Loading...
HomeMy WebLinkAbout14294_CO_LO_CARDENAS_LOT_9024" O/C 24" O/C 24" O/C24" O/C 24" O/C 2X4 LEDGER BY OTHER PORCH BEAM BY OTHER 8/12 4/12 LOCATE TRUSSES AS NEEDED FOR PDS & CHASE STUDTOC/LBEAM HEEL HEIGHT @ GARAGE BASED ON 2X6 FACIA@1'-3"ABOVE 1ST FLOOR PLATE HEEL HEIGHT @ PORCH BASED ON 2X6 FACIA @ 2"ABOVE1STFLOOR PLATE HEEL HEIGHT @ PORCH BASED ON 2X6 FACIA @ 2-1/2"BELOW1ST FLOOR PLATE HEEL HEIGHT @ 2ND FLOOR BASED ON 2X6 FACIA@1'-1"ABOVE 2ND FLOOR PLATE NOTE: ALL DIMENSIONS ARE TO STUD FRAMING. UNO ALL DIMENSIONS MUST BE VERIFIED. ALL TRUSSES MUST BE REVIEWD AND VERIFIED PRIOR TO PRODUCTION.C/LPOSTTOC/LPOST UPPER ROOF STUD FRAMING TO C/L PDS 8/12 PORCH BEAM BY OTHER 2X4 LEDGER BY OTHER 2-ply TRUSSES TO CARRY LADDER FRAMING BY OTHERS FOR ATTIC ACCESS 2-ply TRUSSES TO CARRY LADDER FRAMING BY OTHER FOR CHASE 5/12(2-PLY)(2-PLY)(2-PLY)(2-PLY)CL Roof Data Roof Area: 2801.56 Overhang Length: 178.84 Eave Length: 211.71 Hip Length: 0 Valley Length: 11.7 Ridge Length: 75.75 Hatch Legend = OVERFRAME BY OTHER LG1M2G M3G M1G M1T1GV1 V2V3M2(6)M3(2)M1A(3)T1(12) 5-09-06 17-05-001-00-10 8-01-0210-01-02 11-08-04 1-04-00 10-01-022-02-00 11-08-04 1-06-08 1-03-00 8-031-03-001-05-001-03-0023-00-004-02-06 2-00 7-12 1-10-12 1-10-00 5-00-00 1-10-082-081-081-08LG2LG1T2GT3SGT3A T3A T3A T3AT3SGAT4GT5GT2(5) T3(2) T3(9) T3(2) 22-08-08 46-07-08 10-01-02 1-00-10 8-01-021-01-00 2-00-00 1-04-00 10-01-02 1-00-108-01-022-08 1-06-08 5-04 37-05-08 1-04-001-04-0011-06-005-03-00 12-07-00 10-09-08 18-06-081X 1-03-00 4-08-10 6-06-00 11-10-00 1-02-088-00-00 4-001-02-0811-09-04 3-08 1-02-08IMPORTANT THIS DRAWING IS FOR FIELD PLACEMENT OF INDIVIDUAL COMPONENTS ONLY, AND DOES NOT CONSTITUTE AN ENGINEERED DOCUMENT. NOTE PROPER BEARING AND BEARING DESIGN INCLUDING ANCHORAGE, IS THE RESPONSIBILITY OF THE BUILDING DESIGNER, ARCHITECT AND / OR BUILDING ENGINEER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS, MINIMUM REQUIRED BEARING SIZE, UPLIFT, AND ADDITIONAL LOADS. 84 COMPONENTS DOES NOT ASSUME RESPONSIBILITY IN THESE AREAS OF CONCERN. BRACING ERECTION, TEMPORARY, AND PERMANENT BRACING IS THE RESPONSIBILITY OF THE CONTRACTOR AND / OR BUILDING DESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR ADDITIONAL BRACING REQUIREMENTS. REFER TO BCSI-B1 SUMMARY SHEET. THE STRUCTURAL BUILDING COMPONENTS ASSOCIATION COMMENTARY, AND RECOMMENDATIONS FOR HANDLING, INSTALLING & BRACING METAL PLATE CONNECTED WOOD TRUSSES. www.sbcindustry.com INSTALLATION DO NOT CUT, DRILL, OR ALTER TRUSSES. ANY QUESTIONS CALL 84 COMPONENTS. PROPER INSTALLATION, AND HANDLING OF COMPONENTS IS THE RESPONSIBILITY OF THE ERECTING CONTRACTOR. 84 COMPONENTS MUST BE NOTIFIED OF ANY PROBLEMS, AND AFFORDED THE OPPORTUNITY TO REVIEW, AND MAKE NECESSARY CORRECTIONS, OR NO BACK CHARGES WILL BE ACCEPTED OR APPROVED. WARNING WARNINGS, AND INSTRUCTIONS FOR ERECTION OF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE. KEEP THIS INFORMATION ON THE JOB SITE. THESE DOCUMENTS WILL ALSO BE NEEDED FOR JOB SITE INSPECTION. MISUSE AND IMPROPER INSTALLATION OF COMPONENTS MAY RESULT IN FAILURE, BODILY INJURY, LOSS OF PROPERTY, AND / OR LIFE. Roof Area: Overhang Length: Eave Length: Hip Length: Valley Length: Ridge Length: SHEET NUMBER: R1.1 Roof Truss Placement Plan SCALE: NTS Job#: 14294 PO#: Date: 1/21/2019 Drawn By: TS Designed By: TS Checked By: KC ROOF LOADS: TCLL: 20.0 lb/ft² TCDL: 10.0 lb/ft² BCLL: 0.0 lb/ft² BCDL:10.0 lb/ft² Building Code: IBC 2012 Wind Speed: 90 mph On-CenterSpacing:24"U.N.O. 2801.56 SF 178.84 LF 211.71 LF 0 LF 11.7 LF 75.75 LF ROOF DATA THISLAYOUTISINTENDEDFORTHEPURPOSEOFTRUSSLOCATIONANDPLACEMENTONLY.REFERTOTHEBUILDINGPLANSFORACTUALBUILDING CONSTRUCTION.CARDENAS LOT 90OLD TOWN9856 BUCKLEBERRY LANEINDIANAPOLIS,IN ROOFTRUSSPLACEMENTPLAN 142941850 N Graham RoadFranklin, Indiana 46131Office:(317) 346-4274Fax:(317) 346-091604/08/19 Mike Sheeks