Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
14294_Cardenas lot 90_Seals
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by 84 Components - 0783. January 22,2019 Liu, Xuegang Pages or sheets covered by this seal: I35906415 thru I35906434 My license renewal date for the state of Ohio is December 31, 2019. 14294 Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: 14294_CARDENAS_LOT_90 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss M1 Truss Type MONOPITCH Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906415 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:43 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-Czppv2Vj6lTKPJGlrc0jhX9yBBwZeftDdfKueozsuLk Scale = 1:26.2 1 2 3 4 5 7 6 14 3x4 2x4 4x4 3x6 4x4 4x40-2-140-2-8 0-2-8 6-10-3 6-7-11 11-11-12 5-1-9 -1-2-8 1-2-8 6-10-3 6-10-3 11-10-4 5-0-1 11-11-12 0-1-8 0-8-34-8-24-4-100-3-84-8-24.00 12 Plate Offsets (X,Y)-- [2:Edge,0-0-1] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.28 0.28 0.44 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.08 0.01 (loc) 7-12 7-12 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud SLIDER Left 2x4 SPF Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS. (lb/size) 2=565/0-3-0, 6=454/0-1-8 Max Horz 2=145(LC 11) Max Uplift 2=-90(LC 8), 6=-67(LC 12) Max Grav 2=583(LC 19), 6=525(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-686/126 BOT CHORD 2-7=-90/604, 6-7=-90/604 WEBS 4-6=-660/167 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 90 lb uplift at joint 2 and 67 lb uplift at joint 6. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss M1A Truss Type MONOPITCH Qty 3 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906416 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:44 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-gANB6NVLt3bB1TrxPKXyEkh7NaGUN5mNsJ3SBEzsuLj Scale = 1:25.6 1 2 3 4 6 5 11 3x6 4x4 3x4 2x4 4x4 4x4 6-8-0 6-8-0 11-9-8 5-1-9 6-8-0 6-8-0 11-8-0 5-0-1 11-9-8 0-1-8 0-8-154-8-24-4-100-3-84-8-24.00 12 Plate Offsets (X,Y)-- [1:0-2-8,0-0-7] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.32 0.30 0.46 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.09 0.02 (loc) 6-9 6-9 1 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud SLIDER Left 2x4 SPF Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS. (lb/size) 1=466/0-3-8, 5=466/0-1-8 Max Horz 1=137(LC 11) Max Uplift 1=-46(LC 8), 5=-69(LC 12) Max Grav 1=479(LC 19), 5=526(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-666/143 BOT CHORD 1-6=-108/632, 5-6=-108/632 WEBS 3-5=-696/188 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 46 lb uplift at joint 1 and 69 lb uplift at joint 5. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss M1G Truss Type GABLE Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906417 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:45 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-8MxZKjWzeNk2fdQ8z12BmyEK0_gi6faW5zp?jgzsuLi Scale: 1/2"=1'Sheet Front Full Sheathing 1 Ply Tyvek 4x8 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 3x6 4x4 -1-2-8 1-2-8 11-11-12 11-11-12 0-8-34-8-24.00 12 Plate Offsets (X,Y)-- [2:0-4-4,0-0-5], [12:Edge,0-1-14] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.13 0.04 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 1 1 12 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 55 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud SLIDER Left 2x4 SPF Stud 1-6-8 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 11-11-12. (lb) - Max Horz 2=143(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 12, 2, 13, 14, 15, 16, 17, 18, 19 Max Grav All reactions 250 lb or less at joint(s) 12, 2, 13, 14, 15, 16, 17, 18, 19 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 2, 13, 14, 15, 16, 17, 18, 19. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss M2 Truss Type MONOPITCH Qty 6 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906418 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:46 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-cYUxX3XbPgsvGn?KXlaQJ9nUxOy4r6QgKdYYF7zsuLh Scale = 1:15.3 1 2 3 4 8 2x4 3x4 3x6 2x40-1-70-3-8 0-3-8 4-11-14 4-8-6 -1-2-8 1-2-8 4-11-14 4-11-14 0-5-42-6-32-2-110-3-82-6-35.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-8], [2:0-0-1,0-9-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.25 0.22 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.07 0.01 (loc) 4-7 4-7 2 l/defl >999 >853 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS. (lb/size) 2=275/0-3-0, 4=185/0-1-8 Max Horz 2=76(LC 11) Max Uplift 2=-41(LC 12), 4=-28(LC 12) Max Grav 2=278(LC 19), 4=198(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 19.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss M2G Truss Type GABLE Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906419 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:47 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-4l2JkPYDA__muxaW4S5fsNJgUoKgaZ0pYHI6nZzsuLg Scale = 1:15.3 Sheet Back Full Sheathing 1 Ply Tyvek 4x8 1 2 3 4 6 5 2x4 2x42x4 2x4 2x4 0-3-8 0-3-8 4-11-14 4-8-6 -1-2-8 1-2-8 4-10-6 4-10-6 4-11-14 0-1-8 0-5-42-6-35.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.13 0.07 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=12/4-8-6, 2=200/4-8-6, 6=248/4-8-6 Max Horz 2=75(LC 9) Max Uplift 5=-8(LC 11), 2=-31(LC 8), 6=-45(LC 12) Max Grav 5=19(LC 19), 2=205(LC 18), 6=256(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 19.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2, 6. 10) Non Standard bearing condition. Review required. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss M3 Truss Type MONOPITCH Qty 2 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906420 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:48 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-YxciylYrxI6dW59ieAcuOasnOCcCJ0vynx1fK?zsuLf Scale = 1:18.5 1 2 3 4 8 2x4 4x4 3x6 2x4 0-3-8 0-3-8 6-3-14 6-0-6 -1-2-8 1-2-8 6-2-6 6-2-6 6-3-14 0-1-8 0-5-43-0-142-9-60-3-83-0-145.00 12 Plate Offsets (X,Y)-- [2:0-0-7,0-1-0], [2:0-0-1,0-9-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.44 0.37 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.01 (loc) 4-7 4-7 2 l/defl >999 >403 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS. (lb/size) 2=327/0-3-0, 4=240/0-1-8 Max Horz 2=94(LC 11) Max Uplift 2=-45(LC 12), 4=-37(LC 12) Max Grav 2=332(LC 19), 4=263(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 19.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss M3G Truss Type GABLE Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906421 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:49 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-17A495ZUibEU8EjvCt77xoP0_b0w2TQ60bnCsSzsuLe Scale = 1:18.4 Sheet Front Full Sheathing 1 Ply Tyvek 4x8 1 2 3 4 5 8 7 6 2x4 2x42x4 2x4 2x4 2x4 2x4 0-3-8 0-3-8 6-3-14 6-0-6 -1-2-8 1-2-8 6-2-6 6-2-6 6-3-14 0-1-8 0-5-43-0-145.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.13 0.09 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 6-0-6. (lb) - Max Horz 2=93(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 6, 2, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7 except 8=286(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 19.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 2, 7, 8. 10) Non Standard bearing condition. Review required. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss T1 Truss Type Common Qty 12 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906422 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:50 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-VKkSNRa6SvMLlOI5mbeMT?x8x?Gbns_FEFWmOuzsuLd Scale = 1:61.7 1 2 3 4 5 6 7 12 11 10 9 813 14 15 16 17 4x6 3x6 4x4 4x4 4x4 4x4 3x4 4x4 4x4 3x4 7-9-3 7-9-3 15-2-13 7-5-11 23-0-0 7-9-3 -1-3-0 1-3-0 5-10-12 5-10-12 11-6-0 5-7-4 17-1-4 5-7-4 23-0-0 5-10-12 24-3-0 1-3-0 2-2-09-10-02-2-08.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.38 0.51 0.28 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.10 -0.19 0.03 (loc) 9-11 8-9 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 119 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 5-9,3-11,2-12,6-8: 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-12, 5-8 REACTIONS. (lb/size) 12=992/0-3-8, 8=992/0-3-8 Max Horz 12=-220(LC 8) Max Uplift 12=-76(LC 10), 8=-76(LC 11) Max Grav 12=1033(LC 18), 8=1031(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-969/223, 4-5=-967/223, 2-12=-316/172, 6-8=-316/172 BOT CHORD 11-12=-67/861, 9-11=0/658, 8-9=-5/764 WEBS 4-9=-91/432, 4-11=-91/437, 3-12=-968/17, 5-8=-965/17 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss T1G Truss Type GABLE Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906423 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:52 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-RisCo6bM_Wc3?iSUt?gqZQ1U0p1jFpGYiZ?tTmzsuLb Scale = 1:60.5 Sheet Front Full Sheathing 1 Ply Tyvek 4x8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 3x4 3x4 4x4 3x4 3x43x6 23-0-0 23-0-0 -1-3-0 1-3-0 11-6-0 11-6-0 23-0-0 11-6-0 24-3-0 1-3-0 2-2-09-10-02-2-08.00 12 Plate Offsets (X,Y)-- [33:0-2-0,0-1-8] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.28 0.15 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 -0.00 (loc) 21 20 22 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 174 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud *Except* 11-31,10-32,9-34,12-30,13-29: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 11-31, 10-32, 12-30 REACTIONS. All bearings 23-0-0. (lb) - Max Horz 41=-220(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 32, 34, 35, 36, 37, 38, 39, 30, 29, 28, 27, 26, 25, 24 except 41=-330(LC 6), 22=-308(LC 7), 40=-308(LC 7), 23=-289(LC 6) Max Grav All reactions 250 lb or less at joint(s) 31, 32, 34, 35, 36, 37, 38, 39, 30, 29, 28, 27, 26, 25, 24 except 41=372(LC 9), 22=353(LC 18), 40=355(LC 8), 23=334(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 9-10=-190/278, 10-11=-200/288, 11-12=-200/288, 12-13=-190/278 WEBS 11-31=-255/136 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 32, 34, 35, 36, 37, 38, 39, 30, 29, 28, 27, 26, 25, 24 except (jt=lb) 41=330, 22=308, 40=308, 23=289. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss T2 Truss Type FINK Qty 5 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906424 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:53 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-vvQb?Sc_lqkwcs1gRjC35eZgTDH7_A8ixDlQ?DzsuLa Scale = 1:49.9 1 2 3 4 5 6 7 12 11 10 9 8 13 14 3x6 4x6 4x4 4x4 4x4 4x4 2x4 4x4 2x4 4x4 5-6-0 5-6-0 13-0-8 7-6-7 18-6-8 5-6-0 -1-3-0 1-3-0 3-7-6 3-7-6 9-3-4 5-7-14 14-11-2 5-7-14 18-6-8 3-7-6 19-9-8 1-3-0 2-0-08-2-32-0-08.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.23 0.45 0.45 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.24 0.02 (loc) 9-11 9-11 8 l/defl >999 >916 n/a L/d 240 180 n/a PLATES MT20 Weight: 94 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* 4-11,4-9: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS. (lb/size) 12=814/0-3-8, 8=814/0-3-8 Max Horz 12=-186(LC 8) Max Uplift 12=-65(LC 10), 8=-65(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-718/170, 4-5=-719/170 BOT CHORD 11-12=-64/621, 9-11=0/485, 8-9=-17/526 WEBS 4-11=-53/275, 4-9=-53/275, 3-12=-796/36, 5-8=-796/36 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss T2G Truss Type GABLE Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906425 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:55 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-rHXLQ8eFHR_dsAB3Y8EXA3f0Q03?S85_OXEX35zsuLY Scale = 1:50.6 Sheet Front Full Sheathing 1 Ply Tyvek 4x8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 3x4 3x4 4x4 3x4 3x4 5x6 18-6-8 18-6-8 -1-3-0 1-3-0 9-3-4 9-3-4 18-6-8 9-3-4 19-9-8 1-3-0 2-0-08-2-32-0-08.00 12 Plate Offsets (X,Y)-- [25:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.20 0.11 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 -0.00 (loc) 17 16 18 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 125 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud *Except* 9-25: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 18-6-8. (lb) - Max Horz 32=-186(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 26, 27, 28, 29, 30, 24, 23, 22, 21, 20 except 32=-175(LC 6), 18=-164(LC 7), 31=-172(LC 7), 19=-162(LC 6) Max Grav All reactions 250 lb or less at joint(s) 18, 25, 26, 27, 28, 29, 30, 31, 24, 23, 22, 21, 20, 19 except 32=253(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 26, 27, 28, 29, 30, 24, 23, 22, 21, 20 except (jt=lb) 32=175, 18=164, 31=172, 19=162. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss T3 Truss Type Common Qty 13 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906426 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:56 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-JU5jdUft2l6UTJmF6rlmjGB5PQDOBWO8dBz4cYzsuLX Scale = 1:70.5 1 2 3 4 5 6 7 8 9 14 13 12 11 1015 16 17 18 19 20 3x6 4x6 3x6 3x8 MT18HS 4x4 4x4 4x4 4x4 4x6 4x8 4x8 4x6 9-10-8 9-10-8 19-5-8 9-7-0 29-4-0 9-10-8 -1-3-0 1-3-0 7-5-12 7-5-12 14-8-0 7-2-4 21-10-4 7-2-4 29-4-0 7-5-12 30-7-0 1-3-0 2-0-011-9-52-0-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge], [8:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.63 0.87 0.54 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.24 -0.48 0.06 (loc) 11-13 10-11 10 l/defl >999 >733 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 146 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-11,3-13,2-14,8-10: 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-14, 7-10 REACTIONS. (lb/size) 14=1245/0-3-8, 10=1245/0-3-8 Max Horz 14=-256(LC 8) Max Uplift 14=-92(LC 10), 10=-92(LC 11) Max Grav 14=1338(LC 18), 10=1338(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-367/162, 3-5=-1373/279, 5-7=-1373/279, 7-8=-367/162, 2-14=-428/196, 8-10=-427/196 BOT CHORD 13-14=-103/1231, 11-13=0/903, 10-11=-9/1106 WEBS 5-11=-115/639, 5-13=-115/639, 3-14=-1262/37, 7-10=-1262/37 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 10. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss T3A Truss Type COMMON Qty 4 Ply 2 14294_CARDENAS_LOT_90 Job Reference (optional) I35906427 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:07:58 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-GsDT2Ag7aMMCjdvdEGnEohHTDExefOcR4VSBgQzsuLV Scale = 1:70.0 1 2 3 4 5 6 7 8 9 14 13 12 11 1015 16 17 18 19 20 3x6 4x6 3x6 3x6 9-10-8 9-10-8 19-5-8 9-7-0 29-4-0 9-10-8 -1-3-0 1-3-0 7-5-12 7-5-12 14-8-0 7-2-4 21-10-4 7-2-4 29-4-0 7-5-12 30-7-0 1-3-0 2-0-011-9-52-0-08.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-12], [8:0-2-0,0-1-12] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 3-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MS 0.49 0.75 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.41 0.04 (loc) 11-13 10-11 10 l/defl >999 >847 n/a L/d 240 180 n/a PLATES MT20 Weight: 292 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-11,3-13,2-14,8-10: 2x4 SPF Stud BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals (Switched from sheeted: Spacing > 2-8-0). BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 14=1868/0-3-8, 10=1868/0-3-8 Max Horz 14=-383(LC 8) Max Uplift 14=-139(LC 10), 10=-139(LC 11) Max Grav 14=2006(LC 18), 10=2006(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-487/259, 3-5=-2068/421, 5-7=-2068/421, 7-8=-487/259, 2-14=-601/302, 8-10=-601/302 BOT CHORD 13-14=-155/1849, 11-13=0/1351, 10-11=-14/1662 WEBS 5-11=-177/973, 7-11=-356/373, 5-13=-177/973, 3-13=-356/373, 3-14=-1966/40, 7-10=-1966/40 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 4x4 MT20 unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 14=139, 10=139. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss T3SG Truss Type Common Structural Gable Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906428 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:08:00 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-CFLETsiN6_dwyx30Lhqit6MnW1c87JPkYpxIlJzsuLT Scale = 1:80.8 Sheet Front Right Option 10-9-8 1 Ply Tyvek 4x8 1 2 3 4 5 6 7 8 9 19 18 17 16 15 14 13 12 11 1050 51 52 53 8x16 MT18HS 3x16 MT18HS 3x6 4x4 4x4 4x4 4x4 4x6 4x6 4x6 4x6 5x6 5x6 9-10-8 9-10-8 18-6-8 8-8-0 19-5-8 0-11-0 29-4-0 9-10-8 -1-3-0 1-3-0 7-5-12 7-5-12 7-9-4 0-3-8 14-8-0 6-10-12 21-10-4 7-2-4 29-4-0 7-5-12 30-7-0 1-3-0 2-0-011-9-52-0-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge], [4:0-3-0,0-3-0], [5:0-8-0,0-10-0], [6:0-3-0,0-3-0], [8:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.63 0.75 0.54 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.47 0.02 (loc) 18-19 18-19 10 l/defl >999 >469 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 249 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-15,3-18,2-19,8-10: 2x4 SPF Stud OTHERS 2x4 SPF Stud *Except* 5-20: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 5-15, 3-19, 7-10 REACTIONS. All bearings 11-1-0 except (jt=length) 19=0-3-8. (lb) - Max Horz 19=-256(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 19, 10 except 15=-253(LC 11) Max Grav All reactions 250 lb or less at joint(s) 16, 14, 13, 12, 11 except 15=836(LC 1), 19=880(LC 18), 10=403(LC 1), 16=635(LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-355/161, 3-5=-724/239, 2-19=-418/195, 8-10=-346/217 BOT CHORD 18-19=-104/729, 16-18=-48/325, 15-16=-48/325 WEBS 5-15=-771/58, 7-15=-419/257, 5-18=-118/734, 3-18=-332/246, 3-19=-602/6 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 10 except (jt=lb) 15=253. 11) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss T3SGA Truss Type GABLE Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906429 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:08:04 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-40alJDlu9C7MRYNnaXue2yWSEe_d38EJSQvVu4zsuLP Scale = 1:81.7 Sheet Back Left Option 11-6-0 1 Ply Tyvek 4x8 1 2 3 4 5 6 7 8 9 23 22 21 20 19 18 17 16 15 14 12 11 10 73 74 13 75 76 77 3x6 8x16 MT18HS 3x16 MT18HS 3x6 3x6 4x4 4x4 4x4 4x4 4x6 4x6 4x6 4x6 9-10-8 9-10-8 11-6-0 1-7-8 19-5-8 7-11-8 29-4-0 9-10-8 -1-3-0 1-3-0 7-5-12 7-5-12 14-8-0 7-2-4 21-10-4 7-2-4 21-11-0 0-0-12 29-4-0 7-5-0 30-7-0 1-3-0 2-0-011-9-52-0-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge], [5:0-8-0,0-10-0], [8:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.64 0.71 0.49 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.49 0.02 (loc) 10-11 10-11 10 l/defl >999 >429 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 300 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-11,3-15,2-23,8-10: 2x4 SPF Stud OTHERS 2x4 SPF Stud *Except* 5-24,25-27,46-47: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 5-15, 3-23, 7-10 REACTIONS. All bearings 11-9-8 except (jt=length) 10=0-3-8, 13=0-3-8. (lb) - Max Horz 23=-256(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 23, 10, 16, 22 except 15=-179(LC 10), 14=-401(LC 17) Max Grav All reactions 250 lb or less at joint(s) 16, 17, 18, 19, 20, 21, 22 except 15=1137(LC 18), 23=408(LC 1), 10=898(LC 19), 13=528(LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-7=-746/242, 7-8=-361/160, 2-23=-345/218, 8-10=-422/195 BOT CHORD 14-15=-17/299, 13-14=-17/299, 11-13=-17/299, 10-11=-12/576 WEBS 5-11=-119/713, 7-11=-329/243, 5-15=-695/28, 3-15=-429/263, 7-10=-551/0 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 10, 16, 22 except (jt=lb) 15=179, 14=401. 11) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss T4G Truss Type GABLE Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906430 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:08:06 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-1PiVkvm8hqN3gsXAiyw67NcqYSjNX17cwkOcyyzsuLN Scale = 1:50.2 Sheet Back Left Option 5-3-0 1 Ply Tyvek 4x8 1 2 3 4 5 6 7 14 13 12 11 9 8 10 4x4 4x8 4x44x4 3x4 4x6 3x4 4x6 6-3-8 5-3-0 2-0-05-3-0 5-3-0 8-11-0 3-8-0 17-10-0 8-11-0 -1-3-0 1-3-0 4-7-4 4-7-4 8-11-0 4-3-12 13-0-8 4-1-8 13-2-12 0-2-4 17-10-0 4-7-4 19-1-0 1-3-0 2-0-07-11-52-0-08.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.53 0.50 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.35 0.02 (loc) 8-9 8-9 8 l/defl >999 >423 n/a L/d 240 180 n/a PLATES MT20 Weight: 142 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* 4-9: 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS. All bearings 5-6-8 except (jt=length) 8=0-3-8, 10=0-3-8. (lb) - Max Horz 14=-181(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 8, 10 except 14=-104(LC 10) Max Grav All reactions 250 lb or less at joint(s) 11, 12, 13, 10 except 14=715(LC 1), 8=768(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-556/148, 4-5=-556/148, 6-8=-273/138 BOT CHORD 13-14=-65/495, 12-13=-65/495, 11-12=-65/495, 10-11=-65/495, 9-10=-65/495, 8-9=-16/462 WEBS 4-9=-68/320, 3-14=-629/23, 5-8=-566/58 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 10 except (jt=lb) 14=104. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss T5G Truss Type GABLE Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906431 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:08:07 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-VbGtxFnmS7VwI05MFfSLgb83Ws9AGbsl9O89VPzsuLM Scale = 1:35.2 Sheet Front Full Sheathing 1 Ply Tyvek 4x8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 4x4 1-1-012-7-0 12-7-0 -1-3-0 1-3-0 6-3-8 6-3-8 12-7-0 6-3-8 13-10-0 1-3-0 2-0-06-2-52-0-08.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.19 0.08 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 -0.00 (loc) 13 12 14 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 12-7-0. (lb) - Max Horz 24=-148(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 20, 21, 22, 18, 17, 16 except 24=-163(LC 6), 14=-154(LC 7), 23=-151(LC 7), 15=-144(LC 6) Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 21, 22, 18, 17, 16 except (jt=lb) 24=163, 14=154, 23=151, 15=144. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss V1 Truss Type Valley Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906432 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:08:08 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-znqF8boODRdnv9gYpNzaCohDuGUm?3svN2tj1rzsuLL Scale = 1:21.5 1 2 3 4 5 2x4 2x43x6 3x4 -1-1-14 1-1-14 4-5-8 4-5-8 0-8-123-8-78.00 12 Plate Offsets (X,Y)-- [2:0-4-1,0-0-2] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.28 0.19 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 0.01 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud SLIDER Left 2x4 SPF Stud 2-6-10 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=167/4-5-8, 2=231/4-5-8 Max Horz 2=99(LC 7) Max Uplift 5=-39(LC 10), 2=-19(LC 10) Max Grav 5=180(LC 18), 2=231(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss V2 Truss Type Valley Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906433 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:08:09 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-R_NeMwp1_kleXJFlN4Upl0EP9fqYkW62cidGZHzsuLK Scale = 1:18.1 1 2 3 2x4 2x4 2x4 4-5-8 4-5-8 0-0-43-0-78.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.25 0.15 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=157/4-6-5, 3=157/4-6-5 Max Horz 1=77(LC 7) Max Uplift 1=-6(LC 10), 3=-33(LC 10) Max Grav 1=157(LC 1), 3=165(LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. January 22,2019 04/08/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 14294 Truss V3 Truss Type Valley Qty 1 Ply 1 14294_CARDENAS_LOT_90 Job Reference (optional) I35906434 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jan 22 06:08:09 2019 Page 1 84 Components, Franklin, IN - 46131, ID:Ggt5P8Bb_A99dAuuwMdJk4zwiJU-R_NeMwp1_kleXJFlN4Upl0EQ_frhkW62cidGZHzsuLK Scale = 1:14.7 1 2 3 2x4 2x4 2x4 3-6-11 3-6-11 0-0-42-4-78.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.13 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-6-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=117/3-6-5, 3=117/3-6-5 Max Horz 1=58(LC 7) Max Uplift 1=-4(LC 10), 3=-24(LC 10) Max Grav 1=117(LC 1), 3=123(LC 17) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. January 22,2019 04/08/19 Mike Sheeks PRODUCT CODE APPROVALS LATERAL BRACING LOCATION Indicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the platewidth measured perpendicularto slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside" 16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS.W4 - 6 W3-6W3 -7 W2-7W1-7C1-8 C5-6C6-7C7-8 C4-5 C3-4C2-3C1-2 TOP CHORD TOP CHORD 8 7 6 54321 BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates therequired direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1" 4/3PLATE LOCATION AND ORIENTATION Symbols Numbering System General Safety Notes* Plate location details available in MiTek 20/20 software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8 WEBS Trusses are designed for wind loads in the plane of thetruss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1section 6.3 These truss designs rely on lumber valuesestablished by others.dimensions shown in ft-in-sixteenths 04/08/19 Mike Sheeks