Loading...
HomeMy WebLinkAboutD103 - Demo Plan22222 2 244222 22N.I.C. DNUP DNUPDNUP2 2N.I.C. DNUP DNUPDNUPA.1A.2 B.2 C.2 D.2 D.3 F.2 G.2 G.3 H.2 J.2 K.2 K.3 L.2 M.2 N.2 B.1 C.1 D.1 E.1 F.1 G.1 G.7 H.1 J.1 K.1 K.5 L.1 M.1 N.1 1 2 3 4 5 67 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 159 206 203 205 223223 223 261 261 261 261 261 261 261 261 261 261 GENERAL DEMOLITION NOTES A. REFER TO DRAWING G001 FOR GENERAL PROJECT NOTES. B. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING (MEP) DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION. C. REMOVE ALL GYPSUM, AND DEMOUNTABLE PARTITIONS SHOWN DASHED ON DEMOLITION DRAWINGS. PARTITION REMOVAL TO EXTEND FROM FLOOR TO UNDERSIDE OF STRUCTURE AND/OR CEILING ABOVE. DOORS AND FRAMES SHOWN DASHED WITHIN THE EXTENT OF DASHED PARTITIONS ARE TO BE REMOVED, INCLUDING LINTELS, HEADERS AND TRANSOMS. REFER TO ELECTRICAL, MECHANICAL AND PLUMBING DOCUMENTS FOR REMOVAL OF DEVICES WITHIN THE DASHED PARTITIONS. MAILBOXES, FURNITURE STANDARDS, SIGNS, WHITEBOARDS, DISPLAY CASES, ETC. NOT MARKED FOR SALVAGE ARE TO BE REMOVED. D. REMOVE ALL DOORS SHOWN DASHED WITHIN WALLS TO REMAIN. REMOVE ALL ASSOCIATED HARDWARE, INCLUDING THRESHOLDS. WALLS, DOORS AND FRAMES SHOWN SOLID ARE TO REMAIN. PROTECT DURING DEMOLITION. E. REFER TO MECHANICAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL DEMOLITION DRAWINGS FOR EXTENT OF DEMOLITION OF MECHANICAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL ITEMS. F. REMOVE ALL EXISTING FURNITURE AND FREE STANDING EQUIPMENT NOT DESIGNATED FOR REUSE AS DIRECTED BY OW NER / CONSTRUCTION MANAGER. FURNITURE AND FREE STANDING EQUIPMENT DESIGNATED FOR REUSE IS TO BE REMOVED AND STORED PER OWNER / CONSTRUCTION MANAGER DIRECTION. G. PROTECT EXISTING PERIMETER WALL AND WINDOW SYSTEM/CURTAINWALL FROM DAMAGE DURING DEMOLITION INCLUDING, BUT NOT LIMITED TO, GYPSUM WALLBOARD, SILL, ALUMINUM CURTAINWALL WINDOW SYSTEM, AND GYPSUM SOFFIT. H. EXISTING WINDOW BLINDS ON EXTERIOR WINDOWS TO REMAIN. PROTECT DURING DEMOLITION. REPAIR/REPLACE DAMAGED BLINDS AS DIRECTED BY OWNER. J. DEMOLITION CONTRACTOR TO VERIFY WITH OWNER AND/OR CONSTRUCTION MANAGER THOSE ITEMS THAT ARE TO BE SALVAGED PER OWNER'S INSTRUCTIONS PRIOR TO BEGINNING WORK. K. DEMOLITION CONTRACTOR TO ADVISE CONSTRUCTION MANAGER OF PARTITIONS REMAINING THAT HAVE BEEN WEAKENED AFTER DEMOLITION AND ARE UNSAFE OR UNSALVAGEABLE. L. DEMOLITION CONTRACTOR TO IDENTIFY ANY ELECTRICAL RISER OR PLUMBING RISER UNCOVERED WITHIN A DEMOLISHED PARTITION. INCLUDES, MECHANICAL DUCT SHAFTS NOT INDICATED ON DOCUMENTS. M. DEMOLITION CONTRACTOR TO SAFELY SECURE ANY AND ALL PIPING, WIRING, CABLES, OR DEVICES THAT ARE NOT SCHEDULED FOR DEMOLITION AND WHERE SECURED BY ITEMS (PARTITIONS) THAT HAVE BEEN OR ARE SCHEDULED FOR DEMOLITION. N. REMOVE EXISTING PLUMBING LINES AND DRAINS AS INDICATED ON PLUMBING DEMOLITION DRAWINGS. PATCH/REPAIR EXISTING FLOOR SLAB WITHIN PROJECT AREA. P. NO STRUCTURAL ELEMENTS (COLUMNS, BEAMS, GIRDERS, JOISTS, SLAB) ARE TO BE REMOVED OR ALTERED DURING DEMOLITION. Q. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR PATCHING ANY SURFACES OR OPENINGS DAMAGED OR LEFT FROM DEMOLITION OF MEP ITEMS. PATCH AREAS TO MATCH SURROUNDING CONSTRUCTION. REFER TO MEP DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION. R. REMOVE ALL WALL/BASE CABINETS AND STORAGE EQUIPMENT SHOWN DASHED UNLESS NOTED OTHERWISE. REMOVAL INCLUDES COUNTERTOPS, SUPPORTS, BACKSPLASHES, TABLES, WALL MOUNTED SHELVES AND STANDARDS, SINKS AND ALL ASSOCIATED PIPING. REFER TO MEP DEMOLITION DRAWINGS FOR CAPPING AND EXTENT OF REMOVAL. S. ALL EXISTING INTERIOR ROOF DRAIN LEADERS TO REMAIN. PROTECT DURING DEMOLITION. PATCH AND REPAIR AS REQUIRED. CONTRACTOR TO VERIFY LOCATION OF ROOF LEADERS PRIOR TO DEMOLITION. T. PATCH ALL REMAINING SURFACES AFTER PARTITIONS ARE DEMOLISHED TO MATCH SURROUNDING SURFACES. PRPEARE TO RECEIVE NEW FINISHES. U. ALL CONCRETE TO BE DEMOLISHED SHALL BE SAWCUT SO TO LEAVE A SMOOTH SURFACE ON THE STRUCTURE TO REMAIN. V. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL STRUCTURE, WALLS, DOORS, FRAMES, MEP ITEMS, ETC. THAT ARE REQUIRED TO REMAIN. W. ALL EXISTING FLOORING (CARPET, CARPET PAD, VCT, TILE, ETC.) AND WALL BASE (RUBBER, TILE, ETC.) IS TO BE REMOVED AS NOTED. SCRAPE FINISH FLOOR CLEAN OF ADHESIVES, FASTENERS, OR ANYIMPEDIMENTS TO THE INSTALLATION OF NEW FLOOR COVERING AND BASE. X. ALL EXISTING CEILING TILE AND SUSPENSION SYSTEM SHOWN DASHED TO BE REMOVED UNLESS OTHERWISE DESIGNATED. REMOVE EXISTING LIGHTS, DIFFUSERS, MEP DEVICES, SHOWN DASHED. SALVAGE FOR REUSE AS DIRECTED, REFER TO MEP DRAWRINGS. Y. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR THE REMOVAL OF LIGHTS, DIFFUSERS, MEP DEVICES. SALVAGE FOR REUSE AS DIRECTED. Z. ALL TEMPORARY SECURITY DEVICES AND DETAILS TO BE COORDINATED WITH OWNERS SECURITY AND ARCHITECT. AA. LABEL ALL EXISTING CONDUIT TO REMAIN IN CEILING. REFER TO MEP. BB. NO DEMO AT EXISTING COLUMN WRAPS, UNO. 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 B A 9 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 179 Drawn Project Manager Checked Contract Drawing Date Project Number Q P N M L K J H G F E D C B A 18 19 18 19 Q P N M L K J H G F E D C B 20 21 20 21 22 22 T S R T S RRevit Template Version v16: 2018.04.02This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information it contains may be copied or used for other than the specific project for which it was prepared without the written consent of Baxter Hodell Donnelly Preston, Inc.150 FAYETTEVILLE STSUITE 820RALEIGH, NC 27601PHONE 919.683.1084RALEIGHCOLUMBUSCINCINNATI274 MARCONI BLVDSUITE 200COLUMBUS, OH 43215PHONE 614.486.1960302 WEST THIRD STREETSUITE 500CINCINNATI, OH 45202PHONE 513.271.1634www.bhdp.com6425 LIVING PLSUITE 200PITTSBURGH, PA 15206PHONE 412.450.6031PITTSBURGH715 PEACHTREE STSUITE 100ATLANTA, GA 30308PHONE 470.426.3762ATLANTAC:\Users\ncarter\Documents\HIG0220 - Hartford Indy_ncarter.rvt 12/14/2018 3:32:19 PM SG, NC MC DS 2016.05.27 HIG02.21 D103THIRD FLOOR - DEMOLITION PLANTHE HARTFORD GROUP - 3RD FLOOR RENOVATIONALLEN & SHARIFF ENGINEERING, LLC 1/8" = 1'-0"D103 1 LEVEL 3 - DEMOLITION FLOOR PLAN SHEET KEYNOTES 159 HATCHED AREA INDICATES NEW TENNANT DEMISING AND COMMON CORRIDOR. NEW TENNANT DEMISING WALL AND COMMON CORRIDOR TO BE CONSTRUCTED BY LANDLORD. 203 REMOVE OPERABLE PARTITION IN ITS ENTIRETY. 205 REMOVE EXISTING FURNITURE, STORE PER OWNERS DIRECTION. 206 REMOVE EXISTING FLOOR FINISH FROM EXISTING SLAB TO REMAIN, INCLUDING ALL WALL BASE AND ALL ADHESIVES. PREPARE SLAB TO RECIEVE NEW FINISHES, REFER TO FINISH PLANS. 223 SALVAGE EXISTING FRAME AND GLASS FOR REUSE. REFER TO NEW WORK PLANS FOR LOCATION. 261 SALVAGE DOOR, FRAME AND HARDWARE FOR REUSE. REFER TO NEW WORK PLAN FOR MORE INFORMATION. REFER TO NEW WORK DOOR SCHEDULE FOR HARDWARE AND VERIFY EXISTING HARDWARE WILL MATCH.No.Issue/Revision/SubmissionDate1 ISSUED FOR BID AND PERMIT12/14/201812/17/2018