIBLE CONNECTORAUTOMATIC AIR VENTBOTTOM PIPE CONNECTIONDDUCT SMOKE DETECTORTHERMOSTATVOLUME CONTROL DAMPERCOMBINATION VERTICAL FIRE & SMOKE DAMPERMOTORIZED DAMPERVERTICAL FIRE DAMPER (WALL)BACKDRAFT DAMPERCONNECTION POINT, NEW TO EXISTINGDISCONNECTION POINT WITH CAPDRAWING KEYNOTEEXISTING EQUIPMENT OR DUCTWORK TO BE REMOVEDEXISTING EQUIPMENT OR DUCTWORK TO REMAINNEW EQUIPMENT OR DUCTWORKSYMBOLMECHANICAL DUCTWORK & GENERAL SYMBOLS LEGENDDESCRIPTIONABRV.EQUIPMENT UNIT DESIGNATIONDIFFUSER, REGISTER & GRILLE UNIT DESIGNATION W/ CFMHORIZONTAL FIRE DAMPER (FLOOR)COMBINATION HORIZONTAL FIRE & SMOKE DAMPERVERTICAL SMOKE DAMPER (WALL)HORIZONTAL SMOKE DAMPER (FLOOR)LINED DUCTWORKSUPPLY DUCT UPSUPPLY DUCT DOWNRETURN / EXHAUST DUCT UPRETURN / EXHAUST DUCT DOWNDUCT OFFSET UP DUCT OFFSET DOWNRCEILING DIFFUSER. - ROUND NECK - # THROW DIRECTIONSLINEAR DIFFUSER. SEE SCHEDULE FOR INFORMATION.RETURN or EXHAUST GRILLE - (R = REGISTER)FLEXIBLE DUCTSPIN TAP WITH VOLUME CONTROL DAMPERHUMIDISTATCARBON DIOXIDE SENSORCARBON MONOXIDE SENSORDUCT ACCESS DOORSQUARE / RECTANGULAR DUCT TRANSITIONSQUARE/RECTANGULAR TO ROUND DUCT TRANSITIONUNDER CUT DOORSYMBOLMECHANICAL PIPING SYMBOLS LEGENDDESCRIPTIONABRV.TOP PIPE CONNECTIONPIPING CAPSTATIC PRESSURE SENSORROUND DUCT ELBOW UPROUND DUCT ELBOW DOWNFLEXIBLE DUCT CONNECTION (TO EQUIPMENT)TRIPLE DUTY VALVE WITH MEASURING CONNECTIONSHOSE BIBPRESSURE GAGE W/ SHUT-OFFSUPPLY DIFFUSER - RECTANGULAR - MULTI-DIRECT.SIDEWALL SUPPLY or RETURN GRILLE - (R = REGISTER)ELBOW WITH TURNING VANESFLOW ARROWBDDMDDTHSP2COCO#TAGTAGCFMU1HWSCWSHWRCWRCHWSCHWRGDRLPSMPSHPSLPRFOSFORLOUVERED DOORLREVISION NUMBERRETURN OR EXHAUST AIRSUPPLY OR OUTSDIE AIRLAT.LATENT11DEMOLITION DRAWING KEYNOTEXTRRXCDSDSG/EGLDRG/EGADVDBDDMDFDHFDSDHSDDDFD/SDHFD/SDRA or EASA or OAHWSCWSHWRCWRCHWSCHWRLEAVING AIR TEMPERATUREL.A.T.LOW PRESSURE STEAM SUPPLY PIPING (0-15 PSIG)MEDIUM PRESSURE STEAM SUPPLY PIPING (16-60 PSIG)HIGH PRESSURE STEAM SUPPLY PIPING (61 TO 200 PSIG)LOW PRESSURE STEAM CONDENSATE RETURNHIGH PRESSURE STEAM CONDENSATE RETURNHPRPUMPED STEAM CONDENSATEPCVENT PIPINGVMECHANICAL ABBREVIATIONSSTEAM TRAPTFLEXGDRLPSMPSHPSLPRFOSFORHPRPCVDESCRIPTIONABRV.ABOVE FINISHED FLOORAFFELEVATION FROM DATUMELEV.NOT TO SCALENTSNOT IN CONTRACTNICFLANGED CONNECTIONCONCENTRIC PIPE REDUCERECCENTRIC PIPE REDUCERBVBFVPVGVGBVCVCWCITY (DOMESTIC) WATERCWCEILING RADIATION FIRE DAMPERRDGENERAL MECHANICAL NOTES (ALL DRAWINGS):1.MECHANICAL CONTRACTOR SHALL PROVIDE ALL MATERIALS AND EQUIPMENTAND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLEHVAC SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED ANDREQUIRED BY CODE.2.THE CONTRACT DOCUMENT DRAWINGS ARE DIAGRAMMATIC ONLY, AND AREINTENDED TO CONVEY THE SCOPE AND GENERAL ARRANGEMENT OF WORK.3.ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BE VERIFIED BY THECONTRACTOR BY FIELD INSPECTION PRIOR TO BIDDING. ANY INTERFERENCESTO INSTALLATION SHALL BE NOTED AND THE CONTRACTOR SHALL INCLUDE INHIS BID PRICE THE COST TO AVOID OR RELOCATE ALL ITEMS, INCLUDINGITEMS OF OTHER TRADES, THAT INTERFERE. ALL WORK SHALL BECOORDINATED WITH ALL TRADES INVOLVED. ALL OFFSETS, RISES,TRANSITIONS AND DROPS IN DUCTS AND PIPING AROUND OBSTRUCTIONSSHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER.4.VERIFY ALL EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIEDDRAWINGS. VERIFY AND PROVIDE DUCT TRANSITIONS OR PIPE ADAPTERS TOFURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL DIMENSIONSBEFORE FABRICATION.5.PROVIDE ACCESS IN WALLS & CEILINGS TO ACCESS ALL EQUIPMENT,VALVES, CONTROL DEVICES, VOLUME DAMPERS, AND FIRE/SMOKEDAMPERS.6.FOLLOW MANUFACTURE'S RECOMMENDATIONS FOR INSTALLATION OFEQUIPMENT. ALSO REFER TO TYPICAL DETAILS FOR INSTALLATION OFEQUIPMENT.7.ALL MATERIALS FURNISHED, AND ALL WORK PERFORMED BY THEMECHANICAL CONTRACTOR SHALL BE IN ACCORDANCE WITH ALLAPPLICABLE CODES AND REGULATIONS, INCLUDING BUT NOT LIMITED TO THELATEST APPLICABLE EDITIONS OF NFPA, IEEE, OSHA, SMACNA,INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, ANDANY STATE, COUNTY, AND LOCAL CODES.8.ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED SUFFICIENTLY ANDANY ADDITIONAL SUPPORT SHALL BE PROVIDED AS REQUIRED TO PROVIDEVIBRATION FREE AND SAFE INSTALLATION. ALL MISCELLANEOUS STEELREQUIRED AND/OR AS SHOWN IN DETAILS FOR DUCTWORK, AND EQUIPMENT(UNLESS OTHERWISE NOTED) SHALL BE FURNISHED AND INSTALLED BY THEMECHANICAL CONTRACTOR. SUPPORT ALL DUCTWORK, PIPING ANDEQUIPMENT MOUNTED ABOVE THE CEILING DIRECTLY FROM THE STRUCTURE.ALL ATTACHMENTS TO BEAMS, TRUSSES, OR JOIST SHALL BE MADE ATPANEL POINTS WITH BEAM CLAMPS MEETING MSS STANDARDS.9.ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH NEC ANDELECTRICAL SPECIFICATIONS FOR THIS PROJECT.DUCTWORK GENERAL NOTES (ALL DRAWINGS):1.ALL DUCTWORK INDICATED IS SCHEMATIC AND SHOW ONLY RELATIVEPOSITIONS. PROVIDE OFFSETS, RISES, TRANSITIONS AND ELBOWS ASNEEDED TO INSTALL PROPERLY.2.PROVIDE ACCESS DOORS IN DUCTWORK FOR OPERATION, ADJUSTMENT,AND MAINTENANCE OF ALL HVAC DEVICES, FANS, DAMPERS, (FIRE, SMOKE,BALANCING) COILS, AND TERMINAL EQUIPMENT.3.LOCATIONS OF TERMINAL DEVICES, AIR OUTLETS AND INLETS AREAPPROXIMATE. LOCATE PER THE ARCHITECTURAL DRAWINGS AND TOAVOID OTHER TRADE'S WORK. COORDINATE LOCATIONS WITH OTHERTRADES. CONSULT ARCHITECT/ENGINEER FOR CLARIFICATION IF CONFLICTSOCCUR.4.DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE FACE-TO-FACE DIMENSIONSAND DO NOT INCLUDE DUCT LINER WHERE SPECIFIED. INCREASEDIMENSIONS OF LINED DUCTWORK TO PROVIDE FREE INSIDE AREA EQUALDIMENSIONS SHOWN. REFER TO THE SPECIFICATIONS FOR LOCATION OFLINED DUCTWORK.5.FINAL CONNECTIONS FROM HIGH VELOCITY MAIN DUCTS TO AIR TERMINALUNITS SHALL BE MADE WITH FLEXIBLE DUCTWORK NOT EXCEEDING 3 FEETIN LENGTH. CONNECTIONS BETWEEN LOW VELOCITY DUCTWORK AND/ORTERMINAL UNITS TO AIR INLETS AND OUTLETS SHALL BE MADE WITHFLEXIBLE DUCTWORK NOT EXCEEDING 6 FEET IN LENGTH. LONGER DUCTRUN OUTS SHALL BE CONSTRUCTED OF HARD DUCT OF THE SAMEMATERIAL SPECIFIED FOR THE SYSTEM SERVED AND INSULATED ASSPECIFIED FOR THAT SYSTEM. FLEXIBLE DUCTWORK SHALL BE OF THEPRESSURE CLASS AND FACTORY INSULATED AS SPECIFIED FOR THESYSTEM WHERE INSTALLED.6.FLEXIBLE DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH THEMANUFACTURER'S INSTRUCTIONS WITHOUT ANY SAGS, SHARP TURNS ORKINKS. AT THE MINIMUM, THE FLEXIBLE DUCTWORK SHALL BE FASTENED TOTHE HARD DUCT BY A NYLON STRAP SECURED BY SHEETMETAL SCREWSTO PREVENT SLIPPING OFF FROM COLLAR.7.PROVIDE VOLUME DAMPERS AT EACH AIR OUTLET, AIR INLET AND TERMINALDEVICE AND AT EACH BRANCH TAKE-OFF CONNECTION FROM THE MAIN.4'-0" MAXIMUMTHRU BOLT4'-0" MAXIMUMNOTES:1. FLEXIBLE DUCT SHOULD EXTEND STRAIGHT FORSEVERAL INCHES FROM RECTANGULAR DUCTCONNECTION BEFORE BENDING.2. FLEXIBLE DUCT SHOULD NOT EXCEED 6'-0" IN LENGTH.USE RIGID ROUND DUCTWORK WHEN RUNOUTS EXCEED6'-0".20 GAUGE x 1 1/2" METAL STRAP CONNECTEDTO STRUCTURE ABOVE (TYPICAL)INSULATIONROUND DUCTMAX. SAG 1/2" PER FOOT OF SUPPORTSPACING.3M001FLEXIBLE DUCT RUN-OUT SUPPORT DETAILNO SCALEMETAL BANDS (TYPICAL)SUPPLY INLETSUPPLY AIR DUCTFLEXIBLE DUCT OVERRIGID DUCT WITH METALBAND, "KRIMP" RIGIDDUCT AS REQUIREDINSULATED FLEXIBLEDUCT (MAXIMUM 6'-0"IN LENGTH)T-BAR DIFFUSER WITH "INTERNAL INSULATION(30 NC MAX. @ GIVENAIR QUANTITIES, SEEPLANS)ROUND RIGID SUPPLY DUCT WITH 1"FLEXIBLE DUCT WRAP"KRIMP" END AS REQUIRED1" DUCTWRAPINSULATION WITH FOILVAPOR BARRIERSPIN-IN FITTING WITHINTEGRAL DAMPER AND 45DEGREE EXTRACTOR (REFERTO SPIN-IN FITTING DETAIL)FOIL TAPESHEET METAL SPACER(DAMPER OPERATOR TOCLEAR INSULATION)RIVET OR SHEET METALSCREWNOTE:1. DIFFUSER SHALL BE COMPLETE WITH CENTER "T"-BAR AND OUTER "T"-BAR(ON INLET SIDE).4M001FLEXIBLE DUCT WITH LINEAR SUPPLY AIR DIFFUSER DETAILNOT TO SCALEWALLLEAVE 1" WIDE REVELSLOT IN CEILINGBEHIND DIFFUSER FORRETURN AIR (TYPICAL)5M001RETURN/EXHAUST GRILLE PLENUM DETAILNO SCALECEILINGGRILLEOPEN END TOCEILING PLENUM8" MINIMUMWHERE SHOWN PROVIDE RETURN AIR PLENUM FULLSIZE OF GRILLE FACE ON TOP OF RETURN GRILLE.(MOST ROOMS USE RETURN AIR LIGHT FIXTURESAND DO NOT USE RETURN AIR GRILLE.)WW1 1/2W1 1/2W1"1"1"2"R1"1"NOTE:PROVIDE RADIUS ELBOWS, 18" AND LARGER WITH TURNINGBLADES AT 1/3 AND 1/2 THE WIDTH OF THE DUCT FROM THEINSIDE RADIUS. TURNING BLADES SHALL BE PROVIDED WITHHEMMED ENDS. (SEE SECTION 15840 OF MECHANICALSPECIFICATIONS FOR ADDITIONAL DUCT CONSTRUCTIONINFORMATION AND RESTRICTIONS.)SQUARE 90° ELBOWW/ TURNING VANESROUND 90° ELBOWDETAIL OF TURNING VANESSQUARE 45° ELBOWROUND 45° ELBOWRECTANGULAR TRANSITIONRECT. TO ROUND TRANSITIONSLOPE NOT TOEXCEED 1" IN 4"SLOPE NOT TOEXCEED 1" IN 4"WW2M001LOW VELOCITY DUCTWORK DIAGRAMSNO SCALE2 X WIDTHW OPEN END1/2 W.1" LINING INDUCTWORKTRANSFER DUCT(SIZE PER PLANS)DUCTWORKHANGERSANCHOR ANGLE TOWALL & DUCTWORKNO TURNING VANESTO BE INSTALLED INELBOWOPEN ENDEXISTING WALLCLIP ANGLE1M001TRANSFER DUCT DETAILNOT TO SCALESEE TRANSFER AIR DUCTSCHEDULE FOR SIZESWATER SOURCE HEAT PUMP UNIT SCHEDULETAGTYPEFAN DATACOOLING DATAHEATING DATASOURCE WATERELECTRICAL DATABASIS OFDESIGNMODELREMARKSS/A CFMO/A CFME.S.P.SENS. MBHTOTAL MBHEWT (°F)TOTAL MBHEWT (°F)GPMWPD (FT)FAN HPMCA/MOCPVOLTAGE/PHASEHP 3-34HORIZONTAL400500.59.111.19014.0702.55.50.14.2/15277/1CARRIER50PCH0121-7HP 3-35HORIZONTAL300350.56.06.2908.37022.50.14.2/15277/1CARRIER50PCH0071-7REMARKS:1. UNITS SHALL BE PROVIDED WITH INTEGRAL DISCONNECT SWITCH.2. UNITS SHALL BE PROVIDED WITH AUTOFLOW REGULATOR W/ BALL VALVES.3. PROVIDE DRAIN PAN FOR CONDENSATE DRAINAGE.4. APPROXIMATE UNIT HEATING & COOLING OPERATION ENTERING AIR CONDITIONS: 78.0°F DB/66.7°F WB.5. UNIT DISCHARGE AIR TEMPERATURES SHALL NOT EXCEED 60°FDB FOR COOLING OPERATION.6. UNIT DISCHARGE AIR TEMPERATURES SHALL NOT BE LESS THAN 85°F DB FOR HEATING OPERATION.7. PROVIDE LITTLE GIANT VCMA-15 CONDENSATE PUMP (1/50 HP, 120/1) FOR EACH NEW HEAT PUMP.DIFFUSER NECK SIZE & RUNOUTLENGTH SCHEDULECFM RANGENECK SIZEMAX LENGTH0-504"Ø4'-0"51-1256"Ø4'-0"126-2308"Ø5-0"231-42010"Ø5'-0"421-65012"Ø6'-0"651 - 90014"Ø6'-0"NOTE: DIAMETER OF DIFFUSER FLEXIBLE DUCTCONNECTOR IS EQUAL DIFFUSER NECK SIZE. SEEPLANS AND SPECIFICATIONS FOR FACE TYPE ANDMODEL NUMBERS.TRANSFER AIR DUCT SCHEDULEDESIGNATIONDUCTSIZECFMRANGET18 x 80-200T210 x 10201-400T314 x 10401-600T414 x 14601-900T518 x 14901-1200T624 x 141201-1700T724 x 181701-2400T828 x 182401-3000NOTES:1. SIZING BASED ON 0.05"/100 FT. P.D. ~ 700 FPM2. REFER TO DETAIL FOR DUCT CONFIGURATION.3. PROVIDE 1" THICK ACOUSTICAL LINER.FILTER RACKFLEXIBLE CONNECTORSUPPLY AIRSTRAINERCWSCWRBALL VALVE W/P/T PORTS UNION (TYP.)6M001WATER SOURCE HEAT PUMP DETAILNOT TO SCALEBRAIDED FLEXIBLE HOSE3/8" D. VINYL TUBING FOR PUMPEDCONDENSATE, PIPE TO SAFE-WASTECONDENSATE PUMP FURNISHEDWITH UNIT, MOUNT ON PAN2" DEEP CONDENSATE DRAIN PANWITH WATER SENSOR SWITCH1-1/2" DEEP TRAP FROM HEAT PUMPCONDENSATE DRAINAUTOMATIC FLOW LIMITING VALVEFLOW/NO FLOW VALVESPIN COLLAR W/ VOLUME DAMPERDUCT. LENGTH NECESSARY TO MEET MAXIMUM FLEX RIGID DUCT WITH INSULATION SAME SIZE AS FLEX SUPPLY AIR DIFFUSERNYLON TIES (TYP. 2 PL)DUCT LENGTH REQUIREMENTSDUCT. SEE DRAWINGS FOR SIZE.SOUNDLINED OR INSULATED SUPPLY AIR 7M001SUPPLY AIR DIFFUSER CONNECTION DETAILNOT TO SCALEPROVIDE REDUCER WHERE RUNOUT SIZE IS LARGER THAN DIFFUSERCONNECTION. WRAP WITH INSULATION.FLEX DUCT (6'-0" MAX) W/EXTERNAL INSULATIONDIFFUSER & GRILLES SCHEDULETAGBASISOFDESIGNMODELFACESIZEMAX. CFMP.D.IN.W.C.THROW@ 50FPMMAX.NCREMARKSATITUSTMS24/244000.1513251,2,3BTITUS350RL24/122000.05-201,2,3,4CTITUS350RL24/2410000.05-201,2,3,4REMARKS:1. MATCH FINISH TO EXISTING DIFFUSERS.2. REFER TO DIFFUSER RUNOUT SCHEDULE FOR CONNECTION SIZE.3. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPE AND MOUNTINGREQUIREMENTS.4. PROVIDE RETURN SHEET METAL BOOT WITH 1" ACOUSTICAL LINER ABOVE ALLRETURN AIR GRILLES.