Loading...
HomeMy WebLinkAboutP001 - Plumbing Data Sheet123456781011121314151617BA91234567810111213141516179DrawnProject ManagerCheckedContract Drawing DateProject NumberQPNMLKJHGFEDCBA18191819QPNMLKJHGFEDCB202120212222TSRTSRRevit Template Versionv16: 2017.10.05This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information itcontains may be copied or used for other than the specific project for which it was prepared without the written consent of BaxterHodell Donnelly Preston, Inc. CINCINNATI COLUMBUS RALEIGH PITTSBURGH ATLANTA LAWRENCE DIGENNARO, ARCHITECT 302 WEST THIRD STREET SUITE 500 CINCINNATI, OHIO 45202 PHONE 513.271.1634HIG02.21THE HARTFORD GROUP - 3RD FLOOR RENOVATION 501 PENNSYLVANIA PKWY #400 INDIANAPOLIS, IN 46280 No.Issue/Revision/Submission Date 1 ISSUED FOR BID AND PERMIT 12/14/20182016.05.27P001PLUMBING DATA SHEETZPKJRHDCP HOT WATER RECIRC. PUMPEXTERNAL WALL HYDRANTINTERIOR HOSE BIBBGATE VALVECHECK VALVECVPRESSURE REDUCING VALVEGAS SOLENOID VALVEMIXING VALVETEMPERATURE AND PRESSURE RELIEF VALVET&PGAS COCKBALANCING VALVEBVBALL VALVEBACK FLOW PREVENTERBFPSHOCK ARRESTORPRESSURE GAUGEPGPIPE UNIONPIPE CAPCLEAN OUT, EXPOSEDCOCLEAN OUT, FLOORCOPIPE TEE DOWNPIPE DOWNPIPE UPEXISTING PIPING TO BE REMOVED - RXGLOW PRESSURE GAS PIPINGGHOT WATER RETURN PIPINGHWRHOT WATER PIPINGHWCOLD WATER PIPINGCWVENT PIPINGVSTORM PIPINGSTSTSANITARY PIPINGSANABRV.SYMBOLDESCRIPTIONPLUMBING LEGENDRX (X)DISCONNECT FROM EXISTINGCONNECT TO EXISTINGSANITARY PIPING BELOW GRADESANSATRAP PRIMER PIPINGTPTPKITCHEN WASTE PIPING BELOW GRADEKW(TO GREASE INTERCEPTOR)KWVKITCHEN WASTE PIPINGKW(TO GREASE INTERCEPTOR)KWSTORM PIPING BELOW GRADESTSTFLOOR DRAINFDPIPE TEE UPTRAPUTILITY METERTHERMOMETERSTRAINERSANSANPRESSURE REGULATING VALVEROOF DRAINRDEXEX (X)(X) DESIGNATES SERVICETRAP PRIMER PIPING BELOW GRADETPTPCOLD WATER PIPING BELOW GRADECWGLOW PRESSURE GAS PIPING BELOW GRADEGEXISTING PIPING BELOW GRADE TO REMAIN -EXEX (X)(X) DESIGNATES SERVICEEXISTING PIPING BELOW GRADE TO BE REMOVED - RXRX (X)(X) DESIGNATES SERVICENOTE: SOME SYMBOLS MAY NOT BE USED ON DRAWINGS.FOFUEL OIL PIPINGFOFOFUEL OIL PIPING BELOW GRADEFOMCWCWHWHWREXISTING PIPING TO REMAIN -(X) DESIGNATES SERVICEEMERGENCY STORM PIPINGESTEST1.CONFORM TO ALL APPLICABLE CODES (LOCAL, STATE, NATIONAL CODES, NFPA,OSHA, ETC.), GOVERNMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS,AND APPLICABLE STANDARDS.2.OBTAIN PERMITS AND PAY ALL FEES. ARRANGE FOR ALL REQUIRED TESTS,INSPECTIONS AND APPROVALS.3.FURNISH ALL PLUMBING FIXTURES, EQUIPMENT AND MATERIAL INDICATED ANDSHOWN ON DRAWINGS AND INSTALL COMPLETE AND PLACE IN PROPEROPERATION.4.PROVIDE SANITARY WASTE AND VENT PIPING AND SANITARY SEWER AND EXTENDTO EXISTING BUILDING FACILITIES. CONTRACTOR SHALL MAKE THE TIE-INS TO THEEXISTING SERVICES WHERE INDICATED ON DRAWINGS. EXISTING LINE SIZES,CONDITIONS, INVERT ELEVATIONS, AND CAPACITIES SHALL BE FIELD VERIFIED.CLEAN AND TEST PIPING FOR PROPER OPERATION BEFORE FINAL CONNECTION FORALL UTILITIES. IMMEDIATELY REPORT TO THE ARCHITECT OR ENGINEER ANYINSTANCES WHERE CONNECTIONS CANNOT BE MADE BETWEEN NEW ANDEXISTING SYSTEMS AS INDICATED ON PLANS. NO EXTRA COMPENSATION WILL BEGRANTED FOR NEW WORK THAT MUST BE ABANDONED AND REPLACED BECAUSELOCATION AND ELEVATION OF EXISTING WAS NOT DETERMINED BEFORE STARTINGNEW WORK.5.EXTEND DOMESTIC WATER FROM EXISTING BUILDING FACILITIES AS INDICATED ONDRAWINGS. INSTALL DOMESTIC WATER DISTRIBUTION PIPING TO ALL FIXTURESAND EQUIPMENT REQUIRING SAME. INCLUDE ALL FITTINGS, VALVES, HANGERS,INSULATION, AND OTHER ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION.6.PROVIDE PLUMBING FIXTURES, DRAINS AND EQUIPMENT WITH ALL PLUMBING CODEREQUIRED TRIM, CONTROLS AND ACCESSORIES.7.INSULATE HOT AND COLD WATER PIPING PER ASHRAE GUIDELINES - MINIMUM OF 1INCH THICK FIBERGLASS INSULATION WITH ALL SERVICE JACKET.8.SEWERS TO BE PITCHED A MINIMUM OF 1/4" PER FOOT FOR SIZES 3" AND UNDER,AND 1/8" PER FOOT FOR SIZES 4" AND LARGER OR TO GRADES INDICATED ONDRAWINGS.9.CHANGES IN DIRECTION AND BRANCH CONNECTIONS SHALL BE MADE WITHAPPROVED DRAINAGE FITTINGS COMPATIBLE WITH THE PIPING SYSTEM MATERIALIN WHICH IT IS INSTALLED.10.FIXTURES AND SANITARY DRAINS SHALL BE VENTED AS INDICATED ON DRAWINGSAND IN ACCORDANCE WITH CODE. VENTS ARE TO BE EXTENDED TO EXISTINGBUILDING FACILITIES OR UP THROUGH ROOF.11.THIS PROJECT HAS A RETURN AIR PLENUM AND PVC SHALL NOT BE INSTALLED INRETURN AIR PLENUMS, USE NO-HUB CAST IRON, DWV COPPER ASTM B306 PIPING,OR PRESS FIT STAINLESS STEEL PIPING IN PLENUMS.12.EXISTING PVC PIPING IN PLENUM CEILINGS SHALL BE INSULATED TO MEET PLENUMRATINGS. IF FOUND IN PLENUM, NOTIFY THE ARCHITECT.13.INCLUDE UNIONS, OR OTHER DISCONNECT MEANS, STOPS OR VALVES FORISOLATION OF FIXTURES AND EQUIPMENT. VALVES TO BE FULLY COMPATIBLEWITH PIPING FOR SERVICE INTENDED AS MANUFACTURED BY APOLLO, NIBCO,WATTS, CRANE OR OTHER APPROVED MANUFACTURER. INCLUDE HOSE OR DRAINVALVES AT LOW POINTS WHERE FIXTURES CANNOT BE USED FOR DRAINAGE.14.HANGERS ON INSULATED PIPE SHALL BE OUTSIDE OF INSULATION, SIZEDACCORDINGLY AND WITH SUFFICIENT SADDLE TO PROTECT INSULATION.15.FLUSH, VENT AND SANITIZE ALL WATER PIPING WITH EQUIVALENT SOLUTION OF50 PPM OF AVAILABLE CHLORINE UPON COMPLETION. COMPLY WITH PLUMBINGCODE REQUIREMENTS FOR SANITIZATION.16.COORDINATE FINAL PIPE ROUTING WITH ARCHITECT AND OTHER TRADES.17.NO WORK SHALL BE INSTALLED UNTIL ALL TRADES HAVE SIGNED OFF ON THECOORDINATION DRAWINGS AND THE COORDINATION DRAWINGS ARE APPROVEDBY THE ARCHITECT.18.COORDINATE AND FIELD VERIFY SANITARY PIPE ROUTING WITH OWNER ON THISFLOOR AND FLOOR BELOW. DUE TO UNKNOWN CONDITIONS IN THE CEILING OFSPACE BELOW THIS FLOOR, PIPING MAY BE RE-ROUTED TO MISS CONFLICTS WITHDUCTWORK AND STRUCTURE.19.NEW SUPPLY BRANCH LINES MAY USE "PRESS TYPE" HEAVY DUTY HIGHCOMPRESSION COPPER FITTINGS AND COUPLINGS WITH O-RING SEALS ORTRADITIONAL LEAD-FREE SOLDER JOINTS AND FITTINGS. TEE-DRILL FITTINGS WITHBRAZED JOINTS ARE PERMITTED AT THE SUPPLY MANIFOLDS BEHIND BANKS OFPLUMBING FIXTURES.20.THE INDICATED SCOPE OF THE DRAWINGS ARE FOR GUIDANCE ONLY ANDREPRESENTS THE LIMIT OF GENERAL CONSTRUCTION WORK. THIS CONTRACTORMAY BE REQUIRED TO DO WORK IN AREAS OUTSIDE OF THIS SCOPE WHERENECESSARY TO DEMOLISH, INSTALL NEW SYSTEMS OR EXTEND TO EXISTINGSYSTEMS IN ORDER TO PERFORM THE WORK INDICATED ON THESE DRAWINGS.COORDINATE WITH OWNER'S REPRESENTATIVE TO GAIN ACCESS TO ADJOININGSPACES AND TO MINIMIZE DISRUPTION OF SERVICES.PLUMBING DEMOLITION NOTES:1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PLUMBING RELATEDDEMOLITION WORK. VERIFY WITH ARCHITECT ALL WALLS, PARTITIONS,CEILINGS, ETC. THAT ARE TO BE REMOVED.2. DEMOLTION SHALL BE COORDINATED AND SCHEDULED WITH THE OWNER,PRIOR TO BEGINNING CONSTRUCTION.3. DEMOLITION WORK SHALL BE REMOVED COMPLETELY INCLUDING ALLASSOCIATED APPURTENANCES. UNDER NO CIRCUMSTANCES SHALL WORK BELEFT ABANDONED IN PLACE, UNLESS OTHERWISE SPECIFIED. REMOVE ALLUNUSED PIPING AND HANGERS AND DISCARD.4. ANY SALVAGEABLE MATERIAL AT THE REQUEST OF THE OWNER SHALL BERETURNED TO THE OWNER DURING DEMOLITION.5. CAP ALL PIPE CUT OR DISMANTLED DURING DEMOLITION TO MAINTAINSYSTEM INTEGRITY. CAP BRANCHES AT MAINS TO PREVENT DEAD LEGS.PATCH HOLES IN FLOORS AND WALLS TO MATCH EXISTING - COORDINATEWITH GC.6. THE PIPING SHOWN ON THESE DRAWINGS IS DIAGRAMMATIC ANDSHOWS THE BASIC ROUTING OF THE MAINS. THE CONTRACTOR SHALL BERESPONSIBLE TO FIELD VERIFY ALL EXISTING PIPING BOTH FOR SIZE ANDLOCATION. EXISTING PIPING MAY BE REUSED WHERE PRACTICAL. FIELDVERIFY BEST ROUTING FOR NEW PIPING INSTALLATIONS AND MAKENECESSARY ADJUSTMENTS IN THE FIELD.DRAIN VALVE D HW CW THERMOMETERELECTRIC WATERSTORAGE TANKWATER HEATER EXPANSION TANK.150 PSIG MAXIMUM, BUTYL DIAPHRAGMWITH POLYPROPYLENE LINER.EXPANSION TANK SHALL BE AMTROLOR APPROVED EQUAL.UNION (TYP)BALL VALVE (TYP)SHELF WITH DRAIN PANWATER HEATER SUPPORTED BYTHREADED RODS (TYP OF 4)SUSPEND RODS FROM STRUCTUREABOVE. CONTRACTOR ISRESPONSIBLE FOR PROVIDINGSTRUCTURAL SUPPORT.3/4" DRAIN PIPE FROMDRAIN PAN TO EXTENDAND SPILL TO FLOORDRAIN. CONCEAL PIPINGWITHIN WALL CAVITY.ASME COMBINATION TEMPERATUREAND PRESSURE RELIEF VALVE,EXTEND PIPE TO SPILL TO APPROVEDWASTE RECEPTORDISCHARGE DRAIN LINE TO BE SAME SIZEAS FROM OUTLET OF TEMPERATURE ANDPRESSURE RELIEF VALVE. TERMINATEOVER FLOOR DRAIN.1P001ELECTRIC WATER HEATER (CEILING MOUNTED)NOT TO SCALE1.WATER/ICE SYSTEM. SEE ARCHITECTURAL DRAWING FOR MORE INFORMATION.2.WATTS KWIKSTOP QUARTER TURN SUPPLY STOP (TYPICAL).3.PROVIDE DRAIN BOX (SIOUX CHIEF MODEL # 696-3) BELOW COUNTER FORWATER HEATER DRAINS.4.CHROME PLATED PVC ESCUTCHEON (TYPICAL).5.SEE PLANS FOR CONTINUATION OF PIPING.6.TRAP PRIMER, ZURN Z1022CP - EXTEND TO DRAIN BOX.7.WATER FILTER MOUNTED TO BASE CABINET OR WALL WITH OFFSET CLAMP -(AQUA-PURE AP200)8.SHOCK ARRESTOR SIOUX CHIEF MODEL #660-TR0B.9.DUAL CHECK BACKFLOW PREVENTER (WATTS SERIES 7)10.DRILL HOLE AND PROVIDE GROMMET THROUGH COUNTER TOP.11.INSTANT HOT WATER DISPENSERS WITH FAUCET. SEE ARCHITECTURALDRAWINGS FOR MORE INFORMATION.12.OUTLET BOX WITH SHUT OFF VALVE AND SHOCK ARRESTOR MOUNTED INWALL BEHIND ICE MAKER (SIOUX CHIEF # 696-1010MF).13.EXTEND 1' DRAIN FROM ICE MAKER TO HUB-DRAIN. PROVIDE AIR GAP14.2" HUB-DRAIN WITH STRAINER. EXTEND HUB 2" ABOVE FINISH FLOOR, ORFUNNEL FLOOR DRAIN. COORDINATE LOCATION OF DRAIN WITH ICE MAKERPROVIDER.15.EXTEND WATER LINE TO EACH REFRIGERATOR WITH ICE MAKER.3/4" CWIN WALLS-11/2" HWIN WALLBASECABINETHW CWSAN2"FLOORV2P001BREAK ROOM SINK RISER DIAGRAMNOT TO SCALEREFRIGERATORREFRIGERATORCOFFEE MAKER32465510989898ELECTRIC WATER HEATER SCHEDULEMARKDESCRIPTIONMANUFACTURER &MODEL NUMBER(BASIS OF DESIGN)LOCATIONSTORAGEVOLUMEGPH RECOVERY @90 DEG F RISEPOWERVOLTAGEEFFICIENCYNOTESWH-1ELECTRICWATER HEATERBRADFORD WHITELE120L3-3STORAGE ROOM19 GALLONS16 GALLONS4.0 KW277 VOLT,1 PHASE98%1, 2, 3, 4NOTES -1. PROVIDE EXPANSION TANK. REFER TO EXPANSION TANK SCHEDULE ON THIS DRAWING.2. PROVIDE HEAT TRAPS ON WATER HEATER.3. DISCONNECTS BY PLUMBING CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR.4. ACCEPTABLE MANUFACTURERS - A.O.SMITH, BRADFORD WHITE, LOCHINVAR.EXPANSION TANK SCHEDULEMARKDESCRIPTIONMANUFACTURER &MODEL NUMBER(BASIS OF DESIGN)LOCATIONTANK SIZEACCEPTANCEVOLUMENOTESET-1DOMESTICWATEREXPANSIONTANKAMTROL ST-5AT WATERHEATER WH-12 GALLONS0.9 GALLONS1, 2NOTES -1. WORKING PRESSURE - 150 PSIG.2. MAXIMUM SYSTEM TEMPERATURE - 140 DEG F.3. ACCEPTABLE MANUFACTURERS - WESSELS, WATTSPLUMBING FIXTURE CONNECTION SCHEDULEMARKFIXTURE TYPECWHWWASTEVENTMANUFACTURERMODEL NUMBERFAUCET/FLUSH VALVEACCESSORIESMS-2STAINLESS STEEL SINGLE BOWLDROP-IN SINK1/2"1/2"1 1/2"1 1/4"ELKAY MODELLRAD151755-1MOEN MODEL: S5170ASSE 1070 TYPE MIXING VALVE SETAT 105°F1, 2, 7UB-1UTILITY BOX1/2"1/2"2"1 1/2"GUY GRAYT200---1, 2, 7IM-1ICE MAKER CONNECTION ATREFRIGERATOR1/2"---------SIOUX CHIEF # 696-1010MF3/8" FLEXIBLE HOSE WITH BRAIDEDSTAINLESS STEEL JACKET(WATTS # 4548DWSS)SHOCK ARRESTOR8CM-1COFFEE MAKER CONNECTION1/2"---------DAHL # 211-QG3-30-14WHA3/8" FLEXIBLE HOSE WITH BRAIDEDSTAINLESS STEEL JACKET(WATTS # 4548DWSS)SHOCK ARRESTOR8REMARKS:1. PROVIDE ALL REQUIRED COMPONENTS FOR COMPLETE FIXTURE ROUGH-IN, I.E., SUPPLIES & STOPS - MCGUIRE #H2165LK-SS, TRAPS - MCGUIRE #8912, CARRIERS - ZURN 1200 SERIES, GRID DRAINS & TAILPIECES - MCGUIRE #155A, ETC NOT ALL REQUIRED COMPONENTS ARESPECIFIED ABOVE.2. SEE PLANS AND RISERS FOR VENT SIZES AND CONNECTIONS.3. FIXTURES SHALL BE ADA COMPLIANT. PROVIDED WITH ADA COMPLIANT ACCESSORIES. MOUNT ADA COMPLIANT. SEE ARCHITECTURAL PLAN FOR ELEVATIONS.4. COORDINATE VALVE INSTALLATION WITH ADA GRAB BAR. VALVE SHALL BE LOCATED SO THAT GRAB BAR DOES NOT INTERFERE WITH USE OF VALVE. PROVIDE EXTENSION AS REQUIRED.5. PROVIDE MCGUIRE PRO-WRAP WHITE ANTI-MICROBIAL INSULATING WRAP ON EXPOSED UNDER LAVATORY OR SINK SUPPLY AND WASTE PLUMBING.6. FIXTURES SHALL HAVE AN IN-SINK-ERATOR EVOLUTION EXCEL GARBAGE DISPOSAL RATED @ 1 HP INSTALLED PRIOR TO FIXTURE ROUGH-IN.7. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE PLAN LOCATION DIMENSION REQUIREMENTS AND COORDINATE PLUMBING ROUGH-IN ACCORDINGLY. COORDINATE EQUIPMENT WITH INTERIOR DESIGN DRAWINGS.8. PROVIDE DUAL CHECK BACKFLOW PREVENTER (WATTS # LF7C).DRAIN AND SPECIALITIES SCHEDULEMARKDESCRIPTIONMANUFACTURER & MODEL NUMBERNOTESTP-1TRAP PRIMER - PRESSUREDIFFERENTIAL TYPEZURN Z1022-DU2-DU4PROVIDE MULTIPLE OUTLET DISTRIBUTION AS REQUIREDSHOCK ARRESTOR SCHEDULEMARKSFU'sCONN. SIZEMODEL NO.SA - A1 TO 111/2"652-ASA - B12 TO 323/4"653-BSA - C33 TO 601"654-CSA - D61 TO 1131"655-DSA - E114 TO 1541"656-ESA - F155 TO 3301"657-FMODEL NUMBERS BASED ON SIOUX CHIEF PISTON TYPEARRESTORSBACKFLOW PREVENTER SCHEDULEMARKDESCRIPTIONMANUFACTURER & MODEL NUMBERLOCATIONNOTESBP-1DUAL CHECK VALVEASSE-1032WATTS SD-2CARBONATED BEVERAGE MACHINES---BP-2DUAL CHECK VALVEASSE-1024WATTS LF7COFFEE MAKERS, REFRIGERATORS---NOTES -1. PROVIDE AIR GAP FITTING. ROUTE DRAIN TO AN APPROVED WASTE RECEPTOR.CLEANOUT SCHEDULEMARKDESCRIPTIONMANUFACTURER & MODEL NUMBERNOTESOPTIONSFCOFLOOR CLEANOUTZURN ZN-1400-BP-VPFULL SIZE OF PIPE, VANDAL-PROOF,NICKEL-BRONZE TOP-CF FOR CARPET-X FOR TILEWCOWALL CLEANOUTZURN Z-1441-VPSTAINLESS STEEL ACCESS COVER,VANDAL-PROOF, FULL SIZE OF PIPE.COCLEANOUT FERRULEZURN Z-1440-BPFULL SIZE OF PIPE.117REFRIGERATORICE & WATERSYSTEM1-1/2" VENTIN WALLVV 2" SANITARYBELOW FLOORTP1/2" CW1512131415