HomeMy WebLinkAboutE001 - Electrical Data123456781011121314151617BA91234567810111213141516179DrawnProject ManagerCheckedContract Drawing DateProject NumberQPNMLKJHGFEDCBA18191819QPNMLKJHGFEDCB202120212222TSRTSRRevit Template Versionv16: 2017.10.05This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information itcontains may be copied or used for other than the specific project for which it was prepared without the written consent of BaxterHodell Donnelly Preston, Inc. CINCINNATI COLUMBUS RALEIGH PITTSBURGH ATLANTA LAWRENCE DIGENNARO, ARCHITECT 302 WEST THIRD STREET SUITE 500 CINCINNATI, OHIO 45202 PHONE 513.271.1634HIG02.21THE HARTFORD GROUP - 3RD FLOOR RENOVATION 501 PENNSYLVANIA PKWY #400 INDIANAPOLIS, IN 46280 No.Issue/Revision/Submission Date 1 ISSUED FOR BID AND PERMIT 12/14/20182016.05.27E001ELECTRICAL DATA SHEETJRHJRHDEB GENERAL ELECTRICAL NOTES:GENERAL: UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL WORK SHOWN ON THE ELECTRICAL DRAWINGS ISNEW WORK TO BE PROVIDED UNDER THIS CONTRACT.DEMOLITION: SEE "ELECTRICAL GENERAL DEMOLITION NOTES" SHEET E.XX FOR ADDITIONAL DEMOLITIONREQUIREMENTS.COORDINATION: COORDINATE AND COOPERATE WITH ALL TRADES ON THE PROJECT.RECORD DRAWINGS: SECURE AN EXTRA SET OF ELECTRICAL DRAWINGS TO BE KEPT ON SITE AND MARK, DAILY, THEDRAWINGS IN RED AS THE PROJECT PROGRESSES IN ORDER TO KEEP AN ACCURATE RECORD OF ALL DEVIATIONSBETWEEN THE WORK SHOWN ON THE DRAWINGS AND THE WORK WHICH IS ACTUALLY INSTALLED. THESE MARKEDDRAWINGS SHALL REFLECT ANY AND ALL CHANGES AND REVISIONS TO THE ORIGINAL DESIGN WHICH EXISTS INTHE COMPLETED WORK. DELIVER THE MARKED DRAWINGS TO THE <ARCHITECT/ENGINEER> AT PROJECT CLOSE-OUT.TESTS: TEST ALL WIRING FOR CONTINUITY AND GROUNDS BEFORE CONNECTING ANY FIXTURES OR DEVICES.PERFORM INSULATION RESISTANCE TESTS ON ALL WIRING #8 OR LARGER TO ENSURE THAT ALL PORTIONS ARE FREEFROM SHORT-CIRCUITS AND GROUNDS.INSPECTIONS: ARRANGE ALL NECESSARY INSPECTIONS. DELIVER ALL REQUIRED INSPECTION CERTIFICATES TO THEOWNER.GROUNDING: PROVIDE GROUNDING IN ACCORDANCE WITH THE NEC FOR THE ELECTRICAL SYSTEM INCLUDINGEQUIPMENT FRAMES CONDUITS, SWITCHES, CONTROLLERS, WIRE-WAYS, NEUTRAL CONDUCTORS, AND OTHEREQUIPMENT. PROVIDE A GROUNDING CONDUCTOR IN ALL POWER CIRCUITS.LABELS: PROVIDE LABELS FOR ALL PANELBOARDS, CABINETS, SAFETY SWITCHES, MOTOR-DISCONNECT SWITCHES,AND MOTOR CONTROLLERS. LABELS SHALL BE MACHINE ENGRAVED, LAMINATED PLASTIC, PERMANENTLYATTACHED WITH SELF-TAPPING SCREWS OR RIVETS. DO NOT USE SELF-ADHESIVE LABELS.J-BOX LABELING: LABEL ALL JUNCTION BOXES WITH PERMANENT MARKER IDENTIFYING CIRCUIT NUMBER ANDPANELBOARD OF CIRCUITS WITHIN.PANEL DIRECTORY: PROVIDE TYPEWRITTEN PANELBOARD DIRECTORY CARD IN EACH PANELBOARD INCLUDINGEXISTING PANELBOARDS MODIFIED FOR THIS PROJECT WITH CIRCUIT LOAD INFORMATION AND ROOM NUMBERCLEARLY IDENTIFIED. USE ACTUAL ROOM NUMBERS IN THE BUILDING, NOT THE ROOM NUMBERS SHOWN ON THECONTRACT DRAWINGS, AS THEY ARE OFTEN DIFFERENT.MOTOR COORDINATION: MOTORS, MOTOR STARTERS, CONTROLLERS, INTEGRAL DISCONNECT SWITCHES, ANDCONTACTORS SHALL BE PROVIDED WITH THEIR RESPECTIVE PIECES OF EQUIPMENT BY THE EQUIPMENT SUPPLIER.COMMUNICATE WITH THE TRADES PROVIDING THE EQUIPMENT, VERIFYING ALL REQUIREMENTS, PROVIDE ALLELECTRICAL CONNECTIONS REQUIRED THEREIN, AND INSTALL MOTOR STARTERS.MOTOR DISCONNECTS: ALL MOTORS SHALL HAVE DISCONNECTING MEANS.MOTOR FUSE PROTECTION: WHERE FUSE PROTECTION IS SPECIFICALLY REQUIRED BY THE EQUIPMENTMANUFACTURER, PROVIDE FUSE SWITCHES IN LIEU OF NON-FUSE SWITCHES OR IN LIEU OF ENCLOSED CIRCUITBREAKERS, OR OTHER DEVICES INDICATED.CONNECTION DETAILS: SECURE APPROVED SHOP DRAWINGS SHOWING WIRING DIAGRAMS, ROUGH-IN AND HOOK UPDETAILS FROM OTHER INVOLVED CONTRACTORS FOR EQUIPMENT WHICH MUST BE CONNECTED ELECTRICALLY.EQUIPMENT DETAILS: MECHANICAL EQUIPMENT WILL BE FURNISHED AND INSTALLED BY THE MECHANICALCONTRACTOR. THE LOCATIONS SHOWN ON THE ELECTRICAL DRAWINGS ARE APPROXIMATE. COORDINATE WITH THEMECHANICAL CONTRACTOR TO DETERMINE THE EXACT LOCATION OF EACH PIECE OF EQUIPMENT AND DETERMINETHE EXACT ROUGH-IN AND CONNECTION REQUIREMENTS.STARTER MOUNTING: WHERE AN INDIVIDUALLY MOUNTED SAFETY SWITCH, STARTER OR CIRCUIT BREAKER IS SHOWNADJACENT TO ITS RESPECTIVE LOAD AND NOT MOUNTED ON A WALL, PROVIDE ALL SUPPORTS, BRACKETS,ANCHORING, ETC. NECESSARY TO PROPERLY SUPPORT THE DEVICE.LIGHTING ARRANGEMENT: ARRANGE LIGHTING FIXTURES IN ACCORDANCE WITH THE ARCHITECTURAL REFLECTEDCEILING PLANS.LIGHTING COORDINATION: COORDINATE LIGHTING FIXTURES WITH GRILLES, DIFFUSERS, SPRINKLER HEADS, ANDACCESS PANELS, ETC.MATERIAL COORDINATION: VERIFY CEILING AND WALL CONSTRUCTION AND MATERIAL PRIOR TO ORDERING LIGHTFIXTURES OR OTHER DEVICES TO ENSURE PROPER FIXTURES OR DEVICE IS FURNISHED TO MATCH CONSTRUCTION.MOUNTING HEIGHTS: MOUNTING HEIGHTS INDICATED ARE FROM THE FINISHED FLOOR TO THE CENTERLINE OF THEWIRING DEVICE UNLESS OTHERWISE NOTED. MOUNTING HEIGHTS OF LIGHTING FIXTURES AND FIRE ALARM DEVICESARE TO THE BOTTOM OF THE FIXTURE OR DEVICE UNLESS OTHERWISE NOTED.DEVICE LOCATIONS: COORDINATE LOCATIONS OF SWITCHES, RECEPTACLES, AND TELE/DATA OUTLETS WITH OTHERWALL MOUNTED DEVICES SUCH AS THERMOSTATS AND CONTROL STATIONS. DO NOT MOUNT WIRING DEVICESBACK TO BACK. PROVIDE MINIMUM OF ONE STUD SEPARATION.EWC RECEPTACLES: RECEPTACLES FOR ELECTRIC WATER COOLERS (EWC) SHALL BE INSTALLED OUT OF VIEW ANDBEHIND THE EWC ENCLOSURE. VERIFY THE MOUNTING HEIGHT WITH THE EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN.DEVICE COORDINATION: THOROUGHLY REVIEW AND COORDINATE ALL CASEWORK, DOOR SWINGS, AND CABINETDRAWINGS AND ARCHITECTURAL ELEVATIONS WITH DEVICE LOCATIONS PRIOR TO ROUGH-IN OF OUTLET BOXES.BARRIERS: WHERE A MULTIPLE GANG BOX HAS CIRCUITS OF DIFFERENT VOLTAGES OR SYSTEMS WHICH AREREQUIRED TO BE SEPARATED, PROVIDE THE CODE-REQUIRED SEPARATION USING A FULL HEIGHT AND DEPTHBARRIER PLATE.FIRE PROOFING: FOR ANY WALL OR FLOOR PENETRATIONS THROUGH FIRE RATED STRUCTURES PROVIDEFIRE-PROOFING TO SEAL ALL THE PENETRATIONS AFTER THE CONDUIT HAS BEEN INSTALLED. FIRE PROOFING FORPENETRATIONS SHALL BE UL APPROVED PER THE PENETRATION MADE IN ORDER TO MAINTAIN FIRE RATED INTEGRITYOF THE STRUCTURE.CLEAN UP: ON PROJECT CLOSE-OUT, CLEAN ALL ELECTRICAL DEVICES, LIGHTING FIXTURES, LAMPS AND LENSES,AND REMOVE ALL PAINT SPATTERS FROM DEVICES, FIXTURES, AND PLATES. REPLACE ALL INOPERATIVE LAMPS.OWNER FURNISHED EQUIPMENT: CONTRACTOR SHALL OBTAIN CUT SHEETS, INSTALLATION DATA, AND ROUGH-INREQUIREMENTS FOR OWNER FURNISHED, CONTRACTOR INSTALLED EQUIPMENT AND COORDINATE ROUGH-IN ANDPOWER REQUIREMENTS WITH THE OWNER'S REPRESENTATIVE PRIOR TO STARTING ANY ASSOCIATED WORK.CONDUIT ROUTING: ALL CONDUIT RUN OVERHEAD SHALL BE RUN AT THE BOTTOM OF THE FLOOR, ROOF STRUCTURE,OR LOWEST CHORD OF JOIST SPACE (AS APPLICABLE) ABOVE IN ORDER TO AVOID CONFLICTS WITH OTHER TRADES.WIRING DEVICES: ALL RECEPTACLES AND SWITCHES SHALL BE LABELED WITH PLASTIC LAMINATED LABEL WITH THEPANELBOARD DESIGNATION AND CIRCUIT NUMBER FROM WHICH IT IS FED.EQUIPMENT DEMONSTRATION: PROVIDE A DEMONSTRATION OF THE OPERATION OF ALL ELECTRICAL COMPONENTSUPON REQUEST OF THE OWNER.CEILING PLENUM: ALL WIRING THAT WILL NOT BE RUN IN CONDUIT SHALL BE PLENUM RATED.ELECTRICAL GENERAL DEMOLITION NOTES:GENERAL: DEMOLITION DRAWINGS ARE BASED ON EXISTING PLANS AND FIELDINVESTIGATION PRIOR TO DEMOLITION. VISIT THE EXISTING BUILDING PRIOR TO BID INORDER TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND IN ORDER TOAVOID CONFLICTS.DASHED ITEMS: ALL ITEMS SHOWN DASHED ON DEMOLITION PLANS ARE EXISTINGAND SHALL BE REMOVED COMPLETE INCLUDING BOXES, CONDUIT, WIRE, FASTENERS,AND ASSOCIATED APPURTENANCES UON.SOLID ITEMS: ALL ITEMS SHOWN SOLID ON DEMOLITION PLANS ARE EXISTING TOREMAIN.CIRCUITING TO REMAIN: EXISTING CIRCUITING TO REMAIN SHALL BE REROUTED ORRECONNECTED, AS REQUIRED, WHERE AFFECTED BY NEW WORK IN ORDER TOMAINTAIN CONTINUITY OF CIRCUIT.REUSE OF EXISTING CIRCUITRY: EXISTING CIRCUITRY SERVING LIGHTING FIXTURESAND/OR RECEPTACLES FOR A GIVEN AREA SHALL BE REUSED WHERE CONVENIENT TOSERVE THE NEW LAYOUT. PROVIDE CIRCUIT MODIFICATIONS INDICATED OR ASOTHERWISE REQUIRED TO MAINTAIN THE CONTINUITY OF THE EXISTING CIRCUITS THATREMAIN.EXISTING CONDUIT: ALL EXISTING CONDUITS AND WIRING THAT WILL NOT BE REUSEDSHALL BE REMOVED WHERE THEY WILL BE EXPOSED UPON COMPLETION OF NEWWORK. EXISTING CONDUIT TO REMAIN CONCEALED IN WALLS SHALL BE ABANDONED.EXISTING CONDUIT TO REMAIN BELOW FLOOR SLAB SHALL BE CUT OFF ONE INCHBELOW ROUGH FLOOR AND GROUTED FLUSH. ALL EXISTING WIRING IN CONDUITS TOBE ABANDONED SHALL BE DISCONNECTED FROM POWER SOURCE AND REMOVED.REPAIR DAMAGE: EXERCISE CARE IN REMOVAL OF DEMOLITION ITEMS. REPAIR, AT NOADDITIONAL COST TO OWNER, ANY DAMAGE CAUSED TO EXISTING CONSTRUCTIONAND/OR EQUIPMENT TO REMAIN.ASSOCIATED APPURTENANCES: REMOVE ALL ELECTRICAL APPURTENANCES(DISCONNECTS, STARTERS, WIRING, CONDUIT, ETC.) ASSOCIATED WITH EQUIPMENT TOBE REMOVED BY OTHERS.KNOCKOUT PLUGS AND COVERS: ALL CONDUIT REMOVED SHALL BE REMOVED IN ITSENTIRETY, INCLUDING FITTINGS, MOUNTING DEVICES, MOUNTING HARDWARE, ETC.PROVIDE CONDUIT PLUGS AND BLANKS FOR ALL OPENINGS CREATED BY THEREMOVAL OF CONDUIT. PROVIDE BLANK COVER PLATES FOR ALL OPENED OUTLETBOXES CREATED BY THE REMOVAL OF THE EQUIPMENT AND/OR DEVICES.DEMOLISHED MATERIALS: ALL MATERIALS REMOVED UNDER DEMOLITION, NOT TO BERELOCATED OR DESIGNATED TO BE TURNED OVER TO THE OWNER, SHALL BECOMEPROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED COMPLETELY FROM THESITE.SCHEDULE OUTAGES: ALL WORK AND ALL POWER OUTAGES IN THE EXISTINGBUILDING SHALL BE SCHEDULES AT TIMES CONVENIENT TO THE OWNER.NOTIFICATION: NOTIFY THE OWNER PRIOR TO TURNING OFF ANY CIRCUITS.EXISTING CIRCUITS: IF DURING THE COURSE OF CONSTRUCTION, IT IS DETERMINED BYTHE CONTRACTOR THAT AN EXISTING CIRCUIT BECOMES SPARE, THE CONTRACTORSHALL UPDATE THE PANELBOARD DIRECTORY TO INDICATE SUCH, EVEN IF IT IS NOTEXPLICITLY MARKED ON THE ELECTRICAL PLANS.ELECTRICAL PANELBOARDJUNCTION BOX - ABOVE CEILINGS OR FLUSH IN WALLS. POWERQUADRUPLEX RECEPTACLES IN COMMON BOX, 20A, 120V, 18"AFF, UON.DUPLEX RECEPTACLE, GROUND FAULT INTERRUPTING TYPE, 20A,120V, 40"AFF OR 4" ABOVE COUNTER TOP OR BACKSPLASH(WHICHEVER IS HIGHER), OR IN CASEWORK, AS APPLICABLE, UON.COMMUNICATIONSTELE/DATA BOX, 4"X4"X2 1/4"D BOX WITH SINGLE GANG PLASTERRING 18"AFF, UON, WITH 1 1/4"C WITH PULL STRING STUBBEDABOVE ACCESSIBLE CEILING AND TERMINATED WITH PLASTICBUSHING.FIRE ALARMFIRE ALARM VISUAL (STROBE) APPLIANCE, MOUNT 80"AFF, OR 6"BELOW FINISHED CEILING, WHICHEVER IS LOWER, UON.SUBSCRIPT INDICATES MINIMUM CANDELA RATING.FIRE ALARM MANUAL PULL STATION, 44"AFF TO ACTUATING ARM,UON.ADDRESSABLE FIRE ALARM SYSTEM PHOTO-ELECTRIC SMOKEDETECTOR, CEILING MOUNTED.FIRE ALARM CONTROL PANEL, SURFACE MOUNTED, TOP 5'-9" AFF.POWER POLE. PROVIDED BY OTHERS.LIGHTINGLIGHTING FIXTURE.LP-B-3aA1. LETTER "A" DENOTES FIXTURE TYPE. REFER TO LIGHTING FIXTURESCHEDULE THIS SHEET.2. SUBSCRIPT "LP-B" INDICATES NAME OF PANELBOARD FROMWHICH FIXTURE IS FED. ASSOCIATED NUMBER "3" INDICATESCIRCUIT NUMBER IN PANELBOARD FROM WHICH FIXTURE IS FED.ASSOCIATED LETTER "a", WHERE USED, INDICATES LIGHTINGFIXTURE CONTROL DEVICE DESIGNATION.LIGHTING FIXTURE KEYDOWNLIGHT FIXTURE.EXIT LIGHTING FIXTURE WITH DIRECTIONAL ARROWS AS INDICATEDON DRAWINGS. CONNECT TO DEDICATED EMERGENCY BRANCHCIRCUIT. SHADED AREA DENOTES LIGHTED FACE.ELECTRICAL CIRCUIT RUN IN CONDUIT AND CIRCUIT HOMERUN TOPANELBOARD (PANEL AND CIRCUIT DESIGNATION AS INDICATED).AS A MINIMUM CONDITION, EACH SINGLE PHASE CIRCUIT SHALLHAVE 1 #12 PHASE CONDUCTOR, 1 #12 NEUTRAL CONDUCTOR, AND 1#12 GROUNDING CONDUCTOR IN 3/4" CONDUIT. PROVIDEADDITIONAL PHASE CONDUCTORS AS REQUIRED FOR "MULTIPLEPHASED" ELECTRICAL LOADS. PROVIDE ADDITIONAL "SWITCH LEG"CONDUCTORS TO PROVIDE THE LIGHT FIXTURE CONTROLINDICATED. MULTIPLE SINGLE PHASE CONDUCTORS SHALL BEGROUPED TOGETHER IN A COMMON CONDUIT IN ACCORDANCEWITH THE NEC AND AT THE CONTRACTOR'S DISCRETION. NEUTRALAND GROUNDING CONDUCTORS SHALL NOT BE SHARED. CONDUITLARGER THAN 3/4" AND CONDUCTORS LARGER THAN #12 SHALLBE AS INDICATED.SOSDUAL TECHNOLOGY OCCUPANCY SENSOR, CEILING MOUNTED. "#"DENOTES OCCUPANCY SENSOR TYPE. SUBSCRIPT "a", WHEREUSED, INDICATES ASSOCIATED FIXTURES TO BE CONTROLLED.OS1: SENSOR SWITCH CM-PDT-9 OR EQUALOS2: SENSOR SWITCH CM-PDT-10 OR EQUALWALL SWITCH OCCUPANCY SENSOR, 44" AFF UON. REFER TOOCCUPANCY SENSOR SCHEDULE SHEET EX.X FOR DETAILS.GENERALKEYNOTE.SaSINGLE POLE SWITCH, 20A, 120/277V, 44"AFF UON. SUBSCRIPT "a"INDICATES ASSOCIATED FIXTURES TO BE CONTROLLED.SDaDIMMER SWITCH, 44" AFF UON. PROVIDE LUTRON "NOVA" SERIESSWITCH (OR APPROVED EQUAL) COMPATIBLE WITH DIMMINGBALLAST. SUBSCRIPT "a", WHERE USED, INDICATES ASSOCIATEDFIXTURES TO BE CONTROLLED.S3aTHREE-WAY SWITCH, 20A, 120/277V, 44"AFF UON. SUBSCRIPT "a"INDICATES ASSOCIATED FIXTURES TO BE CONTROLLED.DUPLEX RECEPTACLE, 20A, 120V, 40"AFF OR 4" ABOVE COUNTERTOP OR IN CASEWORK (AS APPLICABLE), OR IN CASEWORK, ASAPPLICABLE, UON.DRY-TYPE TRANSFORMERFUSE SIZE (AMPS), N.F. INDICATES NON-FUSEDDISCONNECT SWITCH - SIZE AS INDICATED ON PLANSSIZE (AMPS)30/2/20/3RNo. OF POLESNEMA RATING (IF OTHER THAN 1)EMERGENCY BATTERY LIGHTING UNIT, CONNECT AHEAD OF LOCALSWITCH.DUPLEX RECEPTACLE, 20A, 120V, 18"AFF, UON.SPECIAL RECEPTACLE. NEMA CONFIGURATION AS NOTED. MOUNT18"AFF UON.CABLE TELEVISION OUTLET, PROVIDE DUPLEX 4"X4"X2 1/4"D BOXWITH SINGLE GANG PLASTER RING, WITH 1 1/4"C WITH PULL STRINGSTUBBED ABOVE ACCESSIBLE CEILING AND TERMINATED WITHBUSHING. MOUNT 18"AFF UON.FIRE ALARM AUDIO/VISUAL (HORN/STROBE) APPLIANCE, 80"AFF,OR 6" BELOW FINISHED CEILING, WHICHEVER IS LOWER, UON.SUBSCRIPT INDICATES MINIMUM CANDELA RATING.15FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT EXTENDER PANEL,SURFACE MOUNTED, TOP, 5'-9" AFF.PENDANT LIGHTING FIXTURE.SLV1aLOW VOLTAGE SWITCH, 44" AFF UON. SUBSCRIPT "1" INDICATESLOW VOLTAGE SWITCH DESIGNATION. SUBSCRIPT "a" INDICATESLOW VOLTAGE BUTTON DESIGNATION. REFER TO LIGHTING RELAYPANEL SCHEDULES FOR TOTAL NUMBER OF BUTTONS PER SWITCHAND ADDITIONAL INFORMATION.ABOVE FINISHED FLOORAFFABBREVIATIONSAMPEREAABOVE FINISHED GRADEAFGAIR HANDLING UNITAHUAICAMPERE INTERRUPTING CURRENTATSAUTOMATIC TRANSFER SWITCHAVAUDIO/VISUALBFGBELOW FINISHED GRADECCONDUITCATVCABLE ANTENNA TELEVISIONCFLCOMPACT FLUORESCENTCKTCIRCUITEBUEMERGENCY BATTERY UNITECEMPTY CONDUITECBENCLOSED CIRCUIT BREAKEREFEXHAUST FANERUENERGY RECOVERY UNITEQUIPEQUIPMENTETREXISTING TO REMAINEWCELECTRIC WATER COOLEREWHELECTRIC WATER HEATEREXISTEXISTINGFHPFRACTIONAL HORSE POWERFLAFULL LOAD AMPSFPVAVFAN POWERED VARIABLE AIR VOLUMEGCGENERAL CONTRACTORGFCIGROUND FAULT CIRCUIT INTERRUPTERGNDGROUNDHIDHIGH INTENSITY DISCHARGEKVAKILO-VOLT AMPEREKWKILO-WATTLCLIGHTING CONTACTORLTGLIGHTINGMAUMAKE UP AIR UNITMCAMINIMUM CIRCUIT AMPSMCMECHANICAL CONTACTORMCMETAL CLADMCBMAIN CIRCUIT BREAKERMFRMANUFACTURERMLOMAIN LUGS ONLYMTDMOUNTEDNECNATIONAL ELECTRICAL CODENFNON-FUSEDNICNOT IN CONTRACTNLNIGHT LIGHTNTSNOT TO SCALEOCON CENTEROFCIOWNER FURNISHEDCONTRACTOR INSTALLEDPPOLEPCPPUMP CONTROL PANELPFPOWER FACTORPLPROPERTY LINEPNLPANELPNLBDPANELBOARDØPHASEPRIPRIMARYRECPRTUROOF TOP UNITSESERVICE ENTRANCESECSECONDARYTBBTELEPHONE BACKBOARDTRTTRIPLE TUBE FLUORESCENT LAMPTVSSTRANSIENT VOLTAGETYPTYPICALUONUNLESS OTHERWISE NOTEDVVOLTSVACVOLTS ALTERNATING CURRENTVAVVARIABLE AIR VOLUMEVDCVOLTS DIRECT CURRENTCCTVCLOSED CIRCUIT TELEVISIONCBCIRCUIT BREAKERECELECTRICAL CONTRACTORHPHORSE POWER/HEAT PUMPHVACHEATING, VENTILATING,IGISOLATED GROUNDJBJUNCTION BOXPCPLUMBING CONTRACTORAND AIR CONDITIONINGVFDVARIABLE FREQUENCY DRIVEWWATTS/WIREWGWIRE GUARDWPWEATHERPROOFXFMRTRANSFORMERSURGE SUPPRESSERFPCFIRE PROTECTION CONTRACTORTRTAMPER RESISTANTRECEPTACLEOS#JPPACACTVVAVFACPSDFNAC151GENERAL SPECIAL SYSTEM NOTES:FIRE ALARM SYSTEMALL FIRE ALARM NOTIFICATION DEVICES SHALL MEET THE REQUIREMENTS OF THEAMERICANS WITH DISABILITIES ACT (ADA) AND NFPA 72.ALL WIRING SHALL BE RUN IN CONDUIT (3/4" MINIMUM). MAKE ALL WIRECONNECTIONS TO DEVICES PER MANUFACTURER'S RECOMMENDATION AND NFPA 72.MANUFACTURER, IN CONJUNCTION WITH THE CONTRACTOR, SHALL DETERMINECONDUIT AND WIRING REQUIREMENTS AND DOCUMENT ALL ADDITIONS ANDCHANGES ON AS-BUILT RECORD DRAWINGS.THE EXISTING FIRE ALARM SYSTEM IS MANUFACTURED BY HONEYWELL FIRE-LITE.ALL MATERIALS AND DEVICES SHALL BE COMPATIBLE WITH THE EXISTING SYSTEM.FIRE ALARM VISUAL (STROBE) APPLIANCE, CEILING MOUNTED.SUBSCRIPT INDICATES MINIMUM CANDELA RATING.FIRE ALARM AUDIO/VISUAL (HORN/STROBE) APPLIANCE, CEILINGMOUNTED. SUBSCRIPT INDICATES MINIMUM CANDELA RATING.15VAV15WWPT1RECESSED MULTI-SERVICE POKE-THRU. PROVIDE WIREMOLD4ATC2Rxx-4CTCxx WITH (1) DUPLEX RECEPTACLES AND(1)TELE/DATA MOUNTING PLATE. PROVIDE (1) 3/4"C FOR 120VPOWER AND 1-1/2"C WITH PULL WIRE FOR TELE/DATA CABLINGSTUBBED TO ABOVE ACCESSIBLE CEILING WITH PROTECTIVEBUSHING. EXISTING FLOOR WILL NEED TO BE CORE DRILLED FORNEW POKE-THRU. COORDINATE CORE DRILL LOCATION WITHARCHITECT/FURNITURE VENDOR PRIOR TO DRILLING.PT2RECESSED MULTI-SERVICE POKE-THRU. PROVIDE WIREMOLD6ATC2Pxx-6CT2xx WITH (2) DUPLEX RECEPTACLES AND TELE/DATAMOUNTING PLATE. PROVIDE (1) 3/4"C FOR 120V POWER AND 1-1/2"CWITH PULL WIRE FOR TELE/DATA CABLING STUBBED TO ABOVEACCESSIBLE CEILING WITH PROTECTIVE BUSHING. EXISTING FLOORWILL NEED TO BE CORE DRILLED FOR NEW POKE-THRU.COORDINATE CORE DRILL LOCATION WITH ARCHITECT/FURNITUREVENDOR PRIOR TO DRILLING.