CODE SUMMARY
SCOPE OF WORK
OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE
OCCUPANCY CLASSIFICATION
B(USINESS)
CHANGE OF OCCUPANCY CLASS?
NO
TOTAL BUILDING AREA
34,480 SF/FLOOR
X
4STORIES
=
137,920 SF
TOTAL PROJECTAREA
2,065 SF
OCCUPANCY CALCULATIONS
SPACE TYPE
AREA
SF PER OCCUPANT
OCCUP LOAD
GEN. OFFICE
20655F
100
21
TOTAL OCCUPANTS IN PROJECTAREA 21
REQUIRED:I PROVIDED.2
NUMBER OF REQUIRED EXITS
SPRINKLER SYSTEM(YES/NO)
YES- EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
34,480 SF
ACCESSORY AREA EXCEEDS 10%
NO
FIREWALLS, AND/OROCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
ASHRAE 90.1 SUMMARY
EXEMPT(NO LIGHTING WORK -ALL EXISTINGTO REMAIN)
BUI LT BEFORE 19782
NO
BUI LDING CONSTRUCTION TYPE
II-B
LEGEND
Ep EXISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXIT
FE fF FIRE EXTINGUISHER
® NEW EXIT SIGN
® EXISTING EXIT SIGN
NEW EMERGENCY LIGHT
EXISTING EMERGENCY LIGHT
— — — TRAVEL DISTANCE
TRAVEL DISTANCI
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 04/29/19
LIFE SAFETY NOTES
I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS ATTHEIR EXPENSE.
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10, COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINTTO A VISIBLE EXTINGUISHER,
GENERAL NOTES
LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE
PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO
REMAIN. RELOCATE EXISTING EXITSIGNS, FIRE PULLS, FIRE
EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET
ALL LOCAL AND STATE CODES.
Q E
O
N d O U
N V O C
L Z r` N
d-n
O n 0
w O M N
c
N
V
c
'vw]
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOTTO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUTTHE WRITTEN
CONSENT OF SCH07 DESIGN.
0
DO
CV
z
O N
J
r
O
W
y~
W z
H o
=
LU
ZZrz
WHY 3
n� iL
V z
�O
Q
Z
. w L J
V W >-
z
z
w I
w
0
ch
ISSUE
DATE
DESCRIPTION
03.11.19
REVIEW SET
03.12.19
PERMITSET
REVISIONS
ARK
DATE
DB
DESCRIPTION
H 80I
�_
No.
70 AR10700017
STATE OF
TFRED PR��
PROJECT NUMBER
2019.024
PROD. MGR DRAWN BY
BW SO
1ST FLOOR
LIFE SAFETY
L 100