Loading...
HomeMy WebLinkAbout65050-W1 SEALED 1903267-12T (1)BBO1 BBO2 6-09-00 22-07-0029-04-0014-03-0829-04-0020-07-00 11-03-00 39-09-08 5-10-00 77-05-08 77-05-08 GE01T03GE02 GE03GE04GE05T07T07GE06P02P03P05T01(10) T02(5) T04(7) T05(7)T06(12) P01(13)P04(12)29-04-0014-09-00 14-07-0029-04-0024-06-00 5-10-00 30-04-00 30-04-00 2-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-05-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-10-002-00-002-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 1317 N. Owen Street Rensselaer, IN 47978 1-800-866-7658 Designer: Paul Olson JOBNAME: CUSTOMERNAME: OLD TOWN DESIGN LOT 98 SUNRISE CONTRACT LUMBER JOB#: 1903267-12T DATE: 1/24/2019 JOBNOTES: Hangers connections are as shown on this drawing. All truss to truss connections that are not shown are toe- nailed. Please see the notes on this drawing for more information. Beams are by others. Trusses are 24" on center except as shown on this drawing. General Notes: THIS IS A TRUSS PLACEMENT DIAGRAM ONLY. These trusses are designed as individual building components to be incorporated into the building design at the specification of the Building Designer whose responsibilities include; the design and bracing of the overall structure, any supporting structure including the walls, headers, beams and columns and the permanent bracing of the roof and floor system. The General Contractor and/or their agents are responsible for; the verification of all dimensions, assuring that any conventional framing shall uniformly transfer the loads to the trusses below, the temporary bracing of the truss system as well as the permanent web bracing shown on the individual truss drawing sheets for the truss designs identified on this placement plan. For general guidance regarding bracing, consult "Bracing of Wood Trusses" available from the Truss Plate Institute 583 D'Onofrio Drive, Madison, WI 53179. COMPANY, INC. STARK TRUSS Dansco Engineering, LLC P.O. Box 3400 Apollo Beach, FL 33572 This truss placement diagram (TPD) has been prepared by component manufacturer technician(s) and reviewed by DANSCO Engineering, LLC for the design criteria shown on this TPD. DE accepts responsibility for specifying truss-to-truss connections within the truss system only. DE is not responsible for the design of this structure, for specifying permanent truss bracing, for specifying the attachment of the trusses and bracing to the structure, nor for specifying the diaphragm or sheathing (including attachment to the trusses) - these items are the responsibility of the design professional of record (engineer or architect of record). Review and approval of the design criteria shown is the responsibility of the design professional of record. The contractor shall be responsible for field verification of all dimensions, for means and methods of construction, for temporary bracing of the trusses, and for coordination of the work of all trades. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering, LLC P.O. Box 3400 Apollo Beach, FL 33572 Date: 3/29/19 DE Job# 65050-W1 04/09/19 Mike Sheeks DE DANSCO ENGINEERING, LLC P.O. Box 3400 Apollo Beach, FL 33572 Telephone (813) 645-0166 Facsimile (813) 645-9698 The truss drawing(s) attached have been prepared by Dansco Engineering, LLC under my direct supervision and control based on the parameters provided by Stark Truss Inc. Job: 1903267-12T 18 truss design(s) 65050-W1 3/29/19 Samuel A. Greenberg, P.E. Indiana Reg. #19700485 Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length is the distance from the top chord to bottom chord. The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI 1-2007 Chapter 2. Warning !—Verify design parameters and read notes before use. These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate Institute, 583 D’Onofrio Drive, Madison, WI 53719 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 4x4 3x4 3x8 3x8 4x6 4x6 171 31 30 29 28 2726 25 24 23 22 21 20 19 18 2 16 3 154 14 5 13 126 117 32 33 8 10 9 W1T 2T 1 T 2 T 1 W1B1 B2 ST6ST5ST4ST3ST2ST1ST5ST4ST3ST2ST10-10-8 -0-10-8 0-10-8 23-5-8 11-3-8 22-7-0 11-3-8 11-3-8 22-7-010-6-4 0-9-810-2-6 Scale = 1:64.4 Plate Offsets (X, Y): [4:0-2-12,0-2-4], [14:0-2-12,0-2-4], [18:0-1-13,0-0-4] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.17 Vert(LL)n/a -n/a 999 MT20 185/148 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.10 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.14 Horiz(TL)0.01 18 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-R BCDL 10.0 Weight: 129 lbFT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud *Except* ST6,ST5:2x4 HF/SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 9-24, 8-25, 10-23 REACTIONS All bearings 22-7-0. (lb) -Max Horiz31=298(LC 15) Max UpliftAll uplift 100 (lb) or less at joint(s) 18, 20, 23, 25, 29 except 19=-191(LC 17), 21=-105(LC 17), 22=-109(LC 17), 26=-108(LC 16), 28=-106(LC 16), 30=-209(LC 16), 31=-164(LC 12) Max GravAll reactions 250 (lb) or less at joint(s) 18, 19, 20, 21, 22, 23, 25, 26, 28, 29, 30, 31 except 24=290(LC 17) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-272/227, 8-9=-258/295, 9-10=-258/295 WEBS 9-24=-301/204 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Corner(3) -0-10-8 to 2-1-8, Exterior(2) 2-1-8 to 11-3-8, Corner(3) 11-3-8 to 14-3-8 zone; cantileverleft and right exposed ;end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal tothe face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)All plates are 1.5x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 10)Gable studs spaced at 2-0-0 oc. 11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 25,29, 23, 20 except (jt=lb) 31=164, 26=108, 28=106, 30=208, 22=109, 21=105, 19=191. 13)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T GE01 Common Supported Gable 1 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:12 Page: 1 ID:fIBWZIJU7vxgdc0TovAEdMzvPN8-qhNunaqN2rkmlltr2qqBXHtGMtoRmOcqyBeVI3zsVQb 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 3x4 6x6 6x6 3x4 3x6 3x4 3x8 3x4 3x5 3x8 3x5 3x4 3x5 3x8 3x10 3x8 3x6 3x8 3x8 3x4 3x4 3x4 141 21 20 19 18 17 16 15 132 27 5849 5750 26 25 4 24 115 51 1052 23 6 22 9 7 5354 5556 8 T2 T1 T3 T 4 T 5 B1 B2W9W11W9W14W15W5W7W2W1W13W12 W10 W 8 W 6 W4 W3 H W1HW1ST7ST6ST5ST4ST2ST3 ST10-10-8 30-2-8 0-10-8 -0-10-8 0-9-9 17-9-13 2-4-0 12-3-12 4-8-8 17-0-4 4-11-14 9-11-12 4-11-14 4-11-14 5-2-9 23-0-6 6-3-10 29-4-0 1-2-0 6-1-14 2-2-4 12-2-0 3-9-14 9-11-12 5-0-0 17-2-0 4-11-14 4-11-14 5-10-6 23-0-6 6-3-10 29-4-011-4-7 0-9-811-0-10 Scale = 1:68.8 Plate Offsets (X, Y): [7:0-4-4,0-2-0], [8:0-4-4,0-2-0], [13:0-4-15,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.44 Vert(LL)0.0515-47 >999 360 MT20 185/148 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.33 Vert(TL)-0.0815-16 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.43 Horiz(TL)0.03 13 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-MSH BCDL 10.0 Weight: 215 lbFT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 WEBS 2x4 SPF Stud *Except* W9,W11,W14,W5,W7:2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud SLIDER Left 2x4 SPF Stud --1-6-0, Right 2x4 SPF Stud --1-6-0 BRACING TOP CHORD Structural wood sheathing directly applied or 4-11-10 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 7-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 18-23, 11-16 JOINTS 1 Brace at Jt(s): 23, 24, 25, 26, 27REACTIONS (lb/size)2=432/0-3-8, (min. 0-1-8), 13=759/0-3-8, (min. 0-1-9), 19=1022/0-3-8, (min. 0-2-8) Max Horiz2=299(LC 15) Max Uplift2=-100(LC 17), 13=-200(LC 17), 19=-192(LC 16) Max Grav2=493(LC 54), 13=952(LC 39), 19=1504(LC 39) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 3-49=-456/144, 49-50=-400/147, 4-50=-363/163, 6-52=-100/285, 6-7=-320/246, 8-9=-478/264, 9-10=-543/278, 10-11=-698/248, 11-57=-993/239, 57-58=-1020/218, 12-58=-1095/212, 12-13=-340/0 BOT CHORD 2-21=-257/430, 20-21=-183/430, 19-20=-206/565, 17-18=-27/411, 16-17=-27/411, 15-16=-52/763, 13-15=-52/763 WEBS 18-23=-371/37, 8-23=-330/33, 16-22=-122/481, 8-22=-119/458, 11-16=-527/270, 19-26=-982/82, 6-26=-974/81, 6-25=-14/473, 18-25=-14/472, 4-27=-539/268, 19-27=-537/267, 9-22=-313/175, 22-23=-352/180, 23-24=-306/169, 24-25=-302/164, 25-26=-296/162, 26-27=-283/158, 20-27=-263/151 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 12-3-12, Exterior(2) 12-3-12 to 21-3-2, Interior(1) 21-3-2 to 30-2-8 zone;cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal tothe face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1, Lu=50-0-0 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Provide adequate drainage to prevent water ponding. 8)All plates are 1.5x4 MT20 unless otherwise indicated. 9)Gable studs spaced at 2-0-0 oc. 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 11)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint 2, 200 lb uplift at joint 13 and 192 lb uplift at joint 19. 12)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 13)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T GE02 Piggyback Base Structural Gable 1 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:13 Page: 1 ID:PlZrznbsFTNARORxHJ5ABizvPO4-JuxG?wr?p8sdNuS1cYLQ3VPNwH40VmN_BrO2qVzsVQa 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 4.5 3x5 1.5x43x4 1.5x4 1.5x4 1 4 2 10 11 12 3 T1 W1B1 ST10-10-8 -0-10-8 6-9-4 6-9-4 6-9-43-2-20-4-0 2-10-7 Scale = 1:36.7 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.59 Vert(LL)0.11 4-9 >692 360 MT20 185/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.46 Vert(TL)-0.28 4-9 >285 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.00 2 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-MP BCDL 10.0 Weight: 22 lb FT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2=282/0-3-8, (min. 0-1-8), 3=232/Mechanical Max Horiz2=124(LC 15) Max Uplift2=-99(LC 12), 3=-83(LC 16) Max Grav2=321(LC 2), 3=262(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 6-7-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for membersand forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal tothe face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Gable studs spaced at 2-0-0 oc. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 8)Refer to girder(s) for truss to truss connections. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 83 lb uplift at joint 3 and 99 lbuplift at joint 2. 10)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 11)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T GE03 Monopitch 1 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:14 Page: 1 ID:2WEWLGK3RjcIo0lj?hi?I3zvPOQ-n4VfCGsdaS_U?21EAFsfciyVMhOFEJM7QV7bMxzsVQZ 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 3x4 3x4 3x4 3x4 4x4 3x8 3x8 1 20 2 34 33 32 31 30 29 28 27 26 25 24 23 22 21 19 3 18 4 17 5 16 6 15 7 36 14 8 13 9 35 1210 11 T 2T1 T3 T 2 T 1 B1 B2 HW1 HW1ST8ST7ST6ST5ST4ST3ST2ST1ST9ST10ST11ST12ST13 0-10-8 30-2-8 0-10-8 -0-10-8 3-5-5 16-4-10 12-11-6 12-11-6 12-11-6 29-4-0 29-4-011-10-12 0-7-711-4-14 Scale = 1:69.6 Plate Offsets (X, Y): [2:0-3-8,Edge], [10:0-2-0,0-1-13], [12:0-2-0,0-1-13], [19:0-3-8,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.12 Vert(LL)n/a -n/a 999 MT20 185/148 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.08 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.22 Horiz(TL)0.01 19 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-SH BCDL 10.0 Weight: 184 lbFT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 OTHERS 2x4 HF/SPF No.2 *Except* ST3,ST2,ST1,ST11,ST12,ST13:2x4 SPF Stud WEDGE Left: 2x4 SPF Stud Right: 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 10-12. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 12-26, 11-27, 9-29, 8-30, 13-25 REACTIONS All bearings 29-4-0. (lb) -Max Horiz2=-314(LC 14) Max UpliftAll uplift 100 (lb) or less at joint(s) 19, 22, 27, 29, 33 except 2=-113(LC 12), 21=-176(LC 17), 23=-107(LC 17), 24=-107(LC 17), 25=-104(LC 17), 30=-125(LC 16), 31=-101(LC 16), 32=-106(LC 16), 34=-161(LC 16) Max GravAll reactions 250 (lb) or less at joint(s) 2, 19, 22, 23, 24, 25, 26, 27, 29, 30, 31, 32, 33, 34 except 21=266(LC 31) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-350/270, 8-9=-241/275, 10-11=-210/250, 12-35=-228/287, 13-35=-252/280, 18-19=-261/189 BOT CHORD 2-34=-171/258, 33-34=-171/258, 32-33=-171/258, 31-32=-171/258, 30-31=-171/258, 29-30=-171/258, 28-29=-171/258, 27-28=-171/258, 26-27=-171/258, 25-26=-171/258, 24-25=-171/258, 23-24=-171/258, 22-23=-171/258, 21-22=-171/258, 19-21=-171/258 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Corner(3) -0-10-8 to 2-4-10, Exterior(2) 2-4-10 to 12-11-6, Corner(3) 12-11-6 to 19-4-10, Exterior(2) 19-4-10 to 30-2-8 zone;cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal tothe face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1, Lu=50-0-0 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Provide adequate drainage to prevent water ponding. 8)All plates are 1.5x4 MT20 unless otherwise indicated. 9)Gable requires continuous bottom chord bearing. 10)Gable studs spaced at 2-0-0 oc. 11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 27,29, 33, 22 except (jt=lb) 2=113, 30=124, 31=101, 32=106, 34=160, 25=104, 24=106, 23=107, 21=175. 13)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 14)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T GE04 Piggyback Base Supported Gable 1 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:14 Page: 1 ID:iZRdIYGwcA_0hEslC86qb0zvPOV-n4VfCGsdaS_U?21EAFsfciydihU5EGw7QV7bMxzsVQZ 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 4x4 3x8 3x8 111 2 18 17 16 15 14 13 12 10 93 84 75 19 20 6 T 1T 1 B1 HW1 HW1ST4ST3 ST2 ST1ST3 ST2 ST10-10-8 -0-10-8 0-10-8 15-5-8 7-3-8 14-7-0 7-3-8 7-3-8 14-7-07-2-4 0-7-76-8-5 Scale = 1:51.8 Plate Offsets (X, Y): [2:0-3-8,Edge], [10:0-3-8,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.06 Vert(LL)n/a -n/a 999 MT20 185/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.04 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.11 Horiz(TL)0.00 10 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-SH BCDL 10.0 Weight: 69 lb FT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud WEDGE Left: 2x4 SPF Stud Right: 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS All bearings 14-7-0. (lb) -Max Horiz2=-185(LC 14) Max UpliftAll uplift 100 (lb) or less at joint(s) 2, 10 except 12=-110(LC 17), 13=-109(LC 17), 14=-105(LC 17), 16=-106(LC 16), 17=-109(LC 16), 18=-116(LC 16) Max GravAll reactions 250 (lb) or less at joint(s) 2, 10, 12, 13, 14, 15, 16, 17, 18 FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Corner(3) -0-10-8 to 2-1-8, Exterior(2) 2-1-8 to 7-3-8, Corner(3) 7-3-8 to 10-3-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal tothe face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)All plates are 1.5x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Gable studs spaced at 2-0-0 oc. 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 11)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10 except (jt=lb) 16=106, 17=108, 18=115, 14=104, 13=109, 12=109. 12)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T GE05 Common Supported Gable 1 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:14 Page: 1 ID:Icv34PT0IbSz3SxnVQO26uzvPMy-n4VfCGsdaS_U?21EAFsfciyeXhVsEIh7QV7bMxzsVQZ 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 3x4 6x6 3x8 3x4 3x5 3x4 6x6 3x8 3x5 3x8 3x6 2x4 2x4 3x8 3x8 1 11 22 21 20 19 18 17161514 13 12 2 10 24 23 45 54 5346 93 84 7 5247 5148 5049 65 T 2 T1 T3 T 2 T 1 B1 B2W1W2W3W4W3W2W1W7W6 W 5 HW1 HW1ST8 ST9 ST7 ST5 ST6 ST3 ST4 ST2 ST1 ST10 ST11 0-10-8 30-2-8 0-10-8 -0-10-8 1-0-2 22-9-15 3-5-5 16-4-10 5-5-2 21-9-13 6-6-1 29-4-0 6-6-1 6-6-1 6-5-5 12-11-6 0-6-7 14-10-12 1-6-12 14-4-5 1-7-10 16-6-6 6-3-9 12-9-10 6-3-9 22-9-15 6-6-1 29-4-0 6-6-1 6-6-111-10-12 0-7-711-4-14 Scale = 1:71.9 Plate Offsets (X, Y): [2:0-3-8,Edge], [5:0-4-0,0-1-12], [6:0-4-4,0-2-0], [10:0-3-8,Edge], [15:0-0-15,0-2-4] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.71 Vert(LL)0.0712-44 >999 360 MT20 185/148 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.36 Vert(TL)-0.1212-44 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.40 Horiz(TL)0.02 10 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-MSH BCDL 10.0 Weight: 220 lbFT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 WEBS 2x4 SPF Stud *Except* W2,W3,W4:2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud *Except* ST7:2x4 HF/SPF No.2 WEDGE Left: 2x4 SPF Stud Right: 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 5-5-12 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-17, 5-17, 6-13, 9-13 REACTIONS All bearings 15-0-8. except 10=0-3-8, 14=0-3-8 (lb) -Max Horiz2=-314(LC 14) Max UpliftAll uplift 100 (lb) or less at joint(s) 14, 15, 20, 21 except 17=-148(LC 16), 22=-123(LC 16), 2=-114(LC 17) Max GravAll reactions 250 (lb) or less at joint(s) 14, 15, 18, 19, 21, 22 except 17=847(LC 39),20=466(LC 39),2=323(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-45=-345/171, 45-46=-269/177, 3-4=-295/211, 4-47=-253/219, 5-6=-337/241, 6-50=-323/222, 50-51=-354/219, 51-52=-378/194, 7-52=-390/190, 7-8=-410/186, 8-9=-524/206, 9-53=-840/206, 53-54=-841/185, 10-54=-951/178 BOT CHORD 2-22=-223/276, 21-22=-153/276, 20-21=-153/276, 19-20=-153/276, 18-19=-153/276, 17-18=-153/276, 16-17=-121/254, 15-16=-121/254, 14-15=-32/325, 13-14=-32/325, 12-13=-9/646, 10-12=-9/646 WEBS 3-20=-419/106, 3-17=-256/257, 5-17=-671/17, 5-24=-35/378, 13-24=-34/371, 9-13=-375/182, 9-12=0/280, 8-23=-355/149, 23-24=-361/148, 15-24=-342/148 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 12-11-6, Exterior(2) 12-11-6 to 16-4-10, Interior(1) 20-7-9 to 30-2-8 zone; cantilever left and right exposed ; end verticalleft and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal tothe face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1, Lu=50-0-0 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Provide adequate drainage to prevent water ponding. 8)All plates are 1.5x4 MT20 unless otherwise indicated. 9)Gable studs spaced at 2-0-0 oc. 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 11)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 15,21, 14 except (jt=lb) 2=113, 17=147, 10=187, 22=123, 2=113. 12)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 13)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T GE06 Piggyback Base Structural Gable 1 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:15 Page: 1 ID:SUl5aP7ylI8LQohhhOQonBzvPPz-FG31PctFLm6LdCbQkzNu8wVe64mzzgJHf9t9vOzsVQY 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 4x4 2x4 2x41.5x4 1 5 2 6 4 3 T 1T 1 B1ST1 2-3-15 4-7-14 2-3-15 2-3-15 1-11-80-4-13 0-1-10 0-1-10 -0-1-10 1-9-14 1-9-14 Scale = 1:24.9 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.04 Vert(LL)n/a -n/a 999 MT20 185/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.03 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.01 Horiz(TL)0.00 4 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-P BCDL 10.0 Weight: 12 lb FT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-8-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS All bearings 4-8-8. (lb) -Max Horiz1=-48(LC 12) Max UpliftAll uplift 100 (lb) or less at joint(s) 1, 4, 5 except 2=-102(LC 16) Max GravAll reactions 250 (lb) or less at joint(s) 1, 2, 4, 5, 6 FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal tothe face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1 5)Unbalanced snow loads have been considered for this design. 6)Gable requires continuous bottom chord bearing. 7)Gable studs spaced at 4-0-0 oc. 8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 4except (jt=lb) 2=101. 10)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 11)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T P01 Piggyback 13 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:15 Page: 1 ID:vJgLxh6GXUZGLuGYnlv5NUzvPRH-FG31PctFLm6LdCbQkzNu8wVpd4rFzmPHf9t9vOzsVQY 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 4x4 2x4 2x41.5x4 1 5 6 2 4 3 T 1T 1 B1ST1 2-3-15 4-7-14 2-3-15 2-3-15 1-11-80-4-13 0-1-10 0-1-10 -0-1-10 1-9-14 1-9-14 Scale = 1:24.9 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.04 Vert(LL)n/a -n/a 999 MT20 185/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.03 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.00 5 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-MP BCDL 10.0 Weight: 12 lb FT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-8-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS All bearings 4-8-8. (lb) -Max Horiz1=12(LC 16), 2=-45(LC 12) Max UpliftAll uplift 100 (lb) or less at joint(s) 1, 5, 6, 2, 4 Max GravAll reactions 250 (lb) or less at joint(s) 1, 5, 6, 2, 4 FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal tothe face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1 5)Unbalanced snow loads have been considered for this design. 6)Gable requires continuous bottom chord bearing. 7)Gable studs spaced at 2-0-0 oc. 8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 2, 4, 6, 2, 4. 10)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 11)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T P02 Piggyback 1 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:16 Page: 1 ID:oA1Z2J_Qacd2zymN_tCzIfzvPQ9-jTdPdxtt63FCEMAcHgv7h71_OUAPiDsQtpciRqzsVQX 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 3x4 2x4 2x4 1 5 2 4 3 T 1T 1 B1 1-8-5 3-4-11 1-8-5 1-8-5 1-5-30-4-13 0-1-10 0-1-10 -0-1-10 1-3-91-3-9Scale = 1:22.9 Plate Offsets (X, Y): [2:0-2-1,0-1-0], [3:0-2-0,Edge], [4:0-2-1,0-1-0] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.02 Vert(LL)n/a -n/a 999 MT20 185/148 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.05 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.00 4 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-P BCDL 10.0 Weight: 8 lb FT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-5-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2=97/2-1-14, (min. 0-1-8), 4=97/2-1-14, (min. 0-1-8) Max Horiz2=-33(LC 14) Max Uplift2=-27(LC 16), 4=-27(LC 17) Max Grav2=110(LC 2), 4=110(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal tothe face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Gable requires continuous bottom chord bearing. 8)Gable studs spaced at 2-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 2 and 27 lbuplift at joint 4. 11)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 12)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T P03 Piggyback 1 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:16 Page: 1 ID:wPn2DxxwWN7cVLScl1818pzvPQD-jTdPdxtt63FCEMAcHgv7h71_lUAAiDsQtpciRqzsVQX 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 3x4 2x4 2x4 1 5 2 4 3 T 1T 1 B1 1-8-5 3-4-11 1-8-5 1-8-5 1-5-30-4-13 0-1-10 0-1-10 -0-1-10 1-3-91-3-9Scale = 1:22.9 Plate Offsets (X, Y): [2:0-2-1,0-1-0], [3:0-2-0,Edge], [4:0-2-1,0-1-0] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.02 Vert(LL)n/a -n/a 999 MT20 185/148 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.05 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.00 4 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-P BCDL 10.0 Weight: 8 lb FT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-5-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2=97/2-1-14, (min. 0-1-8), 4=97/2-1-14, (min. 0-1-8) Max Horiz2=-33(LC 14) Max Uplift2=-27(LC 16), 4=-27(LC 17) Max Grav2=110(LC 2), 4=110(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal tothe face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Gable requires continuous bottom chord bearing. 8)Gable studs spaced at 4-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 2 and 27 lbuplift at joint 4. 11)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 12)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T P04 Piggyback 12 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:16 Page: 1 ID:opOQDEy6bVw6Hum2WWB2MkzvPRU-jTdPdxtt63FCEMAcHgv7h71_lUAAiDsQtpciRqzsVQX 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 3x4 2x4 2x4 1 5 2 4 3 T 1T 1 B1 1-8-5 3-4-11 1-8-5 1-8-5 1-5-30-4-13 0-1-10 0-1-10 -0-1-10 1-3-91-3-9Scale = 1:22.9 Plate Offsets (X, Y): [2:0-2-1,0-1-0], [3:0-2-0,Edge], [4:0-2-1,0-1-0] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.02 Vert(LL)n/a -n/a 999 MT20 185/148 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.05 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.00 4 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-P BCDL 10.0 Weight: 8 lb FT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-5-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2=97/2-1-14, (min. 0-1-8), 4=97/2-1-14, (min. 0-1-8) Max Horiz2=-33(LC 14) Max Uplift2=-27(LC 16), 4=-27(LC 17) Max Grav2=110(LC 2), 4=110(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal tothe face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Gable requires continuous bottom chord bearing. 8)Gable studs spaced at 2-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 2 and 27 lbuplift at joint 4. 11)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 12)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T P05 Piggyback 1 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:17 Page: 1 ID:ZR_9AEtnhrUKOZafzUYsRmzvPQI-BfBnqHuWtNN3sWlprOQMELa9VuWPRg6Z6TMFzGzsVQW 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 3x4 4x6 3x4 3x8 3x4 3x4 1.5x4 3x4 1.5x4 3x8 3x4 3x4 111 14 13 12 102 2823 4 8 75 2724 2625 6 T2 T 1 T 2 T 1 B1 B2 W2W1W2W1H W1 HW 1 0-10-8 -0-10-8 0-10-8 23-5-8 5-6-0 16-9-8 5-6-0 11-3-8 5-9-8 5-9-8 5-9-8 22-7-0 7-4-0 14-11-8 7-7-8 7-7-8 7-7-8 22-7-010-6-4 0-9-810-2-6 Scale = 1:65.6 Plate Offsets (X, Y): [2:0-4-15,Edge], [10:0-4-15,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.33 Vert(LL)-0.0612-21 >999 360 MT20 185/148 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.43 Vert(TL)-0.1512-14 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.53 Horiz(TL)0.03 10 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-MSH BCDL 10.0 Weight: 103 lbFT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 *Except* W1:2x4 SPF Stud SLIDER Left 2x4 SPF Stud --1-6-0, Right 2x4 SPF Stud --1-6-0 BRACING TOP CHORD Structural wood sheathing directly applied or 5-1-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2=844/0-3-8, (min. 0-1-9), 10=844/0-3-8, (min. 0-1-9) Max Horiz2=-275(LC 14) Max Uplift2=-185(LC 16), 10=-185(LC 17) Max Grav2=956(LC 2), 10=956(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-553/0, 3-23=-1075/220, 4-23=-909/243, 4-5=-1026/325, 5-24=-994/337, 24-25=-987/340, 6-25=-986/357, 6-26=-986/357, 26-27=-987/340, 7-27=-994/337, 7-8=-1026/325, 8-28=-909/243, 9-28=-1075/220, 9-10=-495/0 BOT CHORD 2-14=-276/848, 13-14=-18/561, 12-13=-18/561, 10-12=-87/759 WEBS 6-12=-247/532, 8-12=-368/313, 6-14=-247/532, 4-14=-368/313 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 11-3-8, Exterior(2) 11-3-8 to 14-3-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 185 lb uplift at joint 2 and 185 lb uplift at joint 10. 8)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T T01 Common 10 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:17 Page: 1 ID:CTBG6WpetJs1IohhAxyhkizvPQN-BfBnqHuWtNN3sWlprOQMELa4euQORYvZ6TMFzGzsVQW 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 3x5 6x6 6x6 3x4 3x6 3x4 3x8 3x4 3x5 1.5x4 3x6 3x6 3x4 3x5 1.5x4 3x4 3x4 131 19 18 17 16 15 14 2 12 3528 3429 4 10 5 9 6 7 3031 3233 8 T 2T 1 T3 T 2 T 1 B1 B2 W5W6W5W7 W8W3W4W2W1 H W1HW1 0-10-8 -0-10-8 0-10-8 30-2-8 2-4-0 12-3-12 4-8-8 17-0-4 4-11-14 9-11-12 4-11-14 4-11-14 6-0-2 23-0-6 6-3-10 29-4-0 2-2-4 12-2-0 5-0-0 17-2-0 4-11-14 4-11-14 4-11-14 9-11-12 5-10-6 23-0-6 6-3-10 29-4-011-4-7 0-9-811-0-10 Scale = 1:68.8 Plate Offsets (X, Y): [7:0-4-4,0-2-0], [8:0-4-4,0-2-0] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.62 Vert(LL)0.0514-26 >999 360 MT20 185/148 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.35 Vert(TL)-0.1014-15 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.43 Horiz(TL)0.03 12 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-MSH BCDL 10.0 Weight: 169 lbFT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 *Except* W8,W2,W1:2x4 SPF Stud SLIDER Left 2x4 SPF Stud --1-6-0, Right 2x4 SPF Stud --1-6-0 BRACING TOP CHORD Structural wood sheathing directly applied or 4-11-7 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 7-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-17, 8-17, 10-15, 6-18REACTIONS (lb/size)2=441/0-3-8, (min. 0-1-8), 12=763/0-3-8, (min. 0-1-9), 18=1008/0-3-8, (min. 0-2-7) Max Horiz2=-299(LC 14) Max Uplift2=-113(LC 17), 12=-206(LC 17), 18=-183(LC 16) Max Grav2=497(LC 2), 12=963(LC 39), 18=1472(LC 39) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 3-28=-441/153, 28-29=-416/155, 4-29=-375/171, 6-7=-448/312, 7-30=-339/258, 30-31=-339/258, 31-32=-339/258, 32-33=-339/258, 8-33=-339/258, 8-9=-553/292, 9-10=-718/257, 10-34=-883/247, 34-35=-1041/226, 11-35=-1116/220, 11-12=-352/0 BOT CHORD 2-19=-259/439, 18-19=-180/439, 16-17=-30/401, 15-16=-30/401, 14-15=-64/786, 12-14=-64/786 WEBS 8-17=-587/120, 8-15=-143/518, 10-15=-579/300, 6-18=-1082/123, 6-17=-34/557, 4-18=-453/236 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 12-3-12, Exterior(2) 12-3-12 to 21-3-2, Interior(1) 21-3-2 to 30-2-8 zone;cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1, Lu=50-0-0 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Provide adequate drainage to prevent water ponding. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 113 lb uplift at joint 2, 206 lb uplift at joint 12 and 183 lb uplift at joint 18. 9)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 10)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T T02 Piggyback Base 5 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:18 Page: 1 ID:V0WdtTH2EoJH01KEbhANyQzvPR3-BfBnqHuWtNN3sWlprOQMELa09uRfRaRZ6TMFzGzsVQW 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 3x4 6x6 3x4 3x6 3x4 3x5 1.5x4 3x4 6x6 3x8 3x5 1.5x4 3x8 3x4 3x4 121 18 17 16 15 14 13 2 11 3427 3328 4 9 5 8 6 2930 3132 7 T 2T 1 T3 T 2 T 1 B1 B2 W1W2 W3W4W3W2 W1HW1 H W1 0-10-8 -0-10-8 0-10-8 30-2-8 4-8-8 17-0-4 6-0-2 23-0-6 6-0-2 12-3-12 6-3-10 6-3-10 6-3-10 29-4-0 2-2-4 12-2-0 3-8-2 9-11-12 5-0-0 17-2-0 5-10-6 23-0-6 6-3-10 6-3-10 6-3-10 29-4-011-4-7 0-9-811-0-10 Scale = 1:68.8 Plate Offsets (X, Y): [6:0-4-4,0-2-0], [7:0-4-4,0-2-0], [11:0-4-15,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.67 Vert(LL)0.0518-21 >999 360 MT20 185/148 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.50 Vert(TL)-0.1018-21 >786 240 TCDL 10.0 Rep Stress Incr YES WB 0.75 Horiz(TL)0.05 11 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-MSH BCDL 10.0 Weight: 152 lbFT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 *Except* W1:2x4 SPF Stud SLIDER Left 2x4 SPF Stud --1-6-0, Right 2x4 SPF Stud --1-6-0 BRACING TOP CHORD Structural wood sheathing directly applied or 4-2-1 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-16, 9-14REACTIONS All bearings 10-1-8. except 11=0-3-8, 17=0-3-8 (lb) -Max Horiz2=-299(LC 14) Max UpliftAll uplift 100 (lb) or less at joint(s) 18 except 2=-187(LC 16) Max GravAll reactions 250 (lb) or less at joint(s) 17 except 18=1230(LC 39),2=486(LC 54) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-251/44, 3-27=-459/221, 27-28=-433/226, 4-28=-397/248, 4-5=-857/326, 5-6=-684/361, 6-29=-669/350, 29-30=-669/350, 30-31=-669/350, 31-32=-669/350, 7-32=-669/350, 7-8=-829/362, 8-9=-1037/327, 9-33=-1188/314, 33-34=-1346/293, 10-34=-1421/287, 10-11=-407/0 BOT CHORD 2-18=-220/399, 17-18=-220/399, 16-17=-220/399, 15-16=-119/513, 14-15=-119/513, 13-14=-119/1016, 11-13=-119/1016 WEBS 4-18=-1107/160, 4-16=-82/415, 6-14=-116/371, 7-14=-110/286, 9-14=-564/298 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 12-3-12, Exterior(2) 12-3-12 to 21-3-2, Interior(1) 21-3-2 to 30-2-8 zone;cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1, Lu=50-0-0 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Provide adequate drainage to prevent water ponding. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18 except (jt=lb) 2=187, 11=229,2=187. 9)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 10)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T T03 Piggyback Base 1 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:18 Page: 1 ID:gs9MdQCHeyZ7I6t4FR3zi9zvPR9-frk92dv8ehVwUgK?P5xbmY7A2IlWAyajL75pVjzsVQV 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 3x5 6x6 3x5 4x8 3x4 3x5 1.5x4 3x4 6x6 3x8 3x5 1.5x4 4x8 3x4 3x4 121 17 16 15 14 13 2 11 3326 3227 4 9 5 8 6 2829 3031 7 T 2T 1 T3 T 2 T 1 B1 B2 W1W2 W3W4W3W2 W1HW1 H W1 0-10-8 -0-10-8 0-10-8 30-2-8 4-8-8 17-0-4 6-0-2 23-0-6 6-0-2 12-3-12 6-3-10 6-3-10 6-3-10 29-4-0 5-0-0 17-2-0 5-10-6 23-0-6 5-10-6 12-2-0 6-3-10 6-3-10 6-3-10 29-4-011-4-7 0-9-811-0-10 Scale = 1:68.8 Plate Offsets (X, Y): [6:0-4-4,0-2-0], [7:0-4-4,0-2-0] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.83 Vert(LL)-0.1016-17 >999 360 MT20 185/148 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.70 Vert(TL)-0.2216-17 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.32 Horiz(TL)0.10 11 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-MSH BCDL 10.0 Weight: 152 lbFT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 *Except* W1:2x4 SPF Stud SLIDER Left 2x4 SPF Stud --1-6-0, Right 2x4 SPF Stud --1-6-0 BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except 2-0-0 oc purlins (5-6-0 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-16, 6-14, 9-14REACTIONS (lb/size)2=1106/0-3-8, (min. 0-2-7), 11=1106/0-3-8, (min. 0-2-7) Max Horiz2=-299(LC 14) Max Uplift2=-225(LC 16), 11=-225(LC 17) Max Grav2=1464(LC 39), 11=1464(LC 39) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-638/0, 3-26=-1834/314, 26-27=-1794/320, 4-27=-1602/341, 4-5=-1463/356, 5-6=-1258/391, 6-28=-956/367, 28-29=-956/367, 29-30=-956/367, 30-31=-956/367, 7-31=-956/367, 7-8=-1259/391, 8-9=-1464/356, 9-32=-1601/341, 32-33=-1794/320, 10-33=-1834/314, 10-11=-504/0 BOT CHORD 2-17=-321/1326, 16-17=-258/1326, 15-16=-102/956, 14-15=-102/956, 13-14=-135/1326, 11-13=-135/1326 WEBS 4-16=-545/297, 6-16=-147/489, 7-14=-117/472, 9-14=-544/297 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 12-3-12, Exterior(2) 12-3-12 to 21-3-2, Interior(1) 21-3-2 to 30-2-8 zone;cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1, Lu=50-0-0 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Provide adequate drainage to prevent water ponding. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 225 lb uplift at joint 2 and 225 lb uplift at joint 11. 9)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 10)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T T04 Piggyback Base 7 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:18 Page: 1 ID:rio5MN8W36p_aBPwuAyZSvzvPRF-frk92dv8ehVwUgK?P5xbmY78bIiNA3QjL75pVjzsVQV 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 4.5 3x5 1.5x43x4 1 4 2 8 9 10 3 T1 W1B1 0-10-8 -0-10-8 6-9-4 6-9-4 6-9-43-2-20-4-0 2-10-7 Scale = 1:36.7 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.59 Vert(LL)0.11 4-7 >692 360 MT20 185/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.46 Vert(TL)-0.28 4-7 >285 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.00 2 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-MP BCDL 10.0 Weight: 20 lb FT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2=282/0-3-8, (min. 0-1-8), 3=232/Mechanical Max Horiz2=124(LC 15) Max Uplift2=-99(LC 12), 3=-83(LC 16) Max Grav2=321(LC 2), 3=262(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 6-7-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for membersand forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 6)Refer to girder(s) for truss to truss connections. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 83 lb uplift at joint 3 and 99 lbuplift at joint 2. 8)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 9)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T T05 Monopitch 7 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:19 Page: 1 ID:Vk?CJf4OEZAhUQXz5dMOlrzvPRK-71IYFzwmP_dm5pvBzoSqJmfM5i5QvabsanrM29zsVQU 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 3x4 6x6 3x4 3x4 3x5 1.5x4 3x4 6x6 3x8 3x5 1.5x4 4x8 4x8 1 10 15 1413 12 11 92 22 31 23 30 3 8 74 24 2925 28 2726 65 T 2T1 T3 T 2 T 1 B1 B2 W1W2 W3W4W3W2 W1HW1 HW1 0-10-8 30-2-8 0-10-8 -0-10-8 3-5-5 16-4-10 6-6-1 29-4-0 6-6-1 6-6-1 6-5-5 12-11-6 6-5-5 22-9-15 3-8-13 16-6-6 6-3-9 12-9-10 6-3-9 22-9-15 6-6-1 29-4-0 6-6-1 6-6-1 11-10-12 0-7-711-4-14 Scale = 1:70.8 Plate Offsets (X, Y): [2:0-3-8,Edge], [5:0-4-4,0-2-0], [6:0-4-4,0-2-0], [9:0-3-8,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.90 Vert(LL)-0.0914-15 >999 360 MT20 185/148 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.58 Vert(TL)-0.2214-15 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.35 Horiz(TL)0.08 9 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-MSH BCDL 10.0 Weight: 151 lbFT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 WEBS 2x4 HF/SPF No.2 *Except* W1:2x4 SPF Stud WEDGE Left: 2x4 SPF Stud Right: 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (5-3-1 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 5-12, 8-12 REACTIONS (lb/size)2=1100/0-3-8, (min. 0-2-7), 9=1100/0-3-8, (min. 0-2-7) Max Horiz2=-314(LC 14) Max Uplift2=-229(LC 16), 9=-229(LC 17) Max Grav2=1477(LC 39), 9=1477(LC 39) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-22=-1928/310, 22-23=-1828/316, 3-23=-1687/338, 3-4=-1501/345, 4-24=-1382/354, 24-25=-1363/356, 25-26=-1279/381, 5-26=-1095/383, 5-6=-973/364, 6-27=-1096/383, 27-28=-1281/381, 28-29=-1364/356, 7-29=-1383/354, 7-8=-1502/346, 8-30=-1686/338, 30-31=-1827/316, 9-31=-1927/310 BOT CHORD 2-15=-270/1404, 14-15=-270/1404, 13-14=-79/972, 12-13=-79/972, 11-12=-130/1404, 9-11=-130/1404 WEBS 3-15=0/259, 3-14=-604/313, 5-14=-154/498, 6-12=-137/487, 8-12=-602/313, 8-11=0/257 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 12-11-6, Exterior(2) 12-11-6 to 16-4-10, Interior(1) 20-7-9 to 30-2-8 zone; cantilever left and right exposed ; end verticalleft and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=20.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1, Lu=50-0-0 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Provide adequate drainage to prevent water ponding. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 229 lb uplift at joint 2 and 229 lb uplift at joint 9. 9)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 10)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T T06 Piggyback Base 12 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:19 Page: 1 ID:kCWBew_M76AqWCwQdxDWR9zvPRS-71IYFzwmP_dm5pvBzoSqJmfHDi3YvV4sanrM29zsVQU 04/09/19 Mike Sheeks DE Job # 65050-W1 Dansco Engineering, LLC Date: 3/29/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 1.5x4 4x6 4x6 4x6 51 6 2 4 13 18 1714 15 16 3 T 1T 1 B1 W1HW1 HW1 0-10-8 -0-10-8 0-10-8 15-5-8 7-3-8 14-7-0 7-3-8 7-3-8 7-3-8 14-7-0 7-3-8 7-3-87-2-40-7-76-8-5Scale = 1:53 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.61 Vert(LL)0.15 6-9 >999 360 MT20 185/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.47 Vert(TL)-0.21 6-9 >845 240 TCDL 10.0 Rep Stress Incr YES WB 0.13 Horiz(TL)0.03 2 n/a n/a BCLL 0.0 Code IBC2012/TPI2007 Matrix-MSH BCDL 10.0 Weight: 50 lb FT = 20% LUMBER TOP CHORD 2x4 HF/SPF No.2 BOT CHORD 2x4 HF/SPF No.2 WEBS 2x4 SPF Stud WEDGE Left: 2x4 SPF Stud Right: 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2=561/0-3-8, (min. 0-1-8), 4=561/0-3-8, (min. 0-1-8) Max Horiz2=-185(LC 14) Max Uplift2=-128(LC 16), 4=-128(LC 17) Max Grav2=636(LC 2), 4=636(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-13=-634/137, 13-14=-504/148, 14-15=-498/151, 3-15=-479/170, 3-16=-479/170, 16-17=-498/151, 17-18=-504/148, 4-18=-634/137 BOT CHORD 2-6=-173/414, 4-6=-25/414 WEBS 3-6=0/339 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 7-3-8, Exterior(2) 7-3-8 to 10-3-8 zone; cantilever left and right exposed; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pg=20.0 psf (ground snow); Pf=15.4 psf (flat roof snow: Lumber DOL=1.15Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.1 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other liveloads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 128 lb uplift at joint 2 and 128 lb uplift at joint 4. 8)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply OLD TOWN DESIGN GROUP 1903267-12T T07 Common 2 1 Job Reference (optional) Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.2 S 0 Apr 7 2018 Print: 8.200 S Apr 7 2018 MiTek Industries, Inc. Wed Jan 23 10:29:20 Page: 1 ID:RsbXAXuzmyHpA7u4jzbtfhzvPRZ-bEswTJxOAIldjzUNWWz3rzCXQ5RVe?l0oRawabzsVQT 04/09/19 Mike Sheeks