HomeMy WebLinkAboutE501 - Electrical Details123456781011121314151617BA91234567810111213141516179DrawnProject ManagerCheckedContract Drawing DateProject NumberQPNMLKJHGFEDCBA18191819QPNMLKJHGFEDCB202120212222TSRTSRRevit Template Versionv16: 2017.10.05This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information itcontains may be copied or used for other than the specific project for which it was prepared without the written consent of BaxterHodell Donnelly Preston, Inc.
CINCINNATI
COLUMBUS
RALEIGH
PITTSBURGH
ATLANTA
LAWRENCE DIGENNARO, ARCHITECT
302 WEST THIRD STREET
SUITE 500
CINCINNATI, OHIO 45202
PHONE 513.271.1634HIG02.21THE HARTFORD GROUP - 3RD FLOOR RENOVATION
501 PENNSYLVANIA PKWY #400
INDIANAPOLIS, IN 46280
No.Issue/Revision/Submission Date
1 ISSUED FOR BID AND PERMIT 12/14/20182016.05.27E501ELECTRICAL DETAILSJRHJRHDEB 1E501PARTIAL FIRE ALARM RISER DIAGRAMNO SCALENOTES;1. REFER TO FLOOR PLAN FOR QUANTITY AND LOCATION OF SYSTEM COMPONENTS. EXACT ARRANGEMENT AND QUANTITY OF DEVICES SHALLBE INDICATED ON THE SHOP DRAWINGS. PROVIDE COMPLETE RISER DIAGRAM AS PART OF SHOP DRAWINGS.2. VERIFY ALL WIRING AND SIZES WITH THE FIRE ALARM SYSTEM MANUFACTURER AND INSTALL AS DIRECTED.3. CANDELA RATING SHALL BE PER NFPA 72 REQUIREMENTS.4. ALL FIRE ALARM WIRING SHALL BE ROUTED VIA A SEPARATE 3/4"C (MINIMUM) CONDUIT SYSTEM. FIRE RATED MC CABLE IS ACCEPTABLE.5. DO NOT LOAD ANY CIRCUIT BEYOND 80% OF RATED CAPACITY. SUBMIT CALCULATIONS TO SUBSTANTIATE. ADD ADDITIONAL CIRCUITS ASNECESSARY.6. PROVIDE CONDUIT SLEEVES WITH ESCUTCHEON PLATES WHERE PASSING THROUGH WALLS, FLOOR, OR CEILINGS.7. ALL VISUAL AND AUDIO DEVICES SHALL BE SYNCHRONIZED.8. THIS CONTRACTOR SHALL PROVIDE ALL ADDITIONAL POWER SUPPLIES, BATTERIES, EXTENDER PANELS, ETC. AS REQUIRED FOR A COMPLETEAND OPERATIONAL SYSTEM.9. PROVIDE REMOTE TEST SWITCHES AND ASSOCIATED CONTROL MODULES FOR ALL FIRE SMOKE AND SMOKE DAMPERS. COORDINATE EXACTLOCATION OF ALL TEST SWITCHES WITH OWNER PRIOR TO ROUGH-IN. THESE SHALL BE LOCATED IN UTILITY/BACK-OF-HOUSE SPACES.10. PROVIDE CONTROL MODULES TO INTERFACE WITH ALL ACCESS CONTROLLED DOORS AS REQUIRED BY CODE. CONTROL MODULES SHALLFUNCTION TO SIGNAL DOORS TO FAIL SAFE UPON ACTIVATION OF FIRE ALARM. NOTE THAT MODULES ARE NOT SHOWN ON FLOOR PLAN, BUTSHALL BE PROVIDED AS NOTED.11. THIS CONTRACTOR SHALL PROVIDE BATTERY CALCULATIONS, WIRING DIAGRAMS, EQUIPMENT CUTS, ETC. AS PART OF THE SHOP DRAWINGSUBMITTAL.12. THE COMPLETED FIRE ALARM SYSTEM SHALL BE FULLY TESTED IN ACCORDANCE WITH NFPA-72H, AND LOCAL FIRE DEPARTMENTREQUIREMENTS BY THE INSTALLER, IN THE PRESENCE OF THE OWNER'S REPRESENTATIVE AND THE LOCAL FIRE MARSHALL. UPON COMPLETE ONA SUCCESSFUL TEST, THE INSTALLER SHALL SO CERTIFY, IN WRITING, TO THE OWNER AND GENERAL CONTRACTOR.13. AUDIBLE ALARM SYSTEM SOUND PRESSURE LEVEL SHALL COMPLY WITH IBC 907.5.2.1.FIRE ALARM PERMIT NOTETHE E.C. BID SHALL INCLUDE THE COST FOR AN INDEPENDENT THIRD PARTY PROFESSIONAL ENGINEER TO SIGN, DATE, AND SEAL ALL FIREALARM DOCUMENTS REQUIRED FOR BUILDING PERMIT. THE FIRE ALARM DOCUMENTS INCLUDED WITH THE E-SERIES DRAWINGS ARE PROVIDEDFOR FIRE ALARM DESIGN INTENT WITHIN THE CITY OF PITTSBURGH. THE CITY OF PITTSBURGH WILL REQUIRE SIGNED/SEALED MANUFACTURERSHOP DRAWINGS (BY THE INDEPENDENT THIRD PARTY) FOR PERMIT APPROVAL BEYOND THE DOCUMENTS CONTAINED IN THE E-SERIESDRAWINGS.THE FIRE ALARM SHOP DRAWINGS SHALL INCLUDE AT A MINIMUM BOTH FIRE ALARM FLOOR PLANS AND RISER DIAGRAM. EACH PLAN OR RISERSHALL INDICATE THE NUMBER AND TYPES OF FIRE ALARM DEVICES INSTALLED ON EACH CIRCUIT, DEVICE ADDRESSES, CONDUCTOR TYPES ANDSIZES, FIRE ALARM ZONES, PRIMARY AND SECONDARY POWER SUPPLIES (AS NECESSARY), AND ALL NEW FIRE ALARM DEVICES AS ADDED TOEXISTING CIRCUITS. DOCUMENTS SHALL ALSO CONTAIN BATTERY AND VOLTAGE DROP CALCULATIONS.FACPEXISTING VOICE EVACUATION SYSTEMFIRE ALARM CONTROL PANEL.FSDDDEXISTING INITIATION CIRCUITFOR FIRE ALARM DEVICES.AVEXTEND EXISTING FIRE ALARM NOTIFICATION CIRCUITFOR NEW FIRE ALARM DEVICES.3RD FLOORVAVEXEXEXEXEXV