Loading...
HomeMy WebLinkAboutSunrise Spec -PRODUCTION (1)Layout Name 98 Sunrise on the Monon Description Spec 98 Sunrsise on the Monon COL-0119-4791 Created September 12, 2018 Revised January 14, 2019 Builder Sales Rep Designer Bill Delligatti Contract Lumber 200 Schofield Drive Columbus , OH 43213 614.751.1109 2ND I Joist (Flush) Label Description Width Depth Qty Plies Pcs Length J6 LPI 20Plus 2.5 14 7 15-0-0 J7 LPI 20Plus 2.5 14 2 15-0-0 J8 LPI 20Plus 2.5 14 7 30-0-0 J9 LPI 20Plus 2.5 14 5 5-0-0 J10 LPI 20Plus 2.5 14 4 30-0-0 J11 LPI 20Plus 2.5 14 4 15-0-0 LVL/LSL (Flush) Label Description Width Depth Qty Plies Pcs Length F2 LP-LVL 2900Fb-2.0E 1.75 14 2 8-0-0 F3 LP-LVL 2900Fb-2.0E 1.75 14 1 2 2 12-0-0 F4 LP-LVL 2900Fb-2.0E 1.75 16 1 2 2 20-0-0 LVL/LSL (Dropped) Label Description Width Depth Qty Plies Pcs Length DB1 LP-LVL 2900Fb-2.0E 1.75 11.875 1 2 2 23-0-0 Rim Board Label Description Width Depth Qty Plies Pcs Length A3/A7 LP APA Rated OSB 1.125 X 14 1.125 14 9 12 Lumber (Dropped) Label Description Width Depth Qty Plies Pcs Length D1 SP #2 1.5 7.25 1 2 2 8-0-0 DB3 SP #2 1.5 9.25 1 2 2 8-0-0 DB4 SP #2 1.5 9.25 1 2 2 12-0-0 DB2 SP #2 1.5 11.25 1 2 2 2-0-0 DB5 SP #2 1.5 11.25 1 2 2 16-0-0 DB6 SP #2 1.5 11.25 1 2 2 8-0-0 Hanger Beam/Girder Supported Member Label Pcs Description Skew Slope fasteners fasteners H1 2 IUS1.81/14 (Max) 14 10d 2 10dx1 1/2 H2 5 IUS2.56/14 (Max) 14 10dx1 1/2 2 10dx1 1/2 H3 7 Hanger By Others 2ND Design Method ASD Building CodeIBC/IRC 2015 Floor Loads Live 40 Dead 10 Deflection Joist LL Span L/ 480 TL Span L/ 240 LL Cant 2L/ 480 TL Cant 2L/ 240 Deflection Girder LL Span L/ 480 TL Span L/ 240 LL Cant 2L/ 480 TL Cant 2L/ 240 Decking Deck OSB 23/32 APA Rated Sturd- I-Floor Fastener Nailed & Glued(FLUSH BOTTOM)A3 A3 A3 A7 A7 8"16" 8" 10" HOLE CHASE 10" HOLE CHASE 10" HOLE CHASE 10" HOLE CHASE 10" HOLE CHASE 10" HOLE CHASE SE EMPIEZA AQUI START LAYOUT 16" O.C. B5-0 J6 @ 16" J1 @ 24"J62 X J7 J8 @ 16" J9 @ 16"J103 X J10 J11 @ 16"F2 ( 1 ply )F2 ( 1 ply )DB5 ( 2 ply )DB6 ( 2 ply ) DB2 ( 2 ply )DB1 ( 2 ply )DB4 ( 2 ply )DB3 ( 2 ply )F4 ( 2 ply ) F3 ( 2 ply )D1 ( 2 ply )H1H1H2 General Notes - It is the sole responsibility of the builder/installer to follow this layout exactly. Notify Contract Lumber of any discrepancies between this layout and field conditions. Contract Lumber is not liable for any field changes without prior approval. - Refer to details in the installation guide prior to construction ROOF LAYOUT J2 @ 24" Version 18.40.162 Powered by iStruct® This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them NEED FOOTINGS UNDER THESE WALLS 04/09/19 Mike Sheeks