Loading...
HomeMy WebLinkAboutA403 - Reflected CeilingDNUP DNUPDNUPDNUP DNUPDNUPA.1A.2 B.2 C.2 D.2 D.3 F.2 G.2 G.3 H.2 J.2 K.2 K.3 L.2 M.2 N.2 B.1 C.1 D.1 E.1 F.1 G.1 G.7 H.1 J.1 K.1 K.5 L.1 M.1 N.1 1 2 3 4 5 67 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 CONFERENCE ROOM 438 OFFICE 440 OFFICE 442 TRAINING ROOM 434 TRAINING ROOM 433 MULTIPURPOSE 449 PANTRY 450 VESTIBULE 403 MAIL AND SUPPLY 404 11 A701 434 434 434 434 434 434 434 434 434 434 434 434 434 434 3' - 11 5/8" 3 ' - 0 1 /2 "4 ' - 0 "6 ' - 3 1 /4 "EQEQEQEQEQEQ9' - 7 7/8" 11 A701 11 A701 1 ' - 1 1 1 /2 " 1 ' - 1 1 /4 "1 ' - 2 3 /4 " GENERAL RCP NOTES A. ALL ACCOUSTICAL CEILING TILES ARE TO MATCH EXISTING HEIGHT UNLESS NOTED OTHERWISE. ALL GYPSUM WALL BOARD CEILING TO BE AT 8'-0" UNLESS NOTED OTHERWISE B. REFER TO REFLECTED CEILING PLANS AND FINISH PLANS FOR CEILINGTYPES & HEIGHTS. C. CEILING PLANS ARE FOR FIXTURE LOCATION AND CEILING TYPE ONLY. REFER TO HVAC, ELECTRICAL, FIRE PROTECTION, AND PLUMBING FOR FURTHER INFORMATION. D. REFER TO A800 SERIES DRAWINGS FOR FINISH PLANS AND SPECIFICATIONS. E. ALL NEW LIGHT FIXTURES, EXIT SIGNS, SPRINKLER HEADS AND TERMINAL DEVICES TO BE CENTERED IN CEILING PANELS, UNLESS OTHERWISE INDICATED. F. ALL CEILING TO BE CENTERED IN ROOMS UNLESS NOTED OTHERWISE. REFLECTED CEILING PLAN LEGEND CEILING HEIGHT TAG RECESSED LOW VOLTAGE HALOGEN RECESSED FLUORESCENT CAN LIGHT FIXTURE 2'-0" X 2'-0" CEILING GRID & ACOUSTICAL PANELS. REFER TO FINISH SCHEDULE. SUSPENDED LINEAR FLUORESCENT LIGHT FIXTURE RECESSED 2'-0" X 4'-0" FLUORESCENT INDIRECT LIGHT FIXTURE RECESSED FLUORESCENT WALL WASH SUSPENDED PENDANT LIGHTING FIXTURE BATTERY OPERATED EMERGENCY MECHANICAL SUPPLY DIFFUSER MECHANICAL RETURN DIFFUSER 1'-0" 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 B A 9 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 179 Drawn Project Manager Checked Contract Drawing Date Project Number Q P N M L K J H G F E D C B A 18 19 18 19 Q P N M L K J H G F E D C B 20 21 20 21 22 22 T S R T S RRevit Template Version v16: 2018.04.02This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information it contains may be copied or used for other than the specific project for which it was prepared without the written consent of Baxter Hodell Donnelly Preston, Inc.150 FAYETTEVILLE STSUITE 820RALEIGH, NC 27601PHONE 919.683.1084RALEIGHCOLUMBUSCINCINNATI274 MARCONI BLVDSUITE 200COLUMBUS, OH 43215PHONE 614.486.1960302 WEST THIRD STREETSUITE 500CINCINNATI, OH 45202PHONE 513.271.1634www.bhdp.com6425 LIVING PLSUITE 200PITTSBURGH, PA 15206PHONE 412.450.6031PITTSBURGH715 PEACHTREE STSUITE 100ATLANTA, GA 30308PHONE 470.426.3762ATLANTAC:\Users\ncarter\Documents\HIG0220 - Hartford Indy_ncarter.rvt 12/14/2018 3:32:04 PM SG, NC MC DS 2016.05.27 HIG02.21 A403THIRD FLOOR REFLECTED CEILING PLANTHE HARTFORD GROUP - 3RD FLOOR RENOVATIONALLEN & SHARIFF ENGINEERING, LLC 1/8" = 1'-0"A403 1 THIRD FLOOR REFLECTED CEILING PLAN SHEET KEYNOTES 434 EXISTING LIGHTING FIXTURES TO BE RELOCATED AS SHOWN.No.Issue/Revision/SubmissionDate1ISSUED FOR BID AND PERMIT12/14/201812/17/2018