HomeMy WebLinkAboutF001 - Fire Protection Data Sheet123456781011121314151617BA91234567810111213141516179DrawnProject ManagerCheckedContract Drawing DateProject NumberQPNMLKJHGFEDCBA18191819QPNMLKJHGFEDCB202120212222TSRTSRRevit Template Versionv16: 2017.10.05This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information itcontains may be copied or used for other than the specific project for which it was prepared without the written consent of BaxterHodell Donnelly Preston, Inc.
CINCINNATI
COLUMBUS
RALEIGH
PITTSBURGH
ATLANTA
LAWRENCE DIGENNARO, ARCHITECT
302 WEST THIRD STREET
SUITE 500
CINCINNATI, OHIO 45202
PHONE 513.271.1634HIG02.21THE HARTFORD GROUP - 3RD FLOOR RENOVATION
501 PENNSYLVANIA PKWY #400
INDIANAPOLIS, IN 46280
No.Issue/Revision/Submission Date
1 ISSUED FOR BID AND PERMIT 12/14/20182016.05.27F001FIRE PROTECTION DATA SHEETZPKJRHDCP SYMBOLCONCEALED PENDENT SPRINKLERCHECK VALVEUPRIGHT SPRINKLERFIRE PROTECTION SCHEDULE AND LEGENDDESCRIPTIONPIPE TURNED UPPIPE TEE DOWNPIPE TURNED DOWNABRV.HORIZONTAL SIDEWALL SPRINKLERPENDENT SPRINKLER: QUICK RESPONSE, CHROME FINISH, WET PIPE SPRINKLER ALARM VALVEFLOW SWITCHFTAMPER SWITCHTSPRINKLER PIPINGSPSPFIRE PROTECTION PIPINGFFCAPPED PIPEFHVFIRE HOSE VALVEECCONCEALED EXTENDED COVERAGE SPRINKLERPIPE TEE UPNOTE: SOME SYMBOLS MAY NOT BE USED ON DRAWINGS.PRESSURE GAUGEPGFIRE DEPARTMENT SIAMESE CONNECTIONOS&Y VALVE WITH TAMPER SWITCHOS&Y VALVEFLOW ARROW - DIRECTION OF FLOWPENDENT SPRINKLER: QUICK RESPONSE, CHROME FINISH, 1" RETURN BEND DROP TO SPRINKLER INCEILINGSPRINKLER BRANCH PIPING1"X 1/2" REDUCERSPRINKLERFINISH CEILINGNOTE:REFER TO FIRE PROTECTION SCHEDULEAND LEGEND FOR ADDITIONALSPRINKLER INFORMATION.THE USE OF AN FMAPPROVED STAINLESSSTEEL FLEXIBLE SPRINKLERCONNECTION IS PERMITTED.1FP001TYPICAL CONCEALED SPRINKLER HEAD RETURN BEND DROPNOT TO SCALESPRINKLER BRANCH PIPINGSPRINKLER1"X 1/2" REDUCERMOUNT DEFLECTOR BETWEEN1" AND 12" FROM DECK ABOVE2FP001TYPICAL UPRIGHT SPRINKLERNOT TO SCALE3 INCH AND LARGERPIPECLEVIS HANGERSUPPORT NUTBAND HANGERLOCKING NUTHANGER ROD2 1/2" AND SMALLEREYE SOCKETSTEEL BEAMEYE SOCKETSTEEL BEAMHEAVY DUTYBEAM CLAMPHEAVY DUTYBEAM CLAMP10'8'MAX. ALLOWABLE SPACING12'10'1"1 1/4"PIPE SIZEROD SIZE1/2" DIA.3/8" DIA.HANGER ROD SCHEDULE2" THRU 3"5/8"1 1/2"6" TO 10"4" THRU 5"PIPE SIZEUP TO 3"HANGER ROD SPACINGVERIFY TYPE OFSPRINKLER ONDRAWINGS.4F001ACOUSTICAL CEILING TILE SPRINKLER LOCATION DETAILNOT TO SCALESPRINKLER BRANCH PIPINGSPRINKLERFINISH CEILING1"X 1/2" REDUCERSPRINKLER IN CEILING1" RETURN BEND DROP TO ADDITIONAL DROP AS REQUIREDNOTE:THE USE OF "FLEX-HEAD" FLEXIBLE RETURNDROPS ARE PERMITTED, PROVIDED THEYARE AN FM APPROVEDPRODUCT.NOTE:REFER TO FIRE PROTECTION SCHEDULEAND LEGEND FOR ADDITIONALSPRINKLER INFORMATION.SPRINKLER TO BE MOUNTED IN CENTEROF NARROW DIMENSION SUSPENDEDCEILING TILE3FP001SPRINKLER RETURN BEND DROPNOT TO SCALEFIRE PROTECTION NOTES AND DESIGN PARAMETERS1.THESE DRAWINGS ARE DIAGRAMATICAL AND SHOW THE GENERAL INTENT OF THE FIRESUPPRESSION SYSTEM. THE CONTRACTOR SHALL PROVIDE FULL SPRINKLER AND HOSEVALVE COVERAGE IN THE PROJECT AREAS. MAKE ADJUSTMENTS TO PIPE RUNS ANDSPRINKLER LOCATIONS SHOWN ON THESE DRAWINGS AS NECESSARY TO COORDINATEWITH OTHER TRADES.2.CONTRACTOR SHALL PERFORM A NEW WATER FLOW TEST OR OBTAIN WATER FLOWINFORMATION FROM BUILDING MANAGEMENT STAFF.3.PROJECT SCOPE INCLUDES: A WET SPRINKLER SYSTEM IN THE OCCUPIED SPACESCOMPLETE WITH NEW BRANCH LINES TAPPED INTO EXISTING CROSS MAINS, NEWTHREADED ARM OVERS OR FLEXIBLE ARM-OVERS, NEW SPRINKLERS, AND SYSTEMTESTING.4.THE CONTRACTOR SHALL HYDRAULICALLY CALCULATE AND DESIGN THE SUPPRESSIONSYSTEMS BASED ON THE RESULTS OF THE NEW WATER FLOW TEST. A 10 PERCENTPRESSURE FACTOR SHALL BE USED BETWEEN THE FLOW TEST RESULTS AND THE DESIGNPRESSURE.5.DESIGN STANDARDS SHALL INCLUDE: INTERNATIONAL BUILDING CODE - CURRENTLYENFORCED EDITION; NFPA -13 - CURRENTLY ENFORCED EDITIONS.6.GENERAL BUILDING CLASSIFICATION: LIGHT HAZARD, ORDINARY HAZARD GROUP 1, ANDORDINARY HAZARD GROUP 2.7.DESIGN DENSITY: LIGHT HAZARD - 0.10 GPM/SQ. FT. OVER 1,50O SQ. FT. WITH 225 SQ. FT.MAXIMUM PER SPRINKLER. ORDINARY HAZARD, GROUP 1 - 0.15 GPM/SQ FT OVER 1,500 SQFT WITH 130 SQ FT MAX PER SPRINKLER. ORDINARY HAZARD, GROUP 2 - 0.20 GPM/SQ FTOVER 1,500 SQ FT WITH 130 SQ FT MAX PER SPRINKLER.8.LOCATE SPRINKLERS AS NECESSARY TO MEET NFPA-13 SPACING RULES AS THEY APPLYTO NEW BUILDING CONSTRUCTION OF NON-COMBUSTIBLE CONSTRUCTION.9.PROVIDE A COMPLETE SET OF LAYOUT DRAWINGS AND HYDRAULIC CALCULATIONS.SUBMIT (3) COPIES OF DRAWINGS AND CALCULATIONS TO THE CITY AND OWNERSINSURANCE COMPANY FOR REVIEW AND APPROVAL PRIOR TO START OF CONSTRUCTION.10.ALL SYSTEM COMPONENTS SHALL BE UL LISTED AND FM/GLOBAL APPROVED.11.PROVIDE INSPECTORS TEST VALVE AT MOST REMOTE AREA AS REQUIRED BY THE CITY,AND AUXILIARY DRAINS AS NECESSITATED BY THE SYSTEM LAYOUT.12. PROVIDE A STANDPIPE FOR USE DURING CONSTRUCTION IN COMPLIANCE WITH SECTION 9OF THE BUILDING CODE. WHEN EXISTING SYSTEMS ARE SHUT DOWN FOR CONSTRUCTION,PROVIDE FIRE WATCH SERVICES UNTIL THE SUPPRESSION SYSTEM IS REACTIVATED.13.COORDINATE FINAL LOCATION OF SPRINKLERS WITH FINAL LOCATION OF ALL LIGHTS,DUCTWORK, DIFFUSERS, STRUCTURAL ELEMENTS AND CEILING ELEVATIONS.CONTRACTOR SHALL PROVIDE AN END PRODUCT OF A FULLY SPRINKLERED PROJECT SITEWITH ALL SPACES COVERED UNDER THE CONTRACT.14.CONTRACTOR SHALL OBTAIN ALL NECESSARY FIRE PROTECTION SYSTEMS PERMITS,TESTS, APPROVALS, AND INSPECTIONS AS PART OF THE SCOPE OF THIS PROJECT.15.STAINLESS STEEL FLEXIBLE ARM-OVERS MAY BE USED FROM BRANCH LINES TO THESPRINKLERS.16.THE INDICATED SCOPE OF THE DRAWINGS ARE FOR GUIDANCE ONLY AND REPRESENTSTHE LIMIT OF GENERAL CONSTRUCTION WORK. THIS CONTRACTOR MAY BE REQUIRED TODO WORK IN AREAS OUTSIDE OF THIS SCOPE WHERE NECESSARY TO DEMOLISH, INSTALLNEW SYSTEMS OR EXTEND TO EXISTING SYSTEMS IN ORDER TO PERFORM THE WORKINDICATED ON THESE DRAWINGS. COORDINATE WITH OWNER'S REPRESENTATIVE TO GAINACCESS TO ADJOINING SPACES AND TO MINIMIZE DISRUPTION OF SERVICES.SPRINKLER SCHEDULETYPE SYMBOLTYPE DESCRIPTIONMANUFACTURER & MODEL NUMBERSINK-FACTORFINISHTEMP RATINGPSI RATINGUPRIGHT SPRINKLERVIKING MICROFAST QUICK RESPONSEVK3005.6BRASS/CHROME 155 °F TYPICAL, 212 °FMECHANICAL ANDELECTRICAL SPACES175SEMI RECESSED SPRINKLERVIKING MICROFAST QUICK RESPONSEVK3025.6CHROME/WHITE155 °F175DRY PENDENT (USE IN FREEZINGENVIRONMENTS)VIKING STANDARD RESPONSEVK1545.6CHROME155 °F175CONCEALED PENDENT SPRINKLERVIKING MIRAGE QUICK RESPONSEVK4625.6COLOR SELECTED BYARCHITECT155 °F WITH 135 °FCOVER PLATE175CONCEALED EXTENDED COVERAGESPRINKLERVIKING MIRAGE QUICK RESPONSEVK6325.6COLOR SELECTED BYARCHITECT155 °F WITH 135 °F COVERPLATE175PENDENT SPRINKLERVIKING MICROFAST QUICK RESPONSEVK3025.6CHROME155 °F TYPICAL, 212 °FMECHANICAL ANDELECTRICAL SPACES175HORIZONTAL SIDEWALL SPRINKLERVIKING MICROFAST QUICK RESPONSEVK3055.6CHROME155 °F WITH CHROME MODEL175DRY HORIZONTAL SIDEWALLSPRINKLER (USE IN FREEZINGENVIRONMENTS)VIKING STANDARD RESPONSEVK1625.6CHROME155 °F WITH CHROME MODEL175ATTIC SPRINKLER, HIPTYCO QUICK RESPONSE-5.6BRASS212 °F175ATTIC SPRINKLER, SINGLEDIRECTIONALTYCO QUICK RESPONSE-5.6BRASS212 °F175ATTIC SPRINKLER, BACK TO BACKTYCO QUICK RESPONSE-5.6BRASS212 °F175NOTE: SOME SYMBOLS MAY NOT BE USED ON DRAWINGSDPECDSHPSDBB15'4" THRU 10"5FP001SPRINKLER PIPE HANGER INSTALLATION DETAILNOT TO SCALESPRINKLERFLEXHEAD SPRINKLER DROPCORRUGATED STAINLESS STEEL HOSE WITH STAINLESS STEEL BRAIDAVAILABLE IN 2', 3',4',5' & 6' LENGTHSADJUSTABLE HUBMULTI-PORT BRACKETFP0016FLEXHEAD COMMERCIAL CEILING UNITNOT TO SCALE