HomeMy WebLinkAboutA403 - Reflected CeilingDNUP
DNUPDNUPDNUP
DNUPDNUPA.1A.2
B.2
C.2
D.2
D.3
F.2
G.2
G.3
H.2
J.2
K.2
K.3
L.2
M.2
N.2
B.1
C.1
D.1
E.1
F.1
G.1
G.7
H.1
J.1
K.1
K.5
L.1
M.1
N.1
1
2
3
4
5
67
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
CONFERENCE
ROOM
438 OFFICE
440
OFFICE
442
TRAINING ROOM
434
TRAINING ROOM
433
MULTIPURPOSE
449
PANTRY
450
VESTIBULE
403
MAIL AND
SUPPLY
404
11
A701
434
434
434
434
434
434
434
434
434
434
434
434
434
434 3'
-
11 5/8"
3 ' - 0 1 /2 "4 ' - 0 "6 ' - 3 1 /4 "EQEQEQEQEQEQ9'
-
7 7/8"
11
A701
11
A701
1 ' - 1 1 1 /2 "
1 ' - 1 1 /4 "1 ' - 2 3 /4 "
GENERAL RCP NOTES
A. ALL ACCOUSTICAL CEILING TILES ARE TO MATCH EXISTING HEIGHT UNLESS NOTED OTHERWISE. ALL
GYPSUM WALL BOARD CEILING TO BE AT 8'-0" UNLESS NOTED OTHERWISE
B. REFER TO REFLECTED CEILING PLANS AND FINISH PLANS FOR CEILINGTYPES & HEIGHTS.
C. CEILING PLANS ARE FOR FIXTURE LOCATION AND CEILING TYPE ONLY. REFER TO HVAC, ELECTRICAL,
FIRE PROTECTION, AND PLUMBING FOR FURTHER INFORMATION.
D. REFER TO A800 SERIES DRAWINGS FOR FINISH PLANS AND SPECIFICATIONS.
E. ALL NEW LIGHT FIXTURES, EXIT SIGNS, SPRINKLER HEADS AND TERMINAL DEVICES TO BE CENTERED IN
CEILING PANELS, UNLESS OTHERWISE INDICATED.
F. ALL CEILING TO BE CENTERED IN ROOMS UNLESS NOTED OTHERWISE.
REFLECTED CEILING PLAN LEGEND
CEILING HEIGHT TAG
RECESSED LOW VOLTAGE HALOGEN
RECESSED FLUORESCENT CAN LIGHT FIXTURE
2'-0" X 2'-0" CEILING GRID & ACOUSTICAL PANELS.
REFER TO FINISH SCHEDULE.
SUSPENDED LINEAR FLUORESCENT LIGHT
FIXTURE
RECESSED 2'-0" X 4'-0" FLUORESCENT
INDIRECT LIGHT FIXTURE
RECESSED FLUORESCENT WALL WASH
SUSPENDED PENDANT LIGHTING FIXTURE
BATTERY OPERATED EMERGENCY
MECHANICAL SUPPLY DIFFUSER
MECHANICAL RETURN DIFFUSER
1'-0"
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17
B
A
9
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 179
Drawn
Project Manager
Checked
Contract Drawing Date
Project Number
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
18 19
18 19
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
20 21
20 21
22
22
T
S
R
T
S
RRevit Template Version v16: 2018.04.02This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information it contains may be copied or used for other than the specific project for which it was prepared without the written consent of Baxter Hodell Donnelly Preston, Inc.150 FAYETTEVILLE STSUITE 820RALEIGH, NC 27601PHONE 919.683.1084RALEIGHCOLUMBUSCINCINNATI274 MARCONI BLVDSUITE 200COLUMBUS, OH 43215PHONE 614.486.1960302 WEST THIRD STREETSUITE 500CINCINNATI, OH 45202PHONE 513.271.1634www.bhdp.com6425 LIVING PLSUITE 200PITTSBURGH, PA 15206PHONE 412.450.6031PITTSBURGH715 PEACHTREE STSUITE 100ATLANTA, GA 30308PHONE 470.426.3762ATLANTAC:\Users\ncarter\Documents\HIG0220 - Hartford Indy_ncarter.rvt 12/14/2018 3:32:04 PM
SG, NC
MC
DS
2016.05.27
HIG02.21
A403THIRD FLOOR REFLECTED CEILING PLANTHE HARTFORD GROUP - 3RD FLOOR RENOVATIONALLEN & SHARIFF ENGINEERING, LLC 1/8" = 1'-0"A403
1 THIRD FLOOR REFLECTED CEILING PLAN
SHEET KEYNOTES
434 EXISTING LIGHTING FIXTURES TO BE RELOCATED AS SHOWN.No.Issue/Revision/SubmissionDate1ISSUED FOR BID AND PERMIT12/14/201812/17/2018