HomeMy WebLinkAboutL100 1st Floor Life Safety2 3 4 5 6 7 8 9 10 11 12 13 14 15 CODE SUMMARY SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE OCCUPANCY CLASSIFICATION B(USINESS) CHANGE OF OCCUPANCY CLASS? NO TOTAL BUILDING AREA 34,480 SF/FLOOR X 4STORIES = 137,920 SF TOTAL PROJECTAREA 2,065 SF OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD GEN. OFFICE 20655F 100 21 TOTAL OCCUPANTS IN PROJECTAREA 21 REQUIRED:I PROVIDED.2 NUMBER OF REQUIRED EXITS SPRINKLER SYSTEM(YES/NO) YES- EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR 34,480 SF ACCESSORY AREA EXCEEDS 10% NO FIREWALLS, AND/OROCCUPANCY SEPARATIONS (IF REQUIRED) N/A ASHRAE 90.1 SUMMARY EXEMPT(NO LIGHTING WORK -ALL EXISTINGTO REMAIN) BUI LT BEFORE 19782 NO BUI LDING CONSTRUCTION TYPE II-B LEGEND Ep EXISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT FE fF FIRE EXTINGUISHER ® NEW EXIT SIGN ® EXISTING EXIT SIGN NEW EMERGENCY LIGHT EXISTING EMERGENCY LIGHT — — — TRAVEL DISTANCE TRAVEL DISTANCI RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 04/29/19 LIFE SAFETY NOTES I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS ATTHEIR EXPENSE. 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10, COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINTTO A VISIBLE EXTINGUISHER, GENERAL NOTES LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXITSIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. Q E O N d O U N V O C L Z r` N d-n O n 0 w O M N c N V c 'vw] THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOTTO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUTTHE WRITTEN CONSENT OF SCH07 DESIGN. 0 DO CV z O N J r O W y~ W z H o = LU ZZrz WHY 3 n� iL V z �O Q Z . w L J V W >- z z w I w 0 ch ISSUE DATE DESCRIPTION 03.11.19 REVIEW SET 03.12.19 PERMITSET REVISIONS ARK DATE DB DESCRIPTION H 80I �_ No. 70 AR10700017 STATE OF TFRED PR�� PROJECT NUMBER 2019.024 PROD. MGR DRAWN BY BW SO 1ST FLOOR LIFE SAFETY L 100